Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 2

Terminal Crimping Report

TERMINAL FEMEA 2,5MM XH ZUCH TP2502J-3


SUPPLIER DATE 13/12/2021
ZUCH
PRODUCER Sample PN CUSTOMER W11553091 WIRE SPEC 7/0,160 + 0,006 mm
CB FLEXÍVEL 26AWG
TER P/N TP2502J-3 SERIAL NUMBER 02TP2502J30001 WIRE TYPE
UL1007 XINYA
EQUIPMENT Terminal Analysis Measurement System
Name Value Result Found
Crimp Height Conductor 0.70+0.03mm 0.69mm
Crimp Width Conductor 1.44+0.03mm Acceptable 1.44mm
Crimp Height Insulation - -
Test Crimp Width Insulation - -
results Section Reduction Ratio NA 25>=x>=5
Compression Ratio NA 75<=x<=95
N° Conductor wire 7 OK 7
Bending angle NA x<=30.00Deg
Tensile test 15N Mín. OK 42,10N

Appearance discrimination
1.Not honey comb shaped pressing or gap inside Yes [ ] No [ × ]

2.Distance between terminal wall and wings is too short Yes [ ] No [ × ]

3.Distance between terminal bottom and wings is too short Yes [ ] No [ × ]

4.Burr height exceeds material thickness Yes [ ] No [ × ]

5.Burr width exceeds 1/2 of material width Yes [ ] No [ × ]

6.Crimping area to terminal body distorted. Yes [ ] No [ × ]

7.Crimp wing claws not rolled symmetrically Yes [ ] No [ × ]

8.Crimping crack Yes [ ] No [ × ]

9.Crimping is not closed or Of stands width Yes [ ] No [ × ]

10.Single strands outside or single strands squeezes between


Yes [ ] No [ × ]
crimp wings

No items should be found in photo while a crimping is accepted

OBSERVATION

Detection Test date 13/12/2021

Approve: Review by: Made by:


RUBERVALDO RUBERVALDO MOISES NOGUEIRA
BASTOS BASTOS