SNV 2020

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Safety Switching Devices

Emergency-Stop Relay
Basic Unit
According to EN 60204 - 1 and EN 954 - 1
Single or Dual Channel E-Stop are Possible
3 Non-Delayed, 1 Off-Delayed Enabling Current Paths
SNV 2020 EN 60204 --1 For Stop Category 0/1
With /Without RESET Monitoring
EN 954 --1 Safety Category 4/3
Rated Voltage in the E-Stop Control Circuit: 24 V DC

1 SNV 2020-17 For Example


u Protection of persons and machines
u Monitoring of sliding safety gates
u Use with programmable logic control systems
A1 S11 S12 S12 S22 13 23 33 41 57 u Protection in assembly lines
SCHLEICHER SUPPLY A1 S11 S12 S12 S22 13 23 33 41 57
+
SNV 2020
6s
8s
10s K2 S22
K5 Function
K3
4s 15s
3s 20s
S12 K4 Following application of the supply voltage to the terminals A1/A2, and
K3 S12
2s 25s Y2
K2 if the E-Stop switch is not actuated, relay K1 is energized by the RESET
1s 0s 30s K4 K1 switch. The presence of the external SUPPLY voltage is indicated by an LED
t + which goes out in case of a fault (e.g. short-circuit or ground fault in the
K5 S33 S34 Y1 Y2 14 24 34 42 58 A2 wiring of the E-Stop circuit), even if the supply voltage is still applied. As
S33 S34 Y1 Y2 14 24 34 42 58 A2 long as the RESET switch (S34 with RESET switch monitoring) stays closed
(or in case of short-circuit or ground fault in the RESET switch), the enabling
current paths cannot be activated. Without the RESET switch monitoring,
the terminal Y2 must be used. The contacts of relay K1 trigger the relays
K2/K4 and K3/K5. These become self-locking through their own contacts.
Simultaneously, the contacts of relays K2/K4 and K3/K5 de-energize relay
K1, which goes into its off-position after a drop-out delay time tR1. After
this switch-on phase, the three non-delayed enabling current paths which
are intended for the outputs (13/14, 23/24, 33/34) and the delayed
enabling current path (57/58) are closed. The control contact (41/42) is
Function Diagram FD 0369 W1 opened. Four LEDs, which are assigned to the internal safety relays K2,
K3, K4 and K5, provide a display of the actual status. The SNV 2020-17
SNV 2020-17 is available with two ranges of settings for the off-delay times. Each version
A1/A2 Supply voltage, LED SUPPLY can be set in (12) steps of 0 to 3 seconds, or 0 to 30 seconds..
S12, S22 E-Stop If the E-Stop switch is activated, the current supplies for relays K2 and K3
Y1, Y2 Feedback circuit are disconnected. The enabling current paths at the output are opened
S34 RESET and the control contact is closed. The delayed enabling current path 57/58
13/14, 23/24, 33/34, LED K2, LED K3
remains closed. After the delay time has elapsed, relays K4 and K5 switch
back into their off-position and 57/58 opens.
57/58, LED K4, LED K5
41/42 Notes
tA = Response time
tA tA tR2 tR1 = Release time for K1 3 The off delay time is available in two different settings.
tM tR1 tR3 tR2 = Release time for K2, K3
tR3 = Adjustable off-delay time K4, K5 (0 to 30 s)
3 It is possible to delete the off delay time prematurely by interrupting the
tM = Minimum switch-on time supply voltage (A1).
3 To multiply the enabling current paths, use the expansion units
or external power contactors with positively guided contacts.

Connection Diagram KS 0369-1 W1


Dimension Diagram S 4-6
SNV 2020-17 for DIN-Rail acc. to EN 50022

A1 S11 S12 S12 S22 13 23 33 41 57


A1 A2 Y1 Y2 S12 S12 + +
K3
62,5

+ + +
60
75

K2
104,5
K1
4,5

K4
-- +
K5
80 5
82,5 108,5
90

K1 K2 K4 K3 K5

S11 S33 S34 Approvals Order Example


S33 S34 Y1 Y2 14 24 34 42 58 A2
SNV 2020-17 30 s 24 V AC/DC
SNV 2020-17 3 s 24 V AC/DC

Type End Range Rated Voltage


ET 96014

1.48
Relays and Automation Systems
Safety Switching Devices

SNV 2020-17

Application Example A 1089 Application Example A 1091

Single-Channel E-Stop Circuit without/with* RESET Monitoring Dual Channel E-Stop Circuit with RESET monitoring
L+ L+

E-Stop E-Stop

A1 A2 Y1
+
Y2 S12 S12
+ +
A1 S11 S12 S12 S22 13 23 33 41 57
+ +
K3
A1 A2 Y1 Y2 S12 S12
+ + +
A1 S11 S12 S12 S22 13 23 33 41 57
+ +
K3
1
K2 K2

K1 K1

K4 K4
-- + -- +
K5 K5

K1 K2 K4 K3 K5 K1 K2 K4 K3 K5

S11 S33 S34 S11 S33 S34


S33 S34 Y1 Y2 14 24 34 42 58 A2 S33 S34 Y1 Y2 14 24 34 42 58 A2
*) with
Reset RESET Monitoring RESET Feedback Circuit

M
M The dual channel E-Stop circuit switches off even if one of the two contacts of
The single channel E-Stop circuit complies with the requirements acc. to the E-Stop button does not open . If a fault occurs (e.g. the E-Stop contact
EN 60204 - 1. The E-stop circuit offers however no redundancy. When connected to S22 does not open), the safety circuit is activated by the second
the RESET switch is connected to the terminal Y2 (without RESET (redundant) contact S12. The enabling current paths 13/14, 23/24 and
monitoring), the unit can be enabled by actuating the RESET switch. 33/34 open. In case of short circuit to GND of the cables connected to the
Ground faults in the RESET circuits will be detected. E-Stop switch, the voltage present at S11/S33 is short circuited. The relays K2,
K3 and off-delayed K4,K5 switch back into their off-position and the PTC
switches off the short-circuit current after 3s. The RESET switch is monitored; i.e.
Application Example A 1090 the device is enabled only by releasing the switch (with the falling edge of the
RESET switch). If the RESET switch is closed before the supply is applied to
External Contact Expansion with RESET Monitoring terminals S12 and S22 or there is a short circuit in the cable, the enabling current
and Premature Time Reset paths remain open. If however, a short circuit in the RESET cable occurs when
L+ the Emergency-Stop Relay is already active the cyclic self checking feature of the
item will detect it when switching the supply OFF/ON. As a consequence, the
Control
E-Stop enabling current paths will not close and the safety function is guaranteed.
Time-Reset
Uext
A1 S11 S12 S12 S22 13 23 33 41 57 Application Example A 1092
A1 A2 Y1 Y2 S12 S12 + +

+ + + K3 Dual-Channel Safety Gate Monitoring


K2
L+
K1

K4
-- + Sliding
K5 Safety-Gate
closed

K1 K2 K4 K3 K5

S11 S33 S34 A1 S11 S12 S12 S22 13 23 33 41 57


S33 S34 Y1 Y2 14 24 34 42 58 A2 A1 A2 Y1 Y2 S12 S12 + +

+ + + K3
RESET
K2
K6
K1
Feedback Circuit
K4
K7 -- +
K5

M
If the number of enabled current paths is not sufficient, two external K1 K2 K4 K3 K5
contactors can be used for expansion. They are driven through one of the S11 S33 S34
enabling current paths of the SNV 2020-17. The function of the external S33 S34 Y1 Y2 14 24 34 42 58 A2
contactors is monitored by their own NC contacts connected in series to
the relay K1 (Y2). The contactors K6 and K7 must have positively guided RESET Feedback Circuit
contacts.
In order to match the off-delay time of the enabling current path 57/58
M
to the process cycle time, the off delay time can prematurely be set to 0
by switching off the supply voltage at A1. The position of the safety sliding gate is monitored through channel 1 (S12)
and channel 2 (S22). The SNV 2020-17 is activated through the RESET switch.
If the sliding safety gate opens, the Emergency-Stop Relays returns to its off-
position.The enabling current paths 13/14, 23/24, 33/34 open. If the safety
gate is closed again the Emergency-Stop Relay can be activated again through
the RESET switch.

1.49
Relays and Automation Systems
Safety Switching Devices

TECHNICAL DATA SNV 2020-17


FUNCTION According to EN 60204-1 Emergency - Stop Relay
Function Display 5 LEDs, green
Function Diagram FD 0369 W1

POWER SUPPLY DATA


Rated Voltage UN V AC/DC 24
Rated Consumption at 50 Hz and UN (AC) VA 11
Rated Consumption at 50 Hz and UN (AC) W 5,8

1 Rated Consumption at UN (DC)


Residual Ripple
Rated Frequency
W
Vss
Hz
4,8
2,4
50 to 60
1
Operating Voltage Range 0,8 to 1,1 x UN

CONTROL CIRCUIT only for supplying the control inputs


Control Output S11, S33 with respect to A2:
Line Resistance (Control Inputs) Ω ≤ 70
Rated Output Voltage V DC 24
Rated Current mA 90
Rated Short-Circuit Current IK max. mA 6000
Fuse PTC - Resistance
Response Time s 3
Recovery Time s 3

Control Inputs Y1/S34, Y2, S12, S22:


Rated Current Input K1, K2, K3 mA 45
Response Time tA K1, K2, K3, K4, K5 ms 25
Release Time tR1 Start-up Cycle K1 ms 80
Release Time tr for the E-Stop K2, K3 ms 8
Release Time tr for the E-Stop K4, K5 Selectable s 2 Setting Ranges
1. Setting Range 3s
adjustable in 12 steps:
0, 0.1, 0.2, 0.3, 0.4, 0.6, 0.8,
1, 1.5, 2, 2.5, 3 ± 10 %
2. Setting Range 30 s
adjustable in 12 steps:
0, 1, 2, 3, 4, 6, 8, 10, 15, 20,
25, 30 ± 10 %
Release Time tr for the E-Stop K4, K5 at t = 0 s ms 20
Minimum Switch-ON Time tM for K1 ms 35

OUTPUT CIRCUIT
Contact Equipment 3 N.O. Safety Contact
Stop-/Safety Category 0/4
1 N.O. Safety Contact
Off - Delayed
Stop-/Safety Category 1/3
1 N.C. Control Contact
Contact Type Forced Contact
Contact Material Ag - Alloy; Gold - Plated
Switching Voltage Un V AC/DC 230/230
Maximum Rated Current In per Contact A 6
Maximum Total Current for all Contacts A 18
Application Category According To EN 60947--5--1:1991 AC--15: Ue 230 V AC, Ie 4 A
DC--13: Ue 24 V DC, Ie 6 A
Short-Circuit Protection, Max. Fuse Element Class gG A 6
Permissible Switching Frequency Switching Cycle/h 3600
Mechanical Lifetime Switching Cycle 30 x 106

GENERAL DATA
Creepage and Clearance Distances Between Circuits
According to DIN VDE 0110 - 1:04.97: Rated Withstand Voltage kV 4
Over-Voltage Category III
Contamination Level 3 Outside 2 Inside
Design Voltage V AC 300
Test Voltage Ueff 50 Hz acc. to DIN VDE 0110 - 1, Table A.1 kV 2,21
Protection Class Housing/Terminals acc. to DIN VDE 0470 Sec. 1:11.92 IP 40/IP 20
Radiated Noise EN 50081--1:03.93, --2:03.94
Noise Immunity EN 50082--2:1995

Ambient Temperature, Working Range °C -- 25 to + 55


Dimension Diagram S 4- 6
Connection Diagram KS 0369 - 1 W1
Weight kg 0,57
Accessories Cover Z 29
Approvals BG, CSA, UL

GENERAL TECHNICAL SPECIFICATIONS Page i.11

1.50 1.x
Relays and Automation Systems