Quality Assurance:

The company operates in accordance with the ISO9001:


2008 international quality management system. Mobile
products are guaranteed for 3 years, and fixed products are
guaranteed for 7 years (HID light source is guaranteed for
1 year). During the warranty period, any failures occur
during normal use of the product. Contact our local service
Shenzhen SEVA Lighting Co ., Ltd
center, our company is responsible for maintenance free of

Product Manual
charge; we will provide you with high quality and fast
service.

Shenzhen SEVA Lighting Co ., Ltd


Venue: 25th Floor, Huafeng International Business Building, Baoan Avenue, Mobile Lighting Tower

SW2960
Baoan District, Shenzhen Postcode: 518102
Phone: + 86-755-2965 7412 Fax: + 86-755-2736 7927
Http://www.szseva.com.cn E-mail: seva@szseva.com.cn
Please read the product description carefully before installation and use.
This manual contains important installation and safe operation instructions.
Thank you for purchasing Shangwei Lighting!
This manual contains instructions for using SW2960 lamps. 2. Applicable Places

All contents in this book are consistent with the latest products at the It is suitable for large-scale lighting on the scene of various large-scale rescue,
time of printing. emergency repair and construction. It is very suitable for single person to carry,
Be sure to read and understand the manual before use, otherwise unfold and raise.
incorrect operation will cause personal injury or death or damage to
the lamp. 3. Parts Identification
(The generator equipped with this product has the original manufacturer's
instruction manual. It is used together with this instruction manual. The
instructions for the generator part shall be based on the original manufacturer's LED Lamp Head
instruction manual. This instruction will not be repeated)

1. Security Matters Lifting Rod

1. Due to transportation safety considerations, only a small amount of


lubricating engine oil is added when the generator leaves the factory, no
new fuel is added, and no new equipment is added. Power Cord
2. Before using the lamp, make sure that the chassis is placed stably.
Otherwise, accidents may occur due to the wire being pulled down or the
windy lamp falling during work.
Digital Generator
3. Before lifting or retracting the lifting rod, make sure that the locking screws
of the lamp head and the lifting rod are locked to prevent the lamp head
from falling and causing injury.
4. Before starting the generator, make sure that the waterproof connectors Generator Case

on the upper and lower parts of the lifting rod are tightly screwed in place Storage Status
to prevent rainwater from entering the joint and causing leakage.
5. All plugs of the plugs are operated when the power is turned off to prevent Support Foot
electric shock caused by rainwater flowing onto the plugs when the plugs
are charged.
6. When the lamp is just extinguished, the temperature of the lamp housing
is very high, and the body cannot directly contact the lamp housing to
prevent high temperature burns.

Raised State

01.
4. Installation and commissioning 5. Start And Raise

① When using for the first time, first take the ② Fix the lifting rod to the ③ Unscrew the locking screw on ① Adjust the choke handle of the ②Turn the engine switch ③ Gently pull the starting handle
the top of the lifting rod, then
generator out of the packing box and place generator box with a Phillips generator to the "start" position. to the "ON" position. until you feel resistance, and then
it steadily, then open the two buttons on the screwdriver. take the two lamp heads out of
the generator box and place it on
quickly pull to start the engine.
generator box.
the top of the lifting rod, and then
tighten the locking screw on the top
of the lifting rod.

④ After the engine is started, return the ⑤ Connect the power transmission
choke handle to the "running" position. waterproof socket of the generator
⑤ According to the needs of the site
to the three-pin plug of the lamp.
④ Connect the waterproof head
⑥ Insert the special plug of the
work, two lamp heads can be
of the lead wire of the lifting rod generator in the accessory package
adjusted at any angle of 360 degrees
to the waterproof seat led by the horizontally and up and down to into the output socket of the generator
lamp head, and tighten the meet the requirements of different
irradiation angles and orientations. in the corresponding direction, and
waterproof sleeve of the joint by rotate it until it is firmly inserted.
The light coverage radius is 30 to 50
hand. meters.

⑥ First use one hand to open the buckle on ⑦After raising the lamp to a suitable height, pull the lifting
the lifting rod, and then use the other hand rod upward with one hand and tighten the buckle on the
Oil Tank Port Fuel Tank Port
to pull up the lifting rod. lifting rod with one hand.
⑦ Open the generator maintenance door to add
oil, unscrew the top fuel cap and inject 6. Use Of Lamps
gasoline. For specific requirements, please
refer to the original manufacturer's manual.
1. Two lamp holders can be adjusted at any angle of 360 degrees horizontally and up or
down according to the needs of on-site work, to meet the requirements of different
Warning: irradiation angles and orientations, and the light coverage radius is 30 to 50 meters.
The amount of refueling oil must be strictly in accordance with the original manufacturer's 2. It can be powered by a generator, and it can also be directly powered by a
instructions. Too little oil: it may not be pulled or easily self-extinguished, and it may even seriously
commercial power supply in a place where there is a commercial power supply.
damage the engine. Too much oil: it will increase the additional load of the engine.
3. With a waterproof power transmission socket, you can supply power to other
equipment after taking power from the socket.
02 03.
7. Stop And Store

⑤ Loosen the locking screws of the lamp head, ⑥ Tighten the locking screw on the top
and then remove the two lamp heads into the of the lifting rod.
generator box.
①After completing the work, turn the ② Unplug the power transmission waterproof
engine switch to the "OFF" position, socket of the generator and the three-pin plug
at this time the generator stops working, of the lamp.
and the two lights of the lamp head turn off.

⑦ Finally, it can be carried in a variety of ways, such as


hand-carrying, towing, shoulder and shoulder.

③ Support the lifting rod with one hand, ④ After the temperature of the lamp

open the buckle on the lifting rod with housing of the lamp cools to the point

the other hand, and the lamp head slowly that it is not hot, loosen the waterproof

descends. connectors of the two lamp caps.

04 05.
8. Maintenance 9. Transportation And Storage

1. The repair, maintenance and maintenance work of the lamps and 1. When the lamp is shipped from the factory, the generator and the lamp
lanterns must ensure that the power supply is completely disconnected. head are in the generator box, the lifting rod and the generator box are
After the lamps are extinguished, the temperature of the lamp case is in the carton, and they are fixed and protected. After receiving the
cooled to the point that it is not hot. goods, please check whether the outer box is damaged or not The
equipment is damaged. If there is such a situation, please contact our
2. Regularly check whether there are hidden safety hazards such as falling
local sales personnel in time.
off, aging or mouse bites. If so, replace the cables that meet the
requirements in time. 2. Random documents and accessories are packed in a transparent sealed
bag, please pay attention to storage and storage when unpacking.
3. Wipe the dust accumulated on the lamp housing and transparent parts
regularly with a damp cloth to prevent dust accumulation on the 3. When the lamp is not in use, it is best to cover it with waterproof and
transparent parts to affect the lighting effect (the power must be turned dustproof cloth during storage, otherwise the dust accumulation will
off and the lamp is cooled to operate). affect the normal use of the generator and the lifting rod.

4. Every time after use and storage, be sure to remove the dust and foreign
objects on the surface of the lifting rod, otherwise it will be brought into
the lifting rod, which will wear the lifting rod, causing the lifting rod to be
difficult to expand or contract or affecting the gas Dense.

5. The lifting rod is made of hard aluminum alloy material. Although it has
high strength, it should still be careful not to be injured or crushed by
heavy objects, otherwise it will affect the lifting and shrinking of the lifting
rod.

6. The average life span of the LED lamp is 50,000 hours. If the LED is
damaged, please contact our local service personnel.

7. For the maintenance and repair of the generator, please refer to the
requirements (important) of the original manufacturer's manual
attached.

06 07.
10. Common Troubleshooting 11. Main Technical Parameters

Fault phenomenon 1. The generator cannot start.


No Parameter Unit Value
Treatment method: Please refer to the relevant instructions of the generator's manual
1 Rated Voltage V 220VAC 50Hz
for troubleshooting.
Fault phenomenon 2. The generator has started, but the operation is unstable. Power W 2×48
Lamp Head
Solution: Please check whether the choke handle is set to the "running" position, or 2 LED Average Service Life h 50000
Assembly
there is too little oil, or the intelligent throttle switch is not turned off. 2×4000
Luminious Flux lm
Fault phenomenon 3. The generator has been running normally, but the lamp is not on.
Rated Output Voltage V 230VAC 50Hz
Solution: Please check whether the waterproof socket of the power supply, the lifting rod Generator Set
3 Continuous Working Time h ≥5.5
and the waterproof connector of the lamp head are in place, or the choke (IG770)
Rated Output Power /
handle is adjusted to the "operation" position. W/L 700/1.55
Fuel Tank Capacity

Use Status (Descending) mm 485×340×720


4 Dimension
Use Status (Raised) mm 485×340×2300

Storage Height m 0.72


5 Lifting Rod
Lifting Height m 2.3

6 Weight kg 23

7 Enclosure Rating IP65 (Lamp Base) / IP54 (Lamp Cabinet)

8 Anti-corrosion Rating WF2

08 09.