Vol 1 - Cab Wiring

032 (Red) (Battery Power)

640 (Blue) (Key Power)

021 (Orange) (Starting)

640 (Blue) (Key Power) CIRCUIT ISOLATED

CLICK HERE TO VIEW THE SCHEMATIC


UTILIZE HYPERTEXT TO NAVIGATE TO COMPONENTS AND THEIR MACHINE LOCA- SYMBOLS AND DEFINITIONS PAGE
TION QUICKLY. HYPERTEXT IS INDICATED BY TEXT THAT IS BLUE AND UNDERLINED. ELECTRICAL SYMBOLS

Pressure Temperature Level


Switch Switch Switch Circuit Breaker

BASIC HYDRAULIC SYMBOLS

Fluid Pump Spring


Variability
Conditioner or Motor (Adjustable)

HOTKEYS (Keyboard Shortcuts)

FUNCTION KEYS
Zoom In “CTRL” / “+”
Zoom Out “CTRL” / “-”
Fit to Page “CTRL” / “0” (zero)
Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
WHEN ONLY ONE CALLOUT IS SHOWING ON A Search “CTRL” / “SHIFT” / “F”

MACHINE VIEW, CLICKING ON THIS BUTTON WILL


VIEW ALL CALLOUTS MAKE ALL OF THE CALLOUTS VISIBLE. THIS
Due to different monitor sizes and PDF reader
preferences there may be some variance in linked
BUTTON IS TYPICALLY LOCATED IN THE TOP RIGHT schematic locations. This document is best viewed at
CORNER OF EVERY MACHINE VIEW PAGE. a screen resolution of 1024 X 768.

© 2023 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE


WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
Caterpillar: Non-Confidential.
SCHEMATIC SYMBOLS AND DEFINITIONS
VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC
ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

PILOT CONTROL Line Restriction


MAIN AUX.

2-Section
RELEASED PRESSURE Variable and Pressure
ROTATING SHAFTS Compensated
Pump

External Return Internal Return Unidirectional Bidirectional


REMOTE SUPPLY PRESSURE Attachment Pump: Variable and
Pressure Compensated

Internal
Simplified Complete Supply Pressure Hydraulic Pneumatic
Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.). 111-7898 3E-5179
No circle indicates that the wire cannot be disconnected from the component. Part Number: for 1
Connector Plug
Ground (Wired): This indicates that the component is connected to a grounded wire. 2
The grounded wire is fastened to the machine.
Plug Receptacle
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
harness (C1, C2, C3, ...)
a normally open reed switch; it opens the contacts of a normally closed reed switch.
L-C12
3E-5179
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure. 5A
T Its resistance changes to give an indication to the gauge of the temperature or pressure. Component
Fuse (5 Amps) 9X-1123 Part Number
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. 325-AG135 PK-14
It has a coil that makes an electromagnet when current flows through it. Harness identification code:
This example indicates wire group 325, Wire Gauge*
The electromagnet can open or close the switch part of the relay. wire 135 in harness "AG". Wire Color
*Wire gauge is shown in AWG (American Wire Gauge)
Solenoid: A solenoid is an electrical component that is activated by electricity. but could also be shown in metric denoted with mm
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.

© 2023 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE


WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
Caterpillar: Non-Confidential.
M0165635
September 2023

320 and 323 Excavator


People Detection kit
Electrical System
BR61-UP GKW1-UP
ZBN1-UP
XAR1-UP
DYT1-UP
NMC1-UP
KFE1-UP
MYK1-UP
FMS1-UP
ELW1-UP
BR91-UP
YBL1-UP
KTY1-UP
NDL1-UP
LTN1-UP
DWF1-UP
KPE1-UP

PUBLICATIONS.CAT.COM
© 2023 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
Caterpillar: Non-Confidential
COMPONENT LOCATION

Schematic Machine
Component
Location Location
Camera - Left View D-7 1
Camera - Rear View E-7 2
Camera - Right View E-7 3
Control Gp - Communication (A6N2) (Electronic) E-4 4
Control Gp - Communication (A6N2) (Network Manager) E-5 5
Converter - DC - DC E-5 6
Fuse Base C-1 12
Ground 200 D-7 7
Ground 235 D-7 8
Relay As (24 V) E-5 9
Resistor - CAN (J1939) Data Link C-7 10
Resistor - Local Can Data Link for Display C-7 11
CONNECTOR LOCATION

Schematic
Connector Number
Location
CONN 1 C-7
CONN 2 C-7
CONN 3 E-3, D-2
The connectors shown in this chart are for harness
to harness connectors. Connectors that join a
harness to a component are generally located at or
near the component. See the Component Location
Chart.
C-C1
368-4832

1
2
3
4
5
6
7
8
HV-C18 9
9X-1054 10
11
TO MATING CONNECTOR
160-HV2 PU-18-GXL 5 12
C592-HV36 WH-18-GXL C592-HV36 WH-18-GXL 2
85
86 13
C814-HV37 GN-12-GXL 160-HV1 PU-12-GXL (9) RELAY AS 24 V
CONN 3
30
1 14
C814-HV3 GN-16-GXL 3
87A
568-2023 15
C814-HV38 GN-16-GXL C814-HV37 GN-12-GXL 4
87
16 CONNECTS TO F-C1
17 LOC D-2
160-HV1 PU-12-GXL 18
160-HV2 PU-18-GXL 19
160-HV10 PU-18-TXL 20
160-HV39 PU-18-TXL 21
22
HV-C7 (6) DC-DC CONVERTER 23
200-HV4 BK-16-GXL 155-2273 340-7160 24
200-HV5 BK-16-GXL 25
C814-HV3 GN-16-GXL 1 24V + INPUT 26
C814-HV38 GN-16-GXL 2 IGNITION 27

H2
200-HV4 BK-16-GXL 3 GROUND 28
160-HV10 PU-18-TXL T801-HV14 PU-16-GXL 4 12V+ UNSWITCHED 29
T801-HV20 PU-20-TXL T801-HV14 PU-16-GXL 5 12V+ SWITCHED 30
133-HV15 RD-18-TXL T801-HV19 PU-20-TXL 200-HV5 BK-16-GXL 6 GND 31
133-HV21 RD-14-TXL T801-HV17 PU-20-TXL 32
160-HV10 PU-18-TXL 33 FUSE
UM-C1 (5) CONTROL GP-COMMUNICATION (A6N2) (NETWORK MANAGER) 34
483-2761 494-6473 UN-C2 (4) CONTROL GP-COMMUNICATION (A6N2) (ELECTRONIC) 35
(2) REAR VIEW CAMERA UM-C3 483-2761 494-6472 36
563-9823 490-0571 1 1 37
2 2 1 1 38
ETHERNET+ 1 CBL-UM2:1820-UM2 WH-BU-20 3 3 2 2 39
ETHERNET- 2 CBL-UM2:1821-UM1 BU-20 4 4 3 3 40
5 5 4 4 41
6 6 5 5 42
7 7 6 6 43
12V+ POWER 1 T801-HV17 PU-20-TXL 8 8 7 7
H2
44
GROUND 2 200-HV8 BK-20-TXL 9 9 8 8 45
10 10 9 9 46
HV-C10 11 11 10 10 47
490-0578 12 12 11 11 48
13 13 12 12 49
14 14 13 13 50
T801-HV17 PU-20-TXL 15 15 14 14 51
(3) RIGHT VIEW CAMERA UM-C2 T801-HV19 PU-20-TXL 16 16 15 15 52
563-9823 490-0571 T801-HV20 PU-20-TXL 17 17 16 16 53
CBL-UM1:1823-UM1 BU-20 18 18 ETH BR4- 17 17 54
ETHERNET+ 1 CBL-UM1:1822-UM2 WH-BU-20 CBL-UM2:1820-UM2 WH-BU-20 CBL-UM1:1822-UM2 WH-BU-20 19 19 ETH BR4+ 18 18 55
ETHERNET- 2 CBL-UM1:1823-UM1 BU-20 CBL-UM2:1821-UM1 BU-20 CBL-UM2:1820-UM2 WH-BU-20 20 20 ETH BR3+ 19 19 56
CBL-UM1:1822-UM2 WH-BU-20 CBL-UM2:1821-UM1 BU-20 21 21 ETH BR3- 20 20 57
CBL-UM1:1823-UM1 BU-20 22 22 21 21 133-HV21 RD-14-TXL 58 FUSE
CBL-UN2:1824-UN2 WH-BU-20 23 23 22 22 59
12V+ POWER 1 T801-HV19 PU-20-TXL CBL-UN2:1825-UN1 BU-20 24 24 23 23 60
GROUND 2 200-HV9 BK-20-TXL 25 25 24 24 61
C592-HV36 WH-18-GXL 26 26 25 25 62
HV-C9 C592-HV35 WH-20-TXL 27 27 26 26
490-0578 28 28 27 27
200-HV6 BK-20-TXL 29 29 28 28
30 30 29 29
200-HV9 BK-20-TXL 31 31 30 30
200-HV8 BK-20-TXL 32 32 31 31
(1) LEFT VIEW CAMERA UN-C3 200-HV34 BK-18-TXL 33 33
H1
32 32
563-9823 490-0571 34 34 BR+ 33 33
35 35 BR- CBL-UN1:1826-UN2 WH-BU-20 34 34 ETH BR5 2 +
ETHERNET+ 1 CBL-UN2:1824-UN2 WH-BU-20 36 36 ETH TX+ CBL-UN1:1827-UN1 BU-20 35 35 ETH BR5 2 -
ETHERNET- 2 CBL-UN2:1825-UN1 BU-20 37 37 ETH TX- 36 36
38 38 ETH RX+ 37 37
39 39 ETH RX- 38 38
40 40 39 39
12V+ POWER 1 T801-HV20 PU-20-TXL 41 41 ETH TX+ 40 40
GROUND 2 200-HV6 BK-20-TXL 42 42 ETH TX- 41 41
43 43 ETH RX+ 42 42
HV-C8 44 44 ETH RX- 43 43
490-0578 133-HV15 RD-18-TXL 44 44
160-HV39 PU-18-TXL UN-C1
235-HV51 BK-18-TXL 483-2762
235-HV50 BK-18-TXL
C592-HV35 WH-20-TXL 1 1 ETH TX+
F711-HV26 YL-18-TXL 2 2 ETH TX- 1 ETH TX+
F712-HV33 GN-18-TXL 3 3 ETH RX+ 2 ETH TX-
K960-HV31 YL-18-TXL 4 4 ETH RX- 3 ETH RX+
235-HV51 BK-18-TXL K961-HV32 GN-18-TXL 5 5 4 ETH RX- F-C1
235-HV50 BK-18-TXL 6 6 5 444-7595
200-HV34 BK-18-TXL CBL-UM2:1820-UM2 WH-BU-20 7 7 6
SWITCHED UN-SWITCHED
CBL-UM2:1821-UM1 BU-20 8 8 7 1
235-HV51 BK-18-TXL CBL-UM1:1822-UM2 WH-BU-20 9 9 DTR WAKEUP 8 2
L2 L1
(8) GROUND 235
235-HV50 BK-18-TXL CBL-UM1:1823-UM1 BU-20 10 10 9 DTR WAKEUP 3
200-HV4 BK-16-GXL CBL-UN2:1824-UN2 WH-BU-20 11 11 10 4
200-HV5 BK-16-GXL CBL-UN2:1825-UN1 BU-20 12 12 11 5
F1-R F1 F21 F1-L
13 13 12 6
F2-R F2 F22 F2-L
200-HV34 BK-18-TXL 14 14 13 7
F3-R F3 F23 F3-L
200-HV5 BK-16-GXL 15 15 14 8
F4-R F4 F24 F4-L
200-HV4 BK-16-GXL 16 16 15 9
16 TO MATING CONNECTOR F5-R F5 F25 F5-L
17 17 10
F6-R F6 F26 F6-L
CBL-UN2:1825-UN1 BU-20 18 18 ETH BR5- 17 11

CONN 3
F7-R F7 F27 F7-L

H1
CBL-UN2:1824-UN2 WH-BU-20 19 19 ETH BR5+ 18 12
F8 F28 F8-L
F8-R
(7) GROUND 200
CBL-UN1:1826-UN2 WH-BU-20 20 20 19 13
CBL-UN1:1827-UN1 BU-20 21 21 20 CONNECTS TO C-C1 14
F9-R F9 F29 F9-L
F10-R F10-L
22 22 21 LOC E-3 15
F10 F30

F11-R F11 F31 F11-L


23 23 22 16
F12-R F12 F32 F12-L
24 24 23 17
F13-R F13 F33 F13-L
25 25 24 18
F14-R F14 F34
5
F14-L
133-F106 RD-14-TXL
26 26 25 19
F15-R F15 F35 F15-L
27 27 26 20 160-WV1 PU-18-TXL F16-R
10
F16 F36 F16-L
28 28 27 21
F17-R F17 F37 F17-L
29 29 28 22
F18-R F18 F38 F18-L
30 30 29 23
F19-R F19 F39 F19-L
31 31 30 24
F20-R F20 F40 F20-L
32 32 31 25
33 33 32 26 R1 R6
CBL-UN1:1826-UN2 WH-BU-20 34 34 ETH BR1+ 33 27 R1-5 R6-5
CBL-UN1:1827-UN1 BU-20 35 35 ETH BR1- 34 28 R1-4 R6-4
36 36 ETH TX+ 35 29 R1-3 R6-3
37 37 ETH TX- 36 30 R1-2 R6-2
38 38 ETH RX+ 37 31 R1-1 R6-1
39 39 ETH RX- 38 32
40 40 39 33 160-WV1 PU-18-TXL R2 R7
41 41 40 34
R2-5 R7-5
42 42 41 35
R2-4 R7-4
(10) CAN (J1939) DATA LINK HV-C16 43 43 42 36 R2-3 R7-3
324-5678 273-3288 44 44 43 37
R2-2 R7-2
44 38
R2-1 R7-1
1 F711-HV23 YL-18-GXL HV-C3 39
2 F712-HV25 GN-18-GXL 483-2763 40 R3 R8
41 R3-5 R8-5
K961-HV32 GN-18-TXL 1 1 J1939 CAN LOW 42 R3-4 R8-4
HV-C17 K960-HV31 YL-18-TXL 2 2 J1939 CAN HIGH 1 43
R3-3 R8-3
CONN 1 240-7874 3 3 2 44 R3-2 R8-2
F712-HV33 GN-18-TXL 4 4 J1939 CAN LOW 3 45 R3-1 R8-1
MATING CONNECTOR : 1 F711-HV22 YL-18-GXL F711-HV23 YL-18-GXL F711-HV26 YL-18-TXL 5 5 J1939 CAN HIGH 4 J1939 CAN LOW 46
LOCAL CAN DATA LINK TO CHASSIS 2 F712-HV24 GN-18-GXL F711-HV22 YL-18-GXL 6 6 5 J1939 CAN HIGH 47 R4 R9
F711-HV26 YL-18-TXL 160-HV39 PU-18-TXL 7 7 KEY SWITCH ON 6 48
R4-5 R9-5
8 8 7 KEY SWITCH ON 49
R4-4 R9-4
F712-HV25 GN-18-GXL 9 9 8 50
R4-3 R9-3
(11) LOCAL CAN DATA LINK FOR DISPLAY HV-C11 F712-HV24 GN-18-GXL 10 10 9 51
R4-2 R9-2
324-5678 273-3288 11 11 10 52
R4-1 R9-1
F712-HV33 GN-18-TXL 12 12 11 53
1 K960-HV28 YL-18-GXL K960-HV28 YL-18-GXL 13 13 12 54 R5 R10
2 K961-HV30 GN-18-GXL K960-HV27 YL-18-GXL 14 14 13 55 R5-5 R10-5
15 15 14 56 R5-4 R10-4
K960-HV31 YL-18-TXL 15
24 Page, (Dimensions: 34 inches x 28 inches)

16 16 57 R5-3 R10-3
K961-HV30 GN-18-GXL 17 17 16 58 133-F106 RD-14-TXL R5-2 R10-2
HV-C15 K961-HV29 GN-18-GXL 18 18 17 59 R5-1 R10-1
CONN 2 240-7874 K961-HV32 GN-18-TXL 19
20
19
20
18
19
60
61 (12) FUSE BASE
MATING CONNECTOR : 1 K960-HV27 YL-18-GXL 21 21 20 62 238-2319
LOCAL CAN DATA LINK TO CHASSIS 2 K961-HV29 GN-18-GXL 22 22 21
23 23 22
24 24 23
25 25 24
26 26 25
27 27 26
28 28 27
29 29 28
30 30 29
C592-HV35 WH-20-TXL 31 31 RELAY WAKEUP 30
32 32 31
33 33 32
34 34 33
M0165635

35 35 34
133-HV15 RD-18-TXL 36 36 BTRY+ 35
235-HV50 BK-18-TXL 37 37 BTRY- 36 BTRY+
38 38 37 BTRY-
39 39 ETH TX+ 38
40 40 ETH TX- 39 ETH TX+ SWITCHED POWER FUSE FUNCTION RATING CID-CLR FUSE RATING PART NO.
41 41 ETH RX+ 40 ETH TX- F16 PERSONNEL DETECTION 10 160-PU 5A 141-2759
42 42 ETH RX- 41 ETH RX+ 10A 113-8490
43 43 42 ETH RX- TOOL 170-6888
44 44 43
44
UNSWITCHED POWER FUSE FUNCTION RATING CID-CLR
F34 A6N2 5 133-RD
235-HV51 BK-18-TXL

PERSONNEL DETECTION/ CHASSIS SIDE CAB SIDE

REF DES PART NO. CHG LVL DESCRIPTION


CALLOUT FORMAT IF APPLICABLE HV 623-5968 0 HARNESS AS-CHAS (PERSONNEL DETECTION)
HV 627-4225 0 HARNESS AS-CHAS (PEOPLE DETECTION)
HV 631-7068 0 HARNESS AS-CHAS (PEOPLE DETECTION)
Callout Number Component
(Machine Location from (52) VALVE GP - CONTROL Name HV 633-3565 0 HARNESS AS-CHAS (PEOPLE DETECTION)
Component Locations Table) UM 613-0315 0 HARNESS AS-CAMR (REAR SIDE / RIGHT SIDE)
138-1234 Part Number UM 627-4226 0 HARNESS AS-CAMR (REAR SIDE / RIGHT SIDE)
UM 631-7076 0 HARNESS AS-CAMR (REAR SIDE / RIGHT SIDE)

WIRE GROUP COLOR DESCRIPTIONS


UM 633-3568 0 HARNESS AS-CAMR (REAR SIDE / RIGHT SIDE)
SYMBOL DESCRIPTION ABBREV COLOR UN 613-0314 0 HARNESS AS-CAMR (LEFT SIDE)
UN 627-4228 0 HARNESS AS-CAMR (LEFT SIDE)
GROUND CIRCUIT RD RED UN 631-7079 0 HARNESS AS-CAMR (LEFT SIDE)
CIRCUIT CONNECTED
UN 633-3567 0 HARNESS AS-CAMR (LEFT SIDE)
WIRES THAT HAVE SYSTEM VOLTAGE WHEN THE KEY SWITCH IS OFF WV 609-5413 0 WIRE AS-CAB (PERSONNEL DETECTION)
WH WHITE
WIRES THAT HAVE SYSTEM VOLTAGE WHEN THE KEY SWITCH IS ON CIRCUIT NOT CONNECTED
VOLTAGE CONVERTER OUTPUT CIRCUIT OR ORANGE
ELECTRICAL CONNECTION TO
J1939 CAN DATA LINK MACHINE STRUCTURE
YL YELLOW
J1939 CAN DATA LINK FOR DISPLAY (LOCAL) INTERNAL ELECTRICAL CONNECTION
TO SURFACE OF COMPONENT PK PINK
ETHERNET
CONNECTOR BK BLACK
OTHER COLOR DESCRIPTIONS GY GRAY
H# CIRCUIT GROUPING DESIGNATION
HIGHWAYS
PU PURPLE
ATCH WIRE, CABLE, COMPONENT
BR BROWN
/ SPLICE
GN GREEN
BLADE, SPADE, RING OR SCREW
TERMINAL BU BLUE

Do not operate or work on this product unless you have


read and understood the instruction and warnings in the
relevant Operation and Maintenance Manuals and
relevant service literature. Failure to follow the instruc-
tions or heed the warnings could result in injury or
death. Proper care is your responsibility.

THIS SCHEMATIC IS FOR THE 320 AND 323 EXCAVATOR PEOPLE DETECTION KIT
ELECTRICAL SYSTEM
MEDIA NUMBER: M0165635
SCHEMATIC PART NUMBER: 608-0201, CHANGE: 02, VERSION: HE
Components are shown installed on a fully operable machine with the key and engine off.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.
CAB REAR VIEW
VIEW ALL CALLOUTS

CONN 2

CONN 3

6
5 11
CHASSIS REAR RIGHT VIEW
VIEW ALL CALLOUTS

8 CONN 1
10
MACHINE - LEFT VIEW
VIEW ALL CALLOUTS

12

You might also like