Professional Documents
Culture Documents
Agilent 5100 Series ICP-OES Consumables Ordering Guide (2)
Agilent 5100 Series ICP-OES Consumables Ordering Guide (2)
Agilent 5100 Series ICP-OES Consumables Ordering Guide (2)
2)
demountab
Contents
Peristaltic pump tubing
Nebulizers and supplies
Argon Humidifier Accessory
Spray chambers and supplies
One Piece and Semi-demountable Torches
Fully Demountable Torches
Miscellaneous torch supplies
MSIS supplies
Application kits for SVDV/VDV systems
Application kits for RV (radial) systems
Operating supplies kits
Wavelength calibration solutions for ICP-OES
Intelliquant calibration solutions
Miscellaneous supplies
Consumables for IsoMist
Consumables for AVS 4/6/7 Switching Valves
Tubing kits for AVS Switching Valves
Sample loops for AVS Switching Valves
Consumables for SVS 2+ and SVS 1+ Accessories
Page 1 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
3710034400 Pump tubing, PVC, white/white tabs, for acidic samples (pk/12 tubes)
3710034600 Pump tubing, PVC, blue/blue tabs, for acidic waste (pk/12 tubes)
3710046900 Pump tubing, PVC, orange/white tabs, for internal standard (pk/12 tubes)
3710044200 Pump tubing, Marprene, white/white tabs, for semi-volatile organic samples (pk/12
tubes)
3710044400 Pump tubing, Marprene, blue/blue tabs, for semi-volatile organic waste (pk/12
tubes)
Page 2 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
3710043700 Pump tubing, Viton, white/white tabs, for volatile organic samples (pk/12 tubes)
3710043900 Pump tubing, Viton, blue/blue tabs, for volatile organic waste (pk/12 tubes)
3710034800 Pump tubing, SolvaFlex, black/black tabs, for HF digested samples (pk/12 tubes)
3710035200 Pump tubing, SolvaFlex, gray/gray tabs, for HF waste (pk/12 tubes)
The listings above cover the standard pump tubing either supplied with the instrument or included in the
application kits.
Page 3 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Page 4 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
G8010-80035 UniFit Sample connector for U-Series glass concentric nebulizer, 10/pk.
Fitted with 0.75 mm id x 700 mm length capillary tubing. Connects the peristaltic
pump tubing for the sample line to the nebulizer.
Suits the U-Series nebulizer used with the 5100/5110 and 5800/5900 DV ICP-
OES.
Page 5 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
5043-0502 Conical adapter, 1/16 in od sample line for OneNeb Series 2 nebulizer.
Joins 1/16 in od sample capillary to peristaltic pump tubing.
Includes 1 conical PTFE adapter with
PTFE nut (female) and PTFE ferrule
and lock ring.
Page 6 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Page 7 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Spray Chambers and Supplies for 5100/5110 and 5800/5900 Series ICP-OES
Page 8 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Page 9 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
3710024600 Drain tubing for spray chamber waste, 0.12” id x 0.062” thick, per m.
Used to take waste liquid from the peristaltic pump tubing to a suitable waste
vessel.
G8010-40026 Clip to secure the drain tubing (used for spray chamber waste) to the front or
side of the sample tray.
G8010-80042 Replacement Helix seal for glass cyclonic spray chamber, 4/pk.
Suits any glass cyclonic spray chamber that uses the Helix fitting to secure the
nebulizer in the side arm of the spray chamber.
G8010-80043 Replacement Helix locking screw for glass cyclonic spray chamber, 1/pk.
Suits any glass cyclonic spray chamber that uses the Helix fitting to secure the
nebulizer in the side arm of the spray chamber.
Page 10 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
G8010-60232 Easy-fit semi-demountable high solids torch for 5000 Series DV ICP-OES
Features a 2.4mm ID injector with replaceable extended outer tube with slot for radial
viewing.
Recommended for high TDS samples using 5100/5110 and 5800/5900 VDV ICP-
OES
G8010-60233 Easy-fit semi-demountable torch for semi-volatile organics with 5000 Series
DV ICP-OES
This torch is now obsolete. It has been replaced by the fully demountable torch with
the 1.4mm ID quartz injector pn G8020-68002.
Page 11 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Replacement tube set for DV Torches used with the 5100/5110 and 5800/5900 Series ICP-OES
G8010-60263 Quartz outer tube set for 5000 Series DV ICP-OES, 1/pk
Tube set comprises extended outer tube with slot for radial viewing, intermediate tube
(integrated into assembly) and top seal (not shown in this image).
Suits 5100/5110 and 5800/5900 SVDV/VDV ICP-OES used with aqueous samples.
G8014-60022 Quartz outer tube set for 5000 Series DV ICP-OES used with organic solvents,
1/pk
High purity quartz outer tube set comprises extended outer tube
with slot for radial viewing, intermediate tube (integrated into
assembly) and top seal (not shown in this image).
Suits 5100/5110 and 5800/5900 SVDV/VDV ICP-OES used with
organic solvents. Identified by the “o” character to the right of the
alignment mark.
Page 12 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
G8012-60000 Easy-fit torch one piece for 5000 Series RV (radial) ICP-OES
Features a 1.4mm ID injector with a shorter outer tube (no slot) for dedicated radial
viewing (this is the standard torch for the radial instrument)
G8010-60235 Easy-fit semi-demountable torch for volatile organics with 5000 Series RV ICP-
OES
This torch is now obsolete. It has been replaced by the fully demountable torch with
the 0.8mm ID quartz injector pn G8020-68001.
G8010-60234 Easy-fit inert semi-demountable torch for 5000 Series RV (radial) ICP-OES
Features a ceramic 1.8mm ID injector with replaceable shorter outer tube (no slot)
for dedicated radial viewing. Supplied with plastic ball joint coupler for torch base
and large torch clamp for inert demountable torch (pn G8010-60227).
Recommended for HF digests using 5100/5110 and 5800/5900 RV (radial) ICP-OES
Page 13 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Replacement Tube set for RV Torches used with the 5000 Series RV (radial) ICP-OES Systems
G8010-60264 Quartz outer tube set for 5000 Series RV ICP-OES, 1/pk
Tube set comprises shorter length outer tube (no slot) for dedicated radial viewing,
intermediate tube (integrated into assembly) and top seal (not shown in image).
Suits 5100/5110 and 5800/5900 RV (radial) ICP-OES used with aqueous samples.
G8016-60000 Quartz outer tube set for 5000 Series RV ICP-OES used with organic solvents,
1/pk
High purity quartz outer tube set comprises shorter length outer tube
(no slot) for dedicated radial viewing, intermediate tube (integrated
into assembly) and top seal.
Suits 5100/5110 and 5800/5900 RV (radial) ICP-OES used with
organic solvents. Identified by the “o” character to the right of the
alignment mark.
Page 14 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
G8020-68001 Fully demountable Easy-fit torch with 0.8mm ID quartz injector for volatile
organics
Includes a replaceable shorter (high purity quartz) outer tube for organic applications
(no slot) for dedicated radial viewing. This torch with the 0.8mm ID tapered quartz
injector is recommended for routine analysis of volatile organic solvents such as
gasoline.
G8020-68002 Fully demountable Easy-fit torch with 1.4mm ID quartz injector for semi-volatile
organics
Includes a replaceable extended (high purity quartz) outer tube for organic
applications, with slot for radial viewing. This torch with the 1.4mm ID tapered quartz
injector is recommended for routine analysis of semi-volatile organic solvents such as
kerosene and xylene.
G8020-68003 Fully demountable Easy-fit inert torch with 1.8mm ID inert alumina injector for
HF digests
Includes Qty 2x (standard) replaceable extended outer tube with slot for radial
viewing. This torch with the 1.8mm ID alumina injector is recommended for routine
analysis of samples containing hydrofluoric (HF) acid.
G8020-68004 Fully demountable Easy-fit high TDS torch with 2.4mm ID quartz injector for
high TDS samples
Includes Qty 2x (standard) replaceable extended outer tube with slot for radial
viewing. This torch with the 2.4mm ID tapered quartz injector is recommended for the
analysis of high total dissolved solids (TDS) samples (up to 35% TDS).
G8020-68005 Fully demountable Easy-fit torch with 1.8mm ID quartz injector for routine
samples
Includes Qty 2x (standard) replaceable extended outer tube with slot for radial
viewing. This torch with the 1.8mm ID tapered quartz injector is recommended for
analysis of routine aqueous and acidic digests.
Page 15 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Replacement Injectors for the Fully Demountable Torches for 5100/5110 and 5800/5900 ICP-OES
Systems
G8020-60805 0.8 mm ID tapered quartz injector for the fully demountable torch
Recommended for routine analysis of volatile organic solvents such as gasoline.
G8020-60806 1.4 mm ID tapered quartz injector for the fully demountable torch
Recommended for routine analysis of semi-volatile organic solvents such as
kerosene and xylene.
G8020-60807 1.8 mm ID tapered quartz injector for the fully demountable torch
Recommended for analysis of routine aqueous and acidic digests.
G8020-60808 2.4 mm ID tapered quartz injector for the fully demountable torch
Recommended for the analysis of high total dissolved solids (TDS) samples (up to
35% TDS).
G8020-60809 1.8 mm ID inert alumina injector for the fully demountable torch
Recommended for routine analysis of samples containing hydrofluoric (HF) acid.
Page 16 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Miscellaneous Torch Supplies for 5100/5110 and 5800/5900 Series ICP-OES Systems
G8010-67000 Storage rack for torches used with 5000 Series ICP
Provides a convenient way to store torches
for the 5000 Series ICP-OES after cleaning.
Each rack holds up to 5 torches.
Multiple racks can be used and stacked
on top of each other, if required.
G8014-60023 Top seal for semi and fully demountable torches, pk/3
This seals the outer-tube set to the torch base.
G8020-60810 Injector locking nut for fully demountable torches used with
Agilent 5100/5110 and 5800/5900 ICP-OES instruments, 1/pack
This secures the injector in the torch base.
Page 17 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Page 18 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Includes:
• The MSIS assembly,
• Drain tubing assembly,
• Capillary tubing 0.01 in ID by 0.03 in OD
to join to peristaltic pump tubing for
reductant inlet, and
• Sample peristaltic pump tubing for
reductant and waste (1 tube each).
Note:
ALWAYS quote with the MSIS:
1 pack of peristaltic pump tubing for the reductant (pn 3710027200), and
1 pack of peristaltic pump tubing for the waste (pn 3710068900)
It is also recommended that the ICP-OES is fitted with a 5 channel peristaltic pump
for simultaneous hydride/non-hydride operation with the MSIS.
3710027200 Pump tubing, PVC, black/black tabs, for reductant solution (pk/12 tubes)
3710068900 Pump tubing, PVC, black/white tabs, for waste from MSIS (pk/12 tubes)
Page 19 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Page 20 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Application Kits for 5100/5110 and 5800/5900 Series SVDV/VDV ICP-OES Systems
These kits can be ordered with the instrument, but are also available as after-market items. These allow
the user to adapt the instrument to handle different applications. There are kits available for HF digests
(with inert components), semi-volatile organic solvents (such as kerosene), ketone based organic
solvents and volatile organic solvents (such as gasoline).
G8010-68007 Inert sample introduction kit for 5100/5110 and 5800/5900 DV ICP-OES 1/pk.
Recommended for use with HF digests.
Includes inert double pass spray chamber with ball joint socket, inert OneNeb Series
2 nebulizer, Easy-fit inert semi-demountable torch with ceramic injector (1.8mm ID)
and standard dual view outer tube-set, large torch clamp for inert torch and SolvaFlex
peristaltic pump tubes for sample (black/black tabs) and waste (gray/gray tabs).
Now supplied
with the
Agilent inert
spray chamber
eff. from Oct
15, 2019
Page 21 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
G8010-68029 Semi-volatile organics sample introduction kit for 5100/5110 and 5800/5900 DV
ICP-OES 1/pk.
Recommended for use with semi-volatile organic solvents incl. kerosene.
Includes double pass glass cyclonic spray chamber with ball joint socket, Conikal
nebulizer, fully demountable Easy-fit torch with 1.4mm ID quartz injector and dual
view outer tube-set for organics, solvent resistant drain tubing and PVC Solvaflex
NOTE: Now peristaltic pump tubes for sample (black/black tabs) and waste (grey/grey tabs).
supplied with
the Agilent
inert spray
chamber eff.
from Dec 9,
2019.
G8010-68009 Ketone based organics sample introduction kit for 5100/5110 and 5800/5900 DV
ICP-OES 1/pk.
Recommended for use with semi-volatile organic solvents incl. MIBK.
Includes double pass glass cyclonic spray chamber with ball joint socket, Conikal
nebulizer, fully demountable Easy-fit torch with 1.4mm ID quartz injector and dual
view outer tube-set for organics, solvent resistant drain tubing and Marprene
NOTE: Now peristaltic pump tubes for sample (white/white tabs) and waste (blue/blue tabs).
supplied with
the Agilent
inert spray
chamber eff.
from Dec 9,
2019.
Page 22 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
G8010-68005 Volatile organics sample introduction kit for 5100/5110 and 5800/5900 DV ICP-
OES 1/pk.
Recommended for use with volatile organic solvents incl. gasoline.
Includes Conikal nebulizer, fully demountable Easy-fit torch with 0.8mm ID quartz
injector and radial view outer tube-set for organics, solvent resistant drain tubing and
Viton peristaltic pump tubes for sample (white/white tabs) and waste (blue/blue tabs).
Now supplied Requires but does NOT include a cooled spray chamber. The IsoMist temperature
with the fully controlled spray chamber is recommended.
demountable
torch eff. from
Nov 7, 2019
Page 23 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Application Kits for 5100/5110 and 5800/5900 Series RV (radial) ICP-OES Systems
These kits can be ordered with the instrument, but are also available as after-market items. These allow
the user to adapt the instrument to handle different applications. There are kits available for HF digests
(with inert components), semi-volatile organic solvents (such as kerosene), ketone based organic
solvents and volatile organic solvents (such as gasoline).
G8010-68006 Inert sample introduction kit for 5100/5110 and 5800/5900 RV ICP-OES 1/pk.
Recommended for use with HF digests.
Includes inert double pass spray chamber with ball joint socket, inert OneNeb Series
2 nebulizer, Easy-fit inert semi-demountable torch with ceramic injector (1.8mm ID)
and standard radial view outer tube-set, large torch clamp for inert torch and
SolvaFlex peristaltic pump tubes for sample (black/black tabs) and waste (gray/gray
Now supplied tabs).
with the
Agilent inert
spray chamber
eff. from Oct
15, 2019
Page 24 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
G8010-68030 Semi-volatile organics sample introduction kit for 5100/5110 and 5800/5900 RV
ICP-OES 1/pk.
Recommended for use with semi-volatile organic solvents incl.kerosene.
Includes double pass glass cyclonic spray chamber with ball joint socket, Conikal
nebulizer, semi-demountable Easy-fit torch with 1.4mm ID injector and standard radial
view outer tube-set, solvent resistant drain tubing and PVC Solvaflex peristaltic pump
tubes for sample (black/black tabs) and waste (grey/grey tabs).
G8010-68008 Ketone based organics sample introduction kit for 5100/5110 and 5800/5900 RV
ICP-OES 1/pk.
Recommended for use with semi-volatile organic solvents incl. MIBK.
Includes double pass glass cyclonic spray chamber with ball joint socket, Conikal
nebulizer, semi-demountable Easy-fit torch with 1.4mm ID injector injector and
standard radial view outer tube-set, solvent resistant drain tubing and Marprene
peristaltic pump tubes for sample (white/white tabs) and waste (blue/blue tabs).
Page 25 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
G8010-68004 Volatile organics sample introduction kit for 5100/5110 and 5800/5900 RV ICP-
OES 1/pk.
Recommended for use with volatile organic solvents incl. gasoline.
Includes Conikal nebulizer, fully demountable Easy-fit torch with 0.8mm ID quartz
injector and radial view outer tube-set for organics, solvent resistant drain tubing and
Viton peristaltic pump tubes for sample (white/white tabs) and waste (blue/blue tabs).
Now supplied Requires but does NOT include a cooled spray chamber. The IsoMist temperature
with the fully controlled spray chamber is recommended.
demountable
torch eff. from
Nov 7, 2019
Page 26 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
G8012-67001 Operating supplies kit for 5000 Series RV (radial) ICP-OES. Includes:
1 x Easy Fit semi-demountable torch RV, 1.4mm injector
2 x Quartz standard outer tube sets for 5000 Series RV demountable torch
4 pks PVC peristaltic pump tubing for sample (12/pk white/white tabs)
4 pks PVC peristaltic pump tubing for waste (12/pk blue/blue tabs)
1 x Int. standard pump tubing & connectors
1 x SeaSpray nebulizer (U series)
1 pk Unifit connectors (0.75 mm ID) for nebulizer
1 x EzyLok gas connector for nebulizer
1 x Double pass glass cyclonic spray chamber with Helix fitting
1 pk Unifit connectors for spray chamber drain
1 x Torch clamp (secures the ball joint connection to the spray chamber
– suits the standard torch only)
1 x Spare pre-optic window for radial view
2 x Barb connectors, 1/16” id to 1/8” id
2m Nebulizer capillary tubing
0.5m PFA tubing for nebulizer gas supply
2m Drain tubing for waste liquid from spray chamber
1.5 m Drain tubing for spillage on sample tray
1 pk Helix seal for spray chamber
Page 27 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
6610030000 Checkout solution - Bottle wavelength calibration solution for ICP-OES and
MP-AES 500 mL 50ppm (concentrate)
Required at all installations to enable the Agilent installation engineer to complete
installation and performance tests as part of “installation and familiarization”.
This solution is also required periodically by the user for wavelength calibration of
the instrument.
Contains 50 mg/L Al, As, Ba, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Se, Sr, Zn and
500 mg/L K in 5% HNO3.
NOTE:
Dilute 10 times prior to use.
500 mL bottle.
Trace HF has now been removed!
6610030100 Bottle wavelength calibration solution for ICP-OES and MP-AES 500 mL
5ppm (ready to use)
Wavelength calibration solution for ICP-OES and MP-AES: 500 mL, contains
5 mg/L Al, As, Ba, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Se, Sr, Zn and
50 mg/L K in 5% HNO3.
NOTE:
Ready to use.
500 mL bottle.
Trace HF has now been removed!
5190-7001 Bottle calibration blank solution for ICP-OES and MP-AES 500 mL (0 ppm).
Pure ASTM Type 1A water with 5% HNO3.
Suitable for use as a calibration blank or to use for dilution of the wavelength
calibration solution.
Ready to use. 500 mL bottle.
Page 28 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
5190-8575 Intelliquant single element standard for Hg, 100 mL 10ppm (ready to use)
Single element Hg standard used to update the pre supplied IntelliQuant calibration
for semi quantitative analysis with 5110 DV ICP-OES. 100 mL bottle of 10 mg/L Hg
in 5% HNO3.
5190-7001 Bottle calibration blank solution for ICP-OES, 500 mL 0 ppm (ready to use).
Pure ASTM Type 1A water with 5% HNO3. Ready to use. 500 mL bottle.
Suitable for use as a calibration blank when updating the pre supplied IntelliQuant
calibration for semi quantitative analysis with 5110 DV ICP-OES.
Can also be used for dilution of the wavelength calibration concentrate.
Looking for For details of other Agilent single and multi-element standards available,
other please see:
standards? http://www.agilent.com/store/en_US/Cat-
SubCat1ECS_32478/Standards?navAction=pop&navCount=0
Page 29 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
G8020-68016 Filter element for the cooling air inlet on the 5800/5900 ICP-OES instrument.
Suits 5800/5900 ICP-OES systems only.
G8020-42000 Inlet duct adapter for the cooling air inlet on the 5800/5900
ICP-OES instrument.
The external inlet duct adapter can be used to connect a
supply of clean, dry air to the instrument from outside the
laboratory. A minimum flow of 4m3/min is required for use of
Will be price the duct adapter. Not included, but needed is additional
listed from 1st ducting, a blower and clamps.
Feb, FY20. Suits 5800/5900 ICP-OES systems only.
Page 30 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
G8000-68002 Filter for the cooling air inlet on the 5100/5110 ICP-OES instrument.
Suits 5100/5110 ICP-OES and MP-AES systems only.
G8010-60189 Replacement filter for the cooling air inlet on the 5100/5110 ICP-OES
Suits instruments fitted with the "Dusty Environment Air Inlet filter" option.
Only a replacement filter element is supplied.
Page 31 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Pre-optics window assembly for the axial view of the 5100/5110 and 5800/5900 SVDV/VDV ICP-OES
G8010-68018 Fluorocarbon O-ring for the axial view pre-optics window assembly
(item 3 above)
Suits the 5100/5110 SVDV/VDV ICP-OES
NOTE: The washer fitted between the locking bush and the assembly in both the axial and the
radial window assemblies (as fitted to PR and the first production instruments) is
no longer used
The material used for the window has also been changed effective from October 2014
Page 32 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Page 33 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
G8010-68011 PuraFlex transfer tube for IsoMist used with 5100/5110 and 5800/5900 ICP-OES,
1/pk
Required to connect the aerosol outlet from the IsoMist temperature controlled spray
chamber (ROL configuration) to the Easy-fit torch for the 5100/5110 and 5800/5900
ICP-OES.
G8010-68024 ICP spray chamber, Twister style encapsulated for IsoMist, 1/pk
Twister style (double pass) glass
cyclonic with thermal conductive
polymer encapsulation for use with
IsoMist (RoL configuration).
Page 34 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
G8495-60000 Spare valve, 7 port, 2 position for AVS 7 Switching Valve, 1/p
Replacement valve assembly for AVS 7
G8495-60003 Stator and rotor for 7 port valve for AVS 7 Switching Valve, 1/p
G8494-60002 Rotor seal for 6-7 port valve for AVS 6/7 Switching Valve, 1/p
G8010-20071 Drip Tray for 6-7 Port valve of AVS 6/7 Switching Valve, 1/pk
Page 35 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
G8494-60000 Spare valve, 6 port, 2 position for AVS 6 Switching Valve, 1/p
Replacement valve assembly for AVS 6
G8494-60003 Stator and rotor for 6 port valve for AVS 6 Switching Valve, 1/p
G8494-60002 Rotor seal for 6-7 port valve for AVS 6/7 Switching Valve, 1/p
G8010-20071 Drip Tray for 6-7 Port valve of AVS 6/7 Switching Valve, 1/pk
Page 36 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
G8493-60000 Spare valve, 4 port, 2 position for AVS 4 Switching Valve, 1/p
Replacement valve assembly for AVS 4
G8493-60003 Stator and rotor for 4 port valve for AVS 4 Switching Valve, 1/p
G8493-60002 Rotor seal for 4 port valve for AVS 4 Switching Valve, 1/p
Page 37 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Miscellaneous supplies for AVS Switching Valves Used with 5110 and 5800/5900 DV ICP-OES
G8494-60005 Rinse (10L) and waste (20L) containers for AVS 6/7
Includes 10L HDPE container for rinse solution and
20L HDPE container for waste both fitted with safety
caps to prevent vapors reaching the lab.
Supply lines fitted with sinkers to ensure the capillary
draws from the base of the container.
G8010-60300 Check Valve Outlet for AVS Switching Valve, Non-Metallic, 1/p
Page 38 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Tubing kits for AVS Switching Valves Used with 5110 and 5800/5900 DV ICP-OES
G8010-60303 Sample Inlet Connection Kit for AVS Switching Valve, 1/pk
G8010-60308 Pump Outlet Connection Kit for AVS Switching Valve, 1/pk
G8010-60334 Waste Tube Kit for 4 Port AVS Switching Valve, 1/pk
Includes swivel barb adaptor fitted with 2m length of 1/8" ID PVC tubing for the
AVS waste line
Page 39 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Sample Loops for AVS Switching Valves Used with 5110 and
5800/5900 ICP-OES
G8010-60305 Sample Loop for AVS Switching Valve, 1.0mL volume, 1/pk
This is the standard loop supplied with the AVS Switching Valves
G8010-60338 Sample Loop for AVS Switching Valve, 0.25mL volume, 1/pk
G8010-60339 Sample Loop for AVS Switching Valve, 0.5mL volume, 1/pk
G8010-60340 Sample Loop for AVS Switching Valve, 1.5mL volume, 1/pk
G8010-60341 Sample Loop for AVS Switching Valve, 2.0mL volume, 1/pk
G8010-60342 Sample Loop for AVS Switching Valve, 2.5mL volume, 1/pk
G8010-60343 Sample Loop for AVS Switching Valve, 3.0mL volume, 1/pk
G8010-60344 Sample Loop for AVS Switching Valve, 3.5mL volume, 1/pk
Page 40 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Image illustrates the SVS 2+ mounting bracket, pump and valve assembly
Tubing and tubing kits for SVS 2+ Accessory Used with 5100 ICP-OES
Sample loops used with the SVS 2+ are the same as those used with the SVS 2.
Refer to the listings of sample loops available (from 0.25 to 4.0mL volume) in the Spectroscopy
consumables catalog (Agilent publication # 5991-5455EN) or the on-line Store (in the ICP-OES section)
at the following URL:
http://www.chem.agilent.com/store/en_US/LCat-SubCat3ECS_36702/SVS-
2?navAction=push&navCount=6
Page 41 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Page 42 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
G8485-81001 Mounting bracket for SVS 2+ to suit 700 Series Axial ICP-OES, 1/p
Allows mounting of the SVS 2+ on the 700 Series axial ICP-OES.
G8485-80000 PTFE stator alignment and extraction tool for SVS 2+, 1/p
Page 43 of 44
Agilent 5800/5900 and 5100/5110 ICP-OES Consumables Ordering Guide (February 2020, Version 2.2)
Back to Contents
Other consumables used with the SVS 1+ are the same as those used with the SVS 1.
Refer to the listings of SVS 1 consumables in the Spectroscopy consumables catalog (Agilent
publication # 5991-5455EN) or the on-line Store (in the ICP-OES section) at the following URL:
http://www.chem.agilent.com/store/en_US/LCat-SubCat3ECS_36701/SVS-
1?navAction=push&navCount=2
Page 44 of 44