Professional Documents
Culture Documents
Sterilization & Aeration in As Little As 3.5 Hours
Sterilization & Aeration in As Little As 3.5 Hours
ONLY
17.6g
Sterilization & Aeration in as little as 3.5 hours OF GAS
Andersen’s exclusive EO-Flexible Chamber Technology (EO-FCT)
Turn-around time for delicate medical items has never been this fast. Andersen’s FDA-cleared, and 17.6g gas cartridge (90% less gas than any other system)
temperature-controlled EOGas 4 features four cycles with active aeration in the same cabinet - the combine to provide your facility with the proven reliability of
fastest being just 3.5 hours, including aeration. This is also the only sterilizer available that can deliver EO in a modern, highly efficient package.
terminal sterility at 86°F, in a 12-hour cycle. All in a convenient tabletop format.
Simplified Controls
3.5-Hour Sterilization
Easy to use two-button Innovation at work ETHYLENE OXIDE
FLEXIBLE CHAMBER TECHNOLOGY
Achieves FDA-required 10-6 S T E R I L I Z A T I O N
interface and digital display.
sterility assurance level for Taking Excellence to the Next Level
terminal sterilization of Sterilization status and cabinet
STERILIZATION GAS
medical devices. temperature shown throughout The premier sterilization solution for busy practices that BAG CARTRIDGE PURGE PROBE
the cycle. use the same high dollar instrument multipule times a DOSIMETER LOAD
BIOLOGICAL
PCD
What Load and Material Types are Cleared by the FDA for the EOGas 4?
Make Your System Replaceable Abator
Zero Emissions Cartridge Device Type Maximum Load Device Examples Required Aeration
Andersen’s optional 200 cycle capacity. Spent
abators are a simple, cartridges are non-hazardous One (1) ≥ 2.0 mm internal diameter
and may be discarded in most Gastrovideoscopes,
cartridge-based system ≤1100 mm length; gastrointestinal videoscopes
that employ a dry landfills or returned to Single-lumen No additional devices 12 hours at 50°C; Follow
catalyst resin. The Andersen for disposal. Endoscope(s) manufacturer’s instructions
Four (4) ≥ 1.2 mm internal diameter Bronchoscopes, bronchovideoscopes,
resin converts ethylene EASY TO MAINTAIN ≤ 700 mm length; cystoscopes, ureteroscopes,
oxide to biodegradable No additional devices choledocoscopes
organic compounds.
Delicate sharps and surgical Metal instruments do not absorb EO. Follow pouch
Replacement cartridges remove
Metal 24 lbs (11kg) instruments, including those or wrap manufacturer’s instructions (Example:
more than 99% of the EO in the exhaust with hinges & mated surfaces Sterisheet wraps require ≥ 6 hours at 50°C)
stream, resulting in a fraction of a gram of
total EO emissions over the course of a
Plastic 7 lbs (3.2kg) Reusable power cords, trocars Follow manufacturer’s instructions: 24 hours at 50 °C
multi-hour cycle. This tiny amount of EO is
vented to the outside where it disperses
Fabric 6.1 lbs (2.8kg) Reusable cloth gowns, towels Follow manufacturer’s instructions: 12 hours at 50 °C
rapidly, quickly becoming undetectable.
EOGas 4 FDA 510(k) clearance: http://bit.ly/EOGas4FDA510k
NEXT GENERATION
DIMENSIONS AND GAS STERILIZATION
SPECIFICATIONS
From Zero
22" 28.25"
6"
Wall
to Sterile
28"
23.25"
19"
28"
clearance
in 3.5*
EOGas 4 25.25" L x 18"W x 14" H 29.5" L x 22"W x 28" H 161 lbs (73 kg)
multiple times a day
Power Supply: 120v (240v available)
“The latest generation of heated gas sterilization units have been a Dr. Joseph P. Hunstad
game-changer. Instead of a 24-hour cycle, now we have a few hours Plastic Surgeon
cycle and it's changed our whole environment. I recommend these H/K/B Cosmetic Surgery
Huntersville, NC
to colleagues all over the world.”
A leader in 100% ethylene oxide sterilization for more than 60 years, Andersen’s machines are critical to the daily CLEARED
infection control process in thousands of clinics, veterinary and human hospitals, and industries across 75 countries.
Family owned and operated, always manufactured in the United States, Andersen is dedicated to protecting your
patients and our environment.
EO sterilization and aeration
sterility.com REGISTERED in as little as 3.5 hours.
Join Us: Follow, Like, Share #3004634710
PN4038_091917
Health Science Park • 3202 Caroline Drive Distributed in Europe by: H.W. Andersen SARL
Haw River, NC 27258-9564 USA Distributed in UK, Australia, Africa & Middle East by:
800.523.1276 H.W. Andersen Products, Ltd.
IN THE USA anderseneurope.com