APPENDIX A: Calculation table of IBS Score for Genesis One Condominium


Apendiks A: Jadual pengiraan Skor IBS untuk pangsapuri Genesis One

Area (m2) /
IBS
No. Elements Length Coverage IBS Score
Factor
(m)
Part 1: Structural Systems
(i) 79.7 x2)+ 0.6 20740/21569.6 0.96 X 0.6 X 50=
71.1 x2)+ =0.96 28.80
In-situ column with 76.4 x2)+
timber formwork 94.2+
105.3+
• Precast two-way slab
89.3 +
• Precast beam 86.4) x 25=
1 20740m2
(ii) 1.0 829.6/21569.6= 0.038X 1.0 X 50
• Precast lightweight 0.038 =
cast-iron roof truss 1.9

1.0 30.67
Total Part 1
Part 2: Wall Systems
(i) 14500m 0.5 14500/ 0.4X0.5X20=
36000= 0.4 4.0
Internal wall Type A1:
autoclaved aerated
concrete (AAC) block
system – total length of
580m (each floor)

580X 25 = 14500

(ii) 8750m 0.7 8750/ 0.2X0.7X20=


Internal wall Type A2: 36000= 3.4
Gypsum drywall system 0.24
2 – total length of 350m
(each floor)

350 X 25= 8750

(iii) External wall: 12750m 1.0 12750/36000 0.35X1.0X20=


Precast structural = 7.08
insulated panel (SIP) 0.35
system – total length of TOTAL =
36000m
510m (each floor)
510 X 25 = 12750
14.514
Total Part 2

Part 3: Other simplified construction solutions


(i) 3

Vertical repetition of
structure = 85%

(ii) 4

Usage of precast
staircases = 90%

(iii) 3

Repetition of floor-to-
floor height = 75%

(iv) 2

3 Submission using Level


1 BIM Model

(v) 2

55% of door sizes


follow MS1064 Part 4

(vi) 4

75% of window sizes


follow MS1064 Part 5

(vii) 6

Usage of Modular
gridlines = 80%

Total Part 3 24

IBS SCORE = Part 1 + Part 2 30.67+14.514+24


+ Part 3 =69.184%