Energy-Saving Ejector: Vacuum Unit
Energy-Saving Ejector: Vacuum Unit
Series ZK2
Vacuum Ejector/Vacuum Pump System
90
Digital pressure switch for vacuum
with energy saving function ZR
cuts supply air when the pressure
reached the desired vacuum.
ZA
Air consumption % reduced
ZX
ZM
More efficient ejector ZMA
Two-stage ejector
First ejector Second ejector
Q1 + Q2 = Suction flow
28
D-sub connector Flat ribbon cable
Volume 88 cm 3
% reduced
Existing product
ZK2 Individual
wiring
905 A
Energy Part number
Ejector with energy saving function
ZK2A12K5KW-08
Existing product
ZM131AM-K5LZ-E15
Symbol and formula
Calculation conditions
saving
Air consumption 58 L/min (ANR) 85 L/min (ANR) A
Suction flow 61 L/min (ANR) 44 L/min (ANR) For reference (ZK2 > ZM)
Supply pressure 0.35 MPa B
Operation model
Operation frequency 450 cycle/h E
Operating time (hours) 10 h/day F
Power consumption cost per year
Operating period (days) 250 days/year G
product: 75,938 yen/year for Air consumption (for total operation) 6,525 m3/year 95,625 m3/year K = J x 60 x I
18,750 of total operation hours.
Power consumption ∗2 0.19 kW 0.27 kW L (Theoretical value obtained from A and B)
Ejector with energy saving func-
Power consumption cost per year 5,344 yen/year 75,938 yen/year M=CxIxL
tion: 5,344 yen/year for 1,875 of
∗1 Adsorption time is the time in a cycle when the ejector supply valve is ON and vacuum is generated. The supply valve of the ejector
total operation hours. Cost re- with energy saving function is OFF after confirming the adsorption. The supply valve of the existing ejectors remains ON.
duction by 90% (70,594 yen/year). ∗2 Power consumption of the compressor is obtained by theoretical formula based on flow consumption and supply pressure.
Energy-saving ejector
Digital pressure switch with energy saving function
reduces air consumption by 90% ∗ or more.
When the vacuum pressure reaches the set pressure, the pressure Digital pressure switch
for vacuum with energy
switch turns off the supply valve. When the vacuum pressure
saving function
decreases, the pressure switch turns the supply valve on and
automatically controls it to maintain the vacuum pressure.
(Air consumption of the ejector)
during adsorption.
Ejector with energy
saving switch
Air supply is stopped
during adsorption.
Workpiece Workpiece
Existing Ejector with energy
Digital pressure switch for vacuum ejector saving switch
with energy saving function P2
A 906
All in One Piping Wiring Installation time reduced!!
Vacuum
Pressure sensor
Suction filter Silencer exhaust
Silencer cover
up to 10
Transparent filter case Filter element and the sound If there is dirt inside the units.
allows visual check of absorbing material can be installed/ case, it is possible to remove 10 units
the contamination. removed without using screws. the case and clean it.
Option
Single unit Single unit Manifold
Mounting
Mounting bracket
Stopper
907 A
Vacuum Unit Variations
Vacuum Ejector Vacuum Pump System
Manifold stations Wiring type Exhaust type Air pressure supply (PV) port Vacuum pressure (PV) port
• D-sub connector ø8, ø5/16" ø8, ø5/16"
1 to 10 stations • Silencer common exhaust
• Flat ribbon cable • Common supply
• Individual port exhaust • Common supply
• Individual wiring • Individual supply (Option)
Individual
wiring Common pilot pressure
supply (PS) port
Manifold Variations
D-sub connector
Common air pressure
supply (PV) port Individual port
Silencer common exhaust
exhaust
Flat ribbon
cable connector
Individual air pressure
supply (PV) port (Option) Common vacuum pressure
supply (PV) port
A 908
Series ZK2 Vacuum Unit
ZK2
ZQ
ZR
INDEX ZA
ZX
ZM
How to Order
ZMA
How to Order Single Unit ................................................................................ 910
How to Order Manifold .................................................................................... 912 ZL
ZH
Specifications/Flow-rate Characteristics
ZU
Specifications, Weight ..................................................................................... 914 ZYY
Exhaust Characteristics, Flow-rate Characteristics .................................... 915 ZYX
Port Layout
Standard Products ........................................................................................... 919
Option -D ........................................................................................................... 921
Option -L ........................................................................................................... 923
Construction
Construction ...................................................................................................... 924
How to Order Replacement Parts ................................................................. 925
909 A
Vacuum Unit
q System/Body Type w Combination of Supply Valve and Release Valve Note 2) Supply valve
Release valve
Symbol System Body type Exhaust type Symbol Supply valve Release valve
Note 1)
K N.C. N.C.
P Single unit —
Note 3)
Vacuum pump J N.C. None
system
Note 4)
Q For manifold — Self-holding release
R valve linked
N.C.
Note 1) PS port size of pump system: mm: ø4 Note 2) Only non-locking type is available for the manual override for “K, J, R”.
inch: ø5/32" Note 3) When “J” is selected for vacuum pump system, install a release valve or vacuum
breaker.
Note 4) Self-holding type maintains vacuum by instantaneous energization (20 ms or more).
Stopping the vacuum turns on the release valve. (signal to stop vacuum not needed)
Note 6) Unit selection function is not available in Japan due to new measurement law.
Note 7) Fixed unit: kPa
B 910
Vacuum Pump System
t Supply Valve/Release Valve/Digital Pressure Switch for Vacuum Connector Specifications y Vacuum (V) Port Note 14)
wFor supply valve/release valve Note 8) rLead wire with connector Symbol Type Port size
Symbol for pressure switch/ ø6
Connector type Lead wire with connector sensor Note 11) 06 One-touch fitting
Metric
C Note 12) 08
size ø8 ZK2
One-touch fitting
Common wiring
(Plug-in) 07
ø1/4" ZQ
(For manifold) Inch One-touch fitting
V
C1 Note 13)
09
size ø5/16" ZR
One-touch fitting
N L2/L3 08
00
P/T Note 12) C/L/L1 07
K/R A/B/C/D/E/F/H/J C/C1/L/L1/L2/L3 09 C/J/K/P Note 17)
N C1/L2/L3
Q
P/T Note 12) C/L/L1
J A/B/C/D/E/F/H/J C/C1/L/L1/L2/L3 C
N C1/L2/L3
Note 19) When “J” is selected for w Combination of Supply Valve and Release Valve , “J or K” cannot be selected for u Optional Specifications.
For options not in the table, please contact SMC.
Refer to page 940 when mounting single unit to DIN rail.
911 C
Vacuum Unit
Ejector System
Refer to page 912
How to Order Single Unit for How to Order Manifold.
ZK2
ZM
q System/Body Type e Combination of Supply Valve and Release Valve Note 3) Supply valve
Release valve ZMA
Symbol System Body type Exhaust type Symbol Supply valve Release valve
Note 5) ZL
Silencer K N.C. N.C.
A exhaust ZH
J N.C. None
Single unit ZU
Port Note 4) ZYY
B exhaust Self-holding release
ZYX
R valve linked
N.C.
Ejector
system
Common N None None
C Silencer
exhaust Note 3) Only non-locking type is available for the manual override for “K, J, R”.
Note 4) Self-holding type maintains vacuum by instantaneous energization (20 ms or more).
For manifold Stopping the vacuum turns on the release valve. (signal to stop vacuum not needed)
Note 1) Note 5) When the digital pressure switch for vacuum with energy saving function is selected,
Individual select “K” for t Pressure Sensor/Digital Pressure Switch for Vacuum Specifications.
F port
exhaust
Note 7) Unit selection function is not available in Japan due to new measurement law.
Note 8) Fixed unit: kPa
Note 9) When “K, Q, R or S” is selected, select “K” for e Combination of Supply
Valve and Release Valve. Select “W” or “L3” for y.
A 911-1
Ejector System
y Supply Valve/Release Valve/Digital Pressure Switch for Vacuum Connector Specifications u Vacuum (V) Port Note 16)
eFor supply valve/release valve Note 10) tLead wire with connector Symbol Type Port size
Symbol for pressure switch/ ø6
Connector type Lead wire with connector sensor Note 13) 06 One-touch fitting
Metric
C 08
size ø8 ZK2
Note 14) One-touch fitting
Common wiring
(Plug-in) 07
ø1/4" ZQ
(For manifold) Inch One-touch fitting
V
C1 Note 15)
09
size ø5/16" ZR
One-touch fitting
L
Note 16) Supply port (PV) size of single unit: ZA
Note 11) Note 14) ø6 (mm), ø1/4" (inch)
L2 L-type plug
to page 925.)
Note 13) Standard lead wire length for pressure sensor is 3 m. Stan-
ZMA
Note 11) Note 15)
connector dard lead wire length with connector for switch for vacuum
and the lead wire length for switch with energy saving ZL
function is 2 m.
L3 Note 12) Note 15) Note 14) Select “C, L, L1, Y” when the pressure sensor (P, T) is
selected for t Pressure Sensor/Digital Pressure Switch ZH
for Vacuum Specifications.
W With lead wire for switch with Since only grommet type is available for the pressure ZU
energy saving function sensor, sensor without lead wire cannot be selected.
Note 15) Select when no pressure switch for vacuum, pressure ZYY
sensor, or pressure switch for vacuum with connector ZYX
Y Non-valve (without supply/ Note 14) without lead wire is used.
release valve) When “N” is
Y1 selected for e
i Optional Specifications Note 17, 24)
When “N” is selected for both e (Combination of Supply Valve and Release Valve) Symbol Type Symbol Type
N and t (Pressure Sensor/Pressure Switch for Vacuum Specifications)
(without supply/release valve, without switch, pressure sensor)
Nil Without option Manifold individual
L supply specification Note 19)
With one bracket for mounting a single unit
B
(Mounting screw is attached.) Manifold common release
Single Unit and Options Note 25) P pressure supply specification Note 21)
With individual release pressure supply
q w e r t y u i D (PD) port type Note 18)
With exhaust interference
System/ Nominal Combination of supply Rated Pressure sensor/digital pressure Supply valve/release valve/digital pressure Vacuum (V) Optional W prevention valve Note 20, 22, 23)
Body type nozzle size valve and release valve voltage switch for vacuum specifications switch for vacuum connector specifications port specifications Vacuum break flow adjustment needle
J Round lock nut type
P/T Note 14) L/L1
A/B/C/D/E/F/H/J L/L1/L2/L3 B/D/J/K/W Vacuum break flow adjustment needle
K Note 20) K
N L2/L3 Screwdriver operation type
K/Q/R/S L3/W B/D/J/K Note 23)
5·6
· · ·
P/T Note 14) C/L/L1 Note 22) When “J” is selected for e Combination of
R A/B/C/D/E/F/H/J C/C1/L/L1/L2/L3 J/K/L/P/W Supply Valve and Release Valve and “W”
Note 19, 20, 21) (exhaust interference prevention valve type) is
C/F N C1/L2/L3
selected for i Optional Specifications, install
P/T Note 14) C/L/L1 a release valve or vacuum breaker.
J A/B/C/D/E/F/H/J C/C1/L/L1/L2/L3 L/W
Note 19, 20, 22) Note 23) When “K”, “Q”, “R”, or “S” is selected for t Pressure
N C1/L2/L3 Sensor/Digital Pressure Switch for Vacuum Specifications,
P/T Note 14) Y the exhaust interference prevention valve is provided. So, it
N 0 A/B/C/D/E/F/H/J Y/Y1 L/W is not necessary to select “W”.
Note 19, 20, 22)
N N Note 24) Refer to page 935 for Function/Application
Note 25) When “J” is selected for e Combination of Supply Valve and Release Valve , “J or K”
cannot be selected for i Optional Specifications/Functions/Applications.
For options not in the table, please contact SMC.
Refer to page 940 when mounting single unit to DIN rail.
911-2 A
Series ZK2
ZZK2 04 A 1 L
q w e r t y
Remains blank
when option is not
selected. Common PS port
q Stations Note 1)
w System (Port combination) Note 2)
Individual wiring
Ejector
system
D-sub connector
Without silencer F
(25 pins) Note 9)
2 (Individual exhaust port) Note 6) Individual D-sub
exhaust port connector
912
Vacuum Unit Series ZK2
Example
2
ZK2C10R5NL2-08 PN
ZK2C10R5NC1-08 01 Nil
ZZK2 ·
…
L·F·P·N
A
A
1
10
·
·2
ZZK204-A1P-B
AN
de
si
U
ns
tio
ta
S
3
2
1
de
si
D
• When the manifold is viewed from V port, the first station starts from
the left (D side).
• After the manifold part number, specify the installed single unit from
the first station.
• Common silencer exhaust and individual port exhaust cannot be
mixed in the ejector system manifold.
• DIN rail should be ordered separately. (Page 926)
913 B
Series ZK2
Specifications
General Specifications Valve Common Specifications
Operating temperature range –5 to 50°C (with no condensation) Valve model Note 3) ZK2-VAR ZK2-VAK ZK2-VAJ
Fluid Air, Inert gas Type of Self-holding supply valve Supply valve N.C. Supply valve N.C.
Without pressure sensor/switch for vacuum actuation Note 4) Release valve N.C. (Linked) Release valve N.C. Without release valve
Vibration 30 m/s2
With pressure sensor Valve configuration Pilot operated dual 2 port Pilot operated 2 port
resistance Note 1)
20 m/s2 With switch for vacuum Operating pressure range 0.3 to 0.6 MPa
Without pressure sensor/switch for vacuum Valve construction Poppet seal
Impact 150 m/s2
With pressure sensor Manual override Push type
resistance Note 2)
100 m/s2 With switch for vacuum Rated voltage 24 VDC, 12 VDC
Note 1) 10 to 500 Hz for 2 hours in each direction of X, Y and Z Power consumption 0.35 W
(During de-energizing) Lead wire Cross section: 0.2 mm2 (AWG24)
Note 2) 3 times in each direction of X, Y and Z (ZK2-LV∗∗-A) Insulator O.D.: 1.4 mm
(During de-energizing)
Note 3) Refer to y Valve assembly on page 925 for the valve model number.
Note 4) ZK2-VAR: After instantaneous energization of the supply valve (20 ms or
more), ON state is maintained without energization. Supply
valve turns off simultaneously when the release valve turns on.
ZK2-VAK: Supply valve turns off when is not energized. Select this type
when energy saving switch is used.
Ejector Specifications
Item Model ZK207 ZK210 ZK212 ZK215
Nozzle diameter [mm] 0.7 1.0 1.2 1.5
Max. suction Port exhaust specification [L/min (ANR)] 34 56 74 89
flow Note 5) Silencer exhaust specification [L/min (ANR)] 29 44 61 67
Air consumption Note 5) [L/min (ANR)] 24 40 58 90
Maximum vacuum pressure Note 5) [kPa] –91
Supply pressure range [MPa] 0.3 to 0.6
Standard supply pressure Note 6) [MPa] 0.35 0.4 (0.37)
Note 5) Values are based on standard of SMC measurements. They depend on atmospheric pressure (weather, altitude, etc.) and measurement method.
Note 6) The value in ( ) is for without valve. For nozzle size 07 to 12, the value is common to the ejectors with valve and without valve.
Weight
Single Unit
Single unit model Weight (g)
ZK2P00K (Vacuum pump system, Single unit, Without pressure sensor/switch for vacuum) 83
ZK2AK (Ejector system, Single unit, Without pressure sensor/switch for vacuum) 81
ZK2AN0NN (Ejector system, Single unit, Without valve) 54
ZK2 (One station for manifold, Without pressure sensor/switch for vacuum) 85
Manifold Base
1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations
Weight (g) 129 132 135 138 141 144 147 149 152 155
B 914
Vacuum Unit Series ZK2
ZK207
Exhaust Characteristics Flow-rate Characteristics
–100 50 –100
Suction flow
–90 90
Suction flow [L/min (ANR)]
ZH
Vacuum pressure [kPa]
ZK212
Exhaust Characteristics Flow-rate Characteristics
–100 100 –100
Suction flow
Air consumption [L/min (ANR)]
–90 90
Suction flow [L/min (ANR)]
(Port exhaust)
Vacuum pressure [kPa]
–80 80 –80
–70 Vacuum pressure 70
–60 Suction flow 60 –60
–50 (Silencer exhaust) 50
–40 Air consumption 40 –40
–30 30
–20 20 –20
–10 10 Port exhaust
Silencer exhaust
0 0 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0 20 40 60 80
Supply pressure [MPa] Suction flow [L/min (ANR)]
ZK215 Note 8) The following graphs show the characteristics of the ejector with valve. (Please contact SMC for without valve.)
Exhaust Characteristics Flow-rate Characteristics
–100 150 –100
Air consumption [L/min (ANR)]
–90 135
Suction flow [L/min (ANR)]
Vacuum pressure [kPa]
915 A
Series ZK2
ZK2(Ejector System)
–100 40 0.5
−90
50 0.5
10
0
0 1 2 3 4 5 6 7 8 9 10
Needle opening [Number of rotations]
The actual suction flow at the point of suction varies depending on the
piping conditions to the vacuum port.
Vacuum Pump System Flow-rate Characteristics of Flow Path and Vacuum Release
Port size Flow-rate characteristics of V → PV (Vacuum side) Flow-rate characteristics of PS → V (Vacuum release side)(∗)
PV port V port C[dm3/(s·bar)] b Cv C[dm3/(s·bar)] b Cv
ø6 ø8 0.39 0.14 0.09 0.20 0.06 0.04
(∗) When needle is fully open
Flow-rate characteristics are expressed in ejector vacuum pressure and suction flow. If suction flow
changes, the vacuum pressure will also be changed. Normally this relationship is expressed in
Pmax
Vacuum pressure
ejector standard operating pressure use. In graph, Pmax is maximum vacuum pressure and Qmax
is maximum suction flow. The values are specified according to catalog use. Changes in vacuum
P1 pressure are expressed in the below order.
1. When ejector suction port is covered and made airtight, suction flow becomes zero and vacuum
pressure is at maximum value (Pmax).
2. When suction port is opened gradually, air can flow through, (air leakage), suction flow increases,
0 Q1 Qmax but vacuum pressure decreases. (condition P1 and Q1)
Suction flow
3. When suction port is opened further and fully opened, suction flow moves to maximum value
(Qmax), but vacuum pressure is near zero (atmospheric pressure).
As described above, the vacuum pressure changes when the suction flow changes. In other words,
when there is no leakage from the vacuum (V) port, the vacuum pressure can reach its maximum,
but as the amount of leakage increases, the vacuum pressure decreases. When the amount of
leakage and the maximum suction flow become equal, the vacuum pressure becomes almost zero.
In the case when ventirative or leaky work should be adsorbed, please note that vacuum pressure
will not rise.
916
Vacuum Unit Series ZK2
Pressure Sensor/ZK2-PS-A (Refer to the PSE series in Best Pneumatics No. 6 and the Operation Manual for details.)
Model (Sensor unit: Standard model number) ZK2-PS1-A (PSE541) ZK2-PS3-A (PSE543)
Rated pressure range 0 to –101 kPa –100 to 100 kPa ZK2
Proof pressure 500 kPa
Applicable fluid Air/Non-corrosive gas/Incombustible gas ZQ
Output voltage 1 to 5 VDC
Output impedance Approx. 1 kΩ ZR
Power supply voltage 10 to 24 VDC ±10%, Ripple (P-P) 10% or less
Current consumption 15 mA or less
Accuracy ±2% F.S. (Ambient temperature at 25°C)
ZA
Linearity ±0.4% F.S. or less
Repeatability ±0.2% F.S. or less ZX
Effect of power supply voltage ±0.8% F.S. or less
Temperature characteristics ±2% F.S. or less (Ambient temperature: 25°C reference) ZM
Case Resin case
Material
Lead wire
Pressure sensing section Sensor pressure receiving area: Silicon, O-ring: HNBR
Oilproof heavy-duty cable 2.7 x 3.2 mm (Elliptic), 0.15 mm2 3 cores 3 m
ZMA
ZL
Digital Pressure Switch for Vacuum/ZK2-ZS-A (Refer to Best Pneumatics No.6 ZSE/ISE10 series and the Operation Manual for details.)
Model (Switch unit: Standard model number) ZK2-ZSE-A (ZSE10) ZK2-ZSF-A (ZSE10F) ZH
Rated pressure range 0 to –101 kPa –100 to 100 kPa
Set pressure range/Pressure display range
Proof pressure
10 to –105 kPa
500 kPa
–105 to 105 kPa
ZU
Minimum setting unit 0.1 kPa ZYY
Applicable fluid Air/Non-corrosive gas/Incombustible gas ZYX
Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (Protected against reverse connection)
Current consumption 40 mA or less
Switch output NPN or PNP open collector 2 outputs (selectable)
Maximum load current 80 mA
Maximum applied voltage 28 V (with NPN output)
Residual voltage 2 V or less (with load current at 80 mA)
Response time 2.5 ms or less (Anti-chattering function working: 20, 100, 500, 1000 or 2000 ms selected)
Short circuit protection Yes
Repeatability ±0.2% F.S. ±1 digit
Hysteresis mode
Hysteresis Variable (0 or above) Note)
Window comparator mode
Display 3 1/2 digit, 7-segment LED, 1-color display (Red)
Display accuracy ±2% F.S. ±1 digit (Ambient temperature at 25 ±3°C)
Indicator light Lights up when output is turned ON. OUT1: Green, OUT2: Red
Enclosure IP40
Operating temperature range Operating: –5 to 50°C, Storage: –10 to 60°C (with no freezing or condensation)
Operating humidity range Operating/Storage: 35 to 85% RH (with no condensation)
Environmental
Withstand voltage 1000 VAC for 1 minute between terminals and housing
resistance
Insulation resistance 50 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
Vibration resistance 10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 , in X, Y, Z directions, for 2 hours each (De-energized)
Impact resistance 100 m/s2 in X, Y, Z directions, 3 times each (De-energized)
Temperature characteristics ±2% F.S. (at 25°C in an operating temperature range of –5 and 50°C)
Oilproof heavy-duty vinyl cable
Lead wire
5 cores, Cross section: 0.15 mm2 (AWG26), Insulator O.D.: 1.0 mm
Standards Compliant with CE marking, RoHS
Note) If the applied voltage fluctuates around the set value, the hysteresis must be set to a value more than the fluctuating width, otherwise, chattering will occur.
917 A
Series ZK2
Digital Pressure Switch for Vacuum Ejector with Energy Saving Function
Model Specifications
Rated pressure range −100 to 100 kPa
Set pressure range −105 to 105 kPa
Proof pressure 500 kPa
Minimum setting unit 0.1 kPa
Applicable fluid Air/Non-corrosive gas/Incombustible gas
Power supply voltage 24 VDC ±10% Ripple (P-P) 10% or less (Protected against reverse connection)
Current consumption 40 mA or less
Switch output NPN or PNP open collector OUT1: General purpose, OUT2: Valve control
Maximum load current 80 mA
Maximum applied voltage 26.4 VDC
Residual voltage 2 V or less (with load current at 80 mA)
Response time 2.5 ms or less (Anti-chattering function working: 20, 100, 500, 1000 or 2000 ms selected)
Short circuit protection Yes
Repeatability ±0.2% F.S. ±1 digit
Hysteresis Hysteresis mode Variable (0 or above) Note)
Display 3 1/2 digit, 7-segment LED, 1-color display (Red)
Display accuracy ±2% F.S. ±1 digit (Ambient temperature at 25 ±3°C)
Indicator light Lights up when output is turned ON. OUT1: Green, OUT2: Red
Enclosure IP40
Environmental Operating humidity range 5 to 50°C
resistance Withstand voltage 1000 VAC for 1 minute between terminals and housing
Insulation resistance 50 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
Temperature characteristics ±2% F.S. (at 25°C in an operating temperature range of 5 and 50°C)
Lead wire Cable: 5 cores ø3.5, 2 m Cross section: 0.15 mm2 (AWG26) Insulator O.D.: 1.0 mm
Standards CE marking, RoHS
Note) If the applied voltage fluctuates around the set value, the hysteresis must be set to a value more than the fluctuating width, otherwise, chattering will occur.
Black OUT 1
1 kΩ Black OUT + 12 VDC Load 12 VDC
(Analog output) − to Load + 12 VDC
24 VDC White OUT 2 + White OUT 2
Load − to − to
24 VDC 24 VDC
Blue DC(−) FUNC FUNC Load
Blue DC(−) Blue DC(−)
Voltage output type: 1 to 5 V Max. 28 V, 80 mA Max. 80 mA
Output impedance: Approx. 1 kΩ Residual voltage: 2 V or less Residual voltage: 2 V or less
∗ The FUNC terminal is connected when using the copy function. (Refer to the Operation Manual.)
Main circuit
Standard Products
Port combination: PV ≠ PS = PD
Port
layout No. 1 Circuit example
Single unit: ZK2P00-
ZK2
PE PV
PV ZQ
PS
PE ZR
(= PD)
ZA
Supply valve Release valve
PS(= PD) ZX
V
P V ZM
System Vacuum pump
Body type Single unit Supply valve: Self-holding type Release valve: N.C. ZMA
Exhaust type Without silencer (R type)
Application Vacuum pressure — ZL
and Exhaust —
purpose Release pressure Same pressure as PS
ZH
Port combination: Common PV ≠ Common PS = Common PD
Port
layout No. 2 Circuit example
ZU
Single unit: ZK2Q00- ZYY
PE PE ZYX
Manifold: ZZK2-P2
Common PS Common PS EXH EXH
Common PD Common PD
(= Common PD) (= Common PD)
Common PS Common PS
Common PV Common PV Common PV Common PV
V
P P
System Vacuum pump
Body type Manifold Supply valve: Self-holding type Release valve: N.C. Supply valve: N.C. Release valve: N.C.
Exhaust type Without silencer (R type) V (K type) V
Application Vacuum pressure Common for each station
and Exhaust —
purpose Release pressure Same pressure as common PS
Port combination: PV = PS = PD
Port
layout No. 3 Circuit example
Single unit: ZK2A-
PV
(= PS = PD)
PV
EXH Note)
P V
System Ejector
Body type Single unit
Supply valve: Self-holding type Release valve: N.C.
Exhaust type Silencer exhaust (R type)
Application Vacuum pressure —
and Exhaust Released in operating environment Note) Nozzle size: 12, 15
purpose Release pressure Same pressure as PV
Refer to page 923 for the purpose of port and the operating pressure range.
919 A
Series ZK2
Standard Products
Port combination: PV = PS = PD
Port
layout No. 4 Circuit example
Single unit: ZK2B-
PV
(= PS = PD)
PV
EXH
(including PE)
Port exhaust
EXH
V
P V
System Ejector
Body type Single unit Supply valve: N.C. Release valve: Without release valve
Exhaust type Port exhaust (J type)
Application Vacuum pressure —
and Exhaust After piping, individual exhaust is necessary.
purpose Release pressure Same pressure as PV
6
Port exhaust
Supply valve: Self-holding type Release valve: N.C. port Supply valve: N.C. Release valve: N.C.
layout No.
(R type) V (K type) V
Single unit: ZK2F-
Manifold: ZZK2-A2 Note 1) For silencer common exhaust type, individual exhaust port is provided to each station.
Note 2) Silencer common exhaust and individual port exhaust cannot be mixed in the same manifold.
Common PV
Common PV (= Common PS
(= Common PS = Common PD)
= Common PD)
Individual EXH
(including PE)
System Ejector
Body type Manifold
Exhaust type Individual port exhaust
Application Vacuum pressure Common for each station
and Exhaust After piping, individual exhaust is necessary.
purpose Release pressure Same pressure as common PV
Refer to page 923 for the purpose of port and the operating pressure range.
920
Vacuum Unit Series ZK2
Option -D
Port combination: PV ≠ PS ≠ PD
Port
layout No. 7 Circuit example
Single unit: ZK2P00--D
ZK2
PE PV
PV ZQ
PD
PE ZR
PS PD
ZA
PS
ZX
V
Port combination: PV = PS ≠ PD
Port
layout No. 9 Circuit example
Single unit: ZK2A--D
PV
(= PS)
PV
PD
EXH Note)
PD
EXH EXH Exhaust port Note)
EXH
(including PE) (including PE) Silencer exhaust
EXH
V
System Ejector P V
Body type Single unit
Exhaust type Silencer exhaust
Supply valve: Self-holding type Release valve: N.C.
Vacuum pressure — (R type)
Application
Exhaust Released in operating environment
and
purpose Release PD pressure has to be
pressure supplied with PV pressure Note) Nozzle size: 12, 15
Refer to page 923 for the purpose of port and the operating pressure range.
921
Series ZK2
Option -D
Port combination: PV = PS ≠ PD
Port
layout No. 10 Circuit example
Single unit: ZK2B--D
PV
(= PS)
PV
PD
EXH
PD
(including PE)
Port exhaust
EXH
V
System Ejector P V
Body type Single unit
Exhaust type Port exhaust Supply valve: N.C. Release valve: N.C.
Vacuum pressure — (K type)
Application
Exhaust After piping, individual exhaust is necessary.
and
purpose Release PD pressure has to be
pressure supplied with PV pressure
Port
layout No. 12 Supply value: Self-holding type Release valve: N.C.
port Note1)
Supply valve: N.C. Release valve: N.C.
(R type) V (K type) V
Single unit: ZK2F--P
Manifold: ZZK2-A2-D Note 1) For silencer common exhaust type, individual exhaust port is provided to each station.
Common PV Note 2) Silencer common exhaust and individual port exhaust cannot be mixed in the same manifold.
Common PV (= Common PS)
(= Common PS) Common PD
Common PD (≠ Common PS)
(≠ Common PS) Individual EXH
(including PE)
V
System Ejector
Body type Manifold
Exhaust type Individual port exhaust
Vacuum pressure Common for each station
Application
Exhaust After piping, individual exhaust is necessary.
and
purpose Release Common PD pressure has to be
pressure supplied with common PV.
Refer to page 923 for the purpose of port and the operating pressure range.
922
Vacuum Unit Series ZK2
Option -L
Port combination: Individual PV ≠ Common PS = Common PD
Port
layout No. 13 Circuit example
Single unit: ZK2C--L
ZK2
Manifold: ZZK2-A1-L
Common PS
ZQ
Common PS
(= Common PD)
(= Common PD)
Individual PV ZR
Common EXH ZA
Common EXH
(including PE) (including PE) 13 PV 14 PV
EXH EXH ZX
Common PD Common PD
V Common PS
Common PV
Common PS
Common PV
ZM
System Ejector
Body type
Exhaust type
Manifold
Silencer common exhaust
ZMA
Vacuum PV pressure can be
Application pressure changed per station. Port exhaust Note 2) ZL
and Exhaust Released in operating environment EXH EXH
purpose
Release Same pressure for Individual
exhaust
ZH
pressure common PS and common PD P P
port Note1)
Supply valve: Self-holding type Release valve: N.C. V Supply valve: N.C. Release valve: N.C. V ZU
Port
layout No. 14 (R type) (K type)
ZYY
ZYX
Single unit: ZK2F--L Note 1) For silencer common exhaust type, individual exhaust port is provided to each station.
Manifold: ZZK2-A2-L Note 2) Silencer common exhaust and individual port exhaust cannot be mixed in the same manifold.
Common PS
Common PS (= Common PD)
(= Common PD) Individual PV
Individual EXH
(including PE)
V
System Ejector
Body type Manifold
Exhaust type Individual port exhaust
Vacuum PV pressure can be
Application pressure changed per station.
and Exhaust After piping, individual exhaust is necessary.
purpose
Release Same pressure for
pressure common PS and common PD
923
Series ZK2
Construction
!5 !3 !4 u q y o i w
e r !2 t !1 !0
With Pressure Sensor With Pressure Switch for Vacuum
Component Parts
No. Description Material Note
1 Valve body assembly Resin HNBR, NBR and steel are also used.
2 Needle assembly Brass Electroless nickel plated brass, resin, steel and NBR are used.
3 Ejector body assembly Resin HNBR, NBR and steel are also used.
4 Ejector assembly Resin NBR is also used.
5 Filter case assembly Resin Case body: Polycarbonate (Refer to Specific Product Precautions on page 938.)
Replacement Parts
No. Description Note
6 Valve assembly
7 Connector assembly Solenoid valve connector 3 wire (For double), 2 wire (For single)
8 One-touch fitting assembly Supply (PV) port standard: ø6, 1/4"
9 Sound absorbing material 10 pcs. per 1 set
10 Vacuum port adapter assembly With one-touch fitting and filter element (Case material: Polycarbonate)
11 Filter element Nominal filtration rating: 30 µm, 10 pcs. per set
12 Check valve For replacement or addition of manifold exhaust interference prevention (10 pcs. per set)
13 Vacuum pressure switch assembly With 2 screws and 1 gasket
14 Lead wire with connector
15 Pressure sensor assembly With 2 screws and 1 gasket
A 924
Vacuum Unit Series ZK2
t Mounting Note)
iOne-touch fitting assembly Nil Mounted to the single unit
(Purchasing order is available in units of 10 pieces.) L Mounted to the manifold
The length of the screw mounted to the ejector is different.
KJH 04 C2 Note) When ordering ejector without valve, select Nil for mounting.
Port size
04 ø4 One-touch fitting (Straight) Metric !4Lead wire with connector for pressure switch for vacuum
06 ø6 One-touch fitting (Straight) size (When individual lead wire is necessary, order with the port number below.)
03 ø5/32" One-touch fitting (Straight) Inch ¡Lead wire with connector for pressure switch for vacuum
07 ø1/4" One-touch fitting (Straight) size
ZS 39 5G
oSound absorbing material (10 pcs. per set) ¡Lead wire with connector for switch with energy saving function
q End plate D
y r
Component Parts
No. Description Material Note
1 End plate D assembly Resin HNBR, NBR and steel are also used.
2 End plate U assembly Resin Electroless nickel plated brass, resin, steel and NBR are used.
Replacement Parts
No. Description Note
3 Tension bolt assembly 2 pcs. per set
4 Port plug assembly Plug for changing PV port to single side supply type. (Common for mm and inch type)
5 Port plug assembly Plug for changing PS or PD port to single side supply type. (Common for mm and inch type)
6 One-touch fitting assembly Metric size: ø8, Inch size: ø5/16"
7 Sound absorbing material 2 pcs. per set - Material: Non-woven cloth (Silencer cover is not included.)
8 DIN rail Refer to Dimensions (from page 932 and after) for the recommended length for each number of manifolds stations.
9 Connector housing assembly Available connector is even number only (If you need a connector for odd number, specify the connector of the number you need + 1 station)
Note) When ordering a manifold “ZZK2---A” on page 912, q to e are delivered as a set.
L
rPort plug assembly tPort plug assembly 1.25 P = 12.5 5.25 7.5
926
Exploded View of Manifold Series ZK2
Tension bolt
Valve assembly
Junction box B
How to increase manifold stations
End plate U
[To increase the number of stations from odd number (1, 3, 5,
7, 9) in common wiring type to even number (2, 4, 6, 8, 10)]
Connector (Common wiring of odd number station has a vacant connector for one station. Easy to add a station.) ZK2
1) Remove the tension bolt.
2) Remove the end plate U. ZQ
3) Remove the valve assembly of a single unit for extra station(s) for manifold.
4) Remove the switch assembly if it is present. (Be careful not
to drop the gasket. Refer to Fig.1 )
ZR
5) Remove the junction box B (top) using a precision
U sid
screwdriver. (Refer to Fig.2 ) ZA
e 6) Mount the extra connector to the junction box B. (Refer to
i
Fig.3 ) (Engage the recess of the connector and the
protrusion of the junction box B, referring to Fig.3-A ) ZX
7) Mount a single unit for extra station(s) for manifold to the end sur-
Vacuum pressure face of U side. (Do not let the gasket or lead wire get caught.) ZM
switch assembly 8) Mount the end plate U with the appropriate length of tension
Junction box A
bolts for the number of stations required. (Tightening torque:
0.75 N·m.) ZMA
D sid 9) Mount the junction box B to the junction box A.
e
10) Assemble the valve assembly. (Tightening torque: 0.15 N·m) ZL
The side with Finger [To increase the number of stations from even number
Connector square hole
How to remove the
junction box B to odd number, or increase two stations or more] ZH
recess
faces the body. 1) Remove the valve assembly for all stations. (Single unit for
extra station is also removed.) ZU
2) Remove the switch assembly if it is present. (Be careful not
to drop the gasket. Refer to Fig.1 ) ZYY
3) Remove the junction box B (top) for all stations using a ZYX
Protrusion of Fig. 3 precision screwdriver. (Refer to Fig.2 ) (Remove the junction
junction box B Fig. 2 box B from D side.)
Clip in. 4) Remove all connectors mounted to the junction box B. (Be
careful not to break the connector clip.)
Fig. 3-A
5) Remove the tension bolt.
6) Remove the end plate D assembly.
When ordering ejector for pump
7) Remove the connector housing assembly from the end plate
system, spacer is included.
D assembly. (Refer to Fig.4 )
Gasket 8) Mount the connector housing assembly for extra station(s) to
the end plate D assembly. (Refer to Fig.4 ) (Insert two clips
Fig. 1
Pump spacer∗ of the housing mounting surface to the square holes of the
(Part No.: ZK2-SS1-A) end plate, and slide the connector housing assembly.)
9) Remove the end plate U. (Be careful not to drop the gasket.)
End plate D assembly 10) Mount a single unit for extra station(s) for manifold to the end
surface of U side. Do no let the gasket caught.
11) Mount the end plate U and D with the appropriate length of tension bolts
for the number of stations required. (Tightening torque: 0.75 N·m.)
U side 12) Mount the connector for all stations to the junction box B.
Finger
(Refer to Fig.3 ) (Engage the recess of the connector and
5 Finger the protrusion of the junction box B. (Refer to Fig.3-A )
4
Assembled unit 3 D side 13) Mount the junction box A to the junction box B.
2
1 Push the wires down the side and mount the junction box A
to the junction box B following a decreasing mark tube
Square hole numbers from U side. (Do not let the lead wire get caught.)
Mark tube 14) Assemble the valve assembly. (Tightening torque: 0.15 N·m)
(Station number indication) Fig. 4
∗ When adding a pump system, the pump spacer for extra
o station is required separately.
oConnector housing assembly Plug (For One-touch fitting) (Purchasing order is available in units of 10 pieces.)
Mounted onto ports which are not used (PV, PS, PD, etc.)
ZK2 CH 2 04 A L
A
Applicable stations
KQ2P 06
02 For 2 stations manifold
04 For 4 stations manifold
06
ød
26.4
∗1 Air is exhausted from the slit of both end
10.4 surfaces in case of silencer exhaust. Do not
79.8 B
cover both sides. Release at least one side.
75.6 ∗2 For port exhaust, air is exhausted
from the One-touch fitting.
∗3 Pilot pressure exhaust is common
2 x ø4.5 Mounting hole
E∗1,∗3 with ejector exhaust.
45.9
37.4
hole.
8.4
19.4
ZK2P00 KR NL2-
Vacuum pump system, Single unit, With supply valve/release valve, Without pressure sensor/switch
79.8 B
75.6
PV port type B
2 x ø4.5 Mounting hole Metric size 06 ø6 9.7
Inch size 07 ø1/4" 12.3
2.6
Pilot pressure exhaust port Vacuum pressure supply (PV) port
Vacuum break flow adjustment needle
Hexagon width across flats C
84
80
27.5
Fully open 10
54.8
45.9
8.6
37.4
8.4
Metric size: ø4
Inch size: ø5/32"
∗1 16.5 38.5 Suction filter 3.5
15 Vacuum (V) port
78.8 A
V port type A C
∗1 Refer to page 931 for dimensions Metric 06 ø6 8.25 4
Locking position
with a bracket mounted. size 08 ø8 11.4 6
Inch 07 ø1/4" 10.8 4.76
size 09 ø5/16" 11.4 6
928
Vacuum Unit Series ZK2
26.4
10.4
surfaces in case of silencer exhaust. Do not
cover both sides. Release at least one side.
ZR
79.8 B ∗2 For port exhaust, air is exhausted
75.6 from the One-touch fitting. ZA
∗3 Pilot pressure exhaust is common
with ejector exhaust.
2 x ø4.5 Mounting hole
E∗1,∗3
ZX
Air pressure supply (PV) port ZM
∗5
27.5
45.9
hole.
ZH
8.4
19.4
ZU
∗4 16.5 38.5 Suction filter
15 Vacuum (V) port
78.8 A ZYY
ZYX
V port type A C
∗4 Refer to page 931 for dimensions Metric 06 ø6 8.25 4
Locking position
with a bracket mounted. size 08 ø8 11.4 6
Inch 07 ø1/4" 10.8 4.76
size 09 ø5/16" 11.4 6
ZK2 AB N0NN-
Ejector system, Single unit, Without valve, Without pressure sensor/switch
Exhaust (EXH) port
E∗2 Metric size: 08 (ø8)
Inch size: 09 (ø5/16")
PV port type B
Metric size 06 ø6 9.7
∗4
27.5
hole.
8.4
19.4
Suction filter
∗3 15 16.5 38.5
Vacuum (V) port
78.8 A
V port type A C
∗3 Refer to page 931 for dimensions Metric 06 ø6 8.25 4
Locking position
with a bracket mounted. size 08 ø8 11.4 6
Inch 07 ø1/4" 10.8 4.76
size 09 ø5/16" 11.4 6
929
Series ZK2
9.9
E∗2,∗3
(300: Lead wire length)
26.4
79.8 B
10.4
75.6
Fully open 10
45.9
38.7
37.4
8.4
19.4
ZK2 AB KR L-
A to J
Ejector system, Single unit, Manual override (Supply valve) 33.5 6 Manual override (Supply valve)
89
26.4
79.8
10.4
75.6 B
(30)
LED display
79
button (UP)
75
27.5
57.6
button (DOWN)
Fully open 10
45.9
37.4
8.4
19.4
Suction filter
∗3 15 Vacuum (V) port
16.5 38.5 3.5
1.1 104 A
∗1 Air is exhausted from the slit of both end surfaces in case of V port type A C PV port type B
silencer exhaust. Do not cover both sides. Release at least
Metric 06 ø6 8.25 4 Metric size 06 ø6 9.7
one side. size 08 ø8 11.4 6 Inch size 07 ø1/4" 12.3
∗2 For port exhaust, air is exhausted from the One-touch fitting.
Inch 07 ø1/4" 10.8 4.76
∗3 Pilot pressure exhaust is common with ejector exhaust.
∗4 Refer to page 931 for dimensions with a bracket mounted. size 09 ø5/16" 11.4 6
A 930
Vacuum Unit Series ZK2
14.5
ZK2
2 x ø4.6 15
26.5
5.8
5 M4 Nut ZQ
ZR
M4 x 20
ZA
ZX
∗
ZM
46.4
ZMA
8.9
∗ Mounting bracket for single unit (Option), [Nuts and bolts are included.]
33.5 Part number: ZK2-BK1-A ZL
1
ZH
ZU
ZYY
ZYX
931
Series ZK2
10
4.8
2 x Common pilot pressure
supply (PS) port ∗1
(5.3)
(35)
(L5)
70
88.8
(75.6)
(L6)
(54.8)
(5.5)
32
A
12.8
Fully open 10
10.5
37.4
38
26.4
2 x Common exhaust
8.4
(EXH) port ∗2
3.5
n x Individual exhaust 10.5 n x Vacuum (V) port
(EXH) port ∗3
15 33 (Built-in suction filter)
(n−1) x 15
(mm)
Hexagon width Number of
Port type A across flats B C D stations 1 2 3 4 5 6 7 8 9 10
Metric 06 8.3 4 9.7 8.7
L1 30 45 60 75 90 105 120 135 150 165
size 08 11.4 6 — —
L2 45 60 75 90 105 120 135 150 165 180
Inch 07 10.8 4.76 12.3 11.3
size
L3 56.8 71.8 86.8 101.8 116.8 131.8 146.8 161.8 176.8 191.8
09 11.4 6 — —
L4 67.5 82.5 97.5 112.5 127.5 142.5 157.5 172.5 187.5 202.5
L5 62.5 75 87.5 112.5 125 137.5 150 162.5 187.5 200
L6 73 85.5 98 123 135.5 148 160.5 173 198 210.5
∗1 Common pilot pressure supply port is only for vacuum pump system. (mm: ø6 inch: ø1/4")
∗2 Pump system with individual exhaust port type does not have exhaust outlet.
∗3 When individual exhaust port type is selected (Body type: F)
∗4 Only when common PD port type option (Symbol: -D) is selected (mm: ø6 inch: ø1/4")
∗5 Select an option of How to Order of manifold to fix the manifold to DIN rail.
∗6 For silencer common exhaust type, air is also exhausted from individual exhaust port of each station. (Ejector system)
932
Vacuum Unit Series ZK2
15.4
3.8 38.7 (Approx. 3000: Lead wire length) 2 x Common pilot pressure 1.5
supply (PS) port ∗1
10
ZR
4.8
ZA
(5.3)
ZX
ZM
(35)
(99)
(L5)
70
88.8
ZMA
(5.5)
(L6)
(54.8)
ZL
32
ZH
12.8
ZU
Fully open 10
A
10.5
Manual override (Release valve)
ZYY
Manual override (Supply valve) ZYX
75 (Ejector system)
62
53
37.4
38
36
8.4
B
26.4
C
(mm)
Hexagon width Number of
Port type A across flats B C D stations 1 2 3 4 5 6 7 8 9 10
Metric 06 8.3 4 9.7 8.7
size
L1 30 45 60 75 90 105 120 135 150 165
08 11.4 6 — —
L2 45 60 75 90 105 120 135 150 165 180
Inch 07 10.8 4.76 12.3 11.3
size
L3 56.8 71.8 86.8 101.8 116.8 131.8 146.8 161.8 176.8 191.8
09 11.4 6 — —
L4 73.5 88.5 103.5 118.5 133.5 148.5 163.5 178.5 193.5 208.5
L5 75 100 112.5 125 137.5 150 175 187.5 200 212.5
L6 85.5 110.5 123 135.5 148 160.5 185.5 198 210.5 223
∗1 Common pilot pressure supply port is only for vacuum pump system. (mm: ø6 inch: ø1/4")
∗2 Pump system with individual exhaust port type does not have exhaust outlet.
∗3 When individual exhaust port type is selected (Body type: F)
∗4 Only when common PD port type option (Symbol: -D) is selected (mm: ø6 inch: ø1/4")
∗5 Select an option of How to Order of manifold to fix the manifold to DIN rail.
∗6 For silencer common exhaust type, air is also exhausted from individual exhaust port of each station. (Ejector system)
933
Series ZK2
26.3
4.8
Triangle mark
(5.3)
(35)
(99)
(L5)
70
88.8
(L6)
(54.8)
(5.5)
32
12.8
∗6
A
10.5
Manual override (Supply valve)
75 (Ejector system)
62
53
37.4
38
36
26.4
C
8.4
2 x Common exhaust
(EXH) port ∗2 n x Vacuum (V) port
(Built-in suction filter)
∗3
3.5 10.5
15 33
(n−1) x 15
(mm)
Hexagon width Number of
Port type A across flats B C D stations 1 2 3 4 5 6 7 8 9 10
Metric 06 8.3 4 9.7 8.7
size
L1 30 45 60 75 90 105 120 135 150 165
08 11.4 6 — —
L2 45 60 75 90 105 120 135 150 165 180
Inch 07 10.8 4.76 12.3 11.3
size
L3 56.8 71.8 86.8 101.8 116.8 131.8 146.8 161.8 176.8 191.8
09 11.4 6 — —
L4 73.5 88.5 103.5 118.5 133.5 148.5 163.5 178.5 193.5 208.5
L5 75 100 112.5 125 137.5 150 175 187.5 200 212.5
L6 85.5 110.5 123 135.5 148 160.5 185.5 198 210.5 223
∗1 Common pilot pressure supply port is only for vacuum pump system. (mm: ø6 inch: ø1/4")
∗2 Pump system with individual exhaust port type does not have exhaust outlet.
∗3 When individual exhaust port type is selected (Body type: F)
∗4 Only when common PD port type option (Symbol: -D) is selected (mm: ø6 inch: ø1/4")
∗5 Select an option of How to Order of manifold to fix the manifold to DIN rail.
∗6 Applicable connector: Connector for flat ribbon cable (26P)(MIL-C-83503 compliant)
∗7 For silencer common exhaust type, air is also exhausted from individual exhaust port of each station. (Ejector system)
A 934
Vacuum Unit Series ZK2
A D-sub connector (25P) conforming to MIL standards A flat ribbon cable connector (26P) conforming to MIL
is used. standards is used.
Optional Specifications/Functions/Applications
935 B
Vacuum Unit Series ZK2
Cable Assembly
1
Terminal Lead wire Dot
37.5 (26P)
0.3 mm2 x 25 pins
no. color marking
O.D. ø1.4
1 Black None
� ø10
2 Brown None ZA
26
25
3 Red None
015
Seal (Length)
4 Orange None (15.6) ZX
5 Yellow None
L
ZM
L
Connector
8
9
Purple
Gray
White
Black
ZMA
Flat Ribbon Cable Connector Assembly (Option)
DB-25SF-N 10 White Black
8
55 12 Yellow Red
1.5 m AXT100-FC26-1
Socket side 13 Orange Red
3m AXT100-FC26-2 ZH
14···············25 14 Yellow Black
5m AXT100-FC26-3
Terminal no. 15 Pink Black
∗ For other commercial connectors, use a 26-pin type with strain ZU
16
Connector manufacturers’
Electrical Characteristics
example
Item Property
• Fujitsu Limited
Conductor • Japan Aviation Electronics
65 or
resistance
less Industry, Ltd.
Ω/km, 20°C
• J.S.T. Mfg. Co., Ltd.
Voltage limit • Hirose Electric Co., Ltd.
V, 1 min, AC 1000
Insulation 5 or
resistance more
MΩ/km, 20°C
935-1 A
Series ZK2
Specific Product Precautions 1
Be sure to read the below before handling. Refer to front matter 35 for Safety Instructions.
For Vacuum Equipment Precautions, refer to pages 899 to 901 and Operation Manual. The
Operation Manual can be downloaded from the SMC website, http://www.smcworld.com
Warning Warning
1. Manual override operation 4. Wiring specifications and light/surge voltage
• Manual override is non-locking push type. Push the suppressor
manual override with a screwdriver of a diameter smaller Wiring should be connected as shown below. Connect with
than indicated in the diagram until it reaches the end. the power supply respectively. (Solenoid valve is non-polar
Release valve type.)
manual override
Green Single solenoid (Without release valve) Double solenoid (With release valve)
Supply valve Lead wire: Red Lead wire: White LED (Green)
manual override C [COM] LED (Red) B [SOL.b]
Orange (+, −) (−, +)
Supply valve Release valve Coil
Coil
U
U
Lead wire: Red
A [SOL.a] C [COM]
.2 (−, +) (+, −)
ø3 Lead wire: Black
Supply valve Coil
U
Lead wire: Black
A [SOL.a]
(−, +) LED (Red)
3. Default setting
When the valve assembly is delivered, the supply valve is
on the OFF position, but it may be on the ON position due
to the vibration or impact during transportation or device
installation. Turn to the OFF position manually or by ener- 5. Continuous duty
gizing before use. If a supply valve/release valve is energized continuously
for a long time, the rise in temperature due to heat-up of
the coil may cause a decline in solenoid valve perfor-
mance, reduce service life, or have adverse effects on
peripheral equipment. When the energizing time per day is
longer than non-energizing time, use self-holding linked
type valve using instantaneous energizing.
936
Series ZK2
Specific Product Precautions 2
Be sure to read the below before handling. Refer to front matter 35 for Safety Instructions.
For Vacuum Equipment Precautions, refer to pages 899 to 901 and Operation Manual. The
Operation Manual can be downloaded from the SMC website, http://www.smcworld.com
A B ZL
Caution ZH
1. Installation/Removal of connector
• To install the connector, hold the cover and insert the ZU
connector straight pushing the connector lever with your ZYY
finger. Ensure that the connector lever clip is properly • When installing the filter, insert the filter to the end so that ZYX
inserted onto mating part. there is no gap or bending between the filter and the
• To remove the connector, hold the cover and pull out the vacuum port adapter. The gap or bending will cause the
connector straight pushing the connector lever clip. element to deform inside the case.
Lever Connector
• Put the filter back into the filter case following this proce-
Mating part dure in reverse.
Cover
• To mount the vacuum port adapter into the filter case,
turn the adapter so that the mating mark of the adapter
Note) Do not pull the lead wire and the case are aligned. (Rotation stops there.)
with a force of 25 N or Lower face
more, as this may damage Mating mark
the connector or cover.
Black Black
Width across flats
Nil 300 mm
6 600 mm V port size Width across flats
10 1000 mm Note) When ordering, put the connector ø6 4
20 2000 mm assembly part number to the prod- ø8, 5/16" 6
30 3000 mm uct part number without connector. ø1/4" 4.76
937
Series ZK2
Specific Product Precautions 3
Be sure to read the below before handling. Refer to front matter 35 for Safety Instructions.
For Vacuum Equipment Precautions, refer to pages 899 to 901 and Operation Manual. The
Operation Manual can be downloaded from the SMC website, http://www.smcworld.com
Caution Caution
2. Filter case maintenance • The exhaust resistance should be as small as possible to
• When the filter case is dirty, it can be removed and obtain the full ejector performance.There should be no
cleaned. shield around the exhaust port for the silencer exhaust
To remove the filter case, insert a precision screwdriver specification. When the product is installed, one of the ports
into the groove of the release lever and push in direction should be open to atmosphere.
(q), and slide the filter case in direction (w).
Body
Groove
Release lever
q
Filter case
w
Exhaust port
(On both sides)
Hook A C Hook B
w
q
D
Note) If excess force is applied to the filter case, hook A and B may
break. Handle with care.
A 938
Series ZK2
Specific Product Precautions 4
Be sure to read the below before handling. Refer to front matter 35 for Safety Instructions.
For Vacuum Equipment Precautions, refer to pages 899 to 901 and Operation Manual. The
Operation Manual can be downloaded from the SMC website, http://www.smcworld.com
Clip ZL
Vacuum pressure ZH
Sound absorbing
material Projection of diffuser
Caution
Projection • Port size
Size
Diffuser hole viewed from the port plug Port Ejector System Vacuum Pump System
Metric Inch Metric Inch
(Procedure to put parts back together) PV ø6 ø1/4" ø6 ø1/4"
7) Insert the port plug. V ø6, ø8 ø1/4", ø5/16" ø6, ø8 ø1/4", ø5/16"
EXH ø8 ø5/16" — —
8) Push the release lever until it stops. Insert the clip into the (Port exhaust)
groove using the lever hole. (Push completely to the end.) PE EXH Common Port open to atmosphere ∗1)
Note) Do not pull or bend the two projections at the end surface of the PS — — ø4 ø5/32"
diffuser. These are spacers to prevent the displacement of the PD ∗2) M3 — M3 —
diffuser and they may break if force is applied. — : Not applicable
∗1) Piping for PE port is available as an option. (Refer to page 911.)
Operating Supply Pressure ∗2) With PD port type is available as an option. (Refer to page 911.)
Caution
• Use the product within the specified supply pressure range.
Operation over the maximum operating pressure can cause
damage to the product.
The parts around the vacuum port of this product are
designed to be used with vacuum pressure. With the vacuum
pump system, since air is not released to the atmosphere
from a silencer, the applied air for vacuum release increases
the internal pressure of the vacuum port. Select the vacuum
pad which shape allows smooth exhaust of release air to the
atmosphere and avoid clogging.
939
Series ZK2
Specific Product Precautions 5
Be sure to read the below before handling. Refer to front matter 35 for Safety Instructions.
For Vacuum Equipment Precautions, refer to pages 899 to 901 and Operation Manual. The
Operation Manual can be downloaded from the SMC website, http://www.smcworld.com
Caution Caution
1. Single unit can be mounted to DIN rail or wall • Manifolds can be mounted onto the floor using M4 holes on
using the holes in the body (2 x ø4.5). the end plate.
• When mounting the ejector to DIN rail, unlock the filter • It is possible to mount the manifold onto the DIN rail by
case assembly beforehand. (Refer to maintenance proce- manifold option.
dure on page 938.) · Hook the mounting bracket of the end plate to DIN rail from direction (q).
• Hook the ejector onto the DIN rail from direction (q). · Mount the ejector onto the DIN rail by pushing it down in direction (w).
• Mount the ejector onto the DIN rail by pushing it down in · Use a 50 mm or longer phillips head screwdriver to tighten the
direction (w). mounting bracket (e). (Tightening torque: 0.9 ±0.1 N·m)
• Push the filter case assembly in direction (e) until it is · Removal should be performed by following the mounting procedure
locked. in reverse.
50 or longer
e
w
q w e
q
• To hold the ejector onto the DIN rail, hold it from both
q
sides using the stopper brackets.
Mounting bracket
Manifold Silencer
Caution
• Ejector system manifold silencer common exhaust type has a
sound absorbing material in the end plate. If the sound absorb-
ing material is clogged, ejector performance is deteriorated,
Stopper bracket leading to suction failure or response delay. Regular replace-
Part number: TXE1-SMC ment of the sound absorbing material is recommended.
2. To mount a single unit onto the floor, use the Replacement Procedure
optional bracket. • Insert a precision screwdriver to notch (A) of the end plate
and remove a clip (L) (q).
• Insert a precision screwdriver to notch (B) and remove the
silencer cover (w).
• Pull out the sound absorbing material from the silencer cover (e).
M4 Nut
• Mounting of a new element should be performed by follow-
ing the removal procedure in reverse.
M4 x 20
End plate
∗
Clip L
e
∗ Mounting bracket for single unit (Option), [Nuts and bolts are included.]
Silencer cover
Part number: ZK2-BK1-A q
w
Notch A Notch B
Sound absorbing material
(ZK2-SE21-A)
A 940
Series ZK2
Specific Product Precautions 6
Be sure to read the below before handling. Refer to front matter 35 for Safety Instructions.
For Vacuum Equipment Precautions, refer to pages 899 to 901 and Operation Manual. The
Operation Manual can be downloaded from the SMC website, http://www.smcworld.com
Handling of Pressure Switch for Vacuum Assembly Handling of Digital Pressure Switch with Energy Saving Function
Handling Mounting
Caution Caution
1. Incorrect wiring can cause the switch to be damaged 1. Tighten to the specified tightening torque.
or malfunction. Connections should only be made If the tightening torque is exceeded, the mounting screws
when the power supply is turned off. and the pressure switch may break. Insufficient torque may
2. Do not attempt to insert or pull out the connector cause displacement of the pressure switch and loosening
from the switch while the power is on. of the mounting screws.
Tightening torque: 0.08 to 0.10 N·m
Otherwise, it may cause switch output malfunction.
2. If a commercially available switching power supply is
3. Malfunctions stemming from noise may occur if
used, be sure to ground the frame ground (FG) terminal.
the wire is installed in the same route as that of
power or high-voltage cable. 3. Do not drop, hit or apply shock to the product.
Wire the switch independently. The internal parts of the pressure switch may get damaged
and cause malfunction.
4. Be sure to connect the ground terminal F.G. to
ground when using a commercially available 4. Do not pull the lead wire with force, or lift the product
switching power supply. by pulling the lead wire. (Tensile strength within 20 N)
Hold the product body when handling to prevent damage,
failure or malfunction.
Environment The pressure switch will be damaged, leading to failure
and malfunction.
Warning 5. Eliminate any dust left in the piping by using a blast
1. The structure of pressure switches is not of air before connecting the piping to the product.
intended to prevent explosion. Failure or malfunction may occur.
Never use in an atmosphere of flammable gas or explosive gas.
6. Do not insert metal wires or other foreign objects
into the pressure port.
Caution The pressure sensor may get damaged, leading to failure
1. The product is CE marked, but not immune to and malfunction.
lightning strikes.
7. If the fluid contains foreign matter, install and
Take measures against lightning strikes in your system.
connect a filter or mist separator to the inlet.
2. Do not use the switches in locations where static Failure, malfunction or inaccurate measurements from the
electricity would be problematic. pressure switch may occur.
Otherwise, it may result in the system failure and trouble.
Section A (Lever)
• Do not attempt to insert or pull out the connector from the switch while
the power is on. Otherwise, it may cause switch output malfunction.