Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

MasterLife® WP 1200

Crystalline waterproofing admixture for concrete & mortars

DESCRIPTION  Becomes an integral part of the concrete


MasterLife WP 1200 crystalline waterproofing  Reduces penetration of water and other liquids
liquid admixture is an integral crystalline capillary  Can seal hairline cracks up to 0.4 mm
waterproofing admixture for concrete. It is  Resists positive and negative side hydrostatic
designed for use in above- and below-grade pressure
applications.  Protects against sewage and industrial wastes
 Less expensive than traditional methods
MasterLife WP 1200 consists of various active,  Added to the concrete at time of batching and
proprietary chemicals. These active chemicals therefore, is not subject to climatic restraints
react with the moisture in fresh concrete with the
by-products of cement hydration to cause a PACKAGING
reaction, which generates an insoluble crystalline MasterLife WP 1200 is available in 5 kg, 25 kg
deposit throughout the pores and capillary tracts of pack and 1,000 kg.
the concrete. Thus, the concrete with
MasterLife WP 1200 reduces water permeability.
This product also has a self-healing property under PERFORMANCE CHARACTERICS
presence of moisture and can heal cracks below Setting time:
0.4 mm. MasterLife WP 1200 admixture has little to no
effect on concrete setting time within the
TYPICAL APPLICATIONS recommended dosage range. However, it is
recommended to test this in case any additives or
MasterLife WP 1200 should be used in all blended cementitious combinations are used in
structural concrete that is constantly or concrete.
intermittently in contact with water such as sea
walls, tunnels, basements, structural and pre- cast Permeability:
concrete. MasterLife WP 1200 can also be used MasterLife WP 1200 capillary waterproofing
as crystalline waterproofing admixture for cement admixture is a liquid-based crystalline material that
mortars and plasters. To waterproof structures reacts in concrete to form insoluble crystalline
such as: hydration products in the capillary pores/capillary
tracts of the concrete. These crystalline hydration
 Building basement and foundations products are deposited and fill the pores and
 Sewage and water treatment plants hairline cracks, effectively reduce the permeability
 Dams, canals, Tunnels, Harbours of concrete, its capillary absorption and
 Tunnel and subway systems penetration of water and other liquids into the
 Water reservoirs concrete.
 Concrete pipes
 Parking structures
 Pre-cast, cast-in-place and shotcrete
applications
 Swimming pools
 Retaining walls & sea defense walls

ADVANTAGES
 Crystalline liquid material
 Integral addition
 Reduces concrete permeability
 Allows concrete to breathe
 Non toxic
MasterLife® WP 1200

Typical Data for MasterLife WP 1200 admixture @ 1% by mass of cement.

OPC Fly Ash w/b water 20mm 10mm sand MasterGlenium MasterLife WP 1200

370 120 0.34 166.5 530 530 708 0.6% 1%

Specification Test Results


Water Permeability coefficient - 5x10-13 m/s 1.3x10-13
(DIN1048 Part 5)
Water Penetration depth - Below 15mm 6.67mm
(DIN1048 Part 5)
Concrete water proofing admixture shall of the SEM Report shows Crystalline growth and lower void in
crystalline growth type concrete relative to untreated concrete mixture.
Water Penetration Reduction up to 30 to 35% relative to untreated concrete
mixture
Workability MasterLife WP 1200 has little or no effect on workability
Setting time of concrete relative to untreated concrete mixture
Aspect Clear to yellow liquid
Bulk density 1.13-0.02 kg/L
Chloride content “chloride free” to EN 934

APPLICATION GUIDELINES MasterLife WP 1200 admixture is batched at the


As a guide, a dosage rate of 1 - 2.5%. For addition concrete production plant in a manner similar to
to ready mix concrete, a typical dosage of 6-7 kg that for liquid based Admixtures or similar liquids.
per cubic meter of concrete is best recommended. It may be batched in either a central or truck mixer.
Follow the procedures outlined in ASTM C94
For addition information on MasterLife WP 1200 /C94M, Standard Specification for Ready-Mixed
or on its use in developing concrete mixes with Concrete, for general batching and mixing
special performance characteristics, please instructions for concrete if adding to a truck mixer.
contact your local Master Builders Solutions Provide at least 5 minutes of mixing after the
representative. addition of MasterLife WP 1200 admixture to
ensure thorough and uniform distribution of the
Points to remember when producing admixture in the concrete mixture.
waterproof concrete:
 Ensure water / cement ratio is less than 0.5 MIXING
 Addition of good superplasticiser from the MasterLife WP 1200 admixture can be used with
MasterRheobuild or MasterGlenium range is portland cements approved under ASTM and EN
advised to achieve minimum water/cement specifications. It is compatible with most concrete
ratio. admixtures, including all Master Builders Solutions
 Place concrete quickly and compact it well. admixtures. MasterLife WP 1200 admixture is
 Ensure complete curing with a MasterKure recommended for use with high-range water
curing compound. reducing admixtures, such as the MasterGlenium
series, for maximum workability while maintaining
a low water-to-cementitious materials ratio.

Note: MasterLife WP 1200 is also compatible with


slag and pozzolans such as fly ash, GGBS and
silica fume.
MasterLife® WP 1200
CORROSIVITY - NON-CHLORIDE, NON HEALTH AND SAFETY
CORROSIVE For health, safety and environmental
MasterLife WP 1200 will neither initiate nor Recommendations, please consult and follow all
promote corrosion of reinforcing steel embedded instructions on the Material Safety Data Sheet.
in concrete, prestressed concrete or concrete
placed on galvanized steel floor and roof QUALITY AND CARE
systems. Neither calcium chloride nor any calcium All products originating from Master Builders
chloride-based ingredients are used in the Solutions Dubai, UAE facility are manufactured
manufacture of MasterLife WP 1200. In all under a management system independently
concrete application, MasterLife WP 1200 will certified to conform to the requirements of the
conform to the most stringent or minimum chloride quality, environmental and occupational health &
ion limits currently suggested by construction safety standards ISO 9001 and ISO 14001.
industry standards and practices.
* Properties listed are based on laboratory controlled tests.

WORKABILITY ® = Registered trademark of the MBCC Group in many countries.


MasterLife WP 1200 has little or no effect on
workability of concrete. Prior site trials are advised
to assess the effect, and any increase or decrease
in the workability can be adjusted by adjusting the
admixture dosage or amount of water in use.
It is strongly recommended that concrete should
be properly cured particularly in hot, windy and dry
climates.

STORAGE AND SHELF-LIFE


MasterLife WP 1200 must be stored where
temperatures do not drop below +5°C.
Shelf life is 6 months when stored as above.

Failure to comply with the recommended storage


conditions may result in premature deterioration of
the product or packaging. For specific storage
advice consult your local Master Builders Solutions
representative.

MBS_CC-UAE/Life_WP1200_11_20/v1/02_22
The technical information and application advice given in this Master Builders Solutions publication are based on
STATEMENT OF the present state of our best scientific and practical knowledge. As the information herein is of a general nature, no
RESPONSIBILITY assumption can be made as to a product's suitability for a particular use or application and no warranty as to its
accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user
is responsible for checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by Master Builders
NOTE Solutions either orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since
they, and not Master Builders Solutions, are responsible for carrying out procedures appropriate to a specific
application.

Master Builders Solutions


Construction Chemicals LLC
P.O. Box 37127, Dubai, UAE
Tel: +971 4 8090800
www.master-builders-solutions.com/en-ae

Disclaimer: the TUV mark relates to


certified management system and not to the
product mentioned on this datasheet