COLLATERAL LOAD
Collateral Load on Rafter = 0.00 Kg/m² Other Collateral Load = 0.00 Kg/m²
= 0.00 KN/m = 0.00 KN/m
PRESURE COEFFICIENTS:~
Encloser condition of the building = Enclosed
Internal pressure coeff.(Cpi) = 0.20
h/w = 0.19
= h/w<=1/2
l/w = 1.12
= 1<l/w<=3/2
External pressure coeff.(Cpe) : Table 4 Table 5
Wind Angle
Coeff. For Wall Coeff. For Roof
(ө)
Left Right Left Right
0 degree 0.70 -0.25 -0.9350 -0.40
90 degree -0.50 -0.50 -0.80 -0.80
Wind Across the Ridge (With -Ve Cpi) Wind Across the Ridge (With +Ve Cpi) KN/m
-0.74 -5.65 KN/m -0.20 -1.54KN/m -1.14 -8.717 KN/m -0.60 -4.61
KN/m KN/m
-5.38 -5.38
-0.70 -0.70
KN/m KN/m
-2.30 0.00
-0.30 -0.30
STEEL SECTION
DIMENSION WT(KG)
1 COLUMN W-800 TO 560x18 2F-400x20
71305.6
2 RAFTER W-800 TO 560x18 2F-400x20
3 Purlin PURLIN ST 180CS50X5CHANNELS WITH LIPS-RECTANGULAR 26364.2
4 Bracing RSH 300X150X8THK 31529.3
5 Connection Plate 13229
6 Base Plate 750x750x25 3090.938