Professional Documents
Culture Documents
Schenck S-Type Load Cell Catalogue
Schenck S-Type Load Cell Catalogue
Schenck S-Type Load Cell Catalogue
SPI 4135 e
Back to CONTENTS
Features
High Alloy Tool Steel Construction for resistance
against shock and overload
Complete environmental protection
Description
These strain gauge based load cells are used in tank and hopper weighing, scale conversions and in-line
force measurement applications.They are also applied to measure static and dynamic, tensile or compressive
loads in research. Versatile and compact unit works in tension and compression and is lightweight. It is
also rugged and scaled for use in washdown areas. Standardized output is available on request (3.0±0.25%).
Technical Data
Standard Capacities (Kgs) : 20Kg, 50Kg, 75Kg, 100Kg, 150Kg, 200Kg, 250Kg, 300Kg, 500Kg,
750Kg & 1000Kg
Excitation Voltage : 10VDC. Maximum 15VDC
Rated Output : 3.0mV/V (Nominal)
Non-Linearity : < ± 0.025% Full Scale Output (FSO)
Hysteresis : < ± 0.02% FSO
Non-Repeatibility : < ± 0.01% FSO
Creep (30min) : < ± 0.03% FSO
Zero Balance : ± 1.0% FSO
Bridge Resistance : 350Ω (Nominal)
Insulation Resistance : > 1000 Mega Ω at 50VDC
Safe Overload : 150% of Rated Capacity
Temperature
Compensated Range : 0 to 600C
Effect on Output : < 0.0015% FSO/0C
Effect on Zero : < 0.0025% FSO/0C
Deflection : < 0.5 mtrs / FSO
Construction : Electroless Nickel Plated Steel
Electrical Termination
Capacity in Kgs A B(Max) C T (Threads) Input Output Shield
Red (+) Green (+)
20 to 100 50 20 62 M-6 x 1.0 Black (-) White (-)
150 to 1000 50 28 62 M-12 x 1.25 Compression Positive
Page 2