Micro Controller X PXR
Micro Controller X PXR
Micro Controller X PXR
!"#$"% &$'$()*+,"-."#)(/#"+012(#1**"#
3$4#1+012(#1**"#+567+!"#$"%
809:;<<=>%
567 3$4#1+012(#1**"#+567
[<]++J")(/#"%+
!"#$"%&
'()*"+,-#..&
( Except PXR3 )
Further More
F)#'"+F8&+G$%.*)H++ enlarge
d !?1#(+G".(?+ compac
t
Helpful for designing of small
and thin panels and equipments.
56EB+ 56E>+
(Existing
+ model) (Existing
+ model)
22mm
56EB+(Existing model) 567B+ 14.2mm
0?)#)4("#+?"$'?(+
PXR4
PXR3 PXR7 PXR9
PXR5
T'+.#&
3)2/)*+:."#)($12
D#0 'G)-G)$G-
D#0 'G)-G)$*'2(
@@L$*&+I#$'G)-G)
@@L S#/)#&
5K1#-)$%'&$=:LM
J#12(+K)("#.#11L+%(#/4(/#" &O9+#)$*+-1/2($2'
+M%()2G)#GN+
&O9+#)$*+-1/2($2'+M567CN
!"#$%&'()$*+,-./0$/(*$
'-#&/)+'($,#1)+'($+,$
2/)#&-&''%$+($1'(%'&3+)0$
2+)"$456789:;<=>>?$$
@'$)"#$%&'()$-/(#.$+,$
2/,"/A.#$2+)"$2/)#&?$
BC,#$'%$)"#$/))/1"#*$
$-/1D+(E$%'&$2/)#&-&''%$
$+,$&#FG+&#*?H 6'G()/A.#$)'$/$N<4$&/+.$G,+(E$)"#$N<4$&/+.$3'G()+(E$/*/-)#&$
/I/+./A.#$/)$'-)+'(?$$
O+)"$)"+,$/*/-)#&P$/.,'$3'G()/A.#$)'$/$2/..?$
,"#-$2)*+P*14Q+.#1("4($2'+41R"# &O9+#)$*+-1/2($2'+M567BN
=:LU =:LV
!"#$)#&3+(/.$A.'1D$1/($
A#$-&')#1)#*$2+)"$)"#$
=:L9 )#&3+(/.$1'I#&$/I/+./A.#$
/)$'-)+'(?$
Q$5/,0$)'$+(,)/..$)"#$2+&+(E
!#&3+(/.$1'I#&
Q$5/,0$)'$&#-./1# @##$'($-/E#$R9?
C
567 3$4#1+012(#1**"#+567
[<]++J")(/#"%+
un ctions
S)#$1/%+L/24($12%+)2G+)P/2G)2(+1.($12%+ More f
!()2G)#G+"Y/$.-"2(+
Diverse control and tuning functions ... Capable of covering various controls within a wide range from simple
ON/OFF control to fuzzy PID control.
Front waterproof structure (conforming with NEMA-4X:IP66) ... The front panel is washable with water.
:.($12)*+L/24($12%+
Re-transmission output in 4 to 20 mA DC ... PV (process value), SV (set value) and MV (manipulated output value)
can be transferred to other measuring instrument.
8-step ramp/soak function ... Allows use as a simple programmable controller with a set value program.
,
RS-485 communication ... Selectable between MODBUS protocol and Z-ASCII (Fuji s original).
Digital input ... SV (set value) is selectable and various events are executable by external switches, etc.
Heating and cooling control ... Applicable to even a self-heating process.
Heater burnout alarm ... Equipment damage can be prevented.
Various alarm function ... Delay action, excitation/non-excitation selection or latch function can be combined with alarm.
Remote SV input ... SV (set value) can be selected with 1 to 5V DC signals from outside.
7"Z(#)2%-$%%$12+1/(./(+$2+B+(1+=D+-I+&0+ 7!ZB[>+41--/2$4)($12++
A cost corresponding to one temperature sensor can be Via the RS-485 interface, PXR is connectable with a
reduced just by connecting a PV transfer signal to a recorder. computer, programmable operation display and PLC.
Output signal:4 to 20 mA DC Programmable
Kinds of output:Any one of process value (PV), set value (SV), Computer operation display
control output (MV) and PV-SV (DV)
PXR3
PV transfer output
Temperature input
Fuji's UG series
DC4~20mA Fryer RS232C
Current control signal Signal converter Max. 30 controllers
Recorder PHF
connectable
RS485
Oil
AC power regulator
(APR) Heater
[Z%(".+#)-.\%1)Q+L/24($12++
Temperature gradient For control in a heat pattern
PXR3 PXR4 PXR5 PXR7 PXR9
control of furnace
Digital input
Ramp soak action command
ON: Start
OFF: Reset Temperature input &$'$()*+$2./(+
Thermocouple Temperature control of oven For changing set value readily
Furnace
Digital input
SSR drive output Set value change command
SV-7
Temperature input
SV-3
SV-4
SV-2
SV-5
SV-1
SV-6
Temperature input
Time
B
[<]++J")(/#"%+
]")($2'+)2G+411*$2'+412(#1*+ S)#$1/%+)*)#-+L/24($12+
Max. 3 points are settable.
For control of both heating and cooling with a single controller
Kind of alarm Action diagram
Heating and cooling outputs can be overlapped with each
Inverter Current
output 5#"4$%"+("-."#)(/#"+412(#1*+)4?$"R"G++
PH+#"-1("+!S+$2./(+L#1-+1/(%$G"+
To heater
Heater
Cattle shed in shed power supply Sequencer
APR Set temperature (SV)
1 to 5V DC
]")("#+P/#21/(+)*)#-+
Alarm output will be issued when heater burnout is detected. Control Temperature
output input
Power supply
100 to 240V AC, 50/60Hz (Ex. PXR5) Cell A Cell B Cell C Cell D Cell E
The temperature of each cell is set by the sequencer.
11
Power supply
12
,"-."#)(/#"+412(#1*+1L++ For stable temperature.
Control output 1 Fuzzy + PID control
32 7 .*)%($4+-1*G$2'+-)4?$2"+ applicable
33 10 Start/stop of auto tuning can be commanded externally.
Heater burnout
alarm output Digital input
MG 3 4 35 36
Auto tuning command
SW
ON: Start
OFF: Stop
Electromagnetic switch
Current
transformer (CT) Temperature
alarm
PV Tuning action
Thermocouple
SV Temperature Plastic molding
input machine
SSR SSR Raw material
Wired to PXR ON ON
Heater (with no polarities)
Temperature input
Electric furnace
Wired to heater
Heater
(through hole in CT)
>
567 3$4#1+012(#1**"#+567
[=]++5#1G/4(%+#)2'"
,H."+ 567C+ 567B+ 567A+ 567>+ 567@+ PXR4 Socket
+ + + + +
:(?"#%++
&O9+#)$*+-1/2($2'+(H."+M567BN+
^
[C]++567+:#G"#$2'+41G" B[×@^--+!$`"+
B > ^ A [ @ <D << <= <C <B B > ^ A [ @ <D << <= <C
=B×B[--+!$`" 567 @^×@^--+!$`" 567
&$'$( !."4$L$4)($12 91(" &$'$( !."4$L$4)($12 91("
B a!$`"+1L+L#12(+]+U+Eb B aJ#12(+G$-"2%$12%b
24 × 48 mm C 48 × 96mm Screw terminal type >
> aO2./(+%$'2)*b 96 × 96mm Screw terminal type @
Thermocouple ˚C , > aO2./(+%$'2)*b
Thermocouple ˚F 7 Thermocouple ˚C ,
RTD Pt100Ω 3-wire type ˚C 9 Thermocouple ˚F 7
RTD Pt100Ω 3-wire type ˚F ! Resistance bulb Pt100 3-wire type ˚C 9
1 to 5V DC I Resistance bulb Pt100 3-wire type ˚F !
4 to 20mA DC c 1 to 5V DC I
^ a012(#1*+1/(./(+<b 4 to 20mA DC c
Relay contact output I ^ a012(#1*+1/(./(+<b
SSR/SSC driving output 0 Relay contact output I
4 to 20mA DC output 8 SSR/SSC driving output 0
4 to 20mA DC output Note 1 8
A a012(#1*+1/(./(+=b
None d A a012(#1*+1/(./(+=b
Relay contact output None d
Note 1 I
SSR/SSC driving output Note 1 0 Relay contact output I
4 to 20mA DC output Note 1 8 SSR/SSC driving output 0
[ a7"R$%$12+41G"b < 4 to 20mA DC output 8
@ a:.($12)*+%."4$L$4)($12%+<b Re-transmission (4 to 20mA DC) 7
None D [ a7"R$%$12+41G"b <
Alarm 1 point < @ a:.($12)*+%."4$L$4)($12%+<b++
8 ramp/soak B None D
Alarm 1 point + 8 ramp/soak > Alarm 1 point <
Alarm 2 point Note 2 J Alarm for heater break Note 2 =
Alarm 2 point + 8 ramp/soak Note 2 e Alarm 1 point + Alarm for heater break Note 2 C
<D aO2%(#/4($12+3)2/)*b+ a51K"#+%/..*H+R1*()'"b 8 ramp/soak B
None 100 to 240V AC 9 Alarm 1 point + 8 ramp/soak >
English 100 to 240V AC S Alarm for heater break + 8 ramp/soak Note 2 ^
None 24V AC/24V DC 0 Alarm 1 point + Alarm for heater break + 8 ramp/soak Note 2 A
English 24V AC/24V DC c Alarm 2 point J
<< a:.($12)*+%."4$L$4)($12%+=b Alarm 2 point + 8 ramp/soak e
Alarm 2 point + Alarm for heater break + 8 ramp/soak Note 2 ]
<= None D D D
<C RS-485 Modbus interface 3 D D Alarm 3 point 3
RS-485 Z-ASCII interface 9 D D R-SP Note 2 &
Re-transmission + Digital input 1 point f D D R-SP + Alarm 2 point Note 2 5
Note 3
Re-transmission 7 D D <D aO2%(#/4($12+-)2/)*b+a51K"#+%/..*H+R1*()'"b+
Note 3 None 100 to 240V AC Note 4
Digital input 2 points , D D 9
RS-485 Modbus interface + Digital input 1 point S D D English 100 to 240V AC S
RS-485 Z-ASCII interface + Digital input 1 point E D D None 24V AC/24V DC Note 4 0
<B a912Z%()2G)#G+%."4$L$4)($12b English 24V AC/24V DC c
Non-standard parameter setting J << a:.($12)*+%."4$L$4)($12%+=b
<= None D D D
Note 1: Process alarm (2 points) (the codes “ F and G ” in the 9th digit) cannot be specified.
Note 2: Control output 2 (the codes “ A, C, and E ” in the 7th digit) cannot be specified. <C RS485 (Modbus) communication 3 D D
Note 3: Control output 2, communication digital input (2 points), alarm (2 points), and 24V power supply (the codes “ A, RS485 (Z-ASCII) communication 9 D D
C and E ” in the 7th digit, “ F and G ” in the 9th digit, and “ A, B, and C ” in the 10th digit) cannot be specified. Digital input 1 point ! D D
Digital input 2 points Note 3 , D D
567C+;+:.($12)*+$("-% RS485 (Modbus) communication + Digital input 1 point S D D
RS485 (Z-ASCII) communication + Digital input 1 point E D D
012("2(% 31G"*
Note 1: Cannot be combined with heater break alarm.
IG).(1#+L1#+&$2+#)$* ZZP CTK368715P1 (No. 2, 3, 6, 7 and H on the 9th digit cannot be specified.)
Note 2: Cannot be combined with RS485 + 1-point digital input.
B[×B[--+!$`"+ B > ^ A [ @ <D << <= <C
(V00 and W00 on the 11, 12, and the 13th digits cannot be specified.)
Note 3: In the case of 2-point digital input, either of control output 2 or heater break alarm or R-SP can be
A=×A=--+!$`" 567 selected.
(2-point digital input, control output 2 + heater break alarm cannot be specified at the same time.)
&$'$( !."4$L$4)($12 91(" Note 4: The parameter of manual operation is hidden when it is default setting.
B aJ#12(+G$-"2%$12%b
48 × 48 mm Screw-terminal type B
72 × 72 mm Screw-terminal type A
> aO2./(+%$'2)*b The default settings of input signals, measured ranges, and setting values are
Thermocouple ˚C , shown below.
Thermocouple ˚F 7
Resistance bulb Pt100 3-wire type ˚C 9 ,?"#-141/.*"+%."4$L$"G+ ; Thermocouple K, Measured range: 0 to 400˚C,
Resistance bulb Pt100 3-wire type ˚F ! Setting value: 0˚C
1 to 5V DC I 7"%$%()24"+P/*P+%."4$L$"G+ ; Pt, Measured range: 0 to 150˚C, Setting value: 0˚C
4 to 20mA DC c S1*()'"T+0/##"2(+%."4$L$"G+ ;++Scaling: 0 to 100%, Setting value: 0%
^ a012(#1*+1/(./(+<b
Relay contact output I In any case other than the description above, specify input signals and measured
SSR/SSC driving output 0 range.
4 to 20mA DC output Note 1 8 The input signals for the thermocouple and the resistance bulb can be switched
A a012(#1*+1/(./(+=b with the front panel keys.
None d
Relay contact output Note 2 I The default settings of control action is reverse for control output 1 and direct for control
SSR/SSC driving output Note 2 0
output 2.
4 to 20mA DC output Note 2 8
Re-transmission (4 to 20mA DC) Note 2 7 The reverse and direct actions can be switched with keys on the face panel.
[ a7"R$%$12+41G"b <
@ a:.($12)*+%."4$L$4)($12%+<b
None D
Alarm 1 point < 567B\>\@+;+:.($12)*+$("-%
Alarm for heater break Note 3 =
Alarm 1 point + Alarm for heater break 012("2(% 31G"*
Note 3 C
8 ramp/soak B ,"#-$2)*+01R"#+ PXR4/7 : ZZP PXR1-A230
Alarm 1 point + 8 ramp/soak > PXR5/9 : ZZP PXR1-B230
Alarm for heater break + 8 ramp/soak Note 3 ^ 0,+L1#+?")("#+P/#21/(+)*)#- 1~30A: ZOZ CCTL-6-S-H
Alarm 1 point + Alarm for heater break + 8 ramp/soak Note 3 A 20~50A: ZOZ CCTL-12-S36-8
Alarm 2 point J
Alarm 2 point + 8 ramp/soak e
Alarm 2 point + Alarm for heater break + 8 ramp/soak Note 3 ]
Alarm 3 point 3
R-SP Note 3 & Note 1: Cannot be combined with heater break alarm.
R-SP + Alarm 2 point Note 3 5 ( 2, 3, 6, 7, H cannot be specified on 9th digit.)
<D aO2%(#/4($12+3)2/)*+L1#ba51K"#b+ Note 2: In case of the combination 9th digit code:3, 7, F, G, H, M or P and PXR4 the following
None 100 to 240V AC Note 5 9 installation condition are required.
English 100 to 240V AC S 1) Max.ambient temperature: 40°C
None 24V AC/24V DC Note 5 0 2) Individual mounting. (Side-by-side mounting is not allowed.)
English 24V AC/24V DC c Note 3: Cannot be combined with RS485 + 1-point digital input.
(V and W cannot be specified on 11th digit.)
<< a:.($12)*+%."4$L$4)($12%+=b Note 4: In the case of control output 2, either of heater break alarm or remote SV input can be
<= None D D D selected.
<C RS 485 (Modbus) 3 D D (A, C, E and R on the 7th digit, and 2,3,6,7,H, D and P on the 9th digit cannot be specified.)
RS 485 (Z-ASCII) 9 D D Note 5: The parameter of manual operation is hidden when it is default setting.
Digital input (1 point) ! D D
Digital input (2 point) Note 4 , D D
RS 485 (Modbus) + Digital input (1 point) S D D
RS 485 (Z-ASCII) + Digital input (1 point) E D D A
567 3$4#1+012(#1**"#+567
[B]++!."4$L$4)($12%
e"2"#)*+%."4$L$4)($12% 012(#1*+L/24($12%+1L+?")($2'\411*$2'+412(#1*+(H."+M1.($12N
Power supply voltage 100 V (-15%) to 240 V (+10%) AC, 50/60 Hz or Control action PID control (with auto tuning)
24 V (±10%) AC 50/60 Hz, 24 V (±10%) DC Heating side 0 to 999.9 % of measuring range
Power consumption When using 100 V AC: 6 VA (PXR3),8 VA (PXR4,7),10 VA (PXR5,9) proportional band (P)
When using 220 V AC: 8 VA (PXR3),10 VA (PXR4,7),12 VA (PXR5,9) Cooling side Heating side "P" × cooling side coefficient
When using 24 V AC/DC: 8 VA (PXR3),10VA (PXR4,7),12VA (PXR5,9) proportional band (P) (Automatically set in auto tuning)
Insulation resistance 20 MΩ or more (500 V DC) Cooling side proportional band coefficient: 0 to 100.0
Dielectric strength Power supply-ground ... 1500 V AC for 1 min On/off action if P=0
Power supply-others ... 1500 V AC for 1 min Integral time (I) 0 to 3200 sec (common to heating and cooling sides)
Ground-relay output ... 1500 V AC for 1 min Differential time (D) 0 to 999.9 sec (common to heating and cooling sides)
Ground-alarm output ... 1500 V AC for 1 min P,I,D=0:ON/OFF action (without dead band) for heating and cooling
Others ... 500 V AC for 1 min I,D=0:Proportional action
Input impedance Thermocouple: 1 MΩ or more Proportional cycle 1 to 150 sec
Voltage: 450Ω k or more For relay contact output or SSR/SSC drive output only
Current: 250Ω (external resistor) Hysteresis width 0.5% of measuring range common to heating and
Allowable signal Thermocouple: 100Ω or less cooling sides, For On/off action only
source resistance Voltage: 1kΩ or less Anti-reset windup 0 to 100% of measuring range
Allowable wiring Resistance bulb: 10Ω or less per wire Automatically validated at auto tuning
resistance Overlap, dead band ±50% of heating side proportional band
Reference junction ±1˚C (at 23˚C) Input sampling cycle 0.5 sec
compensation accuracy Control cycle 0.5 sec
Input value correction ±10% of measuring range Manual operation Manual operation -3 to 103% (except for PXR3)
Set value correction ±50% of measuring range
Input filter 0 to 900.0 sec settable in 0.5 sec steps (first order lag filter) :/(./(+%"4($12+1L+?")($2'\411*$2'+412(#1*+(H."+M412(#1*+1/(./(+=N+M1.($12N
Noise reduction ratio Normal mode noise (50/60 Hz): 50 dB or more Control output 2 Select one as follows
Common mode noise (50/60 Hz): 140 dB or more Relay contact: SPST contact:
Applicable standards UL (UL873) 220V AC/30V DC, 3A (resistive load)
CSA (C22.2 No.24-93) ... Not available on 72x72mm size Mechanical life 10 million operations (no load)
CE mark (LVD : EN61010-1, EMC : EN61326-1) Electrical life 100,000 operations (rated load)
Minimum switching current 100mA (24V DC)
012(#1*+L/24($12+1L+%()2G)#G+(H." For PXR3, 10 mA (5 V DC)
Control action PID control (with auto tuning, self-tuning) SSR/SSC drive (Voltage pulse):
Fuzzy control (with auto tuning) ON: 17 to 25 V DC, For PXR3, 12 to 16 V DC
Proportional band (P) 0 to 999.9% of measuring range settable in 0.1% OFF: 0.5V DC or less
steps Max. current: 20mA or less
Integral time (I) 0 to 3200 sec settable in 1 sec steps 4 to 20mA DC: Allowable load resistance 600Ω or less
Differential time (D) 0 to 999.9 sec settable in 0.1 sec steps For PXR3, 100 to 500Ω
On/off action if P = 0. Proportional action when I, D = 0.
Proportional cycle 1 to 150 sec settable in 1 sec steps :."#)($12+)2G+G$%.*)H+%"4($12
Only for relay contact output or SSR/SSC drive output Parameter setting Digital setting by 3 keys
Hysteresis width 0 to 50% of measuring range method With key lock function
For On/off action only Display Process value/set value Selective display
Anti-reset windup 0 to 100% of measuring range (PXR3 : Single display)
Automatically validated at auto tuning 4 digits, 7-segment LED
Input sampling cycle 0.5 sec Status display LED Control output, process alarm output, Heater
Control cycle 0.5 sec burnout alarm output (unavailable for PXR3)
Setting accuracy 0.1% or less of measuring range
O2./(+%"4($12 Indication accuracy Thermocouple: (0.5% of measuring range)
Input signal Thermocouple : J, K, R, B, S, T, E, N, PLII (at 23˚C) 1 digit 1˚C
Resistance bulb : Pt100 For thermocouple R at 0 to 500˚C ...
Voltage, current: 1 to 5 V DC, 4 to 20 mA DC (1% of measuring range) 1 digit 1˚C
(Apply current input after connecting the furnished For thermocouple B at 0 to 400˚C ...
250Ω resistor to input terminal.) (5% of measuring range) 1 digit 1˚C
Measuring range See measuring range table Resistance bulb, voltage/current:
Burnout For thermocouple or resistance bulb input Control (0.5% of measuring range) 1 digit
output upper/lower are selectable
I*)#-+M1.($12N
:/(./(+%"4($12+1L+%()2G)#G+(H."+M412(#1*+1/(./(+<N
Alarm kind Absolute alarm, deviation alarm, zone alarm
Control output 1 Select one as follows with upper and lower limits for each
Relay contact: SPDT contact: Hold function available (see page 15)
220V AC/30V DC, 3A (resistive load) Alarm latch, Excitation/non-excitation selecting
For PXR3, SPST contact function provided
Mechanical life 10 million operations (no load) Alarm ON-delay Delay setting 0 to 9999 sec settable in 1 sec steps
Electrical life 100,000 operations (rated load) Process alarm output Relay contact: SPST contact: 220 V AC/30 V DC,
Minimum switching current 100mA (24V DC) 1 A (resistive load)
For PXR3, 10 mA (5 V DC) Mechanical life 10 million operations (no load)
SSR / SSC drive (Voltage pulse): Electrical life 100,000 operations (rated load)
ON: 17 to 25 V DC, For PXR3, 12 to 16 V DC Minimum switching current 100 mA (5 V DC)
OFF: 0.5V DC or less For PXR3, 10 mA (5 V DC).
Max. current: 20mA or less MAX 2 points (PXR3), MAX 3 points (PXR4, 5, 7, 9)
4 to 20mA DC: Allowable load resistance 600Ω or less output cycle 0.5 sec
For PXR3, 100 to 500Ω
[
[B]++!."4$L$4)($12%
]")("#+P/#21/(+)*)#-+M1.($12T+/2)R)$*)P*"+L1#+567CN+ :(?"#+L/24($12%+
Heater current Current detector: CTL-6-S-H for 1 to 30 A / Parameter mask Parameter display is disabled by software.
detection (option), CTL-12-S36-8 for 20 to 50 A function
unavailable for PXR3 Current detection accuracy: 10% of measuring range Ramp/soak function 2 program pattern of 4 steps each, or 1 program
Alarm settable range: 1 to 50 A (option) parttern × 8 steps
Available only when control output is relay contact Digital input allows to start/reset the action.
or SSR/SSC drive.
However, detection is possible when control output 51K"#+L)$*/#"+.#14"%%$2'+
ON lasts 500 ms or longer. Memory protection Held by non-volatile memory
Heater burnout alarm Relay contact: SPST contact:
output 220 V AC/30 V DC, 1 A (resistive load) !"*LZ4?"4Q+
unavailable for PXR3 Mechanical life 10 million operations (no load) Method Program error supervision by watchdog timer
Electrical life 100,000 operations (rated load)
Minimum switching current 100 mA (24 V DC) :."#)($12+)2G+%(1#)'"+412G$($12%+
1 output, output updating cycle 0.5 sec Ambient operating -10˚C to 50˚C
temperature
&$'$()*+$2./(+M1.($12N+ Ambient operating Less than 90% RH (no condensation)
Points 1 or 2 humidity
Electrical specifications 5 V DC, approx. 2 mA (OFF judgment for 3 V DC Storage temperature -20˚C to 60˚C
or more, ON judgment for 2 V DC or less)
Input pulse width Min. 0.5 sec :.($12)*+$("-%+
Function Set value (front SV, SV1 to 3) changeover Current detector (CT) For 1 to 30 A: CTL-6-S-H
(any one settable) Control action start/stop (unavailable for PXR3) For 20 to 50 A: CTL-12-S36-8 (see page 17)
Ramp/soak action start / reset DIN rail mounting ZZP*CTK368715P1 (for outline diagram, see page 11)
Auto tuning start / stop adapter (for PXR3)
Alarm latch cancel and built-in timer start Terminal cover PXR4 : ZZPPXR1-A230
PXR5/9 : ZZPPXR1-B230
,$-"#+L/24($12+M1.($12N+ (for outline diagram, see page 11)
Start By digital input Instruction manual For communication function
Setting 0 to 9999 sec settable in 1 sec steps (see list of related documents on page 10)
Action Event ON-delay or OFF-delay
Signal output Alarm output relay used. Up to 3 points available. !(#/4(/#"+
Mounting method Panel flush mounting
01--/2$4)($12+L/24($12+M1.($12N+ PXR3 can be mounted to rail/wall by using the
Physical specifications EIA RS485 DIN rail mounting adapter available at option.
Communication protocol ModbusTM RTU mode or PXR protocol (Z-ASCII) External terminal Plug-in terminal (PXR3) or M3 screw terminal (PXR4, 5, 7, 9)
Communication method 2 wire method. Half duplex bit serial, start-stop sync type. Case material Plastic (non-combustible grade UL94V-0 equivalent)
Data type 8 bits. Parity: odd/even/none. Dimensions See the outline diagram on page 11.
Communication rate 9600bps Weight Approx. 150 g (PXR3), 200 g (PXR4), 250g (PXR7)
Connection aspect multi-drop/up to 32 controllers connectable including master station 300 g (PXR5), 300 g (PXR9)
Communication distance Total extension 500 m or less. Protective structure Front waterproof structure: NEMA4X (IEC standard
RS232C / RS485 Isolated type IP66 equivalent)(when mounted on panel with our
Signal converter Manufacturer: SYSMEX RA Co.,Ltd (Japan) genuine packing. Waterproof feature unavailable
(recommendation) Model: RC-770X in close mounting of multiple units)
http://www.sysmex-ra.co.jp Rear case: EC IP20
Manufacturer: OMRON Co., Ltd (Japan) Outer casing Black (front frame, case)
Model: K3SC-10
http://www.omron.co.jp/ !41."+1L+G"*$R"#H+
Scope of delivery Controller, panel mounting bracket, front watertight
7"Z(#)2%-$%%$12+1/(./(+L/24($12+M1.($12N+
packing, instruction manual, 250 resistor
Output signal DC 4-20mA (for current input)
Load resistance 500Ω or less (PXR3), 600Ω or less (PXR4, 5, 7, 9)
Output updating 500ms
3")%/#$2'+#)2'"+()P*"+
Output accuracy 0.3% FS (at 23˚C)
Resolution 2000 or more input signal measuring range(˚C) measuring range(˚F)
Kind of output signal Any one among PV, SV, DV and MV resistance bulb Pt100 -199 to 850 * -326 to 1562
(selectable by parameter) Thermocouple J 0 to 800 32 to 1472
K 0 to 1200 32 to 2192
7"-1("+%"(.1$2(+ R 0 to 1600 32 to 2912
+M1.($12T+21(+)R)$*)P*"+12+=BUB[--+%$`"N+ B 0 to 1800 32 to 3272
Input signal 1 to 5 V DC, 1 point S 0 to 1600 32 to 2912
Accurcy ±0.5% 1 digit (at 23˚C) T -150 to 400 -238 to 752
Input sampling cycle 0.5 sec E -150 to 800 -238 to 1472
Input scaling Allowed N 0 to 1300 32 to 2372
Display of remote mode LED on Front panel PLII 0 to 1300 32 to 2372
Input impedance 1MΩ or more DC voltage 1 to 5V scaling range -1999 to 9999
DC current 4 to 20mA
Note 1: For current input connect the supplied 250Ω resister at the input terminal.
Note 2: When the measuring range exceeds 1000˚C (1832˚F), decimal point
cannot be used.
* PXR3’ s Measuring range for Pt100 is -150 to 850˚C (-238 to 1562˚F)
@
567 3$4#1+012(#1**"#+567
[B]++!."4$L$4)($12%
O2%/*)($12+P*14Q+G$)'#)-
Power supply section Measurement input
Heater current detector input
Relay contact control output 1 Remote SV input
Internal circuit
Relay contact control output 2 Voltage pulse, 4 to 20mA DC control output 1 Note: Basic insulation (dielectric
Voltage pulse, 4 to 20mA DC control output 2 strength 1500 V AC) between
Alarm relay output 1
Transfer output blocks delimited by line .
Alarm relay output 2 Digital input (In case of Re-Transmission by PXR3) Functional insulation (dielectric
strength 500 V AC) between blocks
Communication (RS-485)
Alarm relay output 3 or heater break alarm output delimited by line .
Digital input (In case of Re-Transmission by
(PXR3 not included) Non isolated between blocks which
PXR3, 4, 5, 7, 9)
are not delimited from each other.
0)/($12+$2+/%" 012(#1*+1/(./( F$%(+1L+#"*)("G+G14/-"2(%
31G"* S1*()'"+./*%+ML1#+!!7+G#$R"N &0+B+(1+=D+-I 567C 567BT+A 567> 567@
S1*()'" 3)UV+0/##"2( I**1K)P*"+*1)G+#"%$%()24"
Instruction manual TN1PXR3-E TN1PXR-E TN1PXR5/9-E
567C 15V DC 20mA 100 to 500Ω
567BT+>T+AT+@ 24V DC 20mA 600Ω or less Operation manual ECNO:409 ECNO:406
56SC 5.5V DC 20mA 600Ω or less Communication MODBUS TN512642-E
56S 24V DC 60mA 600Ω or less function manual Z-ASC TN512644-E
56E 24V DC 60mA 600Ω or less
56g 24V DC 60mA 600Ω or less The above documents can be downloaded from our Internet home page.
http://www.fic-net.jp/eng
Differences from other models are listed at left. For replacement,
check is required to see if the specifications of control end are satisfied.
31/2($2'+(1+&O9+#)$*+M567C+12*HN+ ,"#-$2)*+41R"#+M567BT+>T+@N
Mountable to a DIN rail using the DIN rail mounting adapter The terminal block can be protected by the terminal cover
available at option. With this adapter, also mountable to a wall. available at option.
=:LU =:LV
=:L9
-OUNT 082
!#&3+(/.$1'I#&
WW==:LR8TXMY
!#&3+(/.$1'I#&
WW==:LR87XMY
36
#
-
#
!,
!,
3%,
082
$). RAIL -&$
.O
$). RAIL MOUNTING ADAPTER 4IGHTENING TORQUE .M OR LESS
OPTION
Caution on drilling in panel: In case of coating, etc. after drilling, the above dimensions must be followed in the finished status.
<D
[>]++:/(*$2"+)2G+5)2"*+0/(1/(+&$-"2%$12%
(unit: mm)
Type Outline Panel cut
O/)#&-&''%$-/1D+(E R 6'G()+(E$A&/1D#) &OR MOUNTING CLOSE TOGETHER N CONTROLLERS
9Z uN
@J
]R
]X
M9?X
X9
XX
7\R
PXR3
-).
7\X
@5\
V[
9 VZ -). .OTE 7ATERPROOF FEATURE IS UNAVAILABLE IF MOUNTED
=/(#.$)"+1D(#,,$BR$$$$)$$$$ZH CLOSE TOGETHER
R
-).
]R ]X 7\R 7\X 7\M
PXR4 =J
99?Z
9Z
9Z
-).
PXR7
-).
T t
0ACKING FOR WATER PROOF 4ERMINAL COVER !VALABLE OPRIONALLY
uN
-).
RY[?U$67:?
PXR5
VM?[
V>
VR?U
-).
RY[?U$67:?
PXR9
V>
VR?U
VM?[
-).
)
O/)#&-&''%$-/1D+(E =/(#. $BR$$$$)$$$$ZH !#&3+(/.$1'I#&$B'-)+'(H
<<
567 3$4#1+012(#1**"#+567
[^]++8U("#2)*+4122"4($12+G$)'#)-
2E 4RANSMISSION OUTPUT
n
0ROCESS ALARM OUTPUT OR
#ONTROL OUTPUT $IGITAL INPUT 5SABLE WIRING MATERIAL
,i>ÞÊVÌ>VÌÊÕÌ«ÕÌ 7IRE
{ÊÌÊÓäÊÊ ÊÕÌ«ÕÌ 4YPE 3INGLE 7IRE
--,É-- Ê`ÀÛiÊÕÌ«ÕÌ $IGITAL INPUT 'AUGE !7' MM TO !7' MM
#OMMUNICATION 3TRIP OFF LENGTH TO MM
23
n n
!7' TO !7'
TO MM
PXR3
! " " "AR TERMINAL
$IMENSION OF STRIP OFF CONDUCTOR SECTION X MM
,iÃÃÌ>ViÊLÕLÊ«ÕÌ ,i>ÞÊVÌ>VÌÊÕÌ«ÕÌ *ÀViÃÃÊ>>ÀÊ *ÜiÀÊÃÕ««Þ OR SMALLER
ÕÌ«ÕÌÊ£ £ääÊÌÊÓ{ä6Ê ,ENGTH OF STRIP OFF CONDUCTOR SECTION TO MM
xäÉÈäâ
NJ n n
-!8
/ iÀVÕ«i {ÊÌÊÓäÊÊ
«ÕÌ ÕÌ«ÕÌ n
{ÊÌÊÓäÊÊ -!8 TO MM
«ÕÌ Ó{6Ê
ÕÌÊÀiÃÃÌÀÊÌÊ n n Ó{6Ê ÊxäÉÈäâÊn6
ÌiÀ>ÃÊLiÌÜii
ÊÊÊÊÊ>`
£ÊÌÊxÊ6Ê --,É-- Ê`ÀÛiÊÕÌ«ÕÌ
«ÕÌ
#ONTROL OUTPUT
¬Ê7ITHOUT COMMUNICATION
FUNCTION $IGITAL INPUT ÌiÊ£\Ê--,É-- Ê`ÀÛiÊÕÌ«ÕÌÊ>`Ê
#ONTROL OUTPUT Ê {ÊÌÊÓäÊÊ ÊÕÌ«ÕÌÊ
Ê >ÀiÊÌÊiiVÌÀV>ÞÊÃÕ>Ìi`Ê
Ê vÀÊÌiÀ>ÊVÀVÕÌ°ÊÊ
,i>Þ {ÊÌÊÓäÊÊ --,É-- Ê Ê
VÌ>VÌ 1ÃiÊ>Ê}ÀÕ`i`ÊÃiÃÀ°
ÕÌ«ÕÌ `ÀÛiÊÕÌ«ÕÌ
*ÀViÃÃÊ>>ÀÊÕÌ«ÕÌÊ£ ÕÌ«ÕÌ
n n
*ÀViÃÃÊ>>ÀÊÕÌ«ÕÌÊÓ
,iÃÃÌ>ViÊLÕL 0ROCESS VARIABLE INPUT
i>ÌiÀÊLÕÀÕÌÊ>>ÀÊÕÌ«ÕÌ «ÕÌ
ÀÊ«ÀViÃÃÊ>>ÀÊÕÌ«ÕÌÊÎÊ £ÊÌÊxÊ6Ê
!
«ÕÌ
"
Ó{6Ê *ÜiÀÊÃÕ««Þ
Ó{6Ê £ääHÓ{ä6Ê ÓxäNJ
xäÉÈäâ xäÉÈäâ "
n n n
£Ó6
/ iÀVÕ«i {ÊÌÊÓäÊÊ
«ÕÌ «ÕÌ
,iÌÀ>Ã --,É-- ,i>ÞÊVÌ>VÌÊÕÌ«ÕÌ
{ÊÌÊÓä ÕÌÊÀiÃÃÌÀÊÌ
ÃÃ `ÀÛi #ONTROL OUTPUT i>ÌiÀÊVÕÀÀiÌ
ÕÌ«ÕÌ ÌiÀ>ÃÊLiÌÜiiÊÊÊÊÊ>`
ÕÌ«ÕÌ ÕÌ«ÕÌ
n n n `iÌiVÌÀÊ«ÕÌ ,-*Ê«ÕÌ
$IGITAL INPUT
$IGITAL INPUT
$IGITAL INPUT POINT
PXR4
PXR7
,iÌÀ>Ã --,É-- ,i>ÞÊVÌ>VÌÊÕÌ«ÕÌ i>ÌiÀÊVÕÀÀiÌ
{ÊÌÊÓä ,-*Ê«ÕÌ
ÃÃ `ÀÛi `iÌiVÌÀÊ«ÕÌ
ÕÌ«ÕÌ #ONTROL OUTPUT
ÕÌ«ÕÌ ÕÌ«ÕÌ
n n n
¬Ê7ITH COMMUNICATION
FUNCTION #OMMUNICATION
23 #ONTROL OUTPUT ÌiÊ£\Ê--,É-- Ê`ÀÛiÊÕÌ«ÕÌÊ>`Ê
Ê {ÊÌÊÓäÊÊ ÊÕÌ«ÕÌÊ
n Ê >ÀiÊÌÊiiVÌÀV>ÞÊÃÕ>Ìi`Ê
Ê vÀÊÌiÀ>ÊVÀVÕÌ°ÊÊ
,i>Þ {ÊÌÊÓäÊÊ --,É-- Ê Ê 1ÃiÊ>Ê}ÀÕ`i`ÊÃiÃÀ°
VÌ>VÌ ÕÌ«ÕÌ `ÀÛiÊÕÌ«ÕÌ
*ÀViÃÃÊ>>ÀÊÕÌ«ÕÌÊ£ ÕÌ«ÕÌ n n
*ÀViÃÃÊ>>ÀÊÕÌ«ÕÌÊÓ
,iÃÃÌ>ViÊLÕL 0ROCESS VARIABLE INPUT
i>ÌiÀÊLÕÀÕÌÊ>>ÀÊÕÌ«ÕÌÊ «ÕÌ
ÀÊ«ÀViÃÃÊ>>ÀÊÕÌ«ÕÌÊÎ ! £ÊÌÊxÊ6Ê
«ÕÌ
"
Ó{6Ê *ÜiÀÊÃÕ««Þ
Ó{6Ê £ääHÓ{ä6Ê ÓxäNJ
xäÉÈäâ xäÉÈäâ "
n n n
£Ó6 {ÊÌÊÓäÊÊ
/ iÀVÕ«i
«ÕÌ «ÕÌ
,iÌÀ>Ã --,É-- ,i>ÞÊVÌ>VÌÊÕÌ«ÕÌ }Ì>Ê«ÕÌ
{ÊÌÊÓä ÕÌÊÀiÃÃÌÀÊÌ
ÃÃ `ÀÛi #ONTROL OUTPUT
ÕÌ«ÕÌ ÌiÀ>ÃÊLiÌÜiiÊÊÊÊÊ>`
ÕÌ«ÕÌ ÕÌ«ÕÌ i>ÌiÀÊVÕÀÀiÌÊ
n n n ,-*Ê«ÕÌ
`iÌiVÌÀÊ«ÕÌ
a+/%"+3C+%4#"K+b
<=
[^]++8U("#2)*+4122"4($12+G$)'#)-
input CT input
<Control output 2> 4 4
–
+ + +
Re-trans- 5
4~20mA DC 5
SSR/SSC 5
Relay contact
5
mission output drive output output
output – 6
– 6
– 6 6 <Control output 1>
+ + +
Re-trans- 5
4~20mA DC 5
SSR/SSC 5
Relay contact
5
mission output drive output – output
output – – 6 6 6 <Control output 1>
6
PXR5 Process alarm output Common 7 31 31
+ 31
+
4~20mA DC SSR/SSC
PXR9 Relay
output drive output
contact
+ 5 5
Process alarm output 1 8 32
output
32
– 32
–
R-SP input CT input Process alarm output 2 9 33
6 6 Resistance bulb
– input
Heater burnout alarm output 3 10 34
or process alarm output 3 A (Note 1)
24V DC
+ 11 Power supply 11 35
+ B + 250Ω
24V AC 100~240V AC B
50/60Hz
–
12 50/60Hz 12 36
– –
Thermocouple 1~5V DC 4~20mA DC
input <Process variable input>
● E$(?+41--/2$4)($12+ + 1
Communication
++++L/24($12 RS-485 – 2
+ 3 3 Note 1: Mount supplied resistor to
R-SP terminals between 35 and 36
input CT input 3
4 4 Digital input
–
<Control output 2> 4
+ + +
Re-trans- 5
4~20mA DC 5
SSR/SSC 5 5
mission Relay contact
– output – drive output – output <Control output 1>
output 6 6 6 6
567> 567@
567A R !^=
R
X X
M M
9 9
U U
567B > >
R [ RM R [ RM [ MR !^=
[ MR
X Z R9 MX Z MX
>?X
X Z R9 Z
567C
>?X
M V RU M V RU V MM V MM
RY RR RX RM R9 RU R> R[ RZ
9 RY R> 9 RY R> RY M9 RY M9
>?X
>?X
U RR R[ U RR R[ RR MU RR MU
> RX RZ > RX RZ RX M> RX M>
R X M 9 U > [ Z V
<C
567 3$4#1+012(#1**"#+567
[A]++567B+!14Q"(+(H."+1#G"#$2'+41G"
B[×B[--+!$`"+ B > ^ A [ @ <D << <= <C
!14Q"(+(H." 567 4 S 1 0
<B
[[]++!."4$L$4)($12%
N+e"2"#)*+%."4$L$4)($12% N+:."#)($12+)2G+G$%.*)H+%"4($12
0OWER SUPPLY 6 TO 6 !# (Z 0ARAMETER SETTING $IGITAL SETTING BY KEYS
VOLTAGE OR 6 ¢ !# (Z 6 ¢ $# METHOD 7ITH KEY LOCK FUNCTION
0OWER 7HEN USING 6 !# 6! OR LESS $ISPLAY 0ROCESS VALUESET VALUE )NDEPENDENT DISPLAY
CONSUMPTION 7HEN USING 6 !# 6! OR LESS DIGITS SEGMENT ,%$
7HEN USING 6 !#$# 6! 3TATUS DISPLAY ,%$ #ONTROL OUTPUT PROCESS ALARM OUTPUT
)NSULATION RESISTANCE -NJ OR MORE 6 $# 3ETTING ACCURACY OR LESS OF MEASURING RANGE
$IELECTRIC STRENGTH 0OWER SUPPLY GROUND 6 !# FOR MIN )NDICATION ACCURACY 4HERMOCOUPLE ¢ OF MEASURING RANGE
0OWER SUPPLY OTHERS 6 !# FOR MIN AT ª# ¢ DIGIT ¢ª#
'ROUND RELAY OUTPUT 6 !# FOR MIN &OR THERMOCOUPLE 2 AT TO ª#
'ROUND ALARM OUTPUT 6 !# FOR MIN ¢ OF MEASURING RANGE ¢ DIGIT ¢ª#
/THERS 6 !# FOR MIN &OR THERMOCOUPLE " AT TO ª#
)NPUT IMPEDANCE 4HERMOCOUPLE -NJ OR MORE ¢ OF MEASURING RANGE ¢ DIGIT ¢ª#
6OLTAGE KNJ OR MORE 2ESISTANCE BULB VOLTAGECURRENT
#URRENT NJ EXTERNAL RESISTOR ¢ OF MEASURING RANGE ¢ DIGIT
!LLOWABLE SIGNAL 4HERMOCOUPLE NJ OR LESS
SOURCE RESISTANCE 6OLTAGE KNJ OR LESS N+I*)#-+M1.($12N
!LLOWABLE WIRING 2ESISTANCE BULB NJ OR LESS PER WIRE !LARM KIND !BSOLUTE ALARM DEVIATION ALARM ZONE ALARM
RESISTANCE WITH UPPER AND LOWER LIMITS FOR EACH
2EFERENCE JUNCTION ¢ª# AT ª# (OLD FUNCTION AVAILABLE 3EE THE FIGURE BELOW
COMPENSATION ACCURACY !LARM LATCH %XCITATIONNON EXCITATION
)NPUT VALUE CORRECTION ¢ OF MEASURING RANGE SELECTING FUNCTION PROVIDED
3ET VALUE CORRECTION ¢ OF MEASURING RANGE !LARM /. DELAY $ELAY SETTING TO SEC SETTABLE IN SEC
)NPUT FILTER TO SEC SETTABLE IN SEC STEPS STEPS
FIRST ORDER LAG FILTER 0ROCESS ALARM 2ELAY CONTACT 3034 CONTACT 6 !# 6 $#
.OISE REDUCTION RATIO .ORMAL MODE NOISE (Z D" OR MORE OUTPUT ! RESISTIVE LOAD
#OMMON MODE NOISE (Z D" OR MORE -ECHANICAL LIFE MILLION OPERATIONS NO LOAD
%LECTRICAL LIFE OPERATIONS RATED LOAD
N+012(#1*+L/24($12+1L+%()2G)#G+(H." -INIMUM SWITCHING CURRENT M! 6 $#
#ONTROL ACTION 0)$ CONTROL WITH AUTO TUNING SELF TUNING -!8 POINTS OUTPUT CYCLE SEC
&UZZY CONTROL WITH AUTO TUNING
3ELF TUNING N+:(?"#+L/24($12%
0ROPORTIONAL BAND 0 TO OF MEASURING RANGE SETTABLE IN 0ARAMETER MASK 0ARAMETER DISPLAY IS DISABLED BY SOFTWARE
STEP FUNCTION
)NTEGRAL TIME ) TO SEC SETTABLE IN SEC STEP 2AMPSOAK PROGRAM PATTERN OF STEPS EACH OR
$IFFERENTIAL TIME $ TO SEC SETTABLE IN SEC STEP FUNCTION OPTION PROGRAM PATTERN STEPS
/NOFF ACTION IF 0 0ROPORTIONAL ACTION WHEN ) $ $IGITAL INPUT ALLOWS TO STARTRESET THE ACTION
0ROPORTIONAL CYCLE TO SEC SETTABLE IN SEC STEP
/NLY FOR RELAY CONTACT OUTPUT OR 33233# DRIVE N+51K"#+L)$*/#"+.#14"%%$2'
OUTPUT -EMORY PROTECTION (ELD BY NON VOLATILE MEMORY
(YSTERESIS WIDTH TO OF MEASURING RANGE
&OR /NOFF ACTION ONLY N+!"*LZ4?"4Q
!NTI RESET WINDUP TO OF MEASURING RANGE -ETHOD 0ROGRAM ERROR SUPERVISION BY WATCHDOG TIMER
!UTOMATICALLY VALIDATED AT AUTO TUNING
)NPUT SAMPLING CYCLE SEC N+:."#)($12+)2G+%(1#)'"+412G$($12%
#ONTROL CYCLE SEC !MBIENT OPERATING ª# TO ª#
TEMPERATURE )N LOW TEMPERATURE ENVIRONMENT START UP
N+O2./(+%"4($12 TIME MAY VARY IN POWER ACTIVATION
)NPUT SIGNAL 4HERMOCOUPLE * + 2 " 3 4 % . 0,** !MBIENT OPERATING ,ESS THAN 2( NO CONDENSATION
2ESISTANCE BULB 0T HUMIDITY
6OLTAGE CURRENT TO 6 $# TO M! $# 3TORAGE TEMPERATURE ª# TO ª#
!PPLY CURRENT INPUT AFTER CONNECTING THE
FURNISHED NJ RESISTOR TO INPUT TERMINAL N+!(#/4(/#"
-EASURING RANGE 3EE MEASURING RANGE TABLE 4ABLE -OUNTING METHOD 0ANEL FLUSH MOUNTING $). RAIL MOUNTING
"URNOUT &OR THERMOCOUPLE OR RESISTANCE BULB INPUT -OUNTING SOCKET IS REQUIRED FOR MOUNTING
#ONTROL OUTPUT UPPERLOWER ARE SELECTABLE $). RAIL
%XTERNAL TERMINAL PINS OR PINS TERMINALS
N+:/(./(+%"4($12+1L+%()2G)#G+(H."+M412(#1*+1/(./(+<N
3OCKET IS REQUIRED FOR WIRING SEPARATELY
#ONTROL OUTPUT 3ELECT ONE AS FOLLOWS #ASE MATERIAL 0LASTIC
2ELAY CONTACT 30$4 CONTACT NON COMBUSTIBLE GRADE 5,6 EQUIVALENT
6 !#6 $# ! RESISTIVE LOAD $IMENSIONS MM
-ECHANICAL LIFE MILLION OPERATIONS NO LOAD 7EIGHT !PPROX G
%LECTRICAL LIFE OPERATIONS RATED LOAD 0ROTECTIVE &RONT WATERPROOF STRUCTURE .%-!8
-INIMUM SWITCHING CURRENT M! 6 $# STRUCTURE )%# STANDARD )0 EQUIVALENT
332 33# DRIVE 6OLTAGE PULSE WHEN MOUNTED ON PANEL WITH OUR GENUINE
/. TO 6 $# PACKING 7ATERPROOF FEATURE UNAVAILABLE
/&& 6 $# OR LESS IN CLOSE MOUNTING OF MULTIPLE UNITS
-AX CURRENT M! OR LESS 2EAR CASE )%# )0
TO M! $# !LLOWABLE LOAD RESISTANCE NJ /UTER CASING "LACK FRONT FRAME CASE
OR LESS
<>
567 3$4#1+012(#1**"#+567
[[]++!."4$L$4)($12%
,)P*"+<++3")%/#$2'+#)2'"+()P*"
Group input signal measuring range(°C) measuring range(°F)
Resistance bulb Pt100 -150 to 850 -238 to 1562
Thermocouple J 0 to 800 32 to 1472
K 0 to 1200 32 to 2192
R 0 to 1600 32 to 2912
B 0 to 1800 32 to 3272
I
S 0 to 1600 32 to 2912
T -150 to 400 -238 to 752
E -150 to 800 -238 to 1472
N 0 to 1300 32 to 2372
PL II 0 to 1300 32 to 2372
DC voltage 1 to 5V scaling range -1999 to 9999
II
DC current 4 to 20mA
Note 1: For current input connect the supplied 250Ω resister at the input
terminal.
Note 2: Setting cannot be changed to a different group.
Note 3: When the measuring range exceeds 1000°C (1832°F), decimal
point cannot be used.
■+!41."+1L+G"*$R"#H
Scope of delivery Controller, panel mounting bracket,
watertight packing, instruction manual (as
ordered), socket (as ordered), 250Ω resistor
(for current input)
■+O2%/*)($12+P*14Q+G$)'#)-
<^
[@]++:/(*$2"+)2G+5)2"*+0/(1/(+&$-"2%$12%
Type Outline Panel cut
Mounting frame
93.7
+0.5
79.5 45 0
84.7 Side stick mounting (n units)
Panel 70.5
9 +0.5
(48 x N-3) 0
48 1
+0.5
45 0
73min.
PXR4
+0.5
Socket C1 C2 AL1 AL2 AL3
45 0
type PV
44.7
57
48
SV
63min.
SEL
PXR-4
[<D]++!14Q"(+:/(*$2"+&$)'#)-+M/2$(;+--N
Without alarm
TP48SB TYPE (FOR PANEL MOUNTING) TP48X TYPE (FOR RAIL MOUNTING)
TERMINAL SCREW
M3.5×8 5.5
φ27 TERMINAL SCREW
M3.5×8
6 5 4 3
3 4 5 6
35.4
45
70
2 1 8 7
2-φ4.5 7 8 1 2
7 HOLE
45 5 17
7.8 4
50
20.3 MAX.
40±0.2 2-φ4.5
MOUNTING HOLE
With alarm
TP411X TYPE (FOR RAIL MOUNTING) TP411SBA TYPE (FOR PANEL MOUNTING)
TERMINAL SCREW
M3.5×11 4.5
TERMINAL SCREW
φ27 M3.5×11
5
8 7 6 4 5
6 7 8
4
25.6
35.4
45
70
3 9
1 11
2-φ4.5 9 11 1 3
HOLE 2 10
10 2 45 4.5 16.3 6.2 7
7.8
4
50
31.2 MAX.
40±0.2 2-φ4.5
MOUNTING HOLE
<A
567 3$4#1+012(#1**"#+567
[<<]++8U("#2)*+4122"4($12+G$)'#)-
M<N+E$(?+)*)#-+L/24($12%+++++<<Z.$2+%14Q"(
E?"2+41-.)($P*"+K$(?+56EB\56gB\56SB+(?"#-141/.*"+$2./(+("#-$2)*
7HEN EITHER ONE OF THE FOLLOWING IS SELECTED FOR THE TH DIGIT OF THE CODE SYMBOLS h4 v h2 v h7 v h!v AND h"v
.OTE THAT THE TERMINAL LAYOUT OF THE RESISTANCE BULB INPUT TYPE DIFFERS FROM THAT OF 08708:086
#/.42/, /54054
E?"2+41-.)($P*"+K$(?+56EB\56gB\56SB+#"%$%()24"+P/*P+$2./(+("#-$2)*
7HEN EITHER ONE OF THE FOLLOWING IS SELECTED FOR THE TH DIGIT OF THE CODE SYMBOLS h.v AND h3v
.OTE THAT THE TERMINAL LAYOUT OF THE THERMOCOUPLE INPUT TYPE DIFFERS FROM THAT OF 08708:086
#/.42/, /54054
!,!2- /54054
"
!,!2- /54054
"
!
4#
24$ 0/7%2
!# TO 6
!#$# 6
./4% 5SE THE NJ RESISTANCE ACCESSORY (Z
M=N+E$(?1/(+)*)#-+L/24($12%+++++[Z.$2+%14Q"(
E?"2+41-.)($P*"+K$(?+56EB\56gB\56SB+(?"#-141/.*"+$2./(+("#-$2)*
7HEN EITHER ONE OF THE FOLLOWING IS SELECTED FOR THE TH DIGIT OF THE CODE SYMBOLS h4 v h2 v h7 v h!v AND h"v
.OTE THAT THE TERMINAL LAYOUT OF THE RESISTANCE BULB INPUT TYPE DIFFERS FROM THAT OF 08708:086
#/.42/, /54054
!
./4%
"
NJ
"
$# TO M! $# TO 6 24$ 4# 0/7%2
!# TO 6
!#$# 6
(Z
E?"2+41-.)($P*"+K$(?+56EB\56gB\56SB+#"%$%()24"+P/*P+$2./(+("#-$2)*
7HEN EITHER ONE OF THE FOLLOWING IS SELECTED FOR THE TH DIGIT OF THE CODE SYMBOLS h.v AND h3v
.OTE THAT THE TERMINAL LAYOUT OF THE THERMOCOUPLE INPUT TYPE DIFFERS FROM THAT OF 08708:086
#/.42/, /54054
"
"
!
24$ 0/7%2
4#
!# TO 6
!#$# 6
./4% 5SE THE NJ RESISTANCE ACCESSORY (Z
<[
[<=]++J/24($12%
J/24($12D 3)2/)*+:."#)($12
This function is selectable operation mode either "Auto" or "Manual" ]")($2'+\+411*$2'+412(#1*+M1.($12N
operation by change the parameter. By a single controller both heating and cooling control output are obtained.
MV output value is changeable by manual operation on Manual mode. (Both control outputs 1 and 2 are used.)
• Operation mode is stored while power down.
• Changeover method: Auto $ Manual: Balanceless bump less /UTPUT
Manual $ Auto: Balance bump less (EATING SIDE #OOLING SIDE
• MV setting value resolution: 1%(Settable by front key)
• MV setting range: -3~103% #OEFFICIENT
• Auto-tuning and Self-tuning are not available while manual operation
#OEFFICIENT
mode.
#OEFFICIENT
$EVIATION $EVIATION
/VERLAP
BAND $EAD BAND ÌiÊ£\Ê ÕÀ}Ê i>Ì}ÉV}ÊVÌÀ]Ê
Ê Ì iÊ* Ê>ÕÌÊÌÕ}ÊV>ÌÊLiÊÕÃi`°
ÌiÊÓ\ʸ¸Ê>`ʸ ¸ÊÃiÌÌ}ÃÊ>ÀiÊVÊ
/VERSHOOT 2ESPONSE TO /VERSHOOT 2ESPONSE TO 3ET VALUE 36 Ê ÌÊ i>Ì}Ê>`ÊV}]Ê>`Ê
DISTURBNCES DISTURBNCES Ê V>ÌÊLiÊÃiiVÌi`Ê`Û`Õ>Þ°
51$2( /.
/. /.
:2\1LL+)4($12+?H%("#"%$%+%"(($2' #ONTROL
OUTPUT
In on/off control, output turns on/off with respect to the set value. /&& /&&
/&&
Therefore, output would change frequently in response to a slight change 0)$ CONTROL
in the temperature. This might shorten the service life of the output relay /. /&& ACTION
36n
/. 150˚C and a hysteresis (HYS) of 10. When
the set value is adjusted to 40˚C, the heater
turns off at 45˚C and turns on at 35˚C. 06 PROCESS VALUE
Example 2) For turning off the heater at /.
/. /.
/&& 45˚C in the figure at left, parameter [SVOF]
should be set at "-5." Then, the heater
#ONTROL
OUTPUT
/&& /&&
turns off at 45˚C and turns on at 35˚C. /&&
4EMPERATURE (The above action is effective when the 0)$ CONTROL
/. /&& ACTION
ONOFF parameter is set at OFF.)
51$2( !"*LZ(/2$2'+L/24($12
0?)2'"1R"#+1L+1/(./(+)4($12
At power on, changing a set value or during external disturbance, tuning is
Direct action or reverse action is settable by parameter [P-n1].
made automatically so that the PID parameters are reoptimized.
#ONTROL INPUT
#ONTROL INPUT
%XTERNAL
DISTURBANCE /VERSHOOT %XTER
,OW 3ET VALUE 36 (IGH ,OW 3ET VALUE 36 (IGH 3ET VALUE CHANGE
DISTUR
s 2EVERSE ACTION s $IRECT ACTION
7HEN PROCESS VALUE 06 DECREASES 7HEN PROCESS VALUE 06 INCREASES
BELOW THE SET VALUE 36 OUTPUT CHANGES ABOVE THE SET VALUE 36 OUTPUT CHANGES 0OWER ON
SO THAT CONTROL INPUT INCREASES
Note: For some objects to control, PID
SO THAT CONTROL INPUT INCREASES
values could not be optimized.
<@
567 3$4#1+012(#1**"#+567
[<=]++J/24($12%
J/24($12C I*)#-+M1.($12N
+IND OF ALARM AND ALARM TYPE CODE !LARM CODE FOR SETTING VALUE POINTS
!,- !,- !,- !LARM TYPE /PERATION FIGURE !,- !,- !,- !LARM TYPE /PERATION FIGURE
5PPER 5PPER AND
.O ALARM 06 LOWER LIMITS 06
AND !N , !N (
LOWER ABSOLUTE VALUE
!BSOLUTE 5PPER LIMIT LIMITS 5PPER AND LOWER !N , !N (
06
VALUE ABSOLUTE VALUE !,N ALARM LIMITS DEVIATION 36
06
ALARM
5PPER LIMIT !N ,
,OWER LIMIT
06 ABSOLUTE VALUE AND 06
ABSOLUTE VALUE !,N 36 !N (
LOWER LIMIT DEVIATION
5PPER LIMIT 5PPER LIMIT !N (
ABSOLUTE VALUE 06 DEVIATION AND LOWER 06
!,N !N , 36
WITH HOLD LIMIT ABSOLUTE VALUE
,OWER LIMIT 5PPER AND LOWER
ABSOLUTE VALUE 06 LIMITS ABSOLUTE !N , !N (
06
!,N
WITH HOLD VALUE WITH HOLD
$EVIATION !,N 5PPER AND LOWER !N , !N (
5PPER LIMIT
VALUE 06 LIMIT DEVIATION 06
DEVIATION 36
ALARM
36 WITH HOLD
!,N 5PPER LIMIT ABSOLUTE !N ,
,OWER LIMIT
06 VALUE AND LOWER LIMIT 06
DEVIATION 36 !N (
36 DEVIATION WITH HOLD
!,N !,N 5PPER LIMIT DEVIATION !N (
5PPER AND LOWER
06 AND LOWER LIMIT ABSOLUTE 06
LIMITS DEVIATION !N , 36
36 VALUE WITH HOLD
!,N 2ANGE 2ANGE UPPER
5PPER LIMIT
06 ALARM AND LOWER LIMITS 06
DEVIATION WITH HOLD !N , !N (
36 ABSOLUTE VALUE
!,N 2ANGE UPPER !N , !N (
,OWER LIMIT
06 AND LOWER
DEVIATION WITH HOLD 06
36 LIMITS DEVIATION 36
5PPER AND LOWER !,N !,N 2ANGE UPPER LIMIT ABSOLUTE !N ,
LIMITS DEVIATION 06 VALUE AND LOWER 06
WITH HOLD 36 LIMIT DEVIATION 36 !N (
2ANGE 2ANGE UPPER AND !,N !,N 2ANGE UPPER LIMIT DEVIATION !N (
LOWER LIMITS DEVIATION AND LOWER LIMIT
ALARM !,- INDEPEN DENT OPERATION 06 06
36 ABSOLUTE VALUE !N , 36
2ANGE UPPER 2ANGE UPPER AND
AND LOWER LIMITS 06 LOWER LIMITS ABSOLUTE 06
!, !, !N , !N (
ABSOLUTE VALUE VALUE WITH HOLD
2ANGE UPPER AND !, !, 2ANGE UPPER AND !N , !N (
LOWER LIMITS LOWER LIMITS
06 06
DEVIATION 36 DEVIATION WITH HOLD 36
2ANGE UPPER LIMIT !, 2ANGE UPPER LIMIT ABSOLUTE !N ,
ABSOLUTE VALUE AND VALUE AND LOWER LIMIT 06
06
LOWER LIMIT DEVIATION 36 !, DEVIATION WITH HOLD 36 !N (
4IMER CODE
!,- !,- !,- !LARM TYPE /PERATION FIGURE J/24($12B ]")("#+P/#21/(+)*)#-+M1.($12N
4IMER
/. DELAY $)
• Heater burnout is detected then the alarm is emitted immediately.
!,-
TIMER
D,9N • Separate type current trasformer(CT)specified by Fuji should be used.
• Alarm action point can be set by front panel keys.
/&& DELAY $)
• Detection is made only on a single-phase heater.
TIMER !,-
D,9N • This function cannot be used when controlling a heater with thyrister
$)
phase angle control system.
/./&& !,-
DELAY TIMER
D,9N D,9N "##Example of the connection of the heater burnout alarm
)F CHANGE THE KINDS OF PARAMETER PLEASE POWER /./&& 082 (type PXR5, PXR9)
-AGNET SWITCH
#URRENT
TRANSFORMER
#4
0OWER /. 0OWER /&& 0OWER /.
4HERMOCOUPLE
ON ON
5PPER,OWER LIMITS OFF OFF OFF
DEVIATION ALARM
5PPER,OWER LIMITS ON (EATER
OFF OFF
DEVIATION ALARM
WITH HOLD %LECTRIC FURNACE
Rerer to 17page for CT
=D
[<=]++J/24($12%
J/24($12> 5)#)-"("#+-)%Q+L/24($12 J/24($12[ &$'$()*+$2./(+M1.($12N
This instrument provides a function (parameter mask function) to mask External digital input allows one of the following functions.
(conceal) the display of individual parameters. ● Change the set value (Front SV, SV1-3)
To effect parameter mask(non-display)or non- mask (display),appropriate ● Start/stop the control action
values should be set to DSP1-13. ● Start/reset the ramp/soak
Example of setting to (DSP1-13) ● Start/stop the auto tuning
● Cancel the alarm latch
(a) To mask parameter P Parameter DSP
1) Check DSP value for Preferring to ● Start the incorporated timer
P DSP3-2
parameter table I DSP3-4 * The above functions can be combined when two digital inputs are used.
2) Add 2 to the value set to DSP3. D DSP3-8
$IGITAL INPUT
J/24($12^ 7)-.+%1)Q+L/24($12+M1.($12N /.
/&& /&&
Function of automatically changing the set point value with the elapsing of
D,9N
time, in accordance with the preset pattern, as shown below.This function
/. DELAY TIMER /.
is capable of programming a 2 program pattern of 4 steps each, or 1
program parttern × 8 steps. /&& /&&
D,9N
/&& DELAY TIMER /.
36 /&& /&&
3ET VALUE
36
D,9N D,9N
36
36
/./&& /.
36 DELAY TIMER
36 /&& /&&
36
36
/ ÃÊvÕVÌÊÃÊ>Û>>LiÊÞÊÜÌ Ê`}Ì>Ê«ÕÌÊ«Ì®°
4IME
J/24($12<D I2)*1'+7"Z(#)2%-$%%$12+M1.($12N+
● Output signal : 4 to 20 mA DC
J/24($12A 7!ZB[>+01--/2$4)($12+L/24($12+M1.($12N ● Kind of output : Any one of process value (PV), set value (SV),
With RS-485 (Modbus protocol) interface, a connection with computer, manipulated output value (MV) and process variable - set value
touch panel or PLC is allowed. (DV) (setting by front keys)
23 Oil
5P TO CONTROLLERS AC power
CONNECTED regulator (APR) Heater
J/24($12<< 7"-1("+!S+$2./(+M1.($12N
● SV (set value) can be selected with signals from outside.
● SV input signal: 1 to 5V DC
567C 567B 567> 567A 567@
@#FG#(1#&
Either communication protocol below is selectable. Selection should be @#)$)#3-#&/)G&#$B@JH
made according to system configuration.
R$)'$UJ$N]
1) ModbusTM RTU mode:
An open protocol generally used in particular outside Japan. In case
the host side supports this protocol, connection is allowed without a
program. ]'()&'.$ !#3-#&/)G&#$
2) Z-ASCII (Fuji's original) 'G)-G) +(-G)
Because transmission code is ASCII, programming with PLC, etc. is
simple.
]#..$7 ]#..$T ]#..$] ]#..$N ]#..$5
!"#$)#3-#&/)G&#$'%$#/1"$1#..$+,$,#)$A0$)"#$,#FG#(1#&?$
=<
567 3$4#1+012(#1**"#+567
[<C]++!"2%1#+L)/*(+1."#)($12
i ,?"#-141/.*"
Condition Display Control output
ON or more than 20mA (Note)
Break
OFF or less than 4mA
i 7"%$%()24"+P/*P+$2./(
Condition Display Control output
i <Z>S+&0
OFF or less than 4mA (Note)
Break
ON or more than 20mA
Short
circuit
i BZ=D-I+&0
Over-range OFF or less than 4mA (Note)
(Note) Control output changes in operation according to the designation of burnout direction (parameter, “P-n1”).
In case of Manual Mode, control output signal is MV output value.
]")("#+P/#21/(+)*)#-+4/##"2(+G"("4(1#+M0,N
3PECIFICATION &OR ! 3PECIFICATION &OR !
4YPE #4, 3 4YPE #4, 3 (
#4, 3 IS PRINTED ON
COMMODITY AS TYPE
- DEPTH
==
[<B]++5)#)-"("#+()P*"
5)#)-"("#+()P*"+567+ b]
]R$$$$$$]X$$$$$7\R$$$$7\X$$$$7\M
^-#&&/)+'(c@)/(*A0$ =J
3'*#$*+,-./0
@J
Parameters for the PXR are classified under three blocks 082
3%,
3%,
=&#,,$%'&$
3%,
=&#,,$%'&$
3%,
=&#,,$%'&$
according to the frequency of use. The parameters of the /A'G)$R$,#1? /A'G)$M$,#1? /A'G)$U$,#1?
i 5)#)-"("#%+1L+(?"+L$#%(+P*14Q+
0ARAMETER 6ALUE PRIOR 5SERS 0ARAMETER
0ARAMETER NAME $ESCRIPTION 3ETTING RANGE
DISPLAY SYMBOL TO DELIVERY SET VALUE MASK $30
!UTO-ANUAL ON -ANUAL MODE
-!N5 3WITCHES BETWEEN !UTO AND -ANUAL MODE /&& D30
SETTING O&& !UTO MODE
ON #ONTROL STANDBY
3WITCHES BETWEEN 25. AND 3TANDBY
34BY 3TANDBY SETTING /UTPUT /&& !LARM /&& /&& D30
FOR CONTROL
O&& #ONTROL 25.
2EMOTE,OCAL 3WITCHES BETWEEN 2EMOTE AND ,OCAL R%- 2EMOTE
#-OD ,O#, D30
SETTING OPERATIONS ,O#, ,OCAL
O&& 3TOP
2AMP SOAK 3WITCHES BETWEEN 3TART 3TOP R5N 3TART
0RO' /&& D30
CONTROL AND (OLD FOR RAMP SOAK CONTROL (,D (OLD
!LARM LATCH +EEPS THE ALARM LATCH
,!#( #ANCELS THE ALARM LATCH D30
CANCEL /PENS UP THE ALARM LATCH
/&& 2ESETS THE AUTO TUNING OR
DOES NOT USE IT
5SED FOR SETTING THE CONSTANTS FOR /. 0ERFORMS THE AUTO TUNING
!4 !UTO TUNING D30
AND BY AUTO TUNING IN THE 36 STANDARD TYPE
/. 0ERFORMS THE AUTO TUNING IN
LOW 06 TYPE 36 VALUE &3
4- 4IMER DISPLAY $ISPLAYS THE REMAINING TIME OF TIMER 5NIT SECONDS D30
4- 4IMER DISPLAY $ISPLAYS THE REMAINING TIME OF TIMER 5NIT SECONDS D30
4- 4IMER DISPLAY $ISPLAYS THE REMAINING TIME OF TIMER 5NIT SECONDS D30
3ET VALUE OF 3ETS THE VALUE AT WHICH 4YPe TO
!, 7HEN THE ALARM TYPE IS ABSOLUTE D30
ALARM ALARM IS DETECTED 0OSSIBLE TO SET UP WITHIN
INPUT RANGE VALUE TO &3
,OWER LIMIT VALUE 3ETS THE LOWER LIMIT VALUE
! , !, ! ( ! , D30
OF ALARM AT WHICH ALARM IS DETECTED
TO TO TO 7HEN THE ALARM TYPE IS DEVIATION
5PPER LIMIT VALUE 3ETS THE UPPER LIMIT VALUE !, ! ( ! , TO &3
! ( D30
OF ALARM AT WHICH ALARM IS DETECTED
3ET VALUE OF 3ETS THE VALUE DURING WHICH TO
!, 7HEN THE ALARM TYPE IS ABSOLUTE D30
ALARM ALARM IS DETECTED
VALUE TO &3
,OWER LIMIT VALUE 3ETS THE LOWER LIMIT VALUE
! , D30
OF ALARM AT WHICH ALARM IS DETECTED 7HEN THE ALARM TYPE IS DEVIATION
5PPER LIMIT VALUE TO
! (
3ETS THE UPPER LIMIT VALUE
TO &3 D30
OF ALARM AT WHICH ALARM IS DETECTED
3ET VALUE OF 3ETS THE VALUE AT WHICH
!, 7HEN THE ALARM TYPE IS ABSOLUTE D30
ALARM ALARM IS DETECTED
TO VALUE TO &3
,OWER LIMIT VALUE 3ETS THE LOWER LIMIT VALUE
! , D30
OF ALARM AT WHICH ALARM IS DETECTED
7HEN THE ALARM TYPE IS DEVIATION
5PPER LIMIT VALUE 3ETS THE UPPER LIMIT VALUE 3ETTING ENABLE TO &3
! ( 3ETTING DISABLE D30
OF ALARM AT WHICH ALARM IS DETECTED
3ETTING OF KEY LOCK STATUS
!LL PARAMETERS 36
,O# &RONT KEY #OMM &RONT KEY #OMM
UNICATION UNICATION
,O# +EY LOCK D30
3ETTING ENABLE 3ETTING DISABLE
=C
567 3$4#1+012(#1**"#+567
[<B]++5)#)-"("#+()P*"
5)#)-"("#+()P*"+567+
i 5)#)-"("#%+1L+(?"+%"412G+P*14Q+
0ARAMETER 6ALUE PRIOR 5SERS 0ARAMETER
0ARAMETER NAME $ESCRIPTION 3ETTING RANGE
DISPLAY SYMBOL TO DELIVERY SET VALUE MASK $30
0ROPORTIONAL BAND 3ET TO TO SELECT THE /./&& CONTROL TO
0 D30
4WO POSITION CONTROL
I )NTEGRAL TIME )NTEGRATION /&& AT TO SECONDS D30
D $IFFERENTIONAL TIME $IFFERENTIATION /&& AT TO SECONDS D30
(YSTERESIS RANGE
(93 3ETS THE HYSTERESIS FOR /./&& CONTROL TO &3 D30
FOR /./&& CONTROL
#OOLING SIDE !UTOMATICALLY SET BY AUTO TUNING FUNCTION
#OO, PROPORTIONAL 3ELECTING SWITCHES TO COOLING SIDE /./&& TO D30
BAND COEFFICIENT OPERATION
DB $EAD BAND 3HIFTS THE COOLING SIDE OUTPUT VALUE TO D30
!R !NTI RESET WINDUP !UTOMATICALLY SET BY AUTO TUNING FUNCTION TO &3 D30
Note 1: When a customer does not specify the settings while ordering, the following settings are selected as factory defaults.
Thermocouple input : Thermocouple K Measured range: 0 to 400°C
Resistance bulb input : Measured range: 0 to 150°C
Voltage/Current input : Scaling: 0 to 100%
=B
5)#)-"("#+()P*"+567+
i 5)#)-"("#%+1L+(?"+%"412G+P*14Q+
0ARAMETER 6ALUE PRIOR 5SERS 0ARAMETER
0ARAMETER NAME $ESCRIPTION 3ETTING RANGE
DISPLAY SYMBOL TO DELIVERY SET VALUE MASK $30
3V ND TARGET 36 3ETS THE ND TARGET 36 OF RAMP SOAK OPERATION 7ITHIN THE 36 LIMIT &3 D30
ND RAMP
4-R 3ETS THE ND RAMP SEGMENT TIME TO HM D30
SEGMENT TIME
ND SOAK
4-3 3ETS THE ND SOAK SEGMENT TIME TO HM D30
SEGMENT TIME
3V RD TARGET 36 3ETS THE RD TARGET 36 OF RAMP SOAK OPERATION 7ITHIN THE 36 LIMIT &3 D30
RD RAMP
4-R 3ETS THE RD RAMP SEGMENT TIME TO HM D30
SEGMENT TIME
RD SOAK
4-3 3ETS THE RD SOAK SEGMENT TIME TO HM D30
SEGMENT TIME
3V TH TARGET 36 3ETS THE TH TARGET 36 OF RAMP SOAK OPERATION 7ITHIN THE 36 LIMIT &3 D30
TH RAMP
4-R 3ETS THE TH RAMP SEGMENT TIME TO HM D30
SEGMENT TIME
TH SOAK
4-3 3ETS THE TH SOAK SEGMENT TIME TO HM D30
SEGMENT TIME
3V TH TARGET 36 3ETS THE TH TARGET 36 OF RAMP SOAK OPERATION 7ITHIN THE 36 LIMIT &3 D30
TH RAMP
4-R 3ETS THE TH RAMP SEGMENT TIME TO HM D30
SEGMENT TIME
TH SOAK
4-3 SEGMENT TIME 3ETS THE TH SOAK SEGMENT TIME TO HM D30
3V TH TARGET 36 3ETS THE TH TARGET 36 OF RAMP SOAK OPERATION 7ITHIN THE 36 LIMIT &3 D30
TH RAMP
4-R 3ETS THE TH RAMP SEGMENT TIME TO HM D30
SEGMENT TIME
TH SOAK
4-3 3ETS THE TH SOAK SEGMENT TIME TO HM D30
SEGMENT TIME
3V TH TARGET 36 3ETS THE TH TARGET 36 OF RAMP SOAK OPERATION 7ITHIN THE 36 LIMIT &3 D30
TH RAMP
4-R 3ETS THE TH RAMP SEGMENT TIME TO HM D30
SEGMENT TIME
TH SOAK
4-3 3ETS THE TH SOAK SEGMENT TIME TO HM D30
SEGMENT TIME
3V TH TARGET 36 3ETS THE TH TARGET 36 OF RAMP SOAK OPERATION 7ITHIN THE 36 LIMIT &3 D30
TH RAMP
4-R 3ETS THE TH RAMP SEGMENT TIME TO HM D30
SEGMENT TIME
4-3 TH SOAK 3ETS THE TH SOAK SEGMENT TIME TO HM D30
SEGMENT TIME
-OD 2AMP SOAK MODE 3ELECTS THE POWER ON START REPEAT AND STANDBY TO D30
FUNCTIONS FOR RAMP SOAK OPERATIONS
i 5)#)-"("#%+1L+(?"+(?$#G+P*14Q+
0ARAMETER 6ALUE PRIOR 5SERS 0ARAMETER
0ARAMETER NAME $ESCRIPTION 3ETTING RANGE
DISPLAY SYMBOL TO DELIVERY SET VALUE MASK $30
0 N #ONTROL ACTION 3PECIFIES CONTROL ACTION AND OUTPUT AT THE TO D30
INPUT BURN OUT
36 3ETTING VALUE
3V , 3ETS THE LOWER LIMIT OF THE 36 TO &3 &3 D30
LOWER LIMITER
3V ( 36 3ETTING VALUE 3ETS THE UPPER LIMIT OF THE 36 TO &3 &3 D30
UPPER LIMITER
D,9 $ELAY TIME $ELAY TIME OR TIMER VALUE FOR ALARM RELAY TO SECONDS D30
D,9 $ELAY TIME $ELAY TIME OR TIMER VALUE FOR ALARM RELAY TO SECONDS D30
D,9 $ELAY TIME $ELAY TIME OR TIMER VALUE FOR ALARM RELAY TO SECONDS D30
#4 #URRENT TRANSE DISPLAY $ISPLAYS THE CURRENT DETECTOR INPUT VALUE FOR (" ALARM D30
=>
567 3$4#1+012(#1**"#+567
[<B]++5)#)-"("#+()P*"
5)#)-"("#+()P*"+567+
i 5)#)-"("#%+1L+(?"+(?$#G+P*14Q+
=/&/3#)#& J/.G#$-&+'& C,#&f, =/&/3#)#&$
=/&/3#)#&$(/3# N#,1&+-)+'( @#))+(E$&/(E#
*+,-./0$,03A'. )'$*#.+I#&0 ,#)$I/.G# 3/,D$N@=
ST$B@#)$I/.G#$'%$"#/)#&$ @#),$)"#$'-#&/)+'($I/.G#$)"/)$*#)#1),$)"#$ Y$)'$UY?Y7$B@#))+(E$)'$Y?Y7$)G&(,$
SA Y?Y *@=RY8Z
A&#/D$/./&3H$,#))+(E "#/)#&$A&#/D? '%%$)"#$ST$/./&3?H$
7R"e 7./&3$R$"0,)#&#,+, @#),$)"#$"0,)#&#,+,$&/(E#$'%$^4$/(*$^__$'%$/./&3$R? Y$)'$UYh_@ R *@=RY8R>
@#),$)"#$.+3+)$)0-#,$'%$'G)-G),$R$/(*$X$
=]C! ^G)-G)$.+3+)$)0-#, Y$)'$RU Y *@=RR8>9
BA&#/D+(E$)"#$.+3+)P$'&$3/+()/+(#*$2+)"+($)"#$.+3+)H?$
C,#&8*#%+(/A.#$g#&'$
7*dY @"+%),$)"#$g#&'$-'+()$'%$+(-G)$I/.G#? 8UY$)'$UYh_@ Y *@=RX8Z
/*`G,)3#()
C,#&8*#%+(/A.#$
7*d@ @"+%),$)"#$,-/($'%$+(-G)$I/.G#? 8UY$)'$UYh_@ Y *@=RX8R>
,-/($/*`G,)3#()
N<R$BN+E+)/.$+(-G)$RH$
*+8R @#),$)"#$N<R$'-#&/)+'(,? Y$)'$RX Y *@=RX8MX
'-#&/)+'(
N<X$BN+E+)/.$+(-G)$XH$
*+8X @#),$)"#$N<X$'-#&/)+'(,? Y$)'$RX Y *@=RX8>9
'-#&/)+'(
@#),$)"#$-/&+)0$%'&$1'33G(+1/)+'(?$ Y;$^**$-/&+)0$$$$$R;$5I#($-/&+)0
]'6 =/&+)0$,#))+(E Y *@=RM8R
B!"#$A/G*$&/)#$+,$%+K#*$/)$V>YYA-,?H X;$4'$-/&+)0
]'33G(+1/)+'($ @2+)1"#,$1'33G(+1/)+'($-&')'1'.$A#)2##($ Y;$W87]@ ** N#-#(*,$
=]'\ '($)"#$ *@=RM8X
-&')'1'.$,#))+(E 6'*AG,$/(*$7@]<<? R;$6'*AG,$BL!CH )0-#?
L#8)&/(,3+,,+'(
7'8! @#.#1)+(E$)&/(,3+,,+'($'G)-G)$)0-#? Y;$=J$c$R;$@J$c$X;$6J$c$M;$NJ Y *@=RM89
'G)-G)$)0-#
L#8)&/(,3+,,+'(
7'8\ @#))+(E$)&/(,3+,,+'($A/,#$,1/.#? 8RYY?Y$)'$RYY?Yh Y?Y *@=RM89
A/,#$,1/.#
L#8)&/(,3+,,+'(
7'8S @#))+(E$)&/(,3+,,+'($,-/($,1/.#? 8RYY?Y$)'$RYY?Yh RYY?Y *@=RM89
,-/($,1/.#
L#3')#$@J$+(-G)$
&56^ @"+%),$)"#$g#&'$-'+()$'%$+(-G)$I/.G#? 8UY$)'$UYh_@ Y *@=RM8R>
g#&'$/*`G,)3#()
L#3')#$@J$+(-G)$
&56@ @"+%),$)"#$,-/($-'+()$'%$)"#$+(-G)$I/.G#? 8UY$)'$UYh_@ Y *@=RM8R>
,-/($/*`G,)3#()
L#3')#$@J$+(-G)$ @#),$)"#$%+.)#&$1'(,)/()$'%$')#$@J$+(-G)$
&8*_ Y?Y$)'$VYY?YY$,#1'(*, Y?Y *@=RM8R>
%+.)#&$1'(,)/() I/.G#?
L#3')#$@J$+(-G)$
&@I N+,-./0,$)"#$+(-G)$I/.G#$'%$')#$@J$+(-G)? 8 8 *@=RM8R>
I/.G#$*+,-./0
*@=R
*@=V ^&*#&+(E
8
*=RY =/&/3#)#&$3/,D @#),$2"#)"#&$'&$(')$)'$*+,-./0$#/1"$-/&/3#)#&? Y$)'$XUU ,-#1+%+8
1/)+'(
*=RM
=^
383:
=A
5I!C &$'$()*+,?"#-1%()(+M(H.";5I!CN
&O9+=B✕ B[--+%$`" I2+)*)#-+%"(("#+K$(?+12\1LL+412()4(+1/(./(V+
31%(+%/$("G+L1#+G"("4($2'+1R"#?")(+$2+-)4?$2"%T+"Y/$.-"2(%T+"(4V
• Front panel having a DIN size of 24 x 48mm.
• Because thermocouples (5 types) and thermistors (0 to 100˚C) are connectable.
• Alarm set value and measured temperature value can be checked promptly using the
front keys.
• This thermostat is capable of issuing 2 relay contact outputs. Therefore, any output of
Upper/Lower limit pair, 2 upper limit and 2 lower limit can be selected.
• Mountable to a DIN rail using the DIN rail mounting adapter available at option.
With this adapter, also mountable to a wall.
!."4$L$4)($12% +O2./(+%$'2)*T+-")%/#)P*"+#)2'"+)2G+$2G$4)($12+)44/#)4H+
Item Specification M,)P*"+<N
Input Number of inputs: 1
)NPUT SIGNAL -EASURABLE -INIMUM )NDICATION
Input signal and measurable range: Refer to Table 1. RANGE # RESOLUTION ACCURACY
Allowable signal source resistance: Thermocouple input 100Ω max.
4HERMOCOUPLE * TO # #
Measurement cycle: 2 sec. or less
+ TO # #
Burnout function: Thermocouple input: UUU display
Thermistor input: LLL display
2 TO # #
(Upscale or downscale at burnout settable) 4 TO # #
Input impedance: Thermocouple input 1 MΩ or higher % TO # #
Input filter: 0 to 90 sec. (settable in 1 sec. steps) 4HERMISTOR 0" TO # #
Primary lag filter .OTE #ORRECT INDICATION IS NOT ENSURED WITHIN A RANGE FROM TO # FOR AN 2 TYPE
Input value compensation: Settable within ±10% of measurable range THERMOCOUPLE
.OTE 3WITCHING BETWEEN A THERMISTOR AND A THERMOCOUPLE IS NOT ALLOWED
Indication Indication means: LCD (without back light)
4HERMOCOUPLE INPUT TYPE CAN BE CHANGED BY FRONT KEY OPERATION
Value/parameter indication: 4 digits of 7 segments each
(However, at the 1st digit, only - or 1 is indicated within -999 to 1999.) I*)#-+(H."%+M,)P*"+=N+
Contents of indication: Measured value, alarm set value 1,
alarm set value 2, various parameters 7ITH
#ODE OF !LARM 3ET VALUE HOLDING 2ELAY !CTION DIAGRAM
ACTION
Each indicator of alarms 1 and 2, ˚C scale 0! DIRECTION NOTATION .OTE AT ALARM .OTE
Operation Number of keys: 3 keys, sheet type keys (embossed)
Alarm value setting resolution: 1˚C .O
n n n
Key lock function: (Change of setting can be inhibited.) ALARM
Accuracy Indication accuracy: Refer to Table 1.
5PPER !BSOLUTE 2ELAY
(However, error of a temperature sensor is not included.) .O
LIMIT VALUE EXCITATION
Reference contact compensation error: ±3˚C (at 23˚C)
Alarm Number of outputs: 1 or 2 (as specified in CODE SYMBOLS) ,OWER !BSOLUTE 2ELAY
output .O
Contact structure: 1a contact LIMIT VALUE EXCITATION
Alarm type: Refer to Table 2.
Contact capacity: 220 V AC/30 V DC, 2 A (resistance load) 5PPER !BSOLUTE 2ELAY
9ES
220 AC/30 DC, 1 A (inductive load) LIMIT VALUE EXCITATION
Mechanical life of contact: 20 million activations or more (100 activations/min.)
,OWER !BSOLUTE 2ELAY
Electrical life of contact: 100,000 activations or more (rated load) 9ES
LIMIT VALUE EXCITATION
Output resetting cycle: 2 sec. or less
Alarm value settable range: Settable within 0 to 100% of measurable range 5PPER !BSOLUTE 2ELAY NON
Hysteresis width settable range: 0 to 110% of measurable range .O
LIMIT VALUE EXCITATION
(settable in 1˚C steps)
Alarm action delay time: Settable within 1 to 120 sec. ,OWER !BSOLUTE .O 2ELAY NON
Power Power supply voltage: 100 V (–15%) to 240 V (+10%) AC LIMIT VALUE EXCITATION
supply 50/60 Hz (±10%)
5PPER !BSOLUTE 9ES 2ELAY NON
Power consumption: 3 VA max. (with 100 V AC), 6 VA max. (with 240 V AC)
LIMIT VALUE EXCITATION
Operating Ambient temperature: 0 to 50˚C
conditions Ambient humidity: 90% RH max. (condensation unallowable) ,OWER !BSOLUTE 2ELAY NON
Applicable UL, C-UL, CE mark. 9ES
LIMIT VALUE EXCITATION
standards
Body Mounting method: Panel flush mounting .OTE (OW TO READ ACTION
structure AREA ! RANGE IN WHICH !,- OR !,- IS INDICATED ON ,#$ AT THE FRONT
External dimensions (H x W x D): 24 x 48 x 85 mm
AREA ! RANGE IN WHICH ALARM RELAY IS EXCITED
Weight: Approx. 100 g POINT !LARM SET VALUE
Casing material: Plastic (corresponding to flame resistance grade UL94V-0) 4HE HORIZONTAL AXIS REPRESENTS MEASURED VALUES 06
Front protective structure: IP66 (corresponding to NEMA-4X) when using 06 PROCESS VALUE
Fuji's genuine front waterproof packing part .OTE 7HAT IS THE HOLD FUNCTION
External terminals: Plug-in type (for bar terminals) %VEN IF THE PROCESS VALUE IS 0ERIOD WHERE
WITHIN THE ALARM RANGE LOWER LIMIT
Finish color: Ivory ALARM IS OUTPUT
WHEN TURNING ON POWER THE 0OWER /. 0OWER /&& 0OWER /.
ALARM DOES NOT TURN ON
I*)#-+1/(./(+?H%("#"%$%+K$G(? IMMEDIATELY BUT ONLY AFTER IT
ON ON
OFF OFF OFF
,OWER LIMIT ALARM ON
LEAVES AND THEN RETURNS TO ,OWER LIMIT ALARM OFF OFF
THE ALARM RANGE WITH HOLD
!LARM OUTPUT HYSTERESIS WIDTH #
&O9+#)$*+-1/2($2'
!LARM OUTPUT
# /.
-OUNT 0!3
%XAMPLE !LARM SET VALUE #
!LARM OUTPUT HYSTERESIS WIDTH #
#ONNECT WIRES TO
0!3
=[
31G"* :/(*$2"+G$)'#)-+M/2$(;--N
)NPUT SIGNAL 4EMPERATURE SENSOR .UMBER OF ALARM -ODEL
4HERMOCOUPLE /PTION 0!3+9 Waterproof packing
0!3+! 1
4HERMISTOR 0ROVIDED 0!3(9 48
0!3(!
PV SET1 SET2
ALM1 ALM2
34.2
24
22
:.($12)*+$("-%
#ONTENTS -ODEL
$). RAIL MOUNTING ADAPTER ::0 #4+0
84
4 85
Mounting adapter
!"(($2'+)(+G"*$R"#H Panel (1 ≤ t ≤ 8)
-EASURABLE RANGE + THERMOCOUPLE INPUT TO #
4HERMISTOR INPUT TO #
!LARM SET VALUE + THERMOCOUPLE INPUT &OR POINT ALARM
UPPER LIMIT # 5)2"*+4/(1/(
+ THERMOCOUPLE INPUT &OR POINT ALARM
UPPER LIMIT # LOWER LIMIT ALARM #
4HERMISTOR INPUT &OR POINT ALARM &OR MOUNTING N UNITS &OR CLOSE MOUNTING
UPPER LIMIT # IN HORIZONTAL DIRECTION
4HERMISTOR INPUT &OR POINT ALARM 8 Nn
!LARM DELAY TIME SEC
-).
)NDICATION -EASURED VALUE
"URNOUT 5PSCALE AT BURNOUT
)NPUT FILTER SEC 4HIS MOUNTING DOES NOT MEET
.%-! 8)0 FRONT WATERPROOF
)NPUT VALUE COMPENSATION SPECIFICATION
.OTE 3WITCHING BETWEEN A THERMISTOR AND A THERMOCOUPLE IS NOT ALLOWED -). "ECAUSE THE PACKING CANNOT BE USED
.OTE 4HERMOCOUPLE INPUT TYPE CAN BE CHANGED BY FRONT KEY OPERATION IN HORIZONTALLY CLOSE MOUNTING
!41."+1L+G"*$R"#H
&O9+#)$*+-1/2($2'+)G).("#+M1.($12N
Thermostat unit, panel-mounting adapter,
front waterproof packing
Thermistor sensor added for thermistor input 52.4
I()4?"G+(?"#-$%(1#+%"2%1#
s !TTACHMENT FOR THERMISTOR INPUT THERMOSTAT PV SET1 SET2
45.4
ALM1 ALM2
M
4
36.8
PAS3...
MFD.
No.
-!8 !BOUT
j%)P*"+K$#$2'+-)("#$)*%
0122"4($12+G$)'#)-
s 7IRE 490% 3INGLE WIRE
'AUGE !7' MM TO !7' MM !7' TO !7'
3TRIP OFF LENGTH TO MM
n TO MM
s "AR TERMINAL
4HERMOCOUPLE !LARM OUTPUT !LARM OUTPUT 0OWER SUPPLY $IMENSION OF STRIP OFF CONDUCTOR SECTION X MM OR SMALLER
INPUT !# 6 ,ENGTH OF STRIP OFF CONDUCTOR SECTION TO MM
(Z
-!8
4HERMISTOR -!8 TO MM
=@
56 F$%(+1L+("-."#)(/#"+412(#1**"#%
!"#$"%
56+!"#$"%
0*)%%$L$4)($12 CZQ"H+(H."+K$(?+*)#'"+G$%.*)H
Standard type
Front view (size mm)
PXR5 PXR9
PXR7
PXR4
Waterproof type
PXR3
Pt100
J thermocouple
K thermocouple
R thermocouple
B thermocouple
Input signal
S thermocouple
T thermocouple
E thermocouple
N thermocouple
PL II thermocouple
1 to 5V DC
4 to 20mA DC (With resistor)
Output signal
Relay
For SSR/SSC drive
4 to 20mA DC
ON-OFF
Control method
PID
Auto tuning PID
Fuzzy
Self-tuning
Heating/cooling control
Indicating accuracy ±0.5% FS ±1digit ±1˚C
Communicating function (RS-485)
Re-transmission output in 4 to 20 mA DC
Timer function
Digital input
Ramp soak function (8 ramp/soak)
Alarm output
Heater burnout alarm (current output unavailable) (Unavailable for PXR3)
Power supply voltage 100 to 240 V AC, 50/60 Hz or 24 V AC/DC
Front waterproof structure
CD
56+!"#$"%
!14Q"( &$'$()*+ 0*)%%$L$4)($12
(H." (?"#-1%()(
Standard type
Waterproof type
PAS3
(48✕48) (48✕24)
Pt100
J thermocouple
K thermocouple
R thermocouple
B thermocouple
Input signal
S thermocouple
T thermocouple
E thermocouple
N thermocouple
PL II thermocouple
1 to 5V DC
(With resistor) 4 to 20mA DC
Output signal
Relay
For SSR/SSC drive
4 to 20mA DC
ON-OFF
Control method
PID
Auto tuning PID
Fuzzy
Self-tuning
Heating/cooling control
±0.5% FS ±1digit ±1˚C ±3˚C Indicating accuracy
Communicating function (RS-485)
Re-transmission output in 4 to 20 mA DC
Timer function
Digital input
Ramp soak function
Alarm output
Heater burnout alarm (current output unavailable)
100 to 240 V AC, 50/60 Hz or 24 V AC/DC 100 to 240V AC Power supply voltage
Front waterproof structure
C<
!580OIF+I,,89,O:9+988&8&+L1#+)**+3$4#1+012(#1**"#+6+%"#$"%+.#1G/4(%
(Please read carefully the following instructions.)
+ 7!2.).'
+ :R"#Z("-."#)(/#"+5#1("4($12
Any control system design should take into account that any part of the system has the potential to fail.
For temperature control systems, continued heating should be considered the most dangerous condition, and the machine should
be designed to automatically stop heating if unregulated due to the failure of the control unit or for any other reason.
The following are the most likely causes of unwanted continued heating:
In any application where physical injury or destruction of equipment might occur, we recommend the installation of independent
safety equipment, with a separate temperature sensor, to disable the heating circuit in case of overheating.
The controller alarm signal is not designed to function as a protective measure in case of controller failure.
O2("#2)($12)*+!)*"%+&$RV
!)*"%+e#1/.
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fujielectric.com
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425
http://www.fujielectric.com/products/instruments/
Information in this catalog is subject to change without notice. Printed in Japan 2011-4/20FOLS