Let’s have an understanding on how to calculate the size of anoxic tank in MBBR based STP.
· Nitrogenous load
https://www.netsolwater.com/how-to-calculate-anoxic-tank-in-mbbr-based-stp-with-retention-time-calculation-in-details.php?blog=4466 1/5
5/2/24, 1:38 PM How to calculate anoxic tank in MBBR STP with retention time calculation
Where,
F = Nitrogenous Load (kg N/day)
V = Sewage Flow Rate (m3/day)
θ = Anoxic Tank Retention Time (days)
R = Nitrate Removal Efficiency
SNOx = Nitrate Concentration in influent (mg/L)
SNit = Nitrate Concentration in effluent (mg/L)
Step 1:
Calculate the Required Anoxic Tank Volume.
Anoxic Tank Volume = (F × V × θ) / (R × (SNOx-SNit))
Anoxic Tank Volume = (100 × 100 × 4) / (0.9 × (50-5)) = 988.89 m3
Step 2:
Determine the Dimensions of the Anoxic Tank.
Once the anoxic tank volume is calculated, the dimensions of the tank can be determined. The tank should have a depth of at
least 3 meters to ensure proper mixing and to avoid dead zones.
Step 3:
Calculate the Anoxic Tank Retention Time.
The retention time of the anoxic tank is the time taken for the sewage to pass through the tank.
It can be calculated using the formula:
Anoxic Tank Retention Time = Anoxic Tank Volume / Sewage Flow Rate Anoxic Tank
Step 4:
Verify Nitrate Concentration in Effluent.
Chat with us×
The nitrate concentration in the effluent should be verified to ensure that it meets the required effluent quality. If the concentration
is higher than the required limit, the anoxic tank size should be increased.
https://www.netsolwater.com/how-to-calculate-anoxic-tank-in-mbbr-based-stp-with-retention-time-calculation-in-details.php?blog=4466 2/5
5/2/24, 1:38 PM How to calculate anoxic tank in MBBR STP with retention time calculation
Conclusion.
The calculation of the anoxic tank size is an essential aspect of designing an MBBR based STP. The anoxic tank size depends on
HOME factors
various ABOUT
suchUS PRODUCTS
as sewage KNOWLEDGE CENTER
flow rate, nitrogenous CLIENTS
load, required RESOURCES
effluent quality, and designCONTACT GET A QUOTE!
parameters such as HRT and
MLSS. The formula to calculate the anoxic tank size involves nitrogenous load, sewage flow rate, anoxic tank retention
Enquire Now
Your Name
Phone
Message
SUBMIT NOW
How much Water a Water Softener treat in the Tea making industry
https://www.netsolwater.com/how-to-calculate-anoxic-tank-in-mbbr-based-stp-with-retention-time-calculation-in-details.php?blog=4466 3/5
5/2/24, 1:38 PM How to calculate anoxic tank in MBBR STP with retention time calculation
Popular Products
HOME ABOUT US PRODUCTS KNOWLEDGE CENTER CLIENTS RESOURCES CONTACT GET A QUOTE!
Sewage Treatment Plant Sewage Treatment Plant Manufacturer Effluent Treatment Plant
Netsol Water is a water and wastewater treatment company in Delhi NCR, India that designs, and manufactures ace machines to
save the earth and its resources, especially water.
About Us
Why Choose Us
Disclaimer
Sitemap
Contact us
Career
Resources
News
Knowledge Center
Gallery
Manufacturing: Plot No.- 164,Udyog Vihar Ext-II, Ecotech-II,Greater Noida, Uttar Pradesh, India
Contact us
Chat with us×
Email: info@netsolwater.com
HOME ABOUT US PRODUCTS KNOWLEDGE CENTER CLIENTS RESOURCES CONTACT GET A QUOTE!
COPYRIGHT © 2024 NETSOL WATER SOLUTIONS PVT. LTD. - WATER TREATMENT COMPANY DELHI/NCR. ALL RIGHTS RESERVED.
https://www.netsolwater.com/how-to-calculate-anoxic-tank-in-mbbr-based-stp-with-retention-time-calculation-in-details.php?blog=4466 5/5