A B C D
4 2 2 4
1.5
PORCH
W4 D3 W4 W4
D4
4 D2 4
D3
MASTER'S
COMFORT LAUNDRY BEDROOM COMFORT COMFORT
ROOM AREA ROOM ROOM
KITCHEN AREA
4
4
W1 W1
D3 D3
5.5
BEDROOM 1 BEDROOM 5
COMFORT COMFORT
ROOM ROOM
D2 D3 D2
3 D3 3
1.5
D2 D2
15
D2
12
4
DINING ROOM D3
4
D2
LIVING ROOM W2
W2 W2
A A A A
4
4
2 BEDROOM 2 2 BEDROOM 3
BEDROOM 4
W3 W3
W3
D2
8 9 10 11 12 13
8 9
4
D4
4
GARAGE
2.5
WATCHING AREA
2.5
7 6 5 4 3 2 1
D4
1
7 6 5 4 3 2 1
1 D1
12 PORCH
B
B
8
GROUND FLOOR PLAN
SCALED 1:100
SECOND FLOOR PLAN
SCALED 1:100
3.35
SECOND FLR FFL.
3.2
GROUND FLR FFL.
0.1
FRONT ELEVATION
SCALED 1:100
REAR ELEVATION
SCALED 1:100
3.35
SECOND FLR FFL.
3.2
GROUND FLR FFL.
LEGENDS: D4 W4
CONVENIENT OUTLET 4 S1 D2
4
W1
D3
COMFORT
PANEL BOARD BEDROOM 1
S3
ROOM
SERVICE ENTRANCE D2 S3
S3
3
S1 S3
D3
1.5
D2
S3
D2
12
DINING ROOM D3
4
LIVING ROOM
W2
BEDROOM 2
4
S3 S3 S2
2
W3
D4
4
GARAGE
2.5
S3S3
1
12
GROUND FLOOR
ELECTRICAL LAYOUT
SCALED 1:100
1.5
PORCH
D3 W4 W4
4 S3
D3
S1
COMFORT COMFORT
ROOM ROOM
4
W1
D3 COMFORT
MASTER'S ROOM
5.5
BEDROOM BEDROOM 5
S3
S1 D3 D2
3 S3
S3
S2S2
D2
15
4
D2
S2
W2
S2 W2
4
2 BEDROOM 3 S2
S2
BEDROOM 4
W3 W3
D2
S3
4
2.5
WATCHING AREA
D4
S2S2
1
PORCH
SHO
LEGENDS: WC LAUNDRY
KS
R RISE SHO
LAV
ADCB
WC WATER CLOSET
WM WASHING MACINE
W WATER METER DINING ROOM
CV CHECK VALVE
GV GATE VALVE LIVING ROOM
GARAGE
GROUND FLOOR
SANITARY & STORM DRAINAGE
SCALED 1:100
1.5
PORCH
4
SHO LAV
COMFORT
MASTER'S ROOM WC
BEDROOM WC
SHO
4
LAV
SHO
5.5
LAV
BEDROOM 5
COMFORT COMFORT
ROOM WC ROOM
3 4
2 BEDROOM 3
BEDROOM 4
4
2.5
WATCHING AREA
1
PORCH
SECOND FLOOR
SANITARY & STORM DRAINAGE
SCALED 1:100
TEE WYE
VENT STACK
DRY VENT 76 mm
BRANCH VENT
WC
TEE WYE
SOIL BRANCH
SHO TEE
ELBOW
TEE
BRANCH VENT
SOIL STACK
WET VENT - 76 mm LAV
ELBOW PTRAP
LAV
PTRAP
WC ELBOW
F.D.
C.O. TEE WYE
F.D.
90* LONG SWEEP ELBOW VENT THRU ROOF
SOIL BRANCH
WASTE PIPE
SHO WET VENT
SOIL BRANCH
WASTE PIPE
WET VENT
horizontal pipe - 102 mm
WC
SHO
LAV ELBOW
PTRAP
SOIL BRANCH
VENT STACK
DRY VENT 76 mm
LAV
TEE WYE
SOIL BRANCH
PTRAP
TEE WYE
F.D. F.D.
WASTE PIPE
CROSS TEE
TEE WYE WC
SOIL BRANCH
horizontal pipe - 102 mm
ELBOW
SOIL BRANCH
WC
TEE WYE
90* LONG SWEEP ELBOW
SHO
SOIL BRANCH
RISER
TEE WYE
SOIL STACK
WET VENT 76 mm
SE
CO
R ND
LOO F.D.
O ND F FL
SEC TEE WYE
O TO SEPTIC TANK
O
1/8 BEND
TEE WYE
R
1/8 BEND
TEE WYE
G
RO
KITCHEN SINK UN
D
FL
O
O
PTRAP
ELBOW HOUSE DRAIN
horizontal pipe - 102 mm
R
1/8 BEND
TEE WYE
ne
aterli
blic w
C.O. to pu
OOR
GRO
UND FL
90* LONG SWEEP ELBOW
WATER LINE,
SANITARY & STORM DRAINAGE
R CW
LEGENDS: 4
SHO
LAV LAVATORY KS
R RISE BEDROOM 1
WC
WM LAUNDRY
AREA
KITCHEN AREA
SHO SHOWER
4
LAV
SHO
KS KITCHEN SINK COMFORT COMFORT
LAV
ROOM
WC WATER CLOSET WC ROOM
WM WASHING MACINE 3
W WATER METER
1.5
CV CHECK VALVE
CW
GV GATE VALVE
4
DINING ROOM
4
BEDROOM 2
2
4
GARAGE
2.5
1
CV
W
GV
1.5
PORCH
4 R
SHO
LAV
COMFORT
MASTER'S ROOM WC
BEDROOM WC
SHO
4
LAV
SHO
5.5
LAV
BEDROOM 5
COMFORT COMFORT
ROOM WC ROOM
4
2 4
BEDROOM 3
BEDROOM 4
4
2.5
WATCHING AREA
1
PORCH
LAV
WC WM
LAV WC
LAV WC
KS LAV
CO CO
LA RO MF
AR UN OM OR LAV RO MFO
BE WC EA DR T OM R
D Y WC T
RO WC
OM BE CO
2 DR RO MF
KIT OO OMOR
CH M T
3
EN
LIV AR
IN EA
G BE
RO DR
OM OO
M
5
DIN
ING
RO
OM
BE
DR
OO
M
GA WA 4
RA TC
GE HI
PO NG
RC AR
H EA
CV
W
GV
TO MAIN WATER LINE
PIPE SIZES
vertical pipe 102 mm
horizontal pipe 102 mm
vent pipe 65 mm
100 mm THK SLAB w/ 12 mm diameter TEMP MAIN BAR
200 mm THK. SLAB ON FILL w/ 10 mm diameter TEMP. BARS 5 set water closet with fittings and accessories
PEA GRAVEL 5 set of lavatories with faucet, P-trap and accessories
SECTION 5 floor drain strainer
5 soap holder
1 kitchen sink
5 towel bar
5 shower faucet
DETAIL OF SEPTIC VAULT
DRAWN NOT TO SCALED
PLUMBING ESTIMATION
2.10
2.10
DOOR 1 DOOR 2 DOOR 3
1.00
1.50
1.50
1.50
0.50
WINDOW 1 WINDOW 2 WINDOW 3 WINDOW 4
0.20
0.40
0.30
1.20
6-16Ø CONT. BARS W/ 10mmØ
TIES SPACED 2@0.05, 3@0.15,
REST @ 0.20 M.O.C.
0.30
ELEVATION
DRAWN NOT TO SCALE
1.4 .8
10mmØ VERT. BARS @ EVERY
1.00m 400mm ON CENTER
0.30
10mm THK. COMPACTED
0.10m THICK GRAVEL BED GRAVEL BASE
0.20
8-16mmØ BASEBARS
EQUALLY
6-20mmØ CONT. BARS W/
1.20
1.50 0.30 10mmØ TIES SP. 2@0.05, 3@0.10
0.35 8-20mmØ CONT. BARS W/ 3@0.15, REST @ 0.20 M.O.C
10mmØ TIES SP. 2@0.50,
3@0.10, 3@0.15
REST @ 0.20 M.O.C.
WF2 TB
C2/F2
C2/F2
C2/F2
WF2 WF2
WF1
WF2 WF2
C2/F2
C1/F1
C1/F1
C1/F1
WF1 WF1 WF1 TB
C1/F1
TB
WF1
TB
WF1
WF2
C1/F1
C1/F1
C1/F1
C1/F1
TB TB WF1
WF2
WF2
C2/F2
WF1
TB
WF1
C1/F1
C1/F1
WF1 WF1 TB
C1/F1
C2/F2
FOUNDATION PLAN
SCALED 1:100
BEAM 2
BEAM 1
BEAM 1
BEAM 1
BEAM 2
BEAM 1
BEAM 2
BEAM 2
BEAM 1
BEAM 1
BEAM 1 BEAM 1 BEAM 1 BEAM 1 BEAM 1
BEAM 1
BEAM 1
BEAM 2
BEAM 1
BEAM 2
BEAM 2
BEAM 1
BEAM 2
BEAM 1
BEAM 1
BEAM 1 BEAM 1 BEAM 1 BEAM 1 BEAM 1
BEAM 1
BEAM 1
BEAM 2
BEAM 1
BEAM 2
BEAM 1
BEAM 1 BEAM 1 BEAM 1 BEAM 1 BEAM 1
RB1
RB1
BEAM 1
BEAM 1
RB2
RB2
RB2
RB1
RB1
BEAM 1 BEAM 1 BEAM 1 BEAM 1 BEAM 1
BEAM 1
RB2
RB1
RB2
RB2
RB1
BEAM 1
RB1
BEAM 1
RB2
RB2
RB2
BEAM 1 BEAM 1 BEAM 1 BEAM 1 BEAM 1
BEAM 1
RB1
RB1
BEAM 1
BEAM 1 BEAM 1 BEAM 1 BEAM 1
0.35 2-12mmØ 0.35 2-12mmØ 0.35 0.35 NOTE: PROVIDE LINTEL BEAM ON ALL DOOR AND
WINDOW HEADERS AROUND PERIMETER WALLS
BEAM 1 BEAM 2
DRAWN NOT TO SCALE DRAWN NOT TO SCALE
10mmØ C-TIES
0.35 0.35 0.30 0.30 0.15 SPACED @ EVERY
0.20m O.C.
3-16mmØ 5-16mmØ 2-16mmØ 4-16mmØ NOTE: PROVIDE LINTEL BEAM ON ALL DOOR AND
1-10mmØ WINDOW HEADERS AROUND PERIMETER WALLS
@SUPPORT @MIDSPAN @SUPPORT @MIDSPAN
SCHEDULE OF BEAMS
DRAWN NOT TO SCALE
0.125
10mmØ NOSING BAR 10mmØ CONT. BARS
SPACED @ 125mm O.C
0.1
10mmØ 50mm x 5mm thk
SPACED @
25
SAG RODS
800mm O.C.
G.I. LONG SPAN
10mmØ CONT. BARS PRE-PAINTED
SPACED @ 125mm O.C.
0.125
ROOFING
0.30
VARIES
0.20
10mmØ NOSING BAR
0.20
10mmØ CHAIR BAR 0.90 0.90 0.90 0.90 0.90 0.90 0.90
SCALED 1:100