How to calculate anoxic tank in MBBR STP with retention


time calculation?
MBBR (Moving Bed Biofilm Reactor) based Sewage Treatment Plants (STP) have become popular due to their efficiency and
low operational and maintenance costs. One of the critical components of an MBBR based STP is the anoxic tank.

Let’s have an understanding on how to calculate the size of anoxic tank in MBBR based STP.

What is an Anoxic Tank?


Anoxic tanks are an essential component of MBBR based STP. These tanks provide an environment where bacteria can break
down the nitrogenous compounds in sewage by converting nitrate to nitrogen gas under anaerobic conditions.

Factors Affecting Anoxic Tank Size:


The size of the anoxic tank in MBBR based STP depends on various factors such as:

· Sewage flow rate
Chat with us×

· Nitrogenous load
https://www.netsolwater.com/how-to-calculate-anoxic-tank-in-mbbr-based-stp-with-retention-time-calculation-in-details.php?blog=4466 1/5
5/2/24, 1:38 PM How to calculate anoxic tank in MBBR STP with retention time calculation

· Required effluent quality

· Hydraulic Retention Time (HRT)


HOME ABOUT US PRODUCTS KNOWLEDGE CENTER CLIENTS RESOURCES CONTACT GET A QUOTE!
· Mixed Liquor Suspended Solids (MLSS)

Calculating Anoxic Tank Size:


The anoxic tank size can be calculated using the following formula:

Anoxic Tank Volume = (F × V × θ) / (R × (SNOx-SNit))

Where,
F = Nitrogenous Load (kg N/day)
V = Sewage Flow Rate (m3/day)
θ = Anoxic Tank Retention Time (days)
R = Nitrate Removal Efficiency
SNOx = Nitrate Concentration in influent (mg/L)
SNit = Nitrate Concentration in effluent (mg/L)

Step-by-Step Calculation Process:


Let's consider an example to calculate the anoxic tank size for an MBBR based STP with the following parameters:

· Sewage flow rate = 100 m3/day

· Nitrogenous Load = 100 kg N/day

· Anoxic Tank Retention Time = 4 hours

· Nitrate Removal Efficiency = 90%

· Nitrate Concentration in influent = 50 mg/L

· Nitrate Concentration in effluent = 5 mg/L

Step 1:
Calculate the Required Anoxic Tank Volume.
Anoxic Tank Volume = (F × V × θ) / (R × (SNOx-SNit))
Anoxic Tank Volume = (100 × 100 × 4) / (0.9 × (50-5)) = 988.89 m3

Step 2:
Determine the Dimensions of the Anoxic Tank.
Once the anoxic tank volume is calculated, the dimensions of the tank can be determined. The tank should have a depth of at
least 3 meters to ensure proper mixing and to avoid dead zones.

Step 3:
Calculate the Anoxic Tank Retention Time.
The retention time of the anoxic tank is the time taken for the sewage to pass through the tank.
It can be calculated using the formula:

Anoxic Tank Retention Time = Anoxic Tank Volume / Sewage Flow Rate Anoxic Tank

Retention Time = 988.89 / 100 = 9.89 hours

Step 4:
Verify Nitrate Concentration in Effluent.
Chat with us×
The nitrate concentration in the effluent should be verified to ensure that it meets the required effluent quality. If the concentration
is higher than the required limit, the anoxic tank size should be increased.
https://www.netsolwater.com/how-to-calculate-anoxic-tank-in-mbbr-based-stp-with-retention-time-calculation-in-details.php?blog=4466 2/5
5/2/24, 1:38 PM How to calculate anoxic tank in MBBR STP with retention time calculation

Conclusion.

The calculation of the anoxic tank size is an essential aspect of designing an MBBR based STP. The anoxic tank size depends on
HOME factors
various ABOUT
suchUS PRODUCTS
as sewage KNOWLEDGE CENTER
flow rate, nitrogenous CLIENTS
load, required RESOURCES
effluent quality, and designCONTACT GET A QUOTE!
parameters such as HRT and
MLSS. The formula to calculate the anoxic tank size involves nitrogenous load, sewage flow rate, anoxic tank retention

Leading manufacturer of sewage treatment plants in India.


Netsol Water is the leading manufacturer, supplier, and exporter of a quality selection of water treatment, and wastewater
treatment products in India, by using advanced sewage treatment methods.
RO plants, water softeners, ETPs, STPs, DM plants, AMC, O&M, Ultra filtration, UV, Ozonation, ZLD plants, Anoxic tanks, and
other goods and services are available from us. We also provide services to businesses in sectors including automotive,
pharmaceutical, textile, pulp & paper, beverages, refineries, schools, hospitals, office buildings, and hotels, among others.
Call us at +91 9650608473 or email at enquiry@netsolwater.com for further information.

Enquire Now

Your Name

Phone

Email

Message

SUBMIT NOW

Related Blog List

 How much Water a Water Softener treat in the Tea making industry

 Advanced Methods of Leachate Treatment

 the role of commercial RO plants in achieving water independence

 What is multiple-effect distillation

 How to produce methane gas out of treated waste waters

 View All Blogs


Chat with us×

https://www.netsolwater.com/how-to-calculate-anoxic-tank-in-mbbr-based-stp-with-retention-time-calculation-in-details.php?blog=4466 3/5
5/2/24, 1:38 PM How to calculate anoxic tank in MBBR STP with retention time calculation

Popular Products

HOME ABOUT US PRODUCTS KNOWLEDGE CENTER CLIENTS RESOURCES CONTACT GET A QUOTE!
Sewage Treatment Plant Sewage Treatment Plant Manufacturer Effluent Treatment Plant

Effluent Treatment Plant Manufacturer Industrial RO Plant Commercial RO Plant Manufacturer

Water Treatment Solutions

Email address to subscribe SUBSCRIBE      

Netsol Water is a water and wastewater treatment company in Delhi NCR, India that designs, and manufactures ace machines to
save the earth and its resources, especially water.
About Us

Why Choose Us
Disclaimer

Terms and conditions

Sitemap
Contact us

Career
Resources

News

Knowledge Center
Gallery
Manufacturing: Plot No.- 164,Udyog Vihar Ext-II, Ecotech-II,Greater Noida, Uttar Pradesh, India
Contact us
Chat with us×

J-176, SECTOR-41, NOIDA, Gautam Buddha Nagar, Uttar Pradesh,India, 201301(Reg.)


https://www.netsolwater.com/how-to-calculate-anoxic-tank-in-mbbr-based-stp-with-retention-time-calculation-in-details.php?blog=4466 4/5
5/2/24, 1:38 PM How to calculate anoxic tank in MBBR STP with retention time calculation

Call Us: +91 9650608473/9650795306

Email: info@netsolwater.com

HOME ABOUT US PRODUCTS KNOWLEDGE CENTER CLIENTS RESOURCES CONTACT GET A QUOTE!

COPYRIGHT © 2024 NETSOL WATER SOLUTIONS PVT. LTD. - WATER TREATMENT COMPANY DELHI/NCR. ALL RIGHTS RESERVED.

Chat with us×

https://www.netsolwater.com/how-to-calculate-anoxic-tank-in-mbbr-based-stp-with-retention-time-calculation-in-details.php?blog=4466 5/5

You might also like