Radio 4499 B1B3

installation and operation


specifics in
Azercell network
| EPERKON Konstantin Permyakov | 2020-04-22 | Ericsson Internal | Page 1 of 4
Power connector
DC-I
(isolated „return/0V“ & ground)

RNT 447 32/02

high power connectors)


Power Connector
(can be replaced by 2,5mm² -10mm² Max 40A
Low Power

Most classic ERS radios,


short+medium cable lengths
Connector RNT 447 36/01 is
RNT 447 32/03 compatible with Radio 4499
Power Connector
10mm² - 16mm² Max 40A
RNT 447ERS
Most classic 36/01
radios
No adapters
Longer cable needed
lengths
Max 55A Connector RNT 447 32/02 is
RNT 447 38/02
(compatible to „ low power“

2,5mm² - 16mm²
Power Connector certified for 26A max and it is
6 mm² - 10mm² All type of ERS Radio & AAS
Max 55A not compatible with Radio 4499
High Power

AAS + new multiband radios


short+medium cable lengths
mechanically
radios)

RNT 447 38/03


Power Connector
10mm² - 16mm² Max 55A
AAS + new multiband radios
short+medium cable lengths
| EPERKON Konstantin Permyakov | 2020-04-22 | Ericsson Internal | Page 2 of 4
Recommended output power level of Radio 4499 in case
in Power 6302 power supply and 4T/4R operation.
●Load for 1 DC out of Power 6302 is 815W (max).
4T/4R LTE 2100
4T/4R LTE 1800 Total output power
2T/2R WCDMA 2100 level is 160W
2T/2R GSM 1800
operation

40W 40W 40W 40W


Tx/Rx Tx/Rx Tx/Rx Tx/Rx

Radio 4499

If power cable length is up to 15 meters, 2.5 mm² cable (TFL 901 34) can be used for above listed operation
In case of power cable length is longer than 15 meters (up to 20 meters) - 6 mm² cable should be used
| EPERKON Konstantin Permyakov | 2020-04-22 | Ericsson Internal | Page 3 of 4
Recommended output power level of Radio 4499 in case
in Power 6302 power supply and 2T/2R operation.
●Load for 1 DC out of Power 6302 is 815W (max).

2T/2R LTE 2100 2T/2R LTE 1800 Total output power


2T/2R WCDMA 2100 2T/2R GSM 1800 level is 220W
operation operation

55W 55W 55W 55W


Tx/Rx Tx/Rx Tx/Rx Tx/Rx

Radio 4499

If power cable length is up to 10 meters, 2.5 mm² cable (TFL 901 34) can be used for above listed operation
In case of power cable length is longer than 10 meters (up to 20 meters) - 6 mm² cable should be used
| EPERKON Konstantin Permyakov | 2020-04-22 | Ericsson Internal | Page 4 of 4