USER MANUAL MD77HR

F077052 - HEADING REPEATER

MD77HR-MA-v06r03
2022-10-16
ENGLISH
MD77HR
CONTENTS
1 MD77HR HEADING REPEATER ........................................................... 5
2 DOCUMENT ........................................................................................ 6
2.1 About This Manual .......................................................................................... 6
3 NOTICE ............................................................................................... 7
3.1 Copyright ......................................................................................................... 7
4 DESCRIPTION ..................................................................................... 8
5 PRINCIPLE OF OPERATION ................................................................ 9
6 APPLICATION ................................................................................... 10
7 SPECIAL FEATURES ......................................................................... 10
8 MAJOR DIMENSIONS ....................................................................... 11
9 INSTALLATION ................................................................................. 12
9.1 Parts List........................................................................................................ 12
9.2 Fitting the unit................................................................................................ 12
9.3 Pin Connections (by function)....................................................................... 13
9.4 Pin Identification ........................................................................................... 14
9.5 Typical Wiring Diagram ................................................................................. 14
10 COMMISSIONING THE SYSTEM ....................................................... 15
10.1 Product Registration ..................................................................................... 15
11 OPERATION ...................................................................................... 16
11.1 Operator Controls .......................................................................................... 16
11.2 Normal Operation .......................................................................................... 17
11.3 Indication: Loss of Data ................................................................................ 18
11.4 Automatic Baud Rate Detection .................................................................... 18
11.5 Heading Type Selection ................................................................................ 18
11.6 Test Function ................................................................................................. 18
12 MAINTENANCE AND FAULT-FINDING .............................................. 19
12.1 Maintenance .................................................................................................. 19
12.2 Fault-Finding .................................................................................................. 19
12.2.1 MD77HR does not operate ............................................................... 19
12.2.2 MD77HR aligns to 000° but does not follow the source heading .... 19
12.2.3 Display illumination not functioning ................................................. 19
12.2.4 Dial oscillating +/- 35 degrees, Alert Indication on or True and Mag
indication both on ............................................................................. 19
12.3 Technical Support ......................................................................................... 20

3
MD77HR
12.4 Reporting a Fault ............................................................................................20
13 SPECIFICATIONS .............................................................................. 21
13.1 Physical ..........................................................................................................21
13.2 Electrical .........................................................................................................21
13.3 Operational .....................................................................................................21
13.4 Environmental ................................................................................................22
13.5 Additional Information ...................................................................................22
14 SPARE PARTS AND ACCESSORIES................................................... 23
15 GROUNDING AND SHIELDING ........................................................... 24
16 SAFETY AND SECURITY.................................................................... 24
17 GLOSSARY OF TERMS ...................................................................... 25
18 ABOUT MARINE DATA ...................................................................... 26

4
MD77HR
1 MD77HR HEADING REPEATER

Bulkhead Bracket Mounted


(Option)

Rear View - Panel Mounted


(Standard)

5
MD77HR
2 DOCUMENT
2.1 About This Manual
This Manual provides installation, operating Instructions and fault-finding procedures for the
Marine Data MD77HR Heading Repeater.
After installation, this manual should remain with the vessel to which it relates.
This manual may also be made available in electronic Portable Document Format (PDF). In PDF
format, the following categories are all enabled as active hyperlink references: (1) The titles of
each section; (2) document cross-references; (3) the table of contents.
This document may therefore be navigated quickly and effectively by using a mouse or other
pointing device to activate each of these hyperlinks. This is a printer friendly document, designed
to be printed 2-sided as a booklet with A5 pages on A4 stock paper.

Document name: Date: Details: Author:

MD77HR-MA-v04r01 22-07-2013 First issue F. Celano


MD77HR-MA-v04r02 21-11-2013 Operating temp range amended F. Celano
MD77HR-MA-v04r03 12-03-2014 Heading Monitor section added F. Celano
MD77HR-MA-v04r04 08-04-2014 Conform; format; proof FC, JS
MD77HR-MA-v04r05 09-04-2014 Amend table 9.3; proof FC, JS
MD77HR-MA-v04r06 22-07-2014 HM removed; graphics amended; proof FC JS
MD77HR-MA-v04r07 09-12-2014 12-core cable option removed, 9.5 wiring diagram amended FC
MD77HR-MA-v04r08 27-03-2015 Compass Safe Distance amended FC
MD77HR-MA-v04r09 30-08-2016 Compass Safe Distance amended JS
MD77HR-MA-v05r00 12-09-2016 Section 11.9 removed; section 11.5 amended; table 9.3 updated;
front label updated; cross-reference errors fixed; amend section JS
13.2
MD77HR-MA-v05r01 03-01-2018 Update formatting JS
MD77HR-MA-v06r01 2019-11-19 Multiple changes across whole document TSI / PJY
MD77HR-MA-v06r02 2021-03-29 Baud rate, finishes, grammatical & image updates TSI
MD77HR-MA-v06r03 2022-10-16 Change MD69CB/W to MD96JCB TSI

6
MD77HR
3 NOTICE
3.1 Copyright
The copyright and all rights of a like nature in respect of this publication in any part of the world
are the property of Marine Data Systems Ltd. (Marine Data).
No part of this document may be reproduced or transmitted in any form or by any means, whether
electronic, mechanical, photocopying, recording or otherwise, nor stored in any information
retrieval system of any kind, nor used for tendering or manufacturing, nor communicated to any
other person without the written permission of Marine Data.
The recipient of this document, as its registered holder, must exercise due diligence in ensuring
that the above conditions are observed (Errors and Omissions Excepted).
Any enquiries relating to this document or its contents should be addressed, in writing, in the first
instance to Marine Data.

Marine Data Systems Ltd.


Vittlefields Technology Centre
Forest Road
NEWPORT
Isle of Wight
PO30 4LY
UNITED KINGDOM

tel: +44 (0)1983 822180


email: sales@marine-data.co.uk
web: www.marine-data.co.uk

Marine Data Systems Ltd. reserves the right to make changes to its products and
specifications without notice

7
MD77HR
4 DESCRIPTION
The MD77HR is a rotating dial Compass Heading Repeater. It is designed to display Ship’s
heading as part of a Gyro-Compass or Transmitting Magnetic Compass System, receiving data
via a NMEA 0183 digital transmission.
The MD77HR has a dial of 118 mm diameter marked in 1 degree increments with numeric values
every 10 degrees plus cardinal and inter-cardinal markers. The dial rotates one revolution for 360
degrees. A lubber-line is provided to allow the heading indicated by the dial to be read accurately.
The dial is back-lit with a red tint for easy reading. The illumination is dimmable to allow the
repeater to be viewed in any lighting condition from full sunlight to total darkness. The
illumination level is adjustable down to zero so that night vision is not affected. Dimming can be
controlled either by the front panel push buttons or by a remote electrical dimmer connection.
The MD77HR is provided with an interface panel with indicator LEDs showing equipment status
and a keypad giving the user control of illumination level and test functions.
The MD77HR gives indication of Heading Type (True or Magnetic) and indication of loss of valid
data condition.
Constructed in a robust aluminium enclosure and finished in Jet Black (RAL9005) Fine-texture
Powder Coat, the MD77HR is designed to complement existing marine navigation equipment.
Supplied for panel mounting as standard, an optional adjustable bulkhead mounting bracket is
available. Compact and rugged, the MD77HR offers a compact Heading Repeater solution for
locations where available space is limited.
The MD77HR Heading Repeater from Marine Data, designed to be easy to install and simple to
maintain.

8
MD77HR
5 PRINCIPLE OF OPERATION
The MD77HR accepts serial azimuth data from a Gyro-Compass or Transmitting Magnetic
Compass (TMC) in digital format using standard NMEA 0183 (IEC61162-1) True or Magnetic
sentences. The input is processed by electronic circuitry contained within the Repeater enclosure,
powered from 18 V to 32 V dc derived from the ship’s supply. Power consumption is low; typically
less than 4 watts.
An embedded micro-controller processes the received heading information and in turn drives a
stepper-motor connected to the dial. On application of power, the dial is rotated to align to a zero
reference position controlled by an optical switch. Subsequently, on reception of valid data, the
dial is driven to display the received heading. When updated heading information is transmitted
to the Repeater, the dial will then follow this new heading.
Sophisticated firmware embedded in the micro-controller monitors the received heading, user
controls and other control signals and provides control of dial, illumination and indicators.
Suppression circuitry and opto-isolation are used to provide protection for over-voltage and
reverse polarity as well as compliance with EMC and data transmission standards.

9
MD77HR
6 APPLICATION
The MD77HR displays True or Magnetic Heading Data transmitted from NMEA 0183 (IEC 61162-
1) compatible marine equipment (Gyro-Compass, TMC, EMC, GPS Compass etc.)
The following NMEA 0183 sentences (in priority order) may be used to display Heading:

Heading
Priority: Sentence and Description:
Type:
( $--THS, x.x, S*hh<CR><LF> )
1 THS
Heading True with Status (S = Status = “A”)
( $--HDT, x.x, T*hh<CR><LF> )
2 HDT
Heading True (Gyro-sourced True Heading Data)
( $--HDG, x.x, x.x, a, x.x, a*hh<CR><LF> )
Heading True (from Magnetic) (Heading Data corrected for the Earth’s
Magnetic Variation and the vessel’s Deviation)
3 HDG
( $--HDG, x.x, x.x, a, , a*hh<CR><LF> )
Heading Magnetic (Heading Data not corrected for the Earth’s Magnetic
Variation and the vessel’s Deviation)
( $--HDM, x.x, M*hh<CR><LF> )
4 HDM
Heading Magnetic

7 SPECIAL FEATURES
1. Compact Dial Type display of Heading
2. NMEA 0183 input with Automatic Baud Rate Selection
3. Automatic Prioritisation of Heading type: THS / HDT (True), HDG (Magnetic + Variation),
HDM (Magnetic)
4. Indication of Loss of Valid Heading Data
5. Local and Remote Dimming Control

10
MD77HR
8 MAJOR DIMENSIONS
All dimensions mm
Panel mounting and bulkhead mounting (option) shown here:

11
MD77HR
9 INSTALLATION
On delivery, carefully inspect the contents of the packing case. Note any damage or any missing
items. Determine whether a bulkhead mounting option or a panel mounting option is to be used
and ensure that the correct parts are included for your application.

9.1 Parts List


No.
Item: Description: MARINE DATA Part Number:
included:

1 MD77HR Heading Repeater 1 F077052


2 Panel Mounting Kit 1 CM71111

3 6 Core Data Cable (2.5 metres) 1 SS20001


4 Bulkhead Mounting Kit (1) F077100 (optional)

9.2 Fitting the unit


Inspect the mounting position for suitable clearance and cable access. For panel cut-out
dimensions, refer to section 8 MAJOR DIMENSIONS.
Secure the MD77HR in the chosen mounting position.
Review the system cable conductors and their function.
Identify the vessel’s wiring functions. It is recommended that a note be made of the vessel’s
wiring functions for future reference. Connect the MD77HR in accordance with table 9.3 Pin
Connections (by function).
The MD77HR is designed to use 24 V dc and accept a digital RS422 data signal using the NMEA
0183 protocol. Ensure all incoming supply and signal cables are either suitably insulated and/or
connected, or bonded to the vessel’s earth where appropiate.
Isolation and earthing requirements must comply with Lloyd’s Rules and Regulations VI
paragraph 1.13.2
There is an M4 stud located on the rear of the unit for local earth bonding.
CAUTION: Application of any voltage other than those stipulated in this product specification
may damage the compass repeater

Do not apply power yet.

12
MD77HR
9.3 Pin Connections (by function)
Cable core
Pin: Type: Function: Description:
colour 1:
0F

Positive
1 Input +24 V dc supply RD
(Main)

9 Input Negative 24 V dc supply return BK

Optional input for external dimmer:


0-24 V
0 V = Minimum Illumination
Rotary
2 Input 24 V = Maximum Illumination WH
Analogue
Isolate or connect to supply negative when not
Dimmer
used.

Factory option for a control input. Isolate or


10 Input SW_IN YE
connect to supply negative when not used.

3 Input RDA NMEA 0183 (IEC 61162-1) Data Input A GN

11 Input RDB NMEA 0183 (IEC 61162-1) Data Input B BU

Chassis
8 Chassis Screen SCN
Connection

1
IEC 60757 colour abbreviations

13
MD77HR
9.4 Pin Identification
Pin Idents of the 15-pin fixed D-type socket connector (view looking on the rear panel of the
MD77HR):

9.5 Typical Wiring Diagram


(shown with remote dimmer option)

14
MD77HR
10 COMMISSIONING THE SYSTEM
Ensure that the installation complies with section 9 INSTALLATION.
Apply system power (24 V dc) to the MD77HR.
The MD77HR Heading Repeater will initially align to 000° degrees; it will then adopt the heading
which is being transmitted from the heading source.
Verify that the MD77HR Heading Repeater follows the heading source when altering the vessel’s
heading.
If an error condition arises, then refer to section 12.2 Fault-Finding.
Ensure that the display lighting is set to a suitable level using the front panel dimmer control push
buttons.

10.1 Product Registration


Be sure to register your product online at www.marine-data.co.uk
Alternatively, fill out the product registration form and return it to Marine Data.
NOTE: It is the process of registration which activates the warranty.

15
MD77HR
11 OPERATION
11.1 Operator Controls

A. Test Button (In Conjunction with Acknowledge button)


B. Acknowledge Button
C. On (Green)
D. Alarm Indication (Red)
E. True Heading (Blue)
F. Magnetic Heading (Yellow)
G. Dimmer & Control
[Increase & Save Button]
H. Dimmer & Control
[Decrease & Exit Button]
I. Lubber Line
J. Back-lit Dial 000° - 359°
K. Sounder

I J K

A B C D E F G H

16
MD77HR
11.2 Normal Operation
In normal operation, the True Heading indicator (blue, BU) and Magnetic Heading (yellow, YE)
indicator are used to show the type of heading displayed.

• If True Heading is being displayed then the True Heading Indicator will be illuminated.

• If Magnetic Heading is being displayed the Magnetic Heading Indicator will be illuminated.

The Illumination Level of the Dial, Pointer and Indicators are adjusted using the buttons.

Pressing the button will increase the illumination level by one step; holding the button will
slowly increase the illumination to maximum.

Pressing the button will decrease the illumination level by one step; holding the button will
slowly decrease the illumination to minimum.
At the minimum illumination level the dial illumination is fully extinguished. However, active
indicators remain lit at a very low level to allow location of the panel controls in total darkness.

17
MD77HR
11.3 Indication: Loss of Data
If no data is received for more than 3 seconds then a No Data condition is indicated. To indicate
a No Data error the dial illumination will flash and the dial will oscillate approximately +35° and -
35° about the last valid heading received. The red alert indication is set.

The Loss of Data indication can be acknowledged by pressing the button for 0.5 seconds or
more. When the indication is acknowledged, the dial will stop rotating and return to the 000°
position. Both True and Magnetic indicators will be illuminated.
A single audible 'beep' will be given on a change of status of the loss of data indication. i.e. when
loss of data is detected, when loss of data indication is acknowledges by the operator or when
data is re-gained when loss of data is indicated.

11.4 Automatic Baud Rate Detection


If valid data is not received and a No Data indication is given, then the MD77HR will scan all
available Baud rates to look for valid data at an alternative baud rate. If valid data is discovered
which corresponding to the list of acceptable data sentences, then the new Baud rate will be
stored and used for future data reception. With this feature there is no requirement to pre-select
a Baud rate for data transmission.

11.5 Heading Type Selection


The type of Heading displayed dependings on the available data. True Heading is displayed if
available and Magnetic Heading will be displayed if data is available for Magnetic but not available
for True.

11.6 Test Function


A Test Function is provided to give confirmation of the correct operation of the MD77HR electro-
mechanical arrangement and illumination.

To activate the Test Function, press and hold both buttons for 3 seconds until the Test
Function starts. During the test function, the dial will rotate to re-align to 000° and the illumination
and indicator LEDs will flash. An audible beep will be given when the test function is completed
and normal operation will resume and the dial will return to displaying the received heading.
The length of time taken by the Test Function will depend on the present heading. Any
acknowledged Loss of Data indication will be re-activated by the test function.

18
MD77HR
12 MAINTENANCE AND FAULT-FINDING
12.1 Maintenance
No scheduled maintenance is required. It is recommended to gently wipe away any accumulated
dust periodically.
Note: The MD77HR is a sealed unit and has no user-serviceable parts inside. Breaking the
factory seal will invalidate the warranty.

12.2 Fault-Finding
12.2.1 MD77HR does not operate
It is probable that there is a loss of power. Check the 24 V dc power supply to the MD77HR.

12.2.2 MD77HR aligns to 000° but does not follow the source heading
The NMEA 0183 digital signal to the repeater is either not present or the data sentence being sent
is not of the correct structure. Check the source Compass or the source of the heading data for
the presence of a valid heading data sentence.

12.2.3 Display illumination not functioning


If remotly controlled, an incorrect control signal may be being recieved, check wiring and signals.
The internal LED illumination devices may be damaged or there may be damage to the PCB or
front panel membrane. Return the unit to Marine Data for servicing. It should be noted that the
display illumination may not be noticable under bright ambient light conditions.

12.2.4 Dial oscillating +/- 35 degrees, Alert Indication on or True and Mag indication
both on
Check NMEA data connection and data validity.

19
MD77HR
12.3 Technical Support
If further technical support is required then please contact Marine Data Technical Support:
By email: support@marine-data.co.uk
Through our website: www.marine-data.co.uk
All technical support enquiries must include the following basic equipment information:

About your MARINE DATA Equipment:

1 MARINE DATA Equipment Model number (e.g. MD77HR)


2 MARINE DATA Equipment serial number
3 MARINE DATA Equipment batch code number
4 Details of firmware version (if available)

12.4 Reporting a Fault


If you suspect that your equipment has a fault, please be sure to include as much information
about the fault as possible. The following information checklist shows the additional information
which we will require to process a fault enquiry:

About the suspect fault:

1 Describe the signs that suggest there is a fault condition


Describe when and how often the fault occurred. Was this coincidental with the operation of
2
other equipment or procedures?
3 Describe the indications and the alarm status when the fault occurs
4 What was the power supply voltage when the fault occurred?
5 Describe the environmental conditions when the fault occurred
Provide details of the equipment supplying the data: Give the manufacturer, the equipment
6 model, serial no., software / firmware version numbers, NMEA sentence(s) transmitted, Baud
rate and message rate
Provide details of any other equipment or devices connected to the same data or power source
7
and whether they are also affected in any way
Provide specific wiring details: Which functions are used, which wiring connections are made
8
with what equipment and details of the termination of any unused cable cores

20
MD77HR
13 SPECIFICATIONS

13.1 Physical
Weight: 1.25 kg (with bulkhead mounting bracket)
Dimensions: (Bulkhead mounted): H 166 mm; W 200 mm; D 81 mm
Fascia Dimensions: 144 x 144 x 6 mm
Mounting: Panel-mounted or optional bulkhead mounting bracket
1x 15-way D-type connector; M4 Earth stud
Connections:
(supplied with data cable)
Finish: Jet Black (RAL9005) Fine-texture Powder Coat

13.2 Electrical
Power supply: 24 V dc nominal; 4 W max; (0.12 amps @ 24 V); 18-32 V dc
Data input: Digital RS422
NMEA 0183 (IEC 61162-1) Compliant;
Data protocol:
4800 / 9600 / 19200 / 38400 Baud, auto-selecting
Accepted in order of priority: THS, HDT (true),
Data sentences: HDG (magnetic heading with deviation and variation)
HDM (magnetic uncorrected)
Data outputs: Dial display; LED Indicators
Remote Dimming Control
0-24 V dc (with respect to supply negative)
Input:

13.3 Operational
Performance: ±0.5° accuracy
Follow-up rate: >20° per second
Rotating Compass card style display with graduations at 1°, 5° and
Display:
10°; 118 mm diameter
Nominal Viewing Distance: 1m
Dial resolution: Marked to 1° of angular displacement
Indication of loss of valid data: Dial oscillates ±35° about the last known good heading
MTBF: >30,000 hours

21
MD77HR
13.4 Environmental
IEC 60945 Equipment Category: Protected Area
Operating temperature range: -15°C to +55°C
Storage temperature range: -25°C to +70°C
Standard: 85cm
Compass Safe Distance:
Steering: 45cm
BS EN 60945:2002 Inc. corrigendum April 2008 (BSI, 2008)
BS EN 61162-1:2016 (BSI, 2016)
BS EN 62288:2014 (BSI, 2016)
BS ISO 8728:2014 (BSI, 2014)
BS ISO 16328:2014 (BSI, 2014)
Compliancy:
IMO Res. A.424(XI) (IMO, 1979)
IMO Res. A.821(19) (IMO, 1995)
IMO Res. MSC.36(63) (IMO, 1994)
IMO Res. MSC.97(73) (IMO, 2000)
IMO Res. MSC191(79) (IMO, 2004)
RoHS: Compliant

Type Approval:

13.5 Additional Information


Illumination colour and relative brightness levels are factory adjustable (subject to MOQ)
Supplied with 2.5 m of data cable terminated with a 15-pin D-sub type connector
If spare parts are required, then please contact either your supplier or Marine Data.
Marine Data reserves the right to makes changes to its products and specifications without notice.

22
MD77HR
14 SPARE PARTS AND ACCESSORIES
MD Part No. Description: Item:

MD77TB
Bulkhead Mounting
F077100
Trunnion Bracket
(Option)

SS20001 Data Cable Assembly, 2.5 m

MD01/PMD
SS37120 Panel Mount Remote Dimmer
Control Assembly

MD96JCB
F096001 16-way or 32-way
Weatherproof Junction Box

MD96JB8
F096020
Junction Box

MD94DDU
Data Distribution Unit
F094053
Advanced NMEA 0183 Data and Power
Distribution

23
MD77HR
15 GROUNDING AND SHIELDING
This repeater is designed to be grounded via an M4 earth stud provided on the rear panel. This
earth stud provides the electrical contact for protective earth bonding.
The power/data connector has a conductive outer casing which, when mated, connects to the
unit enclosure. A screened cable may be used; in this case the screen should only be connected
at the connector end to prevent earth loops.

16 SAFETY AND SECURITY


Please observe the following procedures to ensure safety of personnel installing and operating
the equipment:

• Ensure all power to the unit is disconnected and locked-out during installation,
maintenance and removal procedures
• Ensure power is disconnected and locked-out in the event of mechanical damage to the
unit, rendering internal parts accessible to personnel
• Only the electrical power of the specified voltage should be connected to the unit
• In the event of damage to the window: Care should be taken to prevent injury from any
sharp edges that may be exposed
• The panel to which the unit is mounted should be designed to provide adequate
mechanical support. This minimises the possibility of damage or injury caused under
mechanical shock conditions
• Care should be taken to ensure the fixings used to mount the unit to the panel are
correctly fitted and retain their mechanical integrity over time

24
MD77HR
17 GLOSSARY OF TERMS
Term: Description:

Electro-Magnetically Compatibility - specifically measured against


MIL-SPEC-461
EMC
Electromagnetic Compass (fluxgate coil Compass)

Maritime navigation and radio communication equipment and systems. General


EN60945
requirements. Methods of testing and required test results.

MOQ Minimum Order Quantity

MTBF Mean Time Between Failure

Combined electrical and data specification for communication between marine


NMEA 0183
electronic devices as specified by National Marine Electronics Association.

PCB Printed Circuit Board

Paint colour specification. RAL is a European standard colourspace and derives


RAL9005 from Reichs-Ausschuß für Lieferbedingungen und Gütesicherung (from the German
Imperial Commission for Delivery Terms and Quality Assurance).

RS422 Bus protocol that connects various devices

Sentence Transmitting NMEA string, for example from a Gyro

TMC Transmitting Magnetic Compass

VOLTS dc Volts Direct Current

25
MD77HR
18 ABOUT MARINE DATA
Marine Data is a brand name and trademark of Marine Data Systems Limited, a British multi-
award-winning company established in 1978 and based on the Isle of Wight, England. Marine
Data leads the world in the development and manufacture of marine navigation and control
systems.
Marine Data has earned a worldwide reputation for excellence in the manufacture and supply of
the best and most adaptable marine navigation systems for commercial, military, work and
leisure craft. Our expert design and engineering team can always provide innovative solutions to
complex marine navigation system requirements.
Our equipment is proudly fitted in the military naval ships of NATO, the Gulf States, the Far East
and Australasia. We work together with defence agencies and prime contractors for seamless
product integration in new build and retrofit projects. In the cruise liner industry, Marine Data is
the choice again; you will find our equipment on the liners of the world’s leading operators -
including P&O™ and Disney®. In the fishing industry, Marine Data is there to help the world’s
fishing skippers harvest the sea safely under the most arduous of conditions.
Success is based on our tried and tested products and on designing tailored solutions for our
customers. Alongside our proven talent for providing innovative solutions, we place a great deal
of emphasis on quality - and on quality procedures. This is backed up by our own environmental
test department, where we test our products to the most vigorous of standards.
We provide complete support for all our customers, providing expert service for all our steering
and navigation technology, thus protecting your investment. Marine Data has a manufacturing
system approved to ISO 9001:2015 which ensures we meet our customers’ extremely high
standards - every time.
From ferries to fishing vessels and from tugs to tankers, Marine Data is there to show the way.
We are continuously improving our products and updated manuals are available from our website
and are free to download. Register your product online and receive all the benefits of a two-year
extended warranty.

www.marine-data.co.uk

26
MD77HR
NOTES

27
MARINE DATA SYSTEMS LIMITED
Vittlefields Technology Centre
Forest Road
NEWPORT
Isle of Wight
PO30 4LY
UNITED KINGDOM
tel: +44 (0)1983 822180
email: sales@marine-data.co.uk
web: www.marine-data.co.uk