Download as rtf, pdf, or txt
Download as rtf, pdf, or txt
You are on page 1of 5

Test Lab Thermotron Industries

Holland 291 Kollen Park Drive


Holland, MI 49423

Report No: Saturday, April 20, 2024 18:46:17

1. Tester Information
Tester(s):
Address:
Phone Number:
E-mail:
Company:

2. Test Plan Specification


Design Verification Plan
& Report:
Test Specification:

File name: Test Example.rtf


Report Generated: 4/20/2024 at 18:46:17 1 of 5
Test Lab Thermotron Industries

Holland 291 Kollen Park Drive


Holland, MI 49423

Report No: Saturday, April 20, 2024 18:46:17

3. Test Data

Test: C2080-C2190 test 1 Hz to 300


Test Started Saturday, April 20, 2024 at 18:12:44
STOPPED at 18:46:08 on 4/20/2024
Total Run Time: 0 hours, 33 minutes, 24 seconds

Level: 1/1
Elapsed/Total: 00:30:00/00:30:00

Measurements:

Target: 1.600 G RMS


Control: 1.590 G RMS
Drive voltage: 0.254 V RMS

File name: Test Example.rtf


Report Generated: 4/20/2024 at 18:46:17 2 of 5
Test Lab Thermotron Industries

Holland 291 Kollen Park Drive


Holland, MI 49423

Report No: Saturday, April 20, 2024 18:46:17

4. Graphs

File name: Test Example.rtf


Report Generated: 4/20/2024 at 18:46:17 3 of 5
Test Lab Thermotron Industries

Holland 291 Kollen Park Drive


Holland, MI 49423

Report No: Saturday, April 20, 2024 18:46:17

File name: Test Example.rtf


Report Generated: 4/20/2024 at 18:46:17 4 of 5
Test Lab Thermotron Industries

Holland 291 Kollen Park Drive


Holland, MI 49423

Report No: Saturday, April 20, 2024 18:46:17

5. Detailed Test Definition

Filename: C:\Users\PCE Paragon Solution\Desktop\microsoft\Vib0096\B412241230017042\


C2080-C2190 test 1 Hz to 300 1.6 Grms X-B412241230017042.vcs
04/20/24, 18:46:17

Max Frequency: 500 Hz


Number of Lines: 800
Average Factor: 40.00
Sigma Clipping: 3.00
Control Channels: 1
Monitor Channels: 1

Abort Control Lines: 5


Min/Max Control RMS: -6.00/6.00 dB
Abort Monitor Lines: 5
Min/Max Monitor RMS: -6.00/6.00 dB
Max Start Output: 1.00 V RMS
Max Run Output: 1.50 V RMS

Reference Profile
Freq (Hz) g²/Hz dB/Oct
1 0.00010000 10.0000
4 0.01000000 0.0000
250 0.01000000 -76.0357
300 0.00010000 0.0000

Control Limits
Freq (Hz) + Tol - Tol + Abort - Abort (dB)
1 3.00 3.00 6.00 6.00
300 3.00 3.00 6.00 6.00

Monitor Limits: Disabled

Level Schedule: Countdown when in limits


# Time dB G RMS % Level Start
1 00:30:00 0.00 1.60 100.00 Normal

File name: Test Example.rtf


Report Generated: 4/20/2024 at 18:46:17 5 of 5