1 Introduction
EAL (Environmentally Acceptable Lubricant) is now widely used for vessels who
service in the US water, since 2013 VGP has been effective on 19th December 2013.
We know various remarks when EAL is used for stern tube seals and bearings.
Following is the explanation about EAL.
EAL requires the strict arrangements/specifications/operations for the sealing systems
in comparison with Mineral Oil.
As actual example used with EAL, abnormal wear especially #4 Seal Ring in FWD
stern tube seal has been observed, which causes EAL leakage. This can be
considered that deterioration of EAL by heat that causes poor lubrication, occurrence of
fine rust particles, residue & etc.
To prevent above mentioned issue, following operation is to be carried out strictly for
the purpose of eliminating any negative influence caused by EAL as much as possible.
© 2023 Wärtsilä Japan Ltd. – All rights reserved – Please read the complete disclaimer at the end of this document.
TECHNICAL BULLETIN
2 Operation
Proper maintenance of EAL condition in FWD stern tube seal L.O. circulation system
should be carried out for such as
© 2023 Wärtsilä Japan Ltd. – All rights reserved – Please read the complete disclaimer at the end of this document.
TECHNICAL BULLETIN
© 2023 Wärtsilä Japan Ltd. – All rights reserved – Please read the complete disclaimer at the end of this document.
TECHNICAL BULLETIN
Replacement with new EAL every 3,000 running hours is recommended in order to avoid
negative influence for FWD stern tube seal by acceleration of EAL deterioration from
preventive maintenance point of view.
NOTE:
In general, oil temperature relates to deterioration of EAL closely, and oil temperature in
vicinity of FWD Seal Rings tends to be high because temperature surrounding of FWD
stern tube seal is high and Seal Rings generate heat by sliding on the seal liner.
Remarks:
In case of forced circulation (distributed from stern tube L.O. line), check of EAL condition
every 3,000 hours by analysis agency, and replacement with new EAL according to
instruction by EAL manufacturer.
2. Conduct briefing prior to service work onsite according to previous Service Work
Report and TechRequest if any.
4. Polish the liner sliding surface to meet the required surface of Ra:0.6µm.
NOTE:
If above required surface roughness is not achieved by hand polish, report the risk of
premature failure of seal due to liner condition to Superintendent along with this fact, and
write it in Service Work Report.
5. In case receive an order of liner replacement, confirm the reason (background) of the
replacement, and investigate the condition of the liner currently equipped.
Replacement it with stainless-based liner is also an option, depending on the liner
condition. (Judgment is case by case)
NOTE:
Stainless steel liner has more durability than cast iron liner in terms of corrosion
resistance in degraded oil environments especially in deteriorated EAL environment.
© 2023 Wärtsilä Japan Ltd. – All rights reserved – Please read the complete disclaimer at the end of this document.
TECHNICAL BULLETIN
3 Contacts
If technical support is needed, please create a TechRequest in Wärtsilä Online Services.
For services, spare parts and/or tools, please contact your nearest Wärtsilä
representative or the Customer Support Centre (CSC):
www.wartsila.com/csc
4 Technical support
If technical support is needed, please create a TechRequest for further assistance.
When creating the TechRequest, please:
• Specify the service bulletin number DSTA00013057 in the subject field.
• Write the comments or questions in the description field.
• Attach photos if possible.
1. Customers using Wärtsilä Online Services can create the TechRequest directly in the
system.
2. Customers not connected to the Wärtsilä Online Services, please contact your
Wärtsilä network office or the Customer Support Centre (CSC) and they will convey
the information and create the TechRequest on your behalf.
www.wartsila.com/csc