V5 Interface Administration
Contents
1 Overview: V5 Interfaces in EWSD 3
1.1 Specifications 4
1.1 Realization of V5.1 Interface in EWSD 6
1.2 Realization of V5.2 Interface in EWSD 10
2 V5 Protocols between EWSD and AN 21
2.1 Overview of Protocols for V5.1 and V5.2 22
2.2 Application of the Protocols for a Call Setup 24
2.3 V5.2: Protection Groups for Vital and Non-vital Protocols 26
2.4 Communication Paths V5CMPATH 28
3 Administration of V5 Interface 31
3.1 Configuration Example V5.2 Interface 32
3.2 Configuration Example V5.1 Interface 42
3.3 Special Aspects of V5 Subscriber Administration 48
4 Exercise 51
5 Solution 55
SN2073EU01SN_0002
1
© 2002 Siemens AG
Siemens V5 Interface Administration
2 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
SN2073EU01SN_0002
3
© 2002 Siemens AG
Siemens V5 Interface Administration
1.1 Specifications
With the V5 Interfaces the protocol requirements for the interface between an Access
Network (AN) and the Local Exchange (LE) has been specified for various access
types.
Using the V5.1 or V5.2 interface, it is possible to link to the network node hardware
produced by different manufacturers used for the connection of subscriber lines. The
hardware for connecting subscriber lines is described as the access network (AN).
Both interfaces have a flexible (provisioned) allocation of the information channel
(bearer channel).
The V5.1IF has no concentration capability within the AN and uses only one 2 Mbit/s
link.
The V5.2IF can be used parallel with the V5.1IF and is inherently designed to
concentrate user channels with a dedicated protocol. V5.2IF may use up to 16
(EWSD: 8) 2 Mbit/s links on one interface.
Fig. 1
4 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
Fig. 2
SN2073EU01SN_0002
5
© 2002 Siemens AG
Siemens V5 Interface Administration
DSS1
signaling
TE
AN
1 ... 14 15 16 17.. 31
TE LE
X.25
data in D
PSTN
Analog
TE
V5.1
Fig. 3
6 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
V5 INTERFACE
V5LINK(1)
V5TS(1)............V5TS(31)
used as
BCH or CCH
DEFAULT value for DEFAULT value for V5TS 16
V5TS 1-15 and 17-31
(may be defined with MOD V5TS
for TS 15 / 31)
used as
V5CMCHAN
each V5CMCHAN gets as fixed characteristics:
- a V5CHANID
- list of transported protocols
(allocation of a protocol to a V5CHANID is
done through the object V5CMPATH)
Fig. 4
SN2073EU01SN_0002
7
© 2002 Siemens AG
Siemens V5 Interface Administration
In comparison to the SLMX in DLUA or DLUB the DLUV brings advantages in cost
and space requirement. It consists of a single module called DLUV which permits the
connection of up to 10 V5.1 interfaces remotely via the module DIUD on the LTG
side or locally via the module LDIB on the LTG side.
The module DLUV is the combination of the central modules of the DLUB: DLUC
(Control Unit), DIU/LDI (Interface Unit), GCG (Clock Generator Unit), BD (Bus
Distribution Unit), ALEX (Interface to external alarms), DCC (Direct current
Converter) and 5 SLMX (Subscriber Line Module X).
For APS-version >11 the DLUV can be created with the new shelf type V. Only the
ALEX function (position 0-11) has then to be configured separately. Packet data
access is given with MOD DLUMOD for the SLMX ports. The virtual SLMX modules
are located in the positions 1-0 till 1-4.
Up to 16 DLUV modules can be plugged into the new frame F:DLUV(A) with the
ordering code S30804-B2730-X. Up to 4 DLUVs can also be plugged into the
F:DLU(G). In this case only the power connection is used and no other connection to
the DLU system exists.
Up to 4800 analog / 2400 digital subscribers are connected to the frame F:DLUV(A).
The new frame is built in two rows employing the SIPAC system. The power
connection is made over the rear connectors. 4 DLUV modules are connected with 1
cable to the fuse panel.
Like a DLUB a DLUV can be connected over a local DLU Interface (LDI) or in case of
remote operation over PCM30 links (120 Ohm symmetrical or 75 Ohm coaxial). The
two different operation modes are distinguished by a bridge connection in the LDI
connectors.
TIP
Each DLUV is connected to an LTG pair by in total 60 (and never 120) speech
channels. These 60 channels are either transported by 2 fully used 2 Mb/s links or by
2 only to 50% used 4 Mb/s links.
8 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
SLMX
DLUC
SLMX
DIU:DLU
DLUV SLMX
LDID
SLMX
BD
SLMX
Fig. 5
SN2073EU01SN_0002
9
© 2002 Siemens AG
Siemens V5 Interface Administration
Hardware requirements
CP: CP113, CP113C, CP113CR
MB: MB(B) HW, FW from version V10 or higher
LTG: LTG M/N in B function with 32MB GP memory capacity with high
performance SILC as M:PHMA on the special mounting position of the LTG
M/N (or integrated SILC). Mixed operation of V5.2 interfaces with DLU or PA
on the same LTG M/N is not possible.
10 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
Analog
Analog
subs.
LTG-x
LTG-x SN
SN
subs.
(M
(M or
or N)
N)
Up to 4
Analog
Analog V5LINK
subs.
subs.
M:PHMA
ISDN
ISDN
BA
BA
ISDN
ISDN
BA
BA AN LTG-y
LTG-y
(M
(M or
or N)
N)
Up to 4
V5.1
V5.1 V5LINK
V5.2 IF M:PHMA
transparent
ISDN
ISDN
PA
PA
LTGB
LTGB
SN2073EU01SN_0002
11
© 2002 Siemens AG
Siemens V5 Interface Administration
AN1
LTG
LTG
AN1
AN2
LTG AN3
AN4
AN2
AN1
LTG LTG
AN1
LTG LTG
LTG LTG
AN1
AN2
AN3
Fig. 7
12 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
LE
V5.2
LTGM/N 1
SIEM ENS
NIXDORF
HICOM LTGM/N 2
ISDN PA LTG
SN2073EU01SN_0002
13
© 2002 Siemens AG
Siemens V5 Interface Administration
14 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
V5 INTERFACE
V5 LINK(1)...................................V5LINK(8)
V5TS(1)............................ V5TS(31)
used as
BCH or CCH
DEFAULT value must be defined with MOD
V5TS (max. 3 per LINK on TS
16/15/31, max. 8 per interface)
used as
Fig. 9
SN2073EU01SN_0002
15
© 2002 Siemens AG
Siemens V5 Interface Administration
Rules for the selection of LTGs for the usage of the Report Mirror function
(only important for EWSD Classic)
As is known, the (max.) 63 LTGs of a TSG are connected to SN0 and the SN1
always via two 8Mbit/s routes (SDC). The message channels (timeslots 0) with the
same operational conditions (ACT or STB) are distributed uniformly between both
switching networks for reasons of security in case of failure.
When selecting the two LTGs of an V5.2 interface, make sure that the message
channels (MCH) of both LTGs all have the same operating mode for each MBU:LTG
(ACT or STB). Which LTGs of a TSG fulfill this criterion and therefore form a "V5.2
LTG group", can be derived from the following list. Both LTGs of a V5.2 pair must be
selected from the same "V5.2 LTG group" within a TSG.
"V5.2 LTG group 1":
1, 3, 4, 6, 9, 11, 12, 14, 17, 19, 20, 22, 25, 27, 28, 30, 33, 35, 36, 38, 41, 43, 44, 46,
49, 51, 52, 54, 57, 59, 60, 62
With two LTGs from the same group, it is guaranteed that MBU:LTG REPORT
MIRROR can be used for REPORTs between these LTGs.
This prevents the many REPORTs between the two LTGs of an V5.2 interface
from burdening the interface to CP (IOP:MB).
16 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
CP
63 63
AN
0 31
DMBU
MBUL MBUL
with
mirror
function
DMBU =
DMBU = MBU number
MBU number
IOP:MB IOP:MB
CP
(IOCP/
CMY)
SN2073EU01SN_0002
17
© 2002 Siemens AG
Siemens V5 Interface Administration
18 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
D P G G
I H S P
U M M L
A S
SILC integrated on GPLS
module on the free
* new HW
LTGM plug-in position
* special V5.2 FW
Fig. 12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN2073EU01SN_0002
19
© 2002 Siemens AG
Siemens V5 Interface Administration
20 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
SN2073EU01SN_0002
21
© 2002 Siemens AG
Siemens V5 Interface Administration
Carried on Carried on
Protocol type a separate a separate
(C-Path) Purpose Layer 3 per ... Layer 2 per ...
· timeslot audit
Protection *) **) · protection sw itching of 1 comm on Layer 3 2 separate Layer
com munication channels (C channels) per 2 per
V5 interface V5 interface
22 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
15 16 31 Timeslot
V5.2
AN LE
PROTOCOL
Protection Protocol
ISDN-P Data
Port Control Protocol
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN2073EU01SN_0002
23
© 2002 Siemens AG
Siemens V5 Interface Administration
TIP
In case of the V5.1 interface the BCC protocol is not used because for each
subscriber is fixed timeslot assignment is stored in the database of EWSD and AN.
24 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
SIEMENS SIEMENS
V5LINK
A-sub.
(ISDN- AN
TE) V5
ISDN-
BA CMCHAN
BCC Protocol:
LTG informs the AN which BCH
timeslot should be used
Result: transparent layer 1 between TE and GS of the LTG for the B-channel
Fig. 15
SN2073EU01SN_0002
25
© 2002 Siemens AG
Siemens V5 Interface Administration
26 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
Assignment
CCH reserved for: using
MOD V5TS
Control ISDN - p
BCC ISDN-Ds
Protection
SN2073EU01SN_0002
27
© 2002 Siemens AG
Siemens V5 Interface Administration
Protection protocol
This protocol is automatically set up by the system on both CCHs of protection
group 1. This way, the AN or the EWSD receives the same switchover instructions
twice during the failure of a CMCHAN of protection group 2, the instruction received
second is ignored.
The two communication paths of the protection protocol both get the V5PATHID 13.
The remaining V5PATHID (0-12) can be made available for the other protocols when
creating the max. 12 communication paths.
TIP
For V5.1 interface the vital protocols are automatically assigned to the CCH on TS16.
The PSTN protocol has max. 1 CMPATH (on TS16, or 15 or 31) and the ISDN
protocol has max 3 CMPATH (one on each CCH).
28 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
CMPATH Protection
Switching
LINK CONTROL
BCC
PSTN
ISDN Ds
(group 1)
ISDN Ds
(group 4)
ISDN p-data
(group 1)
ISDN p-data
(group 4)
SN2073EU01SN_0002
29
© 2002 Siemens AG
Siemens V5 Interface Administration
30 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
3 Administration of V5 Interface
SN2073EU01SN_0002
31
© 2002 Siemens AG
Siemens V5 Interface Administration
Fig. 19
32 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
LTG 0-45
V5LINKID1
2
V5LINKID3
3
AN
LTG 0-55
V5LINKID2
0
V5LINKID4
1
2
V5IF=6054
3
Fig. 20
SN2073EU01SN_0002
33
© 2002 Siemens AG
Siemens V5 Interface Administration
Fig. 21
34 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
Fig. 22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN2073EU01SN_0002
35
© 2002 Siemens AG
Siemens V5 Interface Administration
Fig. 23
36 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
Fig. 24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN2073EU01SN_0002
37
© 2002 Siemens AG
Siemens V5 Interface Administration
TIP
Also the logical communication channels CMCHAN must be created on the
same timeslots with the same protocols CMPATH and the V5CHANID must be
the same in the AN and the EWSD.
Furthermore, it is important that the standby communication channels (CCH)
reserved for protection switching are also set up on the same timeslots in the
EWSD and the AN.
38 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
l V5IFID
l V5LINKID
l V5CHANID
l PROVAR
l V5 ACCID
Fig. 25
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN2073EU01SN_0002
39
© 2002 Siemens AG
Siemens V5 Interface Administration
TIP
The activation of the V5PORTs must be performed in both the AN and the EWSD
40 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
The DIU is configured together with the V5LINK and can not be configured
separately
Fig. 26
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN2073EU01SN_0002
41
© 2002 Siemens AG
Siemens V5 Interface Administration
DLUV 10
28 Data channels
(Bearer Channel) virtual
SLMX 0
virtual
SLMX 1
AN
31 30 17 16 15 2 1 virtual
SLMX 2
virtual
SLMX 3
3control virtual
channels SLMX 4
(C-Channel)
Fig. 27
42 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
CR DLU:
DLU = 10,
SHELF = V; Creating a virtual DLU (DLUV)
DLUC0= < LTG – DIU for first of the two 2Mb/s or 4 Mb/s links >
DLUC1= < LTG – DIU for second of the two 2Mb/s or 4 Mb/s links >
CR DLUMOD:
DLU = 10,
MOD = 1-2, Creating the third virtual SLMX
SLMXID = 2,
TYPE = SLMX;
Fig. 28
CR V5IF:
V5IF = 6000, V5.1 interface
V5IFID = 4711, V5.1 interface identification
IFTYPE = V51, Interface type: V5.1
PROVAR = 0; Provisioning variant
CR V5LINK:
V5IF = 6000, V5.1 interface
V5LINK = 10-2-0; 10 = DLU number
2 = SLMX-ID
0 = PCM system at the virt. SLMX
Fig. 29
SN2073EU01SN_0002
43
© 2002 Siemens AG
Siemens V5 Interface Administration
ISDN
Packet Data
TE
AN
... 13 14 15 16 17 ... 31
ISDN-
DSign.
LE
PSTN Vital
Analog Protocols
TE
V5.1
Fig. 30
44 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
MOD V5TS:
V5IF = 6000, V5.1 interface
V5TS = 15, Timeslot 15
USAGE = CCH; Used as a C channel
CR V5CMCHAN:
V5IF = 6000, V5.1 interface
V5CHANID = 1, TS16 autom. has V5CHANID = 0
V5TS = 15;
MOD V5TS:
V5IF = 6000, V5.1 interface
V5TS = 31, Timeslot 31
USAGE = CCH; Used as a C channel
CR V5CMCHAN:
V5IF = 6000, V5.1 interface
V5CHANID = 2,
V5TS = 31;
Fig. 31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN2073EU01SN_0002
45
© 2002 Siemens AG
Siemens V5 Interface Administration
TIP
Timeslot 16 automatically contains the protocols which are absolutely necessary for
the operation of the V5 interface (the vital protocols).
Fig. 32
ISDN
Packet Data
TE
AN
ISDN-
... 13 14 15 16 17 ... 31
DSign.
LE
PSTN Vital
Analog Protocols
TE
V5.1
Fig. 33
46 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
CR V5CMPATH:
V5IF = 6000, V5.1 interface
V5CHANID = 0, refers indirectly to the timeslot 16
V5PATHID = 1, ID for the following protocol path
PATHTYPE = PSTN;
Fig. 34
CR V5CMPATH:
V5IF = 6000, V5.1 interface
V5CHANID = 1, refers indirectly to the timeslot 15
V5PATHID = 2, ID for the following protocol path
PATHTYPE = ISDN,
ISDNTYPE = DS;
CR V5CMPATH:
V5IF = 6000, V5.1 interface
V5CHANID = 2, refers indirectly to the timeslot 31
V5PATHID = 3, ID for the following protocol path
PATHTYPE = ISDN,
ISDNTYPE = P;
Fig. 35
SN2073EU01SN_0002
47
© 2002 Siemens AG
Siemens V5 Interface Administration
l V5ACCID
The access ID is used in the signaling protocol between AN and EWSD for
identification of V5 subscribers. Therefore the ACCID for every subscriber must
have the same value in AN and in the EWSD. The ACCID is allocated in EWSD
with the MML command CRSUB using the parameters COSDAT=V5ACCID-
<0....32767> (for ISDN subscribers <0...8175>).
l Preparation (creating the LAC, DN and CPT)
CR DN: LAC=0804, DN=552200&&552299;
CR CPT: CODE=5522, LAC=0804, TRATYP=CPTDN;
l Creating subscribers
Creating subscribers, PBX and PBXLNs at the V5.2 interface V5IF=6054:
CR SUB:
LAC=0804,DN=552202,CAT=IBA,SERV=TEL3K,
EQN=6054-0-0-2, COSDAT=V5ACCID-2&V5DSDAT-4;
TIP
Overview of the use of protocol paths according at V5IF=6054:
1 PSTN PATH (V5PATHID=3) for analog subscribers
1 DS PATH (V5PATHID=4) for ISDN subscribers
1 P PATH (V5PATHID=5) for D channel packet network access
V5DSDAT must always be created, if more than one DS path exists at the V5
interface.
48 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
&
V5DSDAT - PATHid & V5DSDAT- PATHid
Only necessary if V5IF has more than one
CMPATH for ISDN-DS
Fig. 36
SN2073EU01SN_0002
49
© 2002 Siemens AG
Siemens V5 Interface Administration
50 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
4 Exercise
SN2073EU01SN_0002
51
© 2002 Siemens AG
Siemens V5 Interface Administration
52 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
Exercise
Title: Functional Structure of V5 Interfaces
Objectives: The participant is able to describe the V5 database objects
Pre-requisite: none
Task
SN2073EU01SN_0002
53
© 2002 Siemens AG
Siemens V5 Interface Administration
54 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
5 Solution
SN2073EU01SN_0002
55
© 2002 Siemens AG
Siemens V5 Interface Administration
56 SN2073EU01SN_0002
© 2002 Siemens AG
V5 Interface Administration Siemens
Solution
Title: Functional Structure of V5 Interfaces
Objectives: The participant is able to describe the V5 database objects
Pre-requisite: none
Task
SN2073EU01SN_0002
57
© 2002 Siemens AG
Siemens V5 Interface Administration
58 SN2073EU01SN_0002
© 2002 Siemens AG