TECHNICAL INFO EXPRESS Indice

FOR SAVFR 21
INFORMATION EXPRESS TECHNIQUE A
MACHINE: DKS 4
1810 YES NO – 1890 YES NO
Date : 23/11/11. SAV IET N°04 V02 ed 01 Page : 1/5
SUMMARY/SOMMAIRE: Changing the Input board
Application on : Application mode/Modalité d’application :
Application sur : Immediately :immédiatement :
If necessary /si nécessaire : 
Periodically/périodiquement :
Next service call/lors d’un passage:

Problem:

The New Software V5.5.1 Beta needs a new Input board with more potentiometers.

Solution:

Change the Input board.

The new input board as ten potentiometers, and actually uses seven:

VR1 VR4 VR5 VR6 VR7 VR8 VR9

THESE INFORMATIONS ARE DESIGNED ONLY FOR TECHNICIANS AND ARE CONFIDENTIAL, AND NOT CONTRACTUAL.
CES INFORMATIONS SONT FAITES POUR DES TECHNICIENS ET SONT CONFIDENTIELLES ET NON CONTRACTUELLES.
Indice
TECHNICAL INFO EXPRESS FOR SAVFR 21
INFORMATION EXPRESS TECHNIQUE A
MACHINE: DKS 4
1810 YES NO – 1890 YES NO
Date : 23/11/11. SAV IET N°04 V02 ed 01 Page : 2/5

Once board changed, click “Input Test” in the software “Setting” interface.

Click “Refresh” as the picture shows.

THESE INFORMATIONS ARE DESIGNED ONLY FOR TECHNICIANS AND ARE CONFIDENTIAL, AND NOT CONTRACTUAL.
CES INFORMATIONS SONT FAITES POUR DES TECHNICIENS ET SONT CONFIDENTIELLES ET NON CONTRACTUELLES.
Indice
TECHNICAL INFO EXPRESS FOR SAVFR 21
INFORMATION EXPRESS TECHNIQUE A
MACHINE: DKS 4
1810 YES NO – 1890 YES NO
Date : 23/11/11. SAV IET N°04 V02 ed 01 Page : 3/5

Once click “Refresh”, then all the value will be shown in line “Input” .
We need to check the values in Input 1 and Input 2.

Each digit of values are reflecting a sensor status. Note VR9 status is on Input2.

THESE INFORMATIONS ARE DESIGNED ONLY FOR TECHNICIANS AND ARE CONFIDENTIAL, AND NOT CONTRACTUAL.
CES INFORMATIONS SONT FAITES POUR DES TECHNICIENS ET SONT CONFIDENTIELLES ET NON CONTRACTUELLES.
Indice
TECHNICAL INFO EXPRESS FOR SAVFR 21
INFORMATION EXPRESS TECHNIQUE A
MACHINE: DKS 4
1810 YES NO – 1890 YES NO
Date : 23/11/11. SAV IET N°04 V02 ed 01 Page : 4/5

Corresponding table

Input value
1 2 3 4 5 6 7 8
sensor sensor
Paper Photore
Paper for for
Try end sistance
end paper paper
Input senso sensor for lens
NC NC sensor feeding platfor
1 r (DOWN positioni
(UP) position m
VR1 ) ng
VR7 ing outlet
VR6
VR4 VR5
sensor
Photo sensor
for
resist for
Reverse Revers
ance Reverser upgrad
Input r er
for NC NC location e rack NC
2 location positio
cutter UP position
DOWN ning
positio ing
VR9
ning VR8

Sensor map:

THESE INFORMATIONS ARE DESIGNED ONLY FOR TECHNICIANS AND ARE CONFIDENTIAL, AND NOT CONTRACTUAL.
CES INFORMATIONS SONT FAITES POUR DES TECHNICIENS ET SONT CONFIDENTIELLES ET NON CONTRACTUELLES.
Indice
TECHNICAL INFO EXPRESS FOR SAVFR 21
INFORMATION EXPRESS TECHNIQUE A
MACHINE: DKS 4
1810 YES NO – 1890 YES NO
Date : 23/11/11. SAV IET N°04 V02 ed 01 Page : 5/5

Testing method:

Shelter from infrared LED(photodetector) with a photographic paper.


Click “Refresh” and observe the variation of corresponding values.

If Input value=1, it means the infrared LED works well.


If Input value=0, it means the infrared LED works abnormally. (Possible cause:
photocell pick-up gets damaged. Replace the photocell pick-up)

If Input value=1 after the photo moves away, adjustment method:

Adjustment method for VR4.VR6.VR7:


Rotate the corrsponding regulator of infrared LEDs in a clockwise direction (enhance
the sensitivity of infrared LEDs ). Click” Refresh” and observe the the variation of
corresponding values. At the moment it changes from 1 to 0, rotate 40 degrees
clockwise.

Adjustment method for VR5:


Rotate the corrsponding regulator of infrared LEDs in a clockwise direction (enhance
the sensitivity of infrared LEDs ). Click” Refresh” and observe the the variation of
corresponding values. At the moment it changes from 1 to 0, rotate 45 degrees
clockwise.

Adjustment method for VR9:


Rotate the corrsponding regulator of infrared LEDs in a clockwise direction (enhance
the sensitivity of infrared LEDs ). Click” Refresh” and observe the the variation of
corresponding values. At the moment it changes from 1 to 0, rotate 60 degrees
clockwise.