VXD Series
RoHS
VX2
Approx. 7%Smaller
(VXD24)
∗
(7 mm) 20 %Lighter
(VXD23 Resin body)
∗
(90 g)
Class H/DIN terminal
Seal material: EPDM
VXB
VXE
∗ Comparison with SMC current model VXP
Power
Current
VXD consumption VXR
7
model (DC/N.C. valve) Air
− mm
4.5 W (VXD23 to 25) Body material VXH
7 W (VXD26, 27) Resin (VXD2 ) Aluminum (VXD2 )
3
A
3
A VXF
10.5 W (VXD28, 29)
VX3
VXA
103.5 mm (Current model)
Bracket standard
equipment
(New VXD)
Body material
C37, Stainless steel, CAC408
(VXD2A3 to 2D6 ) (VXD2E7 to 2G9 )
Class B Class H
∗
Enclosure IP65 CAC408 body
∗ Electrical entry flat terminal type terminal is IP40.
113
Pilot Operated 2 Port Solenoid Valve VXD Series
Clearance
Air Water Oil Heated water High temperature oil By providing a bumper and clearance, we
(99°C) (99°C)
reduced the collision sound of the core
Enclosure when ON (when the valve is open). Because
of the clearance, when using highly viscous
IP65
fluids such as oil, the armature does not get
stuck and the responsiveness when OFF
(when the valve is closed) is improved.
Port size
Orifice Body
Model Size Thread Flange One-touch fitting
diameter material
1/4 3/8 1/2 3/4 1 32A 40A 50A ø10 ø3/8" ø12
Aluminum — — — — — — — —
8A
3 Resin — — — — — — — —
VXD2A 10A 10 mmø
15A C37 — — — — — — — —
Stainless steel — — — — — — — —
4 10A C37 — — — — — — — — —
VXD2B 15 mmø
15A Stainless steel — — — — — — — — —
5 C37 — — — — — — — — — —
VXD2C 20A 20 mmø
Stainless steel — — — — — — — — — —
6 C37 — — — — — — — — — —
VXD2D 25A 25 mmø
Stainless steel — — — — — — — — — —
VXD2E7 32A 35 mmø — — — — — — — — — —
VXD2 F8 40A 40 mmø CAC408 — — — — — — — — — —
VXD2G9 50A 50 mmø — — — — — — — — — —
114
INDEX Pilot Operated 2 Port Solenoid Valve
VXD Series
115
VXD Series
Common Specifications
Standard Specifications
Class H Class H
Model Power consumption (W) Note 1) Temperature rise (°C) Note 2) Model Power consumption (W) Note 1) Temperature rise (°C) Note 2)
VXD23 to 25 9 100 VXD2A to 2C 9 100
VXD26, 27 12 100 VXD2D, 2E 12 100
VXD28, 29 15 100 VXD2F, 2G 15 100
Note 1) Power consumption: The value at ambient temperature of 20°C and when the rated voltage is applied. (Variation: ±10%)
Note 2) The value at ambient temperature of 20°C and when the rated voltage is applied. The value depends on the ambient environment.
This is for reference.
AC Specification (Built-in Full-wave Rectifier Type) AC Specification (Built-in Full-wave Rectifier Type)
Class B Class B
Model Apparent power (VA) Note 1) 2) Temperature rise (°C) Note 3) Model Apparent power (VA) Temperature rise (°C)
VXD23 to 25 7 60 VXD2A to 2C 9 60
VXD26, 27 9.5 70 VXD2D, 2E 10 70
VXD28, 29 12 70 VXD2F, 2G 14 70
Class H Class H
Model Apparent power (VA) Note 1) 2) Temperature rise (°C) Note 3) Model Apparent power (VA) Note 1) 2) Temperature rise (°C) Note 3)
VXD23 to 25 9 100 VXD2A to 2C 9 100
VXD26, 27 12 100 VXD2D, 2E 12 100
VXD28, 29 15 100 VXD2F, 2G 15 100
Note 1) Apparent power: The value at ambient temperature of 20°C and when the rated voltage is applied. (Variation: ±10%)
Note 2) There is no difference in the frequency and the inrush and energized apparent power, since a rectifying circuit is used in the AC.
Note 3) The value at ambient temperature of 20°C and when the rated voltage is applied. The value depends on the ambient environment.
This is for reference.
116
VXD Series
Selection Steps
Selection Steps
VX2
Step 1 Select the fluid.
Item Selection item Page Symbol
VXK
Air Page 118 0 VXD
Water Page 121 2 VXZ
Select the fluid. Oil Page 124 3 q VXD2 3 0 A A VXS
Heated Page 127 5 q
water
VXB
High Page 130 6
temperature oil
VXE
VXP
Step 2 Select “Body material”, “Port size” and “Orifice diameter” from “Flow rate — Pressure” of each fluid.
Item Selection item Symbol
VXR
Size 8A VXH
3 w
Select from “Flow
rate — Pressure.”
Valve type N.C. e VXF
Body material
Port size
Body material Aluminum VXD2 3 0 A A VX3
Orifice diameter Port size 1/4 A e w
VXA
Orifice diameter 10
Voltage 24 VDC
Select electrical
specification. Electrical entry Grommet
A r VXD2 3 0 A A
r
117
VXD Series
For Air
Model/Valve Specifications
N.C.
Symbol
2
External Leakage
Leakage rate (Air) Note 1)
Seal material VXD23 to 26 VXD27 to 29
(8A to 25A) (32A to 50A)
15 cm3/min or less (AIuminum body type)
NBR (FKM) Note 2) 15 cm3/min or less (Resin body type) 1 cm3/min or less
1 cm3/min or less (Metal body type)
Note 1) Leakage is the value at ambient temperature 20°C.
Note 2) For seal material/FKM, refer to “Other options” on page 133 for the
selection.
118
Pilot Operated 2 Port Solenoid Valve VXD Series
For Air
Symbol
VXD
2
VXZ
VXS
1
External Leakage
Leakage rate (Air) Note 1)
Seal material VXD2A to 2D VXD2E to 2G
(8A to 25A) (32A to 50A)
15 cm3/min or less (AIuminum body type)
NBR (FKM) Note 2) 15 cm3/min or less (Resin body type) 1 cm3/min or less
1 cm3/min or less (Metal body type)
Note 1) Leakage is the value at ambient temperature 20°C.
Note 2) For seal material/FKM, refer to “Other options” on page 133 for the
selection.
119
VXD Series
For Air
RoHS
How to Order
VXD2 3 0 A A
Common Specifications
Seal material NBR
Coil insulation type Class B
Thread type Rc∗
Fluid ∗ When the body is resin, one-touch fittings
0 For Air are supplied. For body size 32A or more,
the ports will be the flange type.
Voltage/Electrical entry
Size—Valve type Body material/Port size/Orifice diameter
Symbol Voltage Electrical entry
Valve Body Orifice
Symbol Size Symbol Port size
type material diameter Grommet
A 1/4
3 N.C. B Aluminum 3/8 A 24 VDC
8A
C 1/2
10A 10
D ø10 One-touch fitting
15A
A N.O. E Resin ø3/8" One-touch fitting B 100 VAC Grommet
F ø12 One-touch fitting With surge
C 110 VAC voltage
G 3/8 D 200 VAC suppressor
4 N.C. C37
10A H 1/2
15 E 230 VAC
15A J Stainless 3/8
B N.O. steel F 24 VDC
K 1/2
G 24 VDC DIN terminal
5 N.C. L C37 With surge
20A 3/4 20 H 100 VAC
C N.O. M Stainless steel voltage
J 110 VAC suppressor
6 N.C. N C37
25A 1 25 K 200 VAC
D N.O. P Stainless steel
L 230 VAC
7 N.C.
32A Q CAC408 32A Flange 35 M 24 VDC Conduit terminal
E N.O. With surge
N 100 VAC voltage
8 N.C.
40A R CAC408 40A Flange 40 P 110 VAC suppressor
F N.O.
Q 200 VAC
9 N.C.
50A S CAC408 50A Flange 50 R 230 VAC
G N.O.
S 24 VDC Conduit
With surge
T 100 VAC voltage
U 110 VAC suppressor
V 200 VAC
W 230 VAC
Flat terminal
Y 24 VDC
For Water
∗ Possible to use this for air.
Note that the maximum operating pressure
differential and flow rate characteristics
should be within the specifications for air.
Symbol VXD
2
VXZ
VXS
1
121
VXD Series
For Water
Model/Valve Specifications
N.O.
Symbol
2
122
Pilot Operated 2 Port Solenoid Valve VXD Series
For Water
RoHS
How to Order
7 N.C.
L 230 VAC VX3
32A Q CAC408 32A Flange 35 M 24 VDC Conduit terminal
E N.O.
N 100 VAC
With surge VXA
voltage
8 N.C.
40A R CAC408 40A Flange 40 P 110 VAC suppressor
F N.O.
Q 200 VAC
9 N.C.
50A S CAC408 50A Flange 50 R 230 VAC
G N.O.
S 24 VDC Conduit
With surge
T 100 VAC voltage
U 110 VAC suppressor
V 200 VAC
W 230 VAC
Flat terminal
Y 24 VDC
Model/Valve Specifications
N.C.
Symbol
2
124
Pilot Operated 2 Port Solenoid Valve VXD Series
For Oil
When the fluid is oil.
The kinematic viscosity must not exceed 50 mm2/s.
The special construction of the armature adopted in the
built-in full-wave rectifier type gives an improvement in
OFF response by providing clearance on the absorbed
surface when it is switched ON.
Symbol VXD
2
VXZ
VXS
1
125
VXD Series
For Oil
RoHS
How to Order
V 200 VAC
W 230 VAC
Flat terminal
Y 24 VDC
Symbol VXD
2
VXZ
VXS
1
127
VXD Series
For Heated water
Model/Valve Specifications
N.O.
Symbol
2
128
Pilot Operated 2 Port Solenoid Valve VXD Series
For Heated water
RoHS
How to Order
W 230 VAC
Z Other voltages
Note) For the class H type DIN terminal, use it in combination
with the connector provided.
129
VXD Series
When the fluid is oil.
For High temperature oil The kinematic viscosity must not exceed 50 mm2/s.
The special construction of the armature adopted in the
∗ Possible to use this for air (up to 99°C) and water. built-in full-wave rectifier type gives an improvement in
Note that the maximum operating pressure differential and OFF response by providing clearance on the absorbed
flow rate characteristics should be within the specifications of surface when it is switched ON.
the fluid used.
Model/Valve Specifications
N.C.
Symbol
2
130
Pilot Operated 2 Port Solenoid Valve VXD Series
For High temperature oil
When the fluid is oil.
The kinematic viscosity must not exceed 50 mm2/s.
The special construction of the armature adopted in the
built-in full-wave rectifier type gives an improvement in
OFF response by providing clearance on the absorbed
surface when it is switched ON.
Symbol VXD
2
VXZ
VXS
1
131
Series VXD
For High temperature oil
RoHS
How to Order
W 230 VAC
Z Other voltages
Note) For the class H type DIN terminal, use it in combination
with the connector provided.
132
VXD Series
Other Special Options
Electrical Options Other Options
(Low concentration ozone resistant and applicable
(Special voltage, With light, Without DIN connector) to deionized water, Oil-free, Port thread)
VX2
VXD2 3 0 A Z 1A VXD2 3 0 A A Z
VXK
Enter standard Enter standard
product number. VXD
product number.
Electrical option Other option (Low concentration ozone resistant and
Electrical specification/Voltage/Electrical entry applicable to deionized water/Oil-free/Port thread) VXZ
Specification Symbol Class H∗ Voltage Electrical entry Low concentration ozone resistant and applicable
1A 48 VAC Symbol
to deionized water ∗1, ∗4 (Seal material: FKM)
Oil-free Port thread∗3
VXS
1B 220 VAC Grommet Nil — — Rc, With One-touch fitting∗2
1C 240 VAC (With surge voltage suppressor)
1U
24 VAC
A
— —
G VXB
1D — 12 VDC Grommet B NPT
1E — 12 VDC
Grommet C — Rc, With One-touch fitting∗2 VXE
(With surge voltage suppressor) D G
—
1F E
1G
48 VAC
220 VAC
NPT
VXP
DIN terminal F G
Special voltage
1H 240 VAC —
G NPT
1V 24 VAC
(With surge voltage suppressor)
H Rc, With One-touch fitting∗2
VXR
1J — 12 VDC
K G
1K
1L
48 VAC
220 VAC L NPT VXH
Conduit terminal
1M 240 VAC Z — Rc, With One-touch fitting∗2
1W 24 VAC
(With surge voltage suppressor)
∗1 Applicable to air (VXD20) and water (VXD22). VXF
1N — 12 VDC ∗2 One-touch fittings are attached to the resin body type.
1P
1Q
48 VAC
220 VAC
∗3 Only flange type is available for 32A to 50A. VX3
Conduit Rc, G, and NPT cannot be selected.
1R 240 VAC ∗4 When using deionized water or any other fluid that may corrode C37
1Y 24 VAC
(With surge voltage suppressor)
(brass), select a stainless steel body. VXA
1S — 12 VDC
1T — 12 VDC Flat terminal
2A 24 VDC
2B 100 VAC Made to Order
2C 110 VAC
2D 200 VAC <Special lead wire length>
2E 230 VAC DIN terminal Produced upon receipt of order. Please contact SMC for lead times.
2F 48 VAC (With surge voltage suppressor)
2G
2H
220 VAC
240 VAC
VXD XL
2V 24 VAC
With light
3A
24 VDC —
Without DIN connector
3B
100 VAC—
3C
110 VAC—
3D
200 VAC—
3E
230 VAC— DIN terminal
3F —
48 VAC (With surge voltage suppressor)
3G
220 VAC—
3H
240 VAC—
3V
24 VAC— ∗ Enter symbols in the order below when ordering a combination of
3J
12 VDC — electrical option, other option, etc.
∗ Options marked with are available for Class “H” coil.
Applicable for all when the coil insulation class is Class “B”. Example) VXD2 3 2 A Z 1A Z
Electrical option
Other option
133 B
VXD Series
Installation Options
(Special Electrical Entry Direction/Mounting Option)
The following shows combinations that can be selected using installation options.
Combinations
Symbol Special electrical entry direction With bracket Seal material: EPDM
XC
XB
X332
VXD2 XC A VXD2 XB A
Enter standard product number. Enter standard product number.
A
IN OUT OUT IN Nil IN OUT B IN OUT
180° 180°
∗
180° 180° 90° 270° 270°
90°
B IN OUT
OUT IN
A IN OUT C IN OUT
270° 270° ∗
270°
270° 3 6
∗1 Available for the VXD2 A to 2 D. C
3
∗2 Bracket is attached as standard with the resin body type (VXD2 A 0 DE),
so it is no necessary to add XB to the part number.
IN OUT OUT IN
C ∗3 The bracket for aluminum, C37 and stainless steel body type of the
VXD23 is shipped together with the product, but not assembled. (Refer
to the figure below for mounting.)
Bracket
∗ Enter symbols in the order below when ordering a combination of
Tightening torque of
electrical option, other option, etc.
2 to 3 N·m
Example) VXD2 3 2 A Z 1A Z XB A Tightening torque of
2 to 3 N·m
Electrical option Special electrical
entry direction
Other option With bracket
134
Other Special Options VXD Series
Installation Options
(Special Electrical Entry Direction/Mounting Option)
Nil
Electrical entry direction
Standard
Bracket
Nil
Standard
A
90° VXE
· IN OUT · IN OUT
A 90° D E
B 180°
None VXP
C 270° 180° 270°
D Standard VXR
B IN OUT C IN OUT
E 90° · ·
With bracket∗1 F G VXH
F 180°
G 270°
3
∗1 Not available for the VXD2 A (resin body type) and VXF
7 9
the VXD2 E to VXD2 G.
∗2 “Other options” (refer to page 20), which can be
combined, are Nil, A, B, D, E, Z (Oil-free, G thread
VX3
specifications, NPT thread specifications).
∗3 Available for air and water. VXA
135
VXD Series
Construction
Normally Closed (N.C.)
i
i
!2
!2
!0
!0
t !1
!1
t o
o y
y IN(P1)
u
IN(P1) u r
r OUT(P2)
A
OUT(P2)
A B
B IN(P1)
e IN(P1) C
C
e
w q
VXD23 q VXD24
w
!2
i i !0
!2 A B
!0 !1
t !1 o
B o u
u w OUT
C IN(P1) (P2)
r A r
OUT(P2)
IN
e e (P1)
w C
IN(P1)
q q
VXD25, 26 VXD27, 28, 29
Component Parts
No. Description Model Material Operation
VXD23 C37, Stainless steel, Aluminum, Resin (PBT) <Valve open>
1 Body VXD24 to 26 C37, Stainless steel When coil !2 is energized, armature assembly !1 is attracted
VXD27 to 29 CAC408 by core i and pilot valve A is open.
VXD23, 24 Stainless steel When A is open, the pressure in pressure chamber B is
2 Bonnet VXD25, 26 C37, Stainless steel reduced and main valve C is open.
VXD27 to 29 CAC408 <Valve closed>
3 Diaphragm assembly VXD23 to 29 Stainless steel, NBR, FKM, EPDM When coil !2 is de-energized, pilot valve A is closed, pres-
4 Spring VXD23 to 29 Stainless steel sure in pressure chamber B increases, and main valve C
is closed.
5 O-ring VXD23 to 26 NBR, FKM, EPDM
6 Buffer VXD23, 24 PPS
7 Stopper NBR, FKM, EPDM
8 Core Fe
9 Tube Stainless steel
VXD23 to 29
10 Spring Stainless steel
11 Armature assembly Stainless steel, NBR, FKM, EPDM, Resin (PPS)
12 Solenoid coil Cu + Fe + Resin
136
Construction VXD Series
!4 u
!4 u
i
i VX2
!0
!2 !0 VXK
!2
!1 t !1 VXD
t
o y o VXZ
y IN(P1)
!3
IN(P1) !3 r VXS
r OUT(P2)
OUT(P2)
A B A VXB
B
e
IN(P1)
C e IN(P1)
C VXE
w q w q VXP
VXD2A VXD2B
VXR
!4 i
!4 u VXH
u !0
i !1 A B VXF
!2 !0 !2 VX3
t !1 o VXA
!3
o
OUT
IN(P1) w (P2)
B !3
OUT(P2) r
r A
IN
e (P1)
e IN(P1) C
C
w q
q
VXD2C, 2D VXD2E, 2F, 2G
Component Parts
No. Description Model Material Operation
VXD2A C37, Stainless steel, Aluminum, Resin (PBT) <Valve closed>
1 Body VXD2B to 2D C37, Stainless steel When coil !4 is energized, (already open) pilot valve A is
VXD2E to 2G CAC408 closed, pressure in pressure chamber B increases, and
VXD2A, 2B Stainless steel main valve C is closed.
2 Bonnet VXD2C, 2D C37, Stainless steel <Valve open>
VXD2E to 2G CAC408 When coil !4 is de-energized, (already closed) pilot valve
3 Diaphragm assembly VXD2A to 2G Stainless steel, NBR, FKM, EPDM A is open, pressure in pressure chamber B decreases,
4 Spring VXD2A to 2G Stainless steel and main valve C is open.
5 O-ring VXD2A to 2D NBR, FKM, EPDM
6 Buffer VXD2A, 2B PPS
7 Sleeve assembly Stainless steel, Resin (PPS)
8 Push rod assembly Resin (PPS), Stainless steel, NBR, FKM, EPDM
9 Stopper Stainless steel
10 O-ring A NBR, FKM, EPDM
VXD2A to 2G
11 O-ring B NBR, FKM, EPDM
12 Adapter Resin (PPS)
13 O-ring C NBR, FKM, EPDM
14 Solenoid coil Cu + Fe + Resin
137
VXD Series
For Air For information on handling One-touch
fittings and appropriate tubing, refer
to page 167 and KQ2 series One-touch
3 fittings in Best Pneumatics No. 7.
Dimensions/VXD2A Body Material: Resin (ø10, ø3/8", ø12)
Grommet d
e
C ≈ 300 U E
7.5 1.2
T
5.5
A
b
OUT IN
a
B
2xP
D Port size F I
≈ 4.5 K L ≈ 4.5 J
f
7.5 1.2
5.5
T
b
OUT IN
a
B
2xP
D Port size F I
≈ 4.5 K L ≈ 4.5 J
f
d
DIN terminal
e Cable ø6 to ø12 U E
C G1/2 V
(44)
7.5
31.5
1.2
5.5
T
A
b
OUT IN
a
B
2xP
Port size
D F I
≈4.5 K L ≈4.5 J
f
(mm)
Electrical entry
One-touch fitting Grommet (with surge
Model A B C D E F I J K L Grommet DIN terminal
P voltage suppressor)
T U T U T U V
91 58.5 45 50.5 64.5 52.5
VXD2 A3 ø10, ø3/8", ø12 (97) 22.5 30 45 20 6 13.5 41.5 25 33 (64.5)
27
(50.5) 30 (56)
One-touch fitting Mounting bracket dimensions
Model
P a b d e f
VXD2 A3 ø10, ø3/8", ø12 58 65 67 52 25.5
( ): Denotes the Normally Open (N.O.) dimensions.
138
Pilot Operated 2 Port Solenoid Valve VXD Series
Air
3
Dimensions/VXD2 A Body Material: Resin (ø10, ø3/8", ø12)
Conduit terminal d
e
34 (U±2) E
C (V±2)
VX2
VXK
32
1.2
7.5
VXD
25
VXZ
T
5.5
A
G1/2
VXS
b
OUT IN
a VXB
B
2xP
D F I
≈ 4.5 K L ≈ 4.5
Port size
J
VXE
f
VXP
Conduit d
e VXR
C ≈ 280 U E
23 VXH
7.5
1.2
VXF
G1/2 VX3
T
5.5
VXA
b
OUT IN
a
B
2xP
D F I
Port size
≈ 4.5 K L ≈ 4.5 J
f
Flat terminal d
e
C 11 U E
1.2
7.5
T
5.5
A
b
OUT IN
a
B
2xP
D Port size F I
≈ 4.5 K L ≈ 4.5 J
f
(mm)
Electrical entry
One-touch fitting Flat
Model A B C D E F I J K L Conduit terminal Conduit
P terminal
T U V T U T U
VXD2 A3 91 52.5 52.5 58.5
ø10, ø3/8", ø12 (97) 22.5 30 45 20 6 13.5 41.5 25 33 (58) 99.5 68.5 (58) 47.5
(64.5)
23
3
Dimensions/VXD2A Body Material: Aluminum, C37, Stainless Steel
Grommet
3
VXD2 A Port size 04 (1/2)
(With bracket)
C ≈ 300 U E
7.5
7.5 1.6 1.6
5.5
T
A
5.5
OUT IN
a
b
OUT IN
18
a
B
2xP
K L Port size F I
(D) J f
e 2xP
e f
d Port size
d
OUT IN
M
B
2xP
K L Port size F I
(D) J
OUT IN
M
B
2xP
K L Port size F I
(D) J
(mm)
M Electrical entry
Port size C37, Grommet (with surge
Model A B C D E F I J K L Grommet DIN terminal
Stainless Aluminum voltage suppressor)
P
steel body body type T U T U T U V
1/4, 3/8 88 4.5 11 37.5 22 24 55.5 42 47.5
VXD2 A3 22.5 30 50 20 25 25 27 30 64.5 52.5
1/2 (93.5) 5 13 42.5 27 30 (61) (47.5) (53)
3
Dimensions/VXD2 A Body Material: Aluminum, C37, Stainless Steel
Conduit terminal
(U±2) E
34 (V±2)
VX2
VXK
32
T
25
VXD
VXZ
A
M
G1/2
OUT IN
VXS
B
2xP
K L Port size F I VXB
(D) J
VXE
VXP
Conduit VXR
C ≈ 280 U E VXH
23
VXF
G1/2 VX3
T
A
3
VXA
OUT IN VXD2 A CF
M
3
B
Flat terminal
C 11 U E
OUT
T
A
OUT IN
M
B
2xP
K L Port size F I
(D) J
(mm)
M Electrical entry
Port size C37, Flat
Model A B C D E F I J K L Conduit terminal Conduit
P Stainless Aluminum terminal
steel body body T U V T U T U
1/4, 3/8 88 4.5 11 37.5 22 24 49.5 49.5 55.5
VXD2 A3 22.5 30 50 20 25 25 99.5 68.5 47.5 23
1/2 (93.5) 5 13 42.5 27 30 (55) (55) (61)
( ): Denotes the Normally Open (N.O.) dimensions.
Aluminum body is for air. Refer to page 118 for details.
141
VXD Series
For Air/Water/Oil
4
Dimensions/VXD2 B Body Material: C37, Stainless Steel
Grommet C ≈ 300 U E
T
A
OUT IN
M
B
f
2xP
Port size
F I
2 x ø8.5 J
2.6
e a
d b
K L
(D)
OUT IN
M
B
2xP
K L F I Port size
(D) J
Cable ø6 to ø12
U E
DIN terminal C G1/2 V
(44)
31.5
T
A
OUT IN
M
B
2xP
K L F I Port size
(D) J
(mm)
Electrical entry
Port size Grommet (with surge
Model A B C D E F I J K L M Grommet DIN terminal
P voltage suppressor)
T U T U T U V
96.5 61 47.5 53
VXD2 B4 3/8, 1/2
(102.5)
25.5 30 70 20 11.5 14 50 33 37 28 27 30 (59) 64.5 52.5
(67) (53.5)
Port size Mounting bracket dimensions
Model
P a b d e f
VXD2 B4 3/8, 1/2 47.5 71.5 57 34 39
( ): Denotes the Normally Open (N.O.) dimensions.
142
Pilot Operated 2 Port Solenoid Valve VXD Series
Air Water Oil
4
Dimensions/VXD2 B Body Material: C37, Stainless Steel
Conduit terminal
34 (U±2) 20
C (V±2)
VX2
32
VXK
VXD
25
T
G1/2
VXZ
A
OUT IN
VXS
M
B
VXB
K L F I 2xP
(D) J Port size VXE
VXP
Conduit
C ≈ 280 U E VXR
VXH
23
VXF
G1/2
VX3
T
A
OUT IN VXA
M
B
2xP
K L F I Port size
(D) J
Flat terminal C 11 U E
T
A
OUT IN
M
B
2xP
K L F I Port size
(D) J
(mm)
Electrical entry
Port size Flat
Model A B C D E F I J K L M Conduit terminal Conduit
P terminal
T U V T U T U
96.5 55 55 61
VXD2 B4 3/8, 1/2 (102.5)
25.5 30 70 20 11.5 14 50 33 37 28 (61) 99.5 68.5 (61) 47.5 (67) 23
5 6
Dimensions/VXD2 C /2D Body Material: C37, Stainless Steel
Grommet C ≈ 300 U E
T
A
OUT IN
M
B
2xP
f
Port size
2 x ø8.5
e F I
2.6
d J
K L a
(D) b
OUT IN
M
B
2xP
K L F I Port size
(D) J
Cable ø6 to ø12 U E
DIN terminal C
G1/2 V
(44)
31.5
T
A
OUT IN
M
B
2xP
Port size
K L F I
(D) J
(mm)
Electrical entry
Port size Grommet (with surge
Model A B C D E F I J K L M Grommet DIN terminal
P voltage suppressor)
T U T U T U V
107.5 68.5 27 55 60.5 64.5 52.5
VXD2 C5 3/4 29 30 71 20 4.5 17 51 32.5 38.5 35 (61) 30
(113.5) (74.5) (66.5)
126.5 82.5 29.5 69
VXD2 D6 1 33 35 95 22 4.5 20 59.5 45.5 49.5 42 32.5 74.5 67 55
(134.5) (90.5) (77) (82.5)
Port size Mounting bracket dimensions
Model
P a b d e f
VXD2 C5 3/4 50.5 77.5 74 51 45.5
VXD2 D6 1 55.5 85.5 81 58 49.5
( ): Denotes the Normally Open (N.O.) dimensions.
144
Pilot Operated 2 Port Solenoid Valve VXD Series
Air Water Oil
5 6
Dimensions/VXD2C /2D Body Material: C37, Stainless Steel
Conduit terminal 34 (U±2) E
C (V±2)
VX2
32
VXK
25
VXD
G1/2
A
VXZ
OUT IN
VXS
M
B
VXB
K L F I 2xP
(D) J Port size VXE
C U E
VXP
Conduit ≈ 280
VXR
23
VXH
G1/2
VXF
T
A
OUT IN
M VX3
VXA
B
2xP
Port size
K L F I
(D) J
Flat terminal C 11 U E
T
A
OUT IN
M
B
2xP
Port size
K L F I
(D) J
(mm)
Electrical entry
Port size Flat
Model A B C D E F I J K L M Conduit terminal Conduit
P terminal
T U V T U T U
107.5 62.5 62.5 68.5
VXD2 C5 3/4 (113.5)
29 30 71 20 4.5 17 51 32.5 38.5 35 (68.5) 99.5 68.5 (68.5) 47.5 (74.5) 23
126.5 76.5 76.5 82.5
VXD2 D6 1 (134.5) 33 35 95 22 4.5 20 59.5 45.5 49.5 42 (84.5) 102 71 (84.5) 50 (90.5) 25.5
Port size Mounting bracket dimensions
Model
P a b d e f
VXD2 C5 3/4 50.5 77.5 74 51 45.5
VXD2 D6 1 55.5 85.5 81 58 49.5
( ): Denotes the Normally Open (N.O.) dimensions.
145
VXD Series
For Air/Water/Oil
7 8 9
Dimensions/VXD2 E /2 F /2G Body Material: CAC408
Grommet C ≈ 300 U E
øR
T
A
IN OUT
øN
SMC
8 x ø18
B
Q F øS
D
øR
T
A
IN OUT
øN
SMC
8 x ø18
B
Q F øS
D
øR
T
A
IN OUT
øN
SMC
B
8 x ø18
Q F øS
D
(mm)
Electrical entry
Applicable Grommet (with surge
Model A B C D E F N Q R S Grommet DIN terminal
flange voltage suppressor)
T U T U T U V
168 90 76 82
VXD2 E7 32A
(176) 67.5 35 160 22 51.5 135 12 100 36
(98) 29.5
(84) 32.5 (90) 67 55
179.5 70 98.5 85 90.5
VXD2 F8 40A
(187.5)
40 170 24.5 54.5 140 14 105 42
(106.5)
32
(93) 35 (98.5)
69.5 57.5
192.5 77.5 104 90.5 96
VXD2G9 50A
(200.5)
40 180 24.5 59 155 14 120 52
(112)
32
(98.5) 35 (104)
69.5 57.5
7 8 9
Dimensions/VXD2E /2F /2G Body Material: CAC408
Conduit terminal (U±2) E
C (V±2)
32
VX2
25
G1/2
VXK
øR
T
VXD
A
IN OUT
VXZ
øN
SMC
8 x ø18
VXS
B
VXB
Q F øS
D VXE
VXP
Conduit C ≈ 280 U E
VXR
VXH
23
G1/2
øR VXF
T
VX3
A
IN OUT
øN
SMC
VXA
8 x ø18
B
Q F øS
D
Flat terminal C 11 U E
øR
T
A
IN OUT
øN
SMC
8 x ø18
B
Q F øS
D
(mm)
Electrical entry
Applicable Flat
Model A B C D E F N Q R S Conduit terminal Conduit
flange terminal
T U V T U T U
VXD2 E7 32A 168 67.5 84 84 90
(176) 35 160 22 51.5 135 12 100 36 102 71 50 25.5
(92) (92) (98)
179.5 92.5 92.5 98.5
VXD2 F8 40A (187.5) 70 40 170 24.5 54.5 140 14 105 42 (100.5) 104.5 73.5 (100.5) 52.5 (106.5) 28
192.5 98 98 104
VXD2 G9 50A (200.5) 77.5 40 180 24.5 59 155 14 120 52 (106) 104.5 73.5 (106) 52.5 (112) 28
( ): Denotes the Normally Open (N.O.) dimensions.
147
VXD Series
For Heated water/High temperature oil
3
Dimensions/VXD2A Body Material: C37, Stainless Steel (1/4, 3/8, 1/2)
Grommet
≈ 300 U E
C
(42) ≈ 40
2
For Heated water/
T High temperature oil
A
Full-wave rectifier
OUT IN
VXD2 A3 Port size 04 (1/2)
b
a
M
(With bracket)
B
K L 2xP F I
Port size
(D) J
1.6
e f
d
OUT IN
18
a
f
Conduit terminal e
2xP
(U±2) E d
Port size
34 (V±2)
32
3 C
VXD2 A F
25
3
Note) Only the VXD2 A with port size of 04 (1/2)
T
G1/2
OUT IN
2 x M4 x 0.7
B
Thread depth 8
2xP
K L Port size F I
18
(D) J
Conduit
≈ 280 U E
C
(42) ≈ 45
23
G1/2
For Heated water/
T
A
2xP
K L Port size F I
(D) J
(mm)
Electrical entry
Model Port size A B C D E F I J K L M Grommet Conduit terminal Conduit
P
T U T U V T U
1/4, 3/8 88 4.5 11 37.5 22 55.5 49.5 49.5
VXD2 A3 (93.5)
22.5 30 50 20 25 25 27 108 77 47.5
1/2 5 13 42.5 27 (61) (55) (55)
4
Dimensions/VXD2 B Body Material: C37, Stainless Steel
Grommet ≈ 300 U E
C (42) ≈ 40
T
Full-wave rectifier
VXK
A
OUT IN
VXD
M
B
2xP
VXZ
f
Port size
2 x ø8.5 F I
VXS
2.6
e J
d a
K L b VXB
(D)
VXE
VXP
DIN terminal U E
VXR
Cable ø6 to ø12
G1/2 V
C VXH
VXF
(44)
31.5
VX3
VXA
T
A
OUT IN
M
B
2xP
K L F I Port size
(D) J
(mm)
Electrical entry
Model Port size Grommet DIN terminal
A B C D E F I J K L M
P
T U T U V
96.5 61 53
VXD2 B4 3/8, 1/2 (102.5) 25.5 30 70 20 11.5 14 50 33 37 28 (67) 27 (59) 64.5 52.5
4
Dimensions/VXD2 B Body Material: C37, Stainless Steel
Conduit terminal
34 (U±2) E
C (V±2)
32
25
T
A
G1/2
OUT IN
M
B
K L F I 2xP
(D) J Port size
Conduit ≈ 280 U E
C (42) ≈ 45
23
G1/2
T
M
B
2xP
K L F I Port size
(D) J
(mm)
Electrical entry
Model Port size Conduit terminal Conduit
A B C D E F I J K L M
P
T U V T U
96.5 55 55
VXD2 B4 3/8, 1/2 (102.5) 25.5 30 70 20 11.5 14 50 33 37 28 (61) 108 77 (61) 47.5
( ): Denotes the Normally Open (N.O.) dimensions.
150
Pilot Operated 2 Port Solenoid Valve VXD Series
Heated High
water temperature oil
5 6
Dimensions/VXD2 C /2D Body Material: C37, Stainless Steel
Grommet
≈ 300 U E
C (42) ≈ 40
VX2
For Heated water/
High temperature oil
Full-wave rectifier VXK
T
A
OUT IN
VXD
M
B
VXZ
f
Port size
F I
2xP VXS
2 x ø8.5
e J
VXB
2.6
d a
K L b
(D)
VXE
VXP
DIN terminal U E VXR
Cable ø6 to ø12
C
G1/2 V
VXH
(44)
VXF
31.5
VX3
VXA
T
A
OUT IN
M
B
2xP
F I Port size
K L
(D) J
(mm)
Electrical entry
Model Port size Grommet DIN terminal
A B C D E F I J K L M
P
T U T U V
107.5 68.5 60.5
VXD2 C5 3/4 29 30 71 20 4.5 17 51 32.5 38.5 35 (74.5) 27 (66.5) 64.5
52.5
(113.5)
126.5 82.5 74.5
VXD2 D6 1 (134.5) 33 35 95 22 4.5 20 59.5 45.5 49.5 42 (90.5) 29.5 (82.5) 67 55
5 6
Dimensions/VXD2 C /2D Body Material: C37, Stainless Steel
Conduit terminal (U±2) E
34
C (V±2)
32
25
T
G1/2
A
OUT IN
M
B
K L F I 2xP
(D) J Port size
Conduit ≈ 280 U E
C (42) ≈ 45
23
G1/2
For Heated water/
T
Full-wave rectifier
OUT IN
M
B
2xP
K L F I Port size
(D) J
(mm)
Electrical entry
Model Port size Conduit terminal Conduit
A B C D E F I J K L M
P
T U V T U
107.5 62.5 62.5
VXD2 C5 3/4
(113.5)
29 30 71 20 4.5 17 51 32.5 38.5 35
(68.5) 108
77
(68.5) 47.5
126.5 76.5 110.5 79.5 76.5
VXD2 D6 1
(134.5)
33 35 95 22 4.5 20 59.5 45.5 49.5 42
(84.5) (84.5) 50
( ): Denotes the Normally Open (N.O.) dimensions.
152
Pilot Operated 2 Port Solenoid Valve VXD Series
Heated High
water temperature oil
7 8 9
Dimensions/VXD2 E /2 F /2G Body Material: CAC408
Grommet ≈ 300 U E
C
(42) ≈ 40
VX2
For Heated water/
High temperature oil
øR VXK
T
Full-wave rectifier
VXD
A
IN OUT
øN
SMC
VXZ
B
VXS
8 x ø18
Q F øS VXB
D
VXE
DIN terminal C
Cable ø6 to ø12 U E VXP
G1/2 V
(44) VXR
31.5
VXH
VXF
øR VX3
T
VXA
A
IN OUT
øN
SMC
B
8 x ø18
Q F øS
D
(mm)
Electrical entry
Model Applicable
A B C D E F N Q R S Grommet DIN terminal
flange
T U T U V
168 90 82
VXD2 E7 32A
(176)
67.5 35 160 22 51.5 135 12 100 36 (98)
29.5
(90)
67 55
179.5 98.5 90.5
VXD2 F8 40A 70 40 170 24.5 54.5 140 14 105 42 (106.5)
32
(98.5)
69.5 57.5
(187.5)
192.5 104 96
VXD2 G9 50A
(200.5)
77.5 40 180 24.5 59 155 14 120 52 (112) 32
(104)
69.5 57.5
7 8 9
Dimensions/VXD2 E /2 F /2G Body Material: CAC408
Conduit terminal
(U±2) E
C (V±2)
32
25
G1/2
øR
A
IN OUT
øN
SMC
B
Q F 8 x ø18
D
øS
Conduit
≈ 280 U E
C (42) ≈ 45
23
G1/2
For Heated water/
High temperature oil øR
T
Full-wave rectifier
A
IN OUT
øN
SMC
B
8 x ø18
Q F øS
D
(mm)
Electrical entry
Model Applicable
A B C D E F N Q R S Conduit terminal Conduit
flange
T U V T U
168 84 84
VXD2 E7 32A
(176)
67.5 35 160 22 51.5 135 12 100 36
(92)
110.5 79.5
(92) 50
179.5 92.5 92.5
VXD2 F8 40A
(187.5)
70 40 170 24.5 54.5 140 14 105 42
(100.5)
113 82
(100.5) 52.5
192.5 98 98
VXD2 G9 50A
(200.5)
77.5 40 180 24.5 59 155 14 120 52
(106)
113 82
(106) 52.5
Replacement Parts
DIN Connector Part No.
<Coil Insulation Type/Class B> <Coil Insulation Type/Class H>
Electrical option Rated voltage Connector part no. Electrical option Rated voltage Connector part no.
24 VDC 24 VDC GDM2A-G-S5 VX2
12 VDC 100 VAC
100 VAC 110 VAC VXK
110 VAC 200 VAC
None
200 VAC
C18312G6GCU
None 220 VAC
GDM2A-R VXD
220 VAC 230 VAC
230 VAC 240 VAC VXZ
240 VAC 24 VAC
24 VAC 48 VAC VXS
48 VAC 24 VDC GDM2A-G-Z5
24 VDC GDM2A-L5 100 VAC GDM2A-R-L1 VXB
12 VDC GDM2A-L6 110 VAC GDM2A-R-L1
100 VAC GDM2A-L1 200 VAC GDM2A-R-L2 VXE
110 VAC GDM2A-L1 With light 220 VAC GDM2A-R-L2
With light
200 VAC GDM2A-L2 230 VAC GDM2A-R-L2 VXP
220 VAC GDM2A-L2 240 VAC GDM2A-R-L2
230 VAC GDM2A-L2 24 VAC GDM2A-R-L5 VXR
240 VAC GDM2A-L2 48 VAC GDM2A-R-L5
24 VAC GDM2A-L5 VXH
48 VAC GDM2A-L15
VXF
155 B
VXD Series
Glossary of Terms
IP
Second characteristic numeral
First characteristic numeral 3.4
First Characteristics: 8
Degrees of protection against solid foreign objects
0 Non-protected
1 Protected against solid foreign objects of 50 mmø and greater
0.8
156
VXD Series
Solenoid Valve Flow Rate Characteristics
(How to indicate flow rate characteristics)
157
VXD Series
1 0.5
0.9
b = 0.1 0.6
0.8
0.2
0.7
Flow rate ratio
0.3
0.6
0.4
0.5
0.4
Example
0.3 P1 Equipment P2
0.2 C, b
Q
0.1
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Pressure ratio (P2 + 0.1) / (P1 + 0.1)
Graph (1) Flow rate characteristics
(4) Test method
Attach a test equipment with the test circuit shown in Fig. (1) while maintaining the upstream pressure to a
certain level which does not go below 0.3 MPa. Next, measure the maximum flow to be saturated in the first
place, then measure this flow rate at 80%, 60%, 40%, 20% and the upstream and downstream pressure. And
then, obtain the sonic conductance C from this maximum flow rate. In addition, calculate b using each data of
others and the subsonic flow formula, and then obtain the critical pressure ratio b from that average.
Pressure gauge or
pressure convertor
Thermometer Differential pressure gauge or
Pressure control differential pressure converter
ød1
equipment
ød3 ≥3d1 Flow control
3d3
valve
ød2
Air Filter Shut off ≥10d3 10d1 3d1 10d2 3d2 Flow meter
supply valve
Pipe for measuring Equipment
temperature for test
Pipe for Pipe for
measuring measuring
pressure in the pressure in the
upstream side downstream side
Fig. (1) Test circuit based on ISO 6358: 1989, JIS B 8390: 2000
158
Solenoid Valve Flow Rate Characteristics VXD Series
159
VXD Series
Upstream pressure
50 50 Water flow rate Q0 [L/min] (When Kv = 1)
P1 = 1 MPa
40 40
P1 = 0.8 MPa
30 30
P1 = 0.6 MPa
Example 2
20 20
P1 = 0.5 MPa P1 = 0.4 MPa
Example 1
10 10
P1 = 0.3 MPa
5 P1 = 0.2 MPa 5
4 P1 = 0.1 MPa 4
3 3
2 2
1 1
0.001 0.002 0.003 0.004 0.01 0.02 0.03 0.04 0.1
161
VXD Series
Flow Rate Characteristics
Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to pages 157 through to 161.
For Air (Orifice diameter: ø10 mm, ø15 mm, ø20 mm, ø25 mm)
Minimum operating pressure differential origin line How to read the graph
1.0 The sonic range pressure to generate a
Upst
re am flow rate of 6000 L/min (ANR) is as follows.
pre For a ø15 orifice (VXD240/Port size 3/8),
0.9 ssu
r eo P1 ≈ 0.57 MPa,
fv
alv for a ø20 orifice (VXD250/Port size 3/4),
e
0.8 P1
Downstream pressure of valve (P2) [MPa]
.0
0.7
M
0.8
Warning
Pa
ic
on
bs
0.6 0.7 Su In the area located left to the
al
itic re
Cr ssu minimum operating pressure
0.5
0.6 pre
differential origin line in the flow
0.5 nic rate characteristics table, the
0.4 So
0.4
minimum operating pressure is
not generated. Do not use the
0.3
0.3 product in this area as this may
cause operation failure (valve
0.2
0.2 opening failure, valve closing
failure) or damage of the valve.
0.1 0.1 Select valves with suitable size.
For Air (Orifice diameter: ø35 mm, ø40 mm, ø50 mm)
Minimum operating pressure (P1 + 1.033) = (1 to 1.89)(P2 + 1.033)
1.0 differential origin line
Ups
trea
mp
0.9 res
su
re
of
va
l ve
0.8 P
Downstream pressure of valve (P2) [MPa]
1
≈
0.9
1.
0.7
0M
Pa
0.8
ic
on
0.6 bs
Su
0.7 al
itic re
Cr ssu
0.5
0.6 pre
nic
0.5 So
0.4
0.4
0.3
0.3
0.2
0.2
0.1
0.1
162
Flow Rate Characteristics VXD Series
For Water
1,000 How to read the graph
49 The pressure differential to generate a
Cv = flow rate of 100 L/min water is as follows.
ø50
size 2 For a ø15 orifice (VXD242/Port size 1/2),
500 Port 31 VX2
Cv = ∆P ≈ 0.16 MPa,
400 ø40
ize 1 1/2 2 3
12 .5 for a ø20 orifice (VXD252),
Cv =
300 Port s ø35 ø25
Cv = ∆P ≈ 0.055 MPa, VXK
1 1/4 1 9.5
size size Cv = for a ø25 orifice (VXD262),
Port Port ø20
200 size
3/4 ∆P ≈ 0.032 MPa VXD
Port
VXZ
Flow rate Q [L/min]
100 5.5
Cv =
1/2
ø15 VXS
size
Port 4.5
Cv =
3/8
ø15 VXB
50 size
Port 2.4
Cv =
40
/2
ø10 VXE
3/8,1
30 size
Port 1 .9
Cv =
1/4
ø10 VXP
20 size
Port
VXR
10 VXH
0.02 0.03 0.032 0.04 0.05 0.06 0.07 0.08 0.09 0.1 0.16 0.2 0.3 0.4 0.5
0.055
Pressure differential ∆P = (P1 − P2) [MPa]
VXF
VX3
VXA
163
VXD Series
Specific Product Precautions 1
Be sure to read this before handling the products.
Refer to back page 50 for Safety Instructions and pages 17 to 19 for 2 Port Solenoid
Valve for Fluid Control Precautions.
Design Selection
Design Warning
1. Cannot be used as an emergency shutoff valve etc. 2. Fluid
The valves presented in this catalog are not designed for safety 1) Type of fluid
applications such as an emergency shutoff valve. If the valves Select an appropriate valve with reference to the table below
are used in this type of system, other reliable safety assurance for the general fluid. Before using a fluid, check whether it is
measures should also be adopted. compatible with the materials of each model by referring to
2. Extended periods of continuous energization the fluids listed in this catalog. Use a fluid with a kinematic
The solenoid coil will generate heat when continuously viscosity of 50 mm2/s or less.
energized. Avoid using in a tightly shut container. Install it in a If there is something you do not know, please contact SMC.
well-ventilated area. Furthermore, do not touch it while it is Applicable fluid
being energized or right after it is energized. For Air Air
3. Liquid rings For Water Air/Water
In cases with a flowing liquid, provide a bypass valve in the For Oil Air/Water/Oil
system to prevent the liquid from entering the liquid seal circuit. For Heated water Air(up to 99°C)/Water/Heated water
For High temperature oil Air(up to 99°C)/Water/High temperature oil
4. Actuator drive
When an actuator, such as a cylinder, is to be driven using a 2) Flammable oil, Gas
valve, take appropriate measures to prevent potential danger Do not use the product with combustion-supporting or flam-
caused by actuator operation. mable fluids.
3) Corrosive gas
5. Pressure (including vacuum) holding Cannot be used since it will lead to cracks by stress corrosion
It is not usable for an application such as holding the pressure or result in other incidents.
(including vacuum) inside of a pressure vessel because air
leakage is entailed in a valve. 4) Depending on water quality, a brass body can cause
corrosion and internal leakage may occur. If such abnormali-
6. When the conduit type is used as equivalent to an ties occur, exchange the product for a stainless steel body.
IP65 enclosure, install a wiring conduit etc. 5) Use an oil-free specification when any oily particle must not
7. When an impact, such as water hammer etc., caused enter the passage.
by the rapid pressure fluctuation is applied, the 6) Applicable fluid on the list may not be used depending on the
solenoid valve may be damaged. Give an attention to operating condition. Give adequate confirmation, and then
it. determine a model, just because the compatibility list shows
the general case.
3. Fluid quality
<Air>
Selection 1) Use clean air.
Do not use compressed air that contains chemicals, synthetic
A 164
VXD Series
Specific Product Precautions 2
Be sure to read this before handling the products.
Refer to back page 50 for Safety Instructions and pages 17 to 19 for 2 Port Solenoid
Valve for Fluid Control Precautions.
Selection Selection
Caution
1. Leakage voltage
When the solenoid valve is operated using the controller, etc.,
the leakage voltage should be the product allowable leakage
voltage or less. Particularly when using a resistor in parallel
with a switching element and using a C-R element (surge
voltage suppressor) to protect the switching element, take
note that leakage current will flow through the resistor, C-R
element, etc., creating a possible danger that the valve may
not turn off.
Switching element
Leakage voltage
OFF
C R
Power supply
SOL.
Leakage current
Disassembly/Assembly Procedures
Caution
1. Before disassembling, be sure to shut off the power <N.C.> <N.O.>
supply and pressure supply, and then release the
Mounting screw
residual pressure.
Disassembly
Mounting screw
<N.C.>
1) Loosen the mounting screws.
The coil assembly, stopper, return spring, armature assembly Coil assembly
and body can be removed.
O-ring A
<N.O.>
1) Loosen the mounting screws. Coil assembly
The coil assembly, push rod assembly, O-rings, adapter and O-ring B
body can be removed.
Assembly Stopper
Adapter
<Common to N.C. and N.O.>
1) Mount the components on the body in the reverse order of Return spring
disassembly. Push rod assembly
2) Push the coil assembly against the body and tighten the
screws two or more rounds diagonally (Fig. 2) in the status Armature assembly
that there are no gaps between the coil assembly and body Spring
(Fig. 1).
Tighten the screws in the order of “1→2→3→4→1→2→3→4”. O-ring C
Proper Tightening Torque N·m
VXD23A
VXD24B 0.5
VXD25C
VXD26D
VXD27E
0.7
VXD28F Aluminum
Resin body Metal body (C37 )
VXD29G Stainless steel
Flange
No gaps
1 3
Body
4 2 Body
Fig. 1 Fig. 2
∗ After tightening the screws, make sure that there are no gaps between the
coil and body (Fig. 1).
∗ After the disassembly and assembly have been completed, make sure
that no leak occurs from the seal. Additionally, when restarting the valve,
make sure that the valve operates correctly after checking the safety.
166
VXD Series
Specific Product Precautions 4
Be sure to read this before handling the products.
Refer to back page 50 for Safety Instructions and pages 17 to 19 for 2 Port Solenoid
Valve for Fluid Control Precautions.
Warning Warning
1. Do not use in an atmosphere having corrosive 4. If the product is used in the conditions in which rapid
gases, chemicals, sea water, water, water vapor, or decrease in the inlet pressure of the valve and rapid
where there is direct contact with any of these. increase in the outlet pressure of the valve are
2. Do not use in explosive atmospheres. repeated, excessive stress will be applied to the
3. Do not use in locations subject to vibration or diaphragm, which causes the diaphragm to be dam-
impact. aged and dropped, leading to the operation failure of
the valve. Check the operating conditions before
4. Do not use in locations where radiated heat will be use.
received from nearby heat sources.
5. Employ suitable protective measures in locations Electrical Connections
where there is contact with water droplets, oil or
welding spatter, etc.
Caution
Maintenance Grommet
Class B coil: AWG20 Insulator O.D. 2.6 mm
Warning Class H coil: AWG18 Insulator O.D. 2.1 mm
Electrical Connections
— 2: −
(+)
Grounding VX3
+ mark
– mark
1 2
+ –
A VXA
Terminal no. 1 2 G1/2
Round head
DIN terminal +(–) –(+) combination screw Tightening
torque
∗ There is no polarity. M3 Tightening torque 0.5 to 0.6 N·m
0.5 to 0.6 N·m Conduit terminal
Conduit terminal View A-A
Disassembly (Internal connection diagram)
1. Loosen the mounting screw, and remove the terminal cover
Conduit
from the conduit terminal.
Wiring When used as an IP65 equivalent, use seal to install the wiring
1. Insert the cable into the conduit terminal. conduit. Also, use the tightening torque below for the conduit.
2. Loosen the screw with UP terminal of the conduit terminal, then Class B coil: AWG20 Insulator O.D. 2.5 mm
insert the core wire or the crimped terminal of the lead wire into Class H coil: AWG18 Insulator O.D. 2.1 mm
the terminal, and securely fix it with the screw with UP terminal. Lead wire
Note 1) Tighten the screw to a torque of between 0.5 and 0.6 N·m.
Assembly q
1. Insert the gasket into the conduit terminal, and then clamp the
terminal cover with the mounting screw.
Note 1) Tighten the screw to a torque of between 0.5 and 0.6 N·m.
w
Note 2) When changing the orientation of the conduit terminal,
carry out the following procedure.
Wiring conduit Seal
1. Apply a tool (monkey wrench, spanner, etc.) to the width
(Connection G1/2 Tightening torque 0.5 to 0.6 N·m)
across flats of the conduit terminal, and turn the terminal in
the counterclockwise direction.
Lead wire color Description Part no.
2. Loosen the lock nut. Rated voltage
q w Seal VCW20-15-6
3. Turn the conduit terminal in the clamping direction (clockwise
direction) to about 15° ahead of the desired position. DC Black Red Note) Please order separately.
4. Turn the lock nut by hand to the coil side until it is lightly tightened. 100 VAC Blue Blue
5. Apply a tool to the width across flats of the conduit terminal, 200 VAC Red Red
and turn it to the desired position (through an angle of about Other AC Gray Gray
15°) so as to clamp the conduit terminal. ∗ There is no polarity.
Note) When changing the orientation by applying additional
tightening force to the conduit terminal from the factory-
set position, turn no more than one half a turn.
169 B
VXD Series
Specific Product Precautions 7
Be sure to read this before handling the products.
Refer to back page 50 for Safety Instructions and pages 17 to 19 for 2 Port Solenoid
Valve for Fluid Control Precautions.
Electrical Circuits
Caution
[DC circuit]
Grommet, Flat terminal Grommet, DIN terminal,
Conduit terminal, Conduit
Varistor
1 (+, –) 1 (+, –)
SOL. SOL.
2 (–, +) 2 (–, +)
SOL.
2 (–, +)
Light
[AC circuit]
∗ For AC, the standard product is equipped with surge voltage suppressor.
Grommet, DIN terminal, DIN terminal, Conduit terminal
Conduit terminal, Conduit Varistor
Rectifier Rectifier
Varistor element element
1 1
SOL. SOL.
2 2
Light
Note 1) Coil for DIN terminal H type with AC voltage does not have
full-wave rectifier. Full-wave rectifier is built in the DIN connector.
Refer to page 155 to order it as an accessory.
One-touch Fitting
Caution
For information on handling One-touch fittings and
appropriate tubing, refer to page 167 and the KQ2
series One-touch fittings in Best Pneumatics No. 7.
170