‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ‬


‫ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪Contents‬‬
‫‪-1‬ﻛﻠﻴﺎت ‪۴ .......................................................................................................................................‬‬

‫‪-2-1‬ﻣﻮﻗﻌﻴﺖ ﺟﻐﺮاﻓﻴﺎﻳﻲ ﻃﺮح ‪۴ ...........................................................................................................‬‬

‫‪ -3-1‬ﺳﻴﻤﺎي ﻃﺮح ‪۶ ..........................................................................................................................‬‬


‫‪ -1 -3 -1‬ﺳﺎﻣﺎﻧﻪ اﻧﺘﻘﺎل آب ‪۶ .................................................................................................................‬‬
‫‪ -2 -3-1‬ﺑﺨﺶ ﭘﻤﭙﺎژ ‪۶ .......................................................................................................................‬‬
‫‪ -3-3-1‬ﺑﺨﺶ ﺗﻮﻧﻞ ‪۶ ........................................................................................................................‬‬
‫‪ -4 -3-1‬ﺑﺨﺶ ﺛﻘﻠﻲ ‪۶ .......................................................................................................................‬‬
‫‪ -4-1‬ﺟﻨﺲ ﻟﻮﻟﻪ ﻫﺎ ‪٧ ..........................................................................................................................‬‬
‫‪ -5-1‬ﻗﻄﺮ ﻟﻮﻟﻪ ﻫﺎ‪٧ ............................................................................................................................‬‬
‫‪ -6-1‬ﺟﺎده ﺳﺮوﻳﺲ ‪٧ .........................................................................................................................‬‬
‫‪ -2‬ﻫﺪف از ﻣﻄﺎﻟﻌﻪ ‪٨ ...........................................................................................................................‬‬
‫‪ -4‬ﻣﻜﺎﻧﻴﺎﺑﻲ ﻧﻴﺮوﮔﺎه ﻛﻮﭼﻚ ‪٩ .................................................................................................................‬‬
‫‪ -5‬اﻃﻼﻋﺎت ﭘﺎﻳﻪ ‪١١ ...........................................................................................................................‬‬
‫‪ -1-5‬ﻣﺸﺨﺼﺎت ﻫﻮاﺷﻨﺎﺳﻲ و ﻫﻴﺪروﻟﻮژي ﻃﺮح ‪١١ .....................................................................................‬‬
‫‪ -2-5‬ﻣﺸﺨﺼﺎت زﻣﻴﻦ ﺷﻨﺎﺳﻲ ﻃﺮح ‪١١ .................................................................................................‬‬

‫‪ -6‬ﻣﻄﺎﻟﻌﺎت ﻫﻴﺪرو اﻧﺮژي ‪١٢ ...............................................................................................................‬‬

‫‪ -1-6‬ﺷﺒﻴﻪ ﺳﺎزي ‪١٣ .........................................................................................................................‬‬


‫‪ -7‬ﻣﻘﺎﻳﺴﻪ ﻧﺘﺎﻳﺞ ‪٢٨ ...........................................................................................................................‬‬
‫‪-8‬ﺗﺠﻬﻴﺰات ﻧﻴﺮوﮔﺎه‪٢٩ ........................................................................................................................‬‬

‫‪ -2-8‬ﻛﻠﻴﺎت ﻃﺮح ‪٢٩ .........................................................................................................................‬‬

‫‪ -2-8‬ﺗﻌﺪاد و ﻇﺮﻓﻴﺖ واﺣﺪﻫﺎ ‪٣١ ..........................................................................................................‬‬

‫‪ -3-8‬اﻧﺘﺨﺎب ﻧﻮع ﺗﻮرﺑﻴﻦ ‪ ،‬ﺳﺮﻋﺖ ﻣﺨﺼﻮص و دور ﻃﺮاﺣﻲ ﺗﻮرﺑﻴﻦ ‪٣١ .........................................................‬‬

‫ﺷﻜﻞ )‪ (5‬ﻣﻨﺤﻨﻲ ﻫﺎي ﻣﺨﺘﻠﻒ ﺑﺮاي ﻣﺤﺎﺳﺒﻪ ‪٣۴ ..................................................................................... ns‬‬

‫‪ -4-8‬ﻣﺸﺨﺼﺎت ﻣﻜﺎﻧﻴﻜﻲ ﻧﻴﺮوﮔﺎﻫﻬﺎي ﻗﻄﻌﺎت ﺳﻮم و ﭼﻬﺎرم ‪٣۵ ................................................................‬‬

‫ﺟﺪول)‪ - (28‬ﻣﺸﺨﺼﺎت ﻣﻜﺎﻧﻴﻜﻲ ﺗﻮرﺑﻴﻦ ‪٣۵ .................................................................................................‬‬

‫‪-9‬ﺗﺠﻬﻴﺰات اﺻﻠﻲ ﻣﻜﺎﻧﻴﻜﻲ ‪٣۶ ............................................................................................................‬‬

‫‪-1-9‬ﺗﺠﻬﻴﺰات ﺗﻮرﺑﻴﻦ‪٣۶ ...................................................................................................................‬‬

‫‪ -1-1-9‬ﻣﺤﻔﻈﻪ ﺗﻮرﺑﻴﻦ )‪٣۶ .................................................................................. :(TURBINE HOUSING‬‬

‫‪ -2-2-9‬راﻧﺮ )‪٣۶ ............................................................................................................... :(RUNNER‬‬

‫‪٢‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -3-2-9‬ﭘﺎﺷﻨﺪه )‪٣٧ ......................................................................................................... :(INJECTOR‬‬

‫‪ -4-2-9‬اﻧﺤﺮاف دﻫﻨﺪه )‪٣٧ .............................................................................................. :(DEFLECTOR‬‬

‫‪ -5-2-9‬ﺟﻤﻊ ﻛﻨﻨﺪه )‪٣٨ .................................................................................................. :(COLLECTOR‬‬

‫‪ -6-2-9‬ﻳﺎﺗﺎﻗﺎن ﺗﻮرﺑﻴﻦ)‪٣٨ .......................................................................... :(TURBINE GUIDE BEARING‬‬

‫‪ -7-2-9‬ﻣﺤﻮر )‪٣٨ ................................................................................................... :(TURBINE SHAFT‬‬

‫‪ -8-2-9‬آب ﺑﻨﺪ ﻣﺤﻮر ﺗﻮرﺑﻴﻦ )‪٣٨ ........................................................................ :(TURBINE SHAFT SEAL‬‬

‫‪ -9-2-9‬ﮔﺎورﻧﺮ)‪٣٩ ......................................................................................................... (GOVERNOR‬‬

‫‪ -10-2-9‬ﺷﻴﺮ ورودي ﺗﻮرﺑﻴﻦ )‪۴٠ ...........................................................................(MAIN INLET VALVE‬‬

‫‪ -10‬ﺗﺠﻬﻴﺰات ﻛﻤﻜﻲ ﻣﻜﺎﻧﻴﻜﻲ ﻧﻴﺮوﮔﺎه ‪۴٠ ...............................................................................................‬‬

‫‪ -1-10‬ﺳﻴﺴﺘﻢ آب ﺧﻨﻚ ﻛﻨﻨﺪه)‪۴١ .................................................................. (COOLING WATER SYSTEM‬‬

‫‪ -2-10‬ﺳﻴﺴﺘﻢ ﺗﺨﻠﻴﻪ و زه ﻛﺸﻲ )‪۴١ ............................................. (DEWATERING AND DRAINAGE SYSTEM‬‬

‫‪ -3-10‬ﺳﻴﺴﺘﻢ ﻫﺎي ﻫﻮاي ﻓﺸﺮده )‪۴٢ ........................................................... (COMPRESSED AIR SYSTEMS‬‬

‫‪ -4-10‬ﺳﻴﺴﺘﻢ ﻫﻮاي ﺳﺮوﻳﺲ‪۴٢ .........................................................................................................‬‬

‫‪ -5-10‬ﺳﻴﺴﺘﻢ ﻫﻮاي ﺗﺮﻣﺰ ‪۴٢ .............................................................................................................‬‬

‫‪ -6-10‬ﺳﻴﺴﺘﻢ روﻏﻦ‪۴٢ ....................................................................................................................‬‬

‫‪ --7-10‬ﺟﺮﺛﻘﻴﻞ ﻧﻴﺮوﮔﺎه ‪۴٢ .................................................................................................................‬‬

‫‪٣‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪-1‬ﻛﻠﻴﺎت‬
‫ﺷﻬﺮ ﻛﺮﻣﺎن‪ ،‬ﻣﺮﻛﺰ اﺳﺘﺎن ﻛﺮﻣﺎن و ﺑﺰرگ ﺗﺮﻳﻦ ﺷﻬﺮ اﻳﻦ اﺳﺘﺎن ﻣﻲ ﺑﺎﺷﺪ و در ﺣﺎل ﺣﺎﺿﺮ ﺟﻤﻌﻴﺖ ﺑﺎﻟﻎ ﺑﺮ‪ 700،000‬ﻧﻔﺮ را در‬

‫ﺧﻮد ﺟﺎي داده اﺳﺖ‪ .‬ﻣﻨﺒﻊ ﺗﺎﻣﻴﻦ آب ﻓﻌﻠﻲ ﺷﻬﺮ ﻛﺮﻣﺎن ﭼﺎه ﻫﺎي ﻣﻮﺟﻮد در اﻃﺮاف ﺷﻬﺮ و ﺗﻌﺪادي ﭼﺎه در ﻣﻨﻄﻘﻪ ﻗﺮﻳﻪ اﻟﻌﺮب ﻣﻲ‬

‫ﺑﺎﺷﺪ‪ .‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺧﺸﻜﺴﺎﻟﻲ ﻫﺎي اﺧﻴﺮ‪ ،‬آب ﺳﻔﺮه ﻫﺎي زﻳﺮزﻣﻴﻨﻲ اﻳﻦ ﻣﻨﻄﻘﻪ ﻛﺎﻫﺶ ﻳﺎﻓﺘﻪ اﺳﺖ و ﺷﻬﺮ را دﭼﺎر ﻛﻤﺒﻮد آب ﻧﻤﻮده‬

‫اﺳﺖ‪ .‬در ﭼﻨﻴﻦ ﺷﺮاﻳﻄﻲ ﻃﺮح ﻫﺎي آﺑﺮﺳﺎﻧﻲ اﻫﻤﻴﺖ دو ﭼﻨﺪان ﭘﻴﺪا ﻣﻲ ﻛﻨﺪ‪ .‬ﺑﺮاي ﺣﻞ ﺑﺨﺸﻲ ﻋﻤﺪه از ﻣﺸﻜﻼت ﺷﻬﺮ ﻛﺮﻣﺎن ﻃﺮح‬

‫اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎ رود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﺪه اﺳﺖ‪.‬‬

‫ﻻزم ﺑﻪ ﺗﻮﺿﻴﺢ اﺳﺖ ﻃﺮح ﺗﺎﻣﻴﻦ آب ﺷﺮب ﺷﻬﺮ ﻛﺮﻣﺎن در ﺟﻠﺴﺎت ﻣﺘﻌﺪد در ﺷﺮﻛﺖ ﻣﻨﺎﺑﻊ آب اﻳﺮان و ﻫﻤﭽﻨﻴﻦ ﺷﺮﻛﺖ ﻣﻬﻨﺪﺳﻲ‬

‫آﺑﻔﺎي ﻛﺸﻮر و در ﺑﺎﻻﺗﺮﻳﻦ ﺳﻄﻮح وزارت ﻧﻴﺮو ﻣﻄﺮح و ﻛﻠﻴﺎت آن ﺑﻪ ﺗﺼﻮﻳﺐ رﺳﻴﺪه اﺳﺖ‪.‬‬

‫ﺣﺠﻢ ﻗﺎﺑﻞ اﻧﺘﻘﺎل از اﻳﻦ ﻃﺮح ﺳﺎﻟﻴﺎﻧﻪ ‪ 59‬ﻣﻴﻠﻴﻮن ﻣﺘﺮ ﻣﻜﻌﺐ ﻣﻲ ﺑﺎﺷﺪ ﻛﻪ ﺑﺎ اﺣﺘﺴﺎب ﺿﺮﻳﺐ ﻣﺎﻛﺰﻳﻤﻢ روزاﻧﻪ ﺣﺪاﻛﺜﺮ دﺑﻲ ﻗﺎﺑﻞ‬

‫اﻧﺘﻘﺎل ‪ 3‬ﻣﺘﺮ ﻣﻜﻌﺐ ﺑﺮ ﺛﺎﻧﻴﻪ ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫‪-2-1‬ﻣﻮﻗﻌﻴﺖ ﺟﻐﺮاﻓﻴﺎﻳﻲ ﻃﺮح‬


‫اﺳﺘﺎن ﻛﺮﻣﺎن در ﺟﻨﻮب ﺷﺮﻗﻲ اﻳﺮان ﻗﺮار ﮔﺮﻓﺘﻪ و ﭘﻬﻨﺎورﺗﺮﻳﻦ اﺳﺘﺎن اﻳﺮان ﻣﻲ ﺑﺎﺷﺪ‪.‬ﺟﻤﻌﻴﺖ اﻳﻦ اﺳﺘﺎن ﺑﺮاﺑﺮ‬

‫‪ 2652413‬ﻧﻔﺮاﺳﺖ‪ .‬ﺑﺮاﺳﺎس آﺧﺮﻳﻦ ﺗﻘﺴﻴﻤﺎت ﻛﺸﻮري‪ ،‬اﺳﺘﺎن ﻛﺮﻣﺎن داراي ‪ 17‬ﺷﻬﺮﺳﺘﺎن‪ 57 ،‬ﺷﻬﺮ و ‪ 45‬ﺑﺨﺶ‬

‫اﺳﺖ‪ .‬ﺷﻬﺮ ﻛﺮﻣﺎن ﺑﺰرﮔﺘﺮﻳﻦ ﺷﻬﺮ و ﻣﺮﻛﺰ اﺳﺘﺎن ﻛﺮﻣﺎن ﻣﻲ ﺑﺎﺷﺪ ﻛﻪ در ﺷﻤﺎل اﺳﺘﺎن واﻗﻊ ﺷﺪه اﺳﺖ‪.‬‬

‫ﻣﻨﻄﻘﻪ ﻣﻮرد ﻣﻄﺎﻟﻌﻪ ﻃﺮح در ﺣﺪود ‪ 110‬ﻛﻴﻠﻮﻣﺘﺮي ﺟﻨﻮب ﺷﺮﻗﻲ ﺷﻬﺮ ﻛﺮﻣﺎن واﻗﻊ ﮔﺮدﻳﺪه اﺳﺖ ‪ .‬اﻧﺘﻘﺎل آب در اﻳﻦ‬

‫ﻃﺮح از ﻛﺪ ارﺗﻔﺎﻋﻲ‪ 2100‬ﻣﺘﺮ از ﺳﻄﺢ درﻳﺎ از آﺑﮕﻴﺮ ﺳﺪ ﺻﻔﺎ واﻗﻊ در ‪ 10‬ﻛﻴﻠﻮﻣﺘﺮي ﺷﻬﺮ راﺑﺮ آﻏﺎز ﺷﺪه و ﺗﺎ ﻣﺨﺎزن‬

‫ﺷﺒﻜﻪ ﺗﻮزﻳﻊ ﺷﻬﺮ ﻛﺮﻣﺎن اداﻣﻪ ﺧﻮاﻫﺪ داﺷﺖ‪.‬‬

‫‪۴‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫ﺷﻜﻞ)‪ -(1‬ﻣﻮﻗﻌﻴﺖ ﺟﻐﺮاﻓﻴﺎﻳﻲ ﻃﺮح‬

‫‪۵‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -3-1‬ﺳﻴﻤﺎي ﻃﺮح‬
‫ﺳﻴﻤﺎي ﻃﺮح اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎ رود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن ﺷﺎﻣﻞ آﺑﮕﻴﺮي‪ ،‬ﭘﻤﭙﺎژ‪ ،‬اﻧﺘﻘﺎل آب‪ ،‬ذﺧﻴﺮه ﺳﺎزي وﺗﺼﻔﻴﻪ آب در ﺣﺪ‬

‫ﺷﺮب و اﻧﺘﻘﺎل ﺑﻪ ﺷﻬﺮﻛﺮﻣﺎن اﺳﺖ‪ :‬ﻛﻪ در اﻳﻦ راﺳﺘﺎ اﺟﺰاي ﻃﺮح ﺑﻪ ﺷﺮح زﻳﺮ اﺣﺪاث ﻣﻲ ﮔﺮدد‪.‬‬

‫ﺗﻮﻧﻞ اﻧﺘﻘﺎل آب ﺑﻪ ﻃﻮل ‪ 38‬ﻛﻴﻠﻮﻣﺘﺮ و ﻗﻄﺮ ﺗﻤﺎم ﺷﺪه ‪ 3/9‬ﻣﺘﺮ‬ ‫‪-‬‬

‫اﻳﺴﺘﮕﺎه ﭘﻤﭙﺎژ ﺑﻪ ﻫﺪ ﭘﻤﭙﺎژ ‪ 320‬ﻣﺘﺮ و دﺑﻲ ‪ 3‬ﻣﺘﺮ ﻣﻜﻌﺐ ﺑﺮ ﺛﺎﻧﻴﻪ‬ ‫‪-‬‬

‫ﻣﺨﺰن ذﺧﻴﺮه آب در ﺧﺮوﺟﻲ ﺗﻮﻧﻞ ﺑﻪ ﻇﺮﻓﻴﺖ ‪ 100‬ﻫﺰارﻣﺘﺮ ﻣﻜﻌﺐ‬ ‫‪-‬‬

‫ﺧﻂ ﻟﻮﻟﻪ ﺑﻪ ﻗﻄﺮ ‪1200‬و ‪ 1400‬ﻣﻴﻠﻴﻤﺘﺮ و ﺑﻄﻮل ‪ 103‬ﻛﻴﻠﻮﻣﺘﺮ‬ ‫‪-‬‬

‫ﺗﺼﻔﻴﻪ ﺧﺎﻧﻪ ﺑﻪ ﻇﺮﻓﻴﺖ ‪ 3‬ﻣﺘﺮ ﻣﻜﻌﺐ ﺑﺮ ﺛﺎﻧﻴﻪ‬

‫‪ -1 -3 -1‬ﺳﺎﻣﺎﻧﻪ اﻧﺘﻘﺎل آب‬


‫ﻣﺴﻴﺮ ﻃﺮح اﻧﺘﻘﺎل ﺑﻪ ﻃﻮل ﺗﻘﺮﻳﺒﻲ ‪ 91‬ﻛﻴﻠﻮﻣﺘﺮﺗﺎ ﻣﺤﻞ ﺗﺼﻔﻴﻪ ﺧﺎﻧﻪ آب ﺷﻬﺮ ﻛﺮﻣﺎن ﻣﻲﺑﺎﺷﺪو اﻧﺘﻘﺎل آب ﻃﻲ ﺳﻪ ﺑﺨﺶ ﭘﻤﭙﺎژ‪،‬‬

‫ﺗﻮﻧﻞ و ﺛﻘﻠﻲ ﻣﻲﺑﺎﺷﺪ‪).‬ﻓﺎﺻﻠﻪ ﺗﺼﻔﻴﻪ ﺧﺎﻧﻪ ﺗﺎ ﺷﻬﺮ ﻛﺮﻣﺎن ‪ 30‬ﻛﻴﻠﻮﻣﺘﺮ ﺑﺮآورد ﮔﺮدﻳﺪه اﺳﺖ(‬

‫‪ -2 -3-1‬ﺑﺨﺶ ﭘﻤﭙﺎژ‬
‫ﺷﺎﻣﻞ ﻳﻚ ﻗﻄﻌﻪ از آﺑﮕﻴﺮ ﺳﺪ در ﻛﺪ ارﺗﻔﺎﻋﻲ ‪ 2100‬ﻣﺘﺮ از ﺳﻄﺢ درﻳﺎ ﺑﻪ ﻛﺪ ارﺗﻔﺎﻋﻲ ‪ 2375‬ﻣﺘﺮ از ﺳﻄﺢ درﻳﺎ در‬

‫‪ 13‬ﻛﻴﻠﻮﻣﺘﺮي ﺳﺪ ﺻﻔﺎ رود ﻣﻲ ﺑﺎﺷﺪ و ﻗﻄﺮ آن ‪ 1400‬ﻣﻴﻠﻴﻤﺘﺮ از ﺟﻨﺲ ﻓﻮﻻد ﺗﻌﻴﻴﻦ ﮔﺮدﻳﺪه اﺳﺖ‪.‬‬

‫‪ -3-3-1‬ﺑﺨﺶ ﺗﻮﻧﻞ‬
‫ﺗﻮﻧﻞ ﺑﻪ ﻗﻄﺮ ﺗﻤﺎم ﺷﺪه ‪ 3.9‬ﻣﺘﺮ و ﻃﻮل ‪ 38‬ﻛﻴﻠﻮﻣﺘﺮ و ﺷﻴﺐ ﺣﺪود ‪ 0/0014‬ﻛﻪ آب را از ﻣﻨﻄﻘﻪ ﮔﻨﺠﺎن ﺑﻪ ﻣﻨﻄﻘﻪ ﮔﻠﺰار اﻧﺘﻘﺎل‬

‫ﻣﻲ دﻫﺪ‪.‬‬

‫‪ -4 -3-1‬ﺑﺨﺶ ﺛﻘﻠﻲ‬
‫ﺷﺎﻣﻞ ﺳﻪ ﻗﻄﻌﻪ ﻛﻪ از ﻛﺪ ارﺗﻔﺎﻋﻲ ‪ 2370‬ﻣﺘﺮ از ﺳﻄﺢ درﻳﺎ در ‪ 6‬ﻛﻴﻠﻮﻣﺘﺮي ﺷﻬﺮﮔﻠﺰار ﺷﺮوع ﺷﺪه و ﺑﻪ ﻣﺨﺰن ﺗﺼﻔﻴﻪ ﺧﺎﻧﻪ در ﻛﺪ‬

‫ارﺗﻔﺎﻋﻲ ‪ 1915‬ﻣﺘﺮ از ﺳﻄﺢ درﻳﺎ ﻣﻨﺘﻬﻲ ﻣﻲ ﮔﺮدد ‪ .‬ﻃﻮل اﻳﻦ ﺑﺨﺶ ‪40‬ﻛﻴﻠﻮﻣﺘﺮ و ﻗﻄﺮ آن ‪1200‬ﻣﻴﻠﻴﻤﺘﺮاز ﺟﻨﺲ ﻓﻮﻻد ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫ﺳﺎﻳﺮ ﻣﺸﺨﺼﺎت ﻃﺮح در ﺟﺪاول اراﺋﻪ ﺷﺪه اﺳﺖ‪.‬‬

‫‪۶‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -4-1‬ﺟﻨﺲ ﻟﻮﻟﻪ ﻫﺎ‬


‫ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻗﻄﺮ ﺧﻂ اﻧﺘﻘﺎل ) ‪ 1200‬و ‪ 1400‬ﻣﻴﻠﻴﻤﺘﺮ( و اﺳﺘﻌﻼم ﻫﺎي اﺧﺬ ﺷﺪه از ﺷﺮﻛﺘﻬﺎي ﻟﻮﻟﻪ ﺳﺎزي‪ ،‬ﺷﺮﻛﺖ‬

‫ﻫﺎﻳﻲ ﻛﻪ ﻟﻮﻟﻪ ﺑﺎ ﻗﻄﺮﻫﺎي ﺑﺎﻻ ﺗﻮﻟﻴﺪ ﻣﻲ ﻛﻨﻨﺪ ﻛﺎرﺧﺎﻧﻪ ﻫﺎي ﺳﺎﺧﺖ ﻟﻮﻟﻪ ﻫﺎي ‪ G.R.P‬و ﻓﻮﻻدي ﻣﻲﺑﺎﺷﺪ‪ ،‬ﻫﻤﭽﻨﻴﻦ ﺑﺎ‬

‫ﺗﻮﺟﻪ ﺑﻪ ﭘﺮوﻓﻴﻞ ﻃﻮﻟﻲ ﻣﺴﻴﺮ ﺧﻂ اﻧﺘﻘﺎل‪ ،‬ﻓﺸﺎر ﻛﺎريﺧﻂ اﻧﺘﻘﺎل از ‪ 10‬ﺑﺎر ﺗﺎ ‪ 35‬ﺑﺎر ﻣﻲﺑﺎﺷﺪ و ﺑﺎ در ﻧﻈﺮ داﺷﺘﻦ‬

‫ﻛﻮﻫﺴﺘﺎﻧﻲ ﺑﻮدن ﻣﺴﻴﺮ ﺧﻂ اﻧﺘﻘﺎل‪ ،‬ﺑﻪ دﻟﻴﻞ اﺳﺘﺤﻜﺎم ﻟﻮﻟﻪ ﻫﺎي ﻓﻮﻻدي و ﻋﺪم اﺳﺘﺤﻜﺎم ﻟﻮﻟﻪ ﻫﺎي ‪ G.R.P‬اﻳﻦ‬

‫ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎور اﺳﺘﻔﺎده از ﻟﻮﻟﻪ ﻫﺎي ﻓﻮﻻدي را ﺗﻮﺻﻴﻪ ﻣﻲﻧﻤﺎﻳﺪ‪.‬‬

‫‪ -5-1‬ﻗﻄﺮ ﻟﻮﻟﻪ ﻫﺎ‬


‫ﻗﻄﺮ ﻟﻮﻟﻪ ﻫﺎ در ﻗﺴﻤﺖ ﭘﻤﭙﺎژ ‪ 1400‬ﻣﻴﻠﻴﻤﺘﺮ و در ﻗﺴﻤﺖ ﺛﻘﻠﻲ ‪ 1200‬ﻣﻴﻠﻴﻤﺘﺮ اﺳﺖ‪.‬‬

‫‪ -6-1‬ﺟﺎده ﺳﺮوﻳﺲ‬
‫ﺟﻬﺖ ﺳﻬﻮﻟﺖ ﻋﻤﻠﻴﺎت اﺟﺮاﻳﻲ و ﻧﻴﺰ ﺑﻬﺮه ﺑﺮداري ﻣﻨﺎﺳﺐ در ﻃﻮل ﺧﻂ اﻧﺘﻘﺎل ﺟﺎده ﺳﺮوﻳﺴﻲ در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﺪه اﺳﺖ‬

‫ﻋﺮض ﺟﺎده ﺳﺮوﻳﺲ ‪ 17‬ﻣﺘﺮ ﻣﻲ ﺑﺎﺷﺪ ‪.‬‬

‫ﺷﻜﻞ )‪ -(2‬ﺗﻴﭗ ﺟﺎده ﺳﺮوﻳﺲ‬

‫‪٧‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -2‬ﻫﺪف از ﻣﻄﺎﻟﻌﻪ‬
‫در اﻳﻦ ﻣﻄﺎﻟﻌﻪ ﻫﺪف اﻣﻜﺎن ﺳﻨﺠﻲ اﻓﺰودن ﻧﻴﺮوﮔﺎه ﻛﻮﭼﻚ ﺑﺮاي اﺳﺘﻔﺎده از ﺣﺪاﻛﺜﺮ دﺑﻲ ﺛﻘﻠﻲ ﺧﻂ اﻧﺘﻘﺎل از ﺳﺪ ﺻﻔﺎ رود ﺑﻪ‬
‫ﻣﺨﺎزن ذﺧﻴﺮه ﻣﻲ ﺑﺎﺷﺪ‪ .‬در ﺷﺮاﻳﻂ ﻧﺮﻣﺎل ﺑﺨﺸﻬﺎﻳﻲ ﺑﻪ ﺷﺮح زﻳﺮ ﻣﻄﺮح اﺳﺖ ﻛﻪ ﺑﻌﻨﻮان ﺗﺎﺳﻴﺴﺎت اﻧﺘﻘﺎل آب ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن از ﺳﺪ‬
‫ﺻﻔﺎ رود ﺑﻌﻨﻮان ﺗﺎﻣﻴﻦ ﻛﻨﻨﺪه آب ﻣﻴﺎن ﻣﺪت ﻛﺮﻣﺎن ﺑﻄﻮر ﻣﺘﻮﺳﻂ ﻣﺎﻫﺎﻧﻪ ﻣﻄﺮح اﺳﺖ‪.‬‬

‫‪ -1‬اﺣﺪاث ﺧﻂ اﻧﺘﻘﺎل آب ﺑﻪ اﻗﻄﺎر ‪ 1400‬و ‪ 1200‬ﻣﻴﻠﻴﻤﺘﺮ ﺑﻄﻮل ‪ 103‬ﻛﻴﻠﻮﻣﺘﺮ‬


‫‪ -2‬اﺣﺪاث ﻳﻚ واﺣﺪ ﺗﺼﻔﻴﻪ ﺧﺎﻧﻪ ﺑﻪ ﻇﺮﻓﻴﺖ ﺣﺪاﻛﺜﺮ ‪ 3‬ﻣﺘﺮ ﻣﻜﻌﺐ ﺑﺮ ﺛﺎﻧﻴﻪ‬
‫‪ -3‬ﺗﻮﻧﻞ اﻧﺘﻘﺎل آب ﺑﻄﻮل ‪ 38‬ﻛﻴﻠﻮﻣﺘﺮ و ﻗﻄﺮ ﺗﻤﺎم ﺷﺪه ‪ 3/9‬ﻣﺘﺮ‬
‫‪ -4‬ﺑﺨﺶ ﻫﺎي دﻳﮕﺮ از ﻃﺮح ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ اﻧﺘﺨﺎب ﭘﻴﻤﺎﻧﻜﺎر در ﻣﺮﺣﻠﻪ ﺷﺮوع ﻋﻤﻠﻴﺎت اﺟﺮاﻳﻲ ﻣﻴﺒﺎﺷﺪ‪.‬‬
‫‪ -5‬اﻳﺴﺘﮕﺎه ﭘﻤﭙﺎژ ﺑﻪ ﻫﺪ ‪ 320‬ﻣﺘﺮ و دﺑﻲ ‪ 3‬ﻣﺘﺮﻣﻜﻌﺐ‬
‫‪ -6‬ﻣﺨﺰن ذﺧﻴﺮه آب در ﺧﺮوﺟﻲ ﺗﻮﻧﻞ ﺑﻪ ﻇﺮﻓﻴﺖ ‪ 100‬ﻣﺘﺮ ﻣﻜﻌﺐ و ﻣﺨﺰن ﺗﻌﺪﻳﻞ ﻓﺸﺎر‬

‫ﻧﻈﺮ ﺑﻪ اﻳﻨﻜﻪ ﺣﺠﻢ ﻗﺎﺑﻞ اﻧﺘﻘﺎل از اﻳﻦ ﻃﺮح ﺳﺎﻟﻴﺎﻧﻪ ‪ 59‬ﻣﻴﻠﻴﻮن ﻣﺘﺮ ﻣﻜﻌﺐ ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﺑﻄﻮر ﻣﺘﻮﺳﻂ ﻇﺮﻓﻴﺖ ‪ 2‬ﻣﺘﺮ ﻣﻜﻌﺐ‬
‫ﺑﺮ ﺛﺎﻧﻴﻪ ﺑﻌﻨﻮان دﺑﻲ ﻗﺎﺑﻞ اﻧﺘﻘﺎل از ﺧﻂ ﻟﻮﻟﻪ ﺑﻪ ﻗﻄﺮ ‪ 1219/2‬ﻣﻴﻠﻴﻤﺘﺮ)ﺧﺎرﺟﻲ( اﺳﺖ و ﺿﺨﺎﻣﺖ ﻟﻮﻟﻪ ‪ 11‬ﻣﻴﻠﻴﻤﺘﺮ ﻣﻲ‬
‫ﺑﺎﺷﺪ‪ .‬ﺟﻨﺲ ﻟﻮﻟﻪ ﻫﺎ ﻓﻮﻻدي و ﻻﻳﻨﻴﻨﮓ آن ﻣﻼت ﻣﺎﺳﻪ ﺳﻴﻤﺎن ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫‪ -3‬روﻳﻜﺮد ﻣﻄﺎﻟﻌﻪ‬

‫در اﻳﻦ ﻣﻄﺎﻟﻌﻪ روﻳﻜﺮد اﺻﻠﻲ ﺑﺮ ﻣﺒﻨﺎي اﺳﺘﻔﺎده از ﺣﺠﻢ ﻗﺎﺑﻞ اﻧﺘﻘﺎل از ﺳﺪ ﺻﻔﺎ رود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﺑﻨﺎﺑﺮاﻳﻦ‬
‫ﻓﺮض ﺑﻬﺮه ﺑﺮداري ﺑﺮ اﺳﺎس ﻇﺮﻓﻴﺘﻲ اﺳﺖ ﻛﻪ ﻣﺘﻨﺎﺳﺐ ﺑﺎ ﻧﻴﺎز ﺷﻬﺮ ﻛﺮﻣﺎن ﺑﻪ آب ﺷﺮب ﺑﻄﻮر ﺳﺎﻟﻴﺎﻧﻪ ﻣﻄﺎﺑﻖ ﺑﺎ ﺟﺪول)‪(1‬‬
‫ﺗﻌﺮﻳﻒ ﺷﺪه اﺳﺖ‪.‬‬

‫ﺟﺪول)‪-(1‬ﻣﻘﺎدﻳﺮ ﻇﺮﻓﻴﺖ دﺑﻲ اﻧﺘﻘﺎل از ﻃﺮﻳﻖ ﺧﻂ در ﻃﻮل ﺳﺎل‬

‫درﺻﺪ ﺳﺎﻻﻧﻪ‬ ‫ﻫﺪ در ﻣﺤﻞ ﺗﺤﻮﻳﻞ آب )ﻣﺘﺮ(‬


‫ردﻳﻒ دﺑﻲ)‪(cms‬‬
‫دﺑﻲ)‪(%‬‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫‪٣/۶‬‬ ‫‪٢٢١/٨٨‬‬ ‫‪٢١۶/۴١‬‬ ‫‪٠/۵‬‬ ‫‪١‬‬
‫‪٣/۶‬‬ ‫‪٢٠۵/۶۴‬‬ ‫‪٢١٢/۵٢‬‬ ‫‪١‬‬ ‫‪٢‬‬
‫‪٣/۶‬‬ ‫‪٢٠۵‬‬ ‫‪١٩۶/٩٢‬‬ ‫‪١/۵‬‬ ‫‪٣‬‬
‫‪٨٢‬‬ ‫‪١۴٨/١٨‬‬ ‫‪١٨۵/٠٨‬‬ ‫‪٢‬‬ ‫‪۴‬‬
‫‪٣/۶‬‬ ‫‪١٣٠.Type equation here/٢٢‬‬ ‫‪١۴٧‬‬ ‫‪٢/۵‬‬ ‫‪۵‬‬
‫‪٣/۶‬‬ ‫‪٩٠/٧٢‬‬ ‫‪١١٢.۶٧‬‬ ‫‪٣‬‬ ‫‪۶‬‬

‫‪٨‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -4‬ﻣﻜﺎﻧﻴﺎﺑﻲ ﻧﻴﺮوﮔﺎه ﻛﻮﭼﻚ‬


‫ﺟﺎﻧﻤﺎﻳﻲ ﻋﻤﻮﻣﻲ واﺣﺪﻫﺎي ﻧﻴﺮوﮔﺎﻫﻲ ﻣﻲ ﺗﻮاﻧﺪ در ﻃﻮل ﺧﻂ وﺑﺎﻻدﺳﺖ ﻣﺨﺎزن ذﺧﻴﺮه ﻗﺮار ﮔﻴﺮد‪ .‬در اﻳﻨﺼﻮرت ﻫﺮ ﻧﻴﺮوﮔﺎه ﺑﻄﻮر‬
‫ﻣﻮازي در ﻣﺠﺎور اﻳﺴﺘﮕﺎه ﻓﺸﺎر ﺷﻜﻦ واﻗﻊ ﻣﻴﮕﺮدد‪.‬‬

‫ﺑﺎ ﺟﺎﻧﻤﺎﻳﻲ دو واﺣﺪ ﻧﻴﺮوﮔﺎﻫﻲ در اﻧﺘﻬﺎي ﻗﻄﻌﻪ ﺳﻮم و ﭼﻬﺎرم ﻫﺮ ﻳﻚ ﺷﺎﻣﻞ دو ﺗﻮرﺑﻴﻦ در اﻧﺘﻬﺎي ﺧﻂ و ﻣﺠﺎور ﻣﺨﺎزن ذﺧﻴﺮه‪،‬‬
‫ﺣﺪاﻛﺜﺮ اﻧﺮژي ﺗﻮﻟﻴﺪي ﺑﺮﻗﺎﺑﻲ اﺳﺘﺤﺼﺎل ﻣﻲ ﮔﺮدد‪ .‬اﻳﻦ در ﺣﺎﻟﻴﺴﺘﻜﻪ در ﻣﻮاﻗﻌﻴﻜﻪ ﻧﻴﺮوﮔﺎه ﻣﺘﻮﻗﻒ ﺷﻮد‪ ،‬ﻧﻴﺎز ﺧﻂ ﺗﻮﺳﻂ اﻳﺴﺘﮕﺎه‬
‫ﻓﺸﺎر ﺷﻜﻦ رﻫﺎ ﻣﻲ ﮔﺮدد‪ .‬ﺑﻌﺒﺎرت دﻳﮕﺮ ﻫﻴﭽﮕﺎه ﺧﻂ اﻧﺘﻘﺎل ﺑﻲ ﻧﻴﺎز از اﻳﺴﺘﮕﺎه ﻓﺸﺎر ﺷﻜﻦ ﻧﺨﻮاﻫﺪ ﺑﻮد و ﻓﻘﻂ ﺟﻬﺖ ﺑﻬﺮه ﺑﺮداري‬
‫از ﺣﺪاﻛﺜﺮ ﻇﺮﻓﻴﺖ ﺗﻮﻟﻴﺪ اﻧﺮژي از ﻃﺮﻳﻖ ﻳﻚ ﺳﻴﺴﺘﻢ ﻛﻨﺎر ﮔﺬر) ‪ (Bypass‬ﺑﺮاي ﺑﻬﺮه ﺑﺮداري از ﻧﻴﺮوﮔﺎه اﺳﺘﻔﺎده ﻣﻲ ﺷﻮد‪ .‬ﻧﻜﺘﻪ‬
‫ﻣﻬﻢ دﻳﮕﺮ اﻳﻨﻜﻪ ﻛﺎرﻛﺮد ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ در ﺷﺮاﻳﻂ ﻏﺮﻗﺎﺑﻲ ﻣﺜﺒﺖ دﻳﺪه ﻣﻲ ﺷﻮد ﺑﺪﻳﻦ ﻣﻌﻨﻲ ﻛﻪ ﺗﺮاز ﻣﺤﻮر ﺗﻮرﺑﻴﻦ ﻣﻲ ﺑﺎﻳﺴﺖ ﻫﻤﻮاره‬
‫ﺑﺎﻻ ﺗﺮ از ﺗﺮاز ﭘﺎﻳﺎب ﻗﺮار ﮔﻴﺮد‪ .‬ﺑﻨﺎﺑﺮاﻳﻦ ﺑﺮاي ﺗﺎﻣﻴﻦ اﻳﻦ ﺷﺮاﻳﻂ ﻻزم اﺳﺖ ﺗﻮرﺑﻴﻦ در ﺑﺎﻻدﺳﺖ ﻣﺨﺰن ذﺧﻴﺮه ﺟﺎﻧﻤﺎﻳﻲ ﺷﻮد‪ .‬در‬
‫اﻳﻨﺼﻮرت ﺣﺪاﻛﺜﺮ ﺗﺮاز ﻫﻴﺪروﻟﻴﻜﻲ ﭘﺎﻳﺎب ﻣﻌﺎدل ﺑﺎ ﺗﺮاز ﻧﺮﻣﺎل ﻣﺨﺰن ﺧﻮاﻫﺪ ﺑﻮد‪ .‬ﺟﺎﻧﻤﺎﻳﻲ ﻋﻤﻮﻣﻲ واﺣﺪ ﻧﻴﺮوﮔﺎﻫﻲ ﻣﻄﺎﺑﻖ ﺑﺎ‬
‫ﺷﻜﻞ)‪ (3‬در ﻛﻨﺎر اﻳﺴﺘﮕﺎه ﻓﺸﺎر ﺷﻜﻦ ﭘﻴﺸﻨﻬﺎد ﻣﻲ ﮔﺮدد‪.‬‬

‫‪٩‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫ﺷﻜﻞ)‪ -(3‬ﺟﺎﻧﻤﺎﻳﻲ ﻋﻤﻮﻣﻲ واﺣﺪ ﻧﻴﺮوﮔﺎﻫﻲ در ﻣﺠﺎور ﻣﺨﺎزن ذﺧﻴﺮه‬

‫خط انقال اب‬


‫ايستگاه فشار‬
‫شکن‬

‫نيروگاه برقابی‬

‫مخزن ذخيره‬
‫‪١٠٠٠٠٠‬متر مکعبی‬

‫‪١٠‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -5‬اﻃﻼﻋﺎت ﭘﺎﻳﻪ‬

‫‪ -1-5‬ﻣﺸﺨﺼﺎت ﻫﻮاﺷﻨﺎﺳﻲ و ﻫﻴﺪروﻟﻮژي ﻃﺮح‬


‫ﻣﺴﺎﺣﺖ ﺣﻮزه ﻫﺎي ﺳﺪ ﺻﻔﺎ ﺑﺮاﺑﺮ ‪ 420‬ﻛﻴﻠﻮﻣﺘﺮﻣﺮﺑﻊ‪ ،‬ارﺗﻔﺎع ﻣﺘﻮﺳﻂ ﺣﻮزه ‪ 2789‬ﻣﺘﺮ از ﺳﻄﺢ درﻳﺎ و زﻣﺎن ﺗﻤﺮﻛﺰ ﺑﺮاﺑﺮ ‪4‬ﺳﺎﻋﺖ‬

‫ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﺣﺪاﻛﺜﺮ ﺑﺎرش ﭘﺲ از ﺑﺎزﺳﺎزي ﺧﻼءﻫﺎي آﻣﺎري در اﻳﺴﺘﮕﺎه ﻛﻴﮕﺎن ‪ 728/9‬ﻣﻴﻠﻴﻤﺘﺮ و ﺣﺪاﻗﻞ ﺑﺎرش در اﻳﺴﺘﮕﺎه اردﻳﻜﺎن‬

‫‪ 14/7‬ﻣﻴﻠﻴﻤﺘﺮ اﻧﺪازه ﮔﻴﺮي ﺷﺪه اﺳﺖ‪ .‬ﺣﺪاﻛﺜﺮ ﻣﻴﺎﻧﮕﻴﻦ دﻣﺎ در ﺗﻴﺮﻣﺎه و ﺣﺪاﻗﻞ دﻣﺎ در ﺑﻬﻤﻦ ﻣﺎه ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﻃﺒﻖ ﺑﺮرﺳﻲ اﻧﺠﺎم ﺷﺪه‬

‫ﭘﺎراﻣﺘﺮﻫﺎي دﻣﺎ در اﻳﺴﺘﮕﺎه ﺳﻐﺪر )ﮔﺮﻣﺘﺮﻳﻦ اﻳﺴﺘﮕﺎه( و ﺳﺎردوﻳﻴﻪ )ﺳﺮدﺗﺮﻳﻦ اﻳﺴﺘﮕﺎه( ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﺑﻴﺸﺘﺮﻳﻦ ﻣﻘﺪار ﺗﺒﺨﻴﺮ در ﻣﺎه ﺗﻴﺮ و‬

‫ﻛﻤﺘﺮﻳﻦ ﻣﻘﺪار در ﻣﺎه ﺑﻬﻤﻦ ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﺣﺪاﻛﺜﺮ و ﺣﺪاﻗﻞ اﻳﻦ ﻣﻘﺎدﻳﺮ در اﻳﺴﺘﮕﺎه ﻻﻟﻪ زار ‪ 244/4‬و ‪ 43/4‬ﻣﻴﻠﻴﻤﺘﺮ و در اﻳﺴﺘﮕﺎه‬

‫ﭼﻬﺎرﻃﺎق ‪ 292/4‬و ‪ 38‬ﻣﻴﻠﻴﻤﺘﺮ ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﺣﺪاﻛﺜﺮ ﻣﻴﺎﻧﮕﻴﻦ ﻧﻢ ﻧﺴﺒﻲ در اﻳﺴﺘﮕﺎه ﻻﻟﻪ زار ‪ 72‬درﺻﺪ و ﺣﺪاﻗﻞ آن ‪ 19‬درﺻﺪ ﻣﻲ‬

‫ﺑﺎﺷﺪ‪ ،‬ﺿﻤﻦ آﻧﻜﻪ ﺣﺪاﻛﺜﺮ و ﺣﺪاﻗﻞ ﻧﻢ ﻧﺴﺒﻲ در اﻳﺴﺘﮕﺎه ﭼﻬﺎرﻃﺎق ‪ 76/5‬و‪ 20‬درﺻﺪ اﺳﺖ‪ .‬در اﻳﺴﺘﮕﺎﻫﻬﺎي ﺳﻴﻨﻮﭘﺘﻴﻚ و‬

‫ﻛﻠﻴﻤﺎﺗﻮﻟﻮژي ﺗﺎﺑﻊ ﺳﺎزﻣﺎن ﻫﻮاﺷﻨﺎﺳﻲ ﻛﺸﻮر ﺣﺪاﻛﺜﺮ اﻳﺎم ﻳﺨﺒﻨﺪان ‪ 199/4‬روز ﺳﺎﻻﻧﻪ در اﻳﺴﺘﮕﺎه ﺳﺎروﺋﻴﺪ و ﺣﺪاﻗﻞ اﻳﺎم ﻳﺨﺒﻨﺪان‬

‫‪ 1/5‬روز ﺳﺎﻻﻧﻪ در اﻳﺴﺘﮕﺎه ﻣﻴﺎﻧﺪه ﺛﺒﺖ ﺷﺪه اﺳﺖ‪ .‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺑﺮرﺳﻲ اﻧﺠﺎم ﺷﺪه ﻣﻴﺎﻧﮕﻴﻦ ﺳﺎﻋﺎت آﻓﺘﺎﺑﻲ در ﻣﺎﻫﻬﺎي ﺗﻴﺮ و ﺧﺮداد‬

‫ﺣﺪاﻛﺜﺮ و در ﻣﺎﻫﻬﺎي آذر و دي ﺣﺪاﻗﻞ ﻣﻲﺑﺎﺷﺪ‪ .‬ﻧﺘﺎﻳﺞ ﻣﺤﺎﺳﺒﺎت آﺑﺪﻫﻲ اﻗﺘﺒﺎس ﺷﺪه از ﻣﻄﺎﻟﻌﺎت ﻫﻴﺪروﻟﻮژي‪ ،‬ﺑﻪ اﻳﻦ ﺗﺮﺗﻴﺐ اﺳﺖ‬

‫ﻛﻪ ﻣﻘﺎدﻳﺮ ﻣﻴﺎﻧﮕﻴﻦ و اﻧﺤﺮاف ﻣﻌﻴﺎر دﺑﻲ ﻣﺘﻮﺳﻂ ﺳﺎﻻﻧﻪ در ﺳﺎﺧﺘﮕﺎه ﺳﺪ ﺻﻔﺎ ﺑﻪ ﺗﺮﺗﻴﺐ ﺑﺮاﺑﺮ ﺑﺎ ‪ 2/32‬و ‪ 2/23‬ﻣﺘﺮﻣﻜﻌﺐ ﺑﺮ ﺛﺎﻧﻴﻪ و‬

‫ﻣﻘﺎدﻳﺮ ﻣﻴﺎﻧﮕﻴﻦ و اﻧﺤﺮاف ﻣﻌﻴﺎر ﺣﺠﻢ رواﻧﺎب ﺳﺎﻻﻧﻪ ﺑﺮاﺑﺮ ﺑﺎ ‪ 71/81‬و ‪ 68/94‬ﻣﻴﻠﻴﻮن ﻣﺘﺮﻣﻜﻌﺐ ﻣﻲ ﺑﺎﺷﺪ‪ .‬در ﻣﺤﺎﺳﺒﺎت اﻧﺠﺎم‬

‫ﮔﺮﻓﺘﻪ ﺗﺨﻤﻴﻦ ﺳﻴﻼب‪ ،‬ﻣﻘﺎدﻳﺮ ﻧﻬﺎﻳﻲ ﭘﻴﻚ ﻟﺤﻈﻪ اي ﺳﻴﻼب ﺑﺎ دوره ﺑﺎزﮔﺸﺖ ده ﻫﺰار ﺳﺎل در ﻣﺤﻞ ﺳﺪ ﺻﻔﺎ ﺑﺮاﺑﺮ ﺑﺎ ‪1490‬‬

‫ﻣﺘﺮﻣﻜﻌﺐ در ﺛﺎﻧﻴﻪ ﺑﺪﺳﺖ آﻣﺪه اﺳﺖ‪ .‬ﺣﺪاﻛﺜﺮ ﺑﺎرﻧﺪﮔﻲ ﻣﺤﺘﻤﻞ )‪ (PMP‬ﺑﺎ اﺳﺘﻔﺎده از روش ﻫﺮﺷﻔﻴﻠﺪ ﺑﺮاﺑﺮ ﺑﺎ ‪ 280‬ﻣﻴﻠﻴﻤﺘﺮ ﺑﺮآورد‬

‫ﺷﺪه اﺳﺖ‪.‬‬

‫‪ -2-5‬ﻣﺸﺨﺼﺎت زﻣﻴﻦ ﺷﻨﺎﺳﻲ ﻃﺮح‬


‫ﮔﺴﺘﺮه ﻣﻮرد ﻣﻄﺎﻟﻌﻪ از ﺗﻮان ﻟﺮزهزاﻳﻲ ﻧﺴﺒﺘﺎً ﺑﺎﻻﻳﻲ ﺑﺮﺧﻮردار اﺳﺖ و اﺣﺘﻤﺎل روﻳﺪاد زﻣﻴﻦ ﻟﺮزه ﻫﺎي ﺑﺎ ﺑﺰرﮔﻲ ﺑﻴﺶ از ‪ 7/5‬رﻳﺸﺘﺮ‬

‫وﺟﻮد دارد‪ .‬ﺣﺪاﻛﺜﺮ ﺗﻮان ﻟﺮزه زاﻳﻲ ﮔﺴﻞ ﻫﺎي اﺻﻠﻲ ﻣﻨﻄﻘﻪ ﺑﻪ ﺑﺰرﮔﻲ ‪ 7/5‬ﺗﺎ ‪ 7/52‬رﻳﺸﺘﺮ ﺧﻮاﻫﺪ ﺑﻮد‪ .‬ﺿﻤﻦ آﻧﻜﻪ ﮔﺴﻞ ﺳﺒﺰواران‬

‫ﺑﺎ ﻃﻮل ﻧﺴﺒﺘﺎً زﻳﺎد )ﺣﺪود ‪ 207‬ﻛﻴﻠﻮﻣﺘﺮ( ﻣﻲﺗﻮاﻧﺪ زﻟﺰﻟﻪ اي ﺑﻪ ﺑﺰرﮔﻲ ‪ 7/44‬رﻳﺸﺘﺮ در ﻣﻨﻄﻘﻪ اﻳﺠﺎد ﻛﻨﺪ‪.‬‬

‫در ﻣﺮزﻫﺎي ﮔﺴﻠﻲ ﻣﺼﺎﻟﺢ زﻣﻴﻦ ﺷﻨﺎﺳﻲ ﺑﻪ ﺷﺪت ﺧﺮد ﺷﺪه و ﺳﺴﺖ ﻣﻲ ﺑﺎﺷﻨﺪ‪ .‬ﺑﻪ دﻟﻴﻞ ﻣﻨﻔﺼﻞ ﺑﻮدن ﻣﺼﺎﻟﺢ در زون ﻫﺎي‬

‫ﮔﺴﻠﻲ و ﺑﻪ ﺗﺒﻊ آن اﻓﺰاﻳﺶ ﻧﻔﻮذﭘﺬﻳﺮي‪ ،‬ﻣﻤﻜﻦ اﺳﺖ ﺣﻔﺮ ﺗﺮاﻧﺸﻪ و ﻛﺎﻧﺎل در ﭼﻨﻴﻦ ﻣﻜﺎﻧﻬﺎﻳﻲ‪ ،‬درﺻﻮرت ﺑﺎﻻﺑﻮدن ﺳﻄﺢ آب‬

‫زﻳﺮزﻣﻴﻨﻲ‪ ،‬ﺑﺎ ﺧﻄﺮ ﻫﺠﻮم آب ﻫﻤﺮاه ﺑﺎﺷﺪ‪.‬‬

‫‪١١‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫در ﻃﻮل ﺧﻂ ﻟﻮﻟﻪ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎ ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن ﺧﻄﺮات زﻣﻴﻦ ﺷﻨﺎﺳﻲ وﺟﻮد دارد ﻛﻪ اﻫﻢ آﻧﻬﺎ ﺑﻪ ﻗﺮار زﻳﺮ ﻣﻲ ﺑﺎﺷﺪ ‪:‬‬

‫‪ (1‬ﺧﻄﺮ ﻧﺎﺷﻲ از ﺗﻘﺎﻃﻊ ﺧﻂ ﻟﻮﻟﻪ ﺑﺎ ﮔﺴﻞ‬

‫‪ (2‬ﺧﻄﺮ ﻧﺎﺷﻲ از ﻓﺮﺳﺎﻳﺶ ﻣﺼﺎﻟﺢ‬

‫‪ (3‬ﺧﻄﺮ ﻧﺎﺷﻲ از اﻧﺤﻼل ﻣﺼﺎﻟﺢ‬

‫‪ (4‬ﺧﻄﺮ ﻧﺎﺷﻲ از ﺧﻮرﻧﺪﮔﻲ ﺑﺮﺧﻲ اﻣﻼح ﺑﺮروي ﻣﺼﺎﻟﺢ ﺳﺎﺧﺘﻤﺎﻧﻲ و ﺧﻂ ﻟﻮﻟﻪ‬

‫‪ (5‬ﺧﻄﺮ ﺷﻨﺎور ﺷﺪن ﻟﻮﻟﻪ‬

‫‪ -6‬ﻣﻄﺎﻟﻌﺎت ﻫﻴﺪرو اﻧﺮژي‬


‫ﻣﻄﺎﻟﻌﺎت ﻫﻴﺪرو اﻧﺮژي ﺑﺎ اﺳﺘﻔﺎده از راﺑﻄﻪ ﺗﻮﻟﻴﺪ اﻧﺮژي اﻧﺠﺎم ﺷﺪه اﺳﺖ‪ .‬ﺑﺪﻳﻦ ﻣﻨﻈﻮر ﺑﺮاي ﻇﺮﻓﻴﺖ ﻫﺎي ﻧﺼﺐ ﻣﺨﺘﻠﻒ‪،‬‬
‫ﺳﻨﺎرﻳﻮﻫﺎي ﺗﻮﻟﻴﺪ ﺗﻌﺮﻳﻒ ﺷﺪه و ﻧﺘﺎﻳﺞ ﺑﺎ ﻳﻜﺪﻳﮕﺮ ﻣﻘﺎﻳﺴﻪ ﺷﺪه اﺳﺖ‪ .‬در اﻳﻦ ﻣﺮﺣﻠﻪ از ﻣﻄﺎﻟﻌﺎت ﺗﺪوﻳﻦ ﺳﻨﺎرﻳﻮﻫﺎ ﺑﺎ در ﻧﻈﺮ ﮔﺮﻓﺘﻦ‬
‫ﻧﻮع ﺗﻮرﺑﻴﻦ و ﺗﻌﺪاد واﺣﺪ ﺻﻮرت ﮔﺮﻓﺘﻪ اﺳﺖ‪ .‬ﺑﺪﻳﻦ ﻣﻌﻨﻲ ﻛﻪ ﺑﺎ ﺗﺤﻠﻴﻞ ﺣﺴﺎﺳﺴﻴﺖ ﺳﻴﺴﺘﻢ ﺑﻪ ﻧﻮع ﺗﻮرﺑﻴﻦ و ﺗﻌﺪاد واﺣﺪ‪ ،‬ﻣﻴﺰان‬
‫ﺗﻮﻟﻴﺪ اﻧﺮژي ﺑﺮﻗﺎﺑﻲ ﻛﻞ ﺑﺮرﺳﻲ و ﻣﻘﺎﻳﺴﻪ ﺷﺪه اﺳﺖ‪.‬‬

‫ﻓﺮﺿﻴﺎﺗﻲ ﻛﻪ در ﺷﺒﻴﻪ ﺳﺎزي ﺳﻴﺴﺘﻢ ﻣﻮرد ﻧﻈﺮ ﺑﻮده اﺳﺖ‪.‬‬

‫‪ -1‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ اﻳﻨﻜﻪ ﻫﺪف از اﺣﺪاث ﻧﻴﺮوﮔﺎه ﻛﻮﭼﻚ‪ ،‬ﺗﻮﻟﻴﺪ ﺑﺮق ﺑﺮ اﺳﺎس ﻇﺮﻓﻴﺖ دﺑﻲ ﺧﻂ اﻧﺘﻘﺎل ﻣﻲ ﺑﺎﺷﺪ‪ ،‬اﮔﺮ دﺑﻲ‬
‫ﻃﺮاﺣﻲ ﻛﻮﭼﻜﺘﺮ از ﻇﺰﻓﻴﺖ ﺧﻂ ﺑﺎﺷﺪ ﻣﺒﻨﺎي ﻣﺤﺎﺳﺒﻪ اﻧﺮژي دﺑﻲ ﻃﺮاﺣﻲ ﺧﻮاﻫﺪ ﺑﻮد‪ .‬در ﻏﻴﺮ اﻳﻨﺼﻮرت ﻣﺒﻨﺎ ﻇﺮﻓﻴﺖ‬
‫ﻣﻮﺟﻮد در ﺧﻂ اﻧﺘﻘﺎل ﺧﻮاﻫﺪ ﺑﻮد‪.‬‬
‫‪ -2‬ﺗﻮﻟﻴﺪ اﻧﺮژي ﺑﺼﻮرت ﭘﺎﻳﻪ و ‪ 24‬ﺳﺎﻋﺘﻪ اﻧﺠﺎم ﻣﻴﺸﻮد و ﺗﻮﻟﻴﺪ ﺑﺮق از اﻫﺪاف ﺛﺎﻧﻮﻳﻪ ﺧﻂ ﺧﻮاﻫﺪ ﺑﻮد‪.‬‬
‫‪ -3‬ﻣﺤﺪوده ﺗﻐﻴﻴﺮات دﺑﻲ از ‪ 0/5‬ﺗﺎ ‪ 3‬ﻣﺘﺮ ﻣﻜﻌﺐ ﺑﺮ ﺛﺎﻧﻴﻪ ﻣﻄﺎﺑﻖ ﺟﺪول)‪ (1‬در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﺪه اﺳﺖ‪.‬‬
‫‪ -4‬راﻧﺪﻣﺎن ﻧﻴﺮوﮔﺎه ﻣﻌﺎدل ‪ 0/877‬ﻓﺮض ﺷﺪه اﺳﺖ‪.‬‬
‫‪ -5‬ﺿﺮﻳﺐ ﺣﺪاﻛﺜﺮ دﺑﻲ و ﺣﺪاﻗﻞ دﺑﻲ ﺑﻪ ﺗﺮﺗﻴﺐ ﺑﺮاﺑﺮ ﺑﺎ ‪ 1/1‬و ‪ 0/5‬ﺑﺮاي ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ و ‪ 1/1‬و ‪ 0/25‬ﺑﺮاي ﺗﻮرﺑﻴﻦ‬
‫ﭘﻠﺘﻦ ﻣﻨﻈﻮر ﺷﺪه اﺳﺖ‪.‬‬
‫‪ -6‬ﺿﺮﻳﺐ ﺣﺪاﻛﺜﺮ ﻫﺪ و ﺣﺪاﻗﻞ ﻫﺪ ﺑﻪ ﺗﺮﺗﻴﺐ ﺑﺮاﺑﺮ ﺑﺎ ‪ 1/25‬و ‪ 0/65‬ﺑﺮاي ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ و ﭘﻠﺘﻦ ﺗﻌﻴﻴﻦ ﺷﺪه اﺳﺖ‪.‬‬

‫‪١٢‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -1-6‬ﺷﺒﻴﻪ ﺳﺎزي‬
‫ﻓﺮاﻳﻨﺪ ﺷﺒﻴﻪ ﺳﺎزي ﻫﻴﺪرو اﻧﺮژي ﺑﺎ در ﻧﻈﺮ ﮔﺮﻓﺘﻦ ﻓﺮﺿﻴﺎت ﻣﺤﺎﺳﺒﻪ ﺑﺎ ﺗﻌﺮﻳﻒ ﺳﻨﺎرﻳﻮ ﻫﺎي ﻣﺨﺘﻠﻒ اﻧﺠﺎم ﻣﻴﮕﻴﺮد‪ .‬ﻧﻈﺮ ﺑﻪ اﻳﻨﻜﻪ‬
‫داﻣﻨﻪ اﻧﺘﺨﺎب دﺑﻲ ﻣﻄﺎﺑﻖ ﺑﺎ ﺟﺪول)‪ (1‬ﻣﺤﺪود ﺷﺪه‪ ،‬ﺑﻨﺎﺑﺮاﻳﻦ ﺑﺎزاي ﻫﺮ ﻳﻚ از دﺑﻲ ﻫﺎ ﻳﻚ ﺳﻨﺎرﻳﻮ ﺗﻌﺮﻳﻒ ﻣﻴﮕﺮدد و در ﻧﻬﺎﻳﺖ‬
‫ﮔﺰﻳﻨﻪ ﺑﺮﺗﺮ ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺣﺪاﻛﺜﺮ ﻣﻴﺰان ﺗﻮﻟﻴﺪ اﻧﺮژي در ﺟﺪول )‪ (26‬ﻣﺸﺨﺺ ﺷﺪه اﺳﺖ‪ .‬ﻧﺘﺎﻳﺞ ﻣﺤﺎﺳﺎت در ﮔﺰﻳﻨﻪ ﻫﺎي ﻣﺨﺘﻠﻒ در‬
‫ﺟﺪاول)‪ (2‬ﺗﺎ )‪ (25‬ﺑﻪ ﺗﻔﻜﻴﻚ اراﻳﻪ ﺷﺪه اﺳﺖ‪.‬‬

‫اﻧﺮژي ﺗﻮﻟﻴﺪي در ﻧﻴﺮوﮔﺎه ﺑﻪ ﻇﺮﻓﻴﺖ ﻧﺼﺐ‪ ،‬راﻧﺪﻣﺎن و ﺿﺮﻳﺐ ﻛﺎرﻛﺮد ﻧﻴﺮوﮔﺎه از ﻳﻚ ﻃﺮف و ارﺗﻔﺎع ﻫﻴﺪروﻟﻴﻜﻲ از ﻃﺮف‬
‫دﻳﮕﺮ ﺑﺴﺘﮕﻲ دارد‪.‬‬

‫راﺑﻄﻪ اﺻﻠﻲ ﺗﻮان در ﻣﺤﺎﺳﺒﺎت اﻧﺮژي ﻋﺒﺎرﺗﺴﺖ از‪:‬‬

‫‪Pt=γQtHte/1000‬‬

‫‪ :Pt‬ﺗﻮان ﺗﻮﻟﻴﺪ ﺷﺪه در دوره ‪ t‬ﺑﻪ ﻛﻴﻠﻮ وات‬

‫‪ :γ‬وزن ﻣﺨﺼﻮص آب)ﻣﻌﺎدل ‪ 9810‬ﻛﻴﻠﻮ ﻧﻴﻮﺗﻦ ﺑﺮ ﻣﺘﺮ ﻣﻜﻌﺐ(‬

‫‪ :Qt‬دﺑﻲ ورودب ﺑﻪ ﺗﻮرﺑﻴﻦ در ﻃﻲ دوره ‪t‬‬

‫‪ :Ht‬ارﺗﻔﺎع ﻫﻴﺪروﻟﻴﻜﻲ ﺧﺎﻟﺺ)ﻫﺪ ﻣﻮﺛﺮ( آب روي ﺗﻮرﺑﻴﻦ در ﻃﻲ دوره ف ﺑﻪ ﻣﺘﺮ‬

‫‪ :e‬راﻧﺪﻣﺎن ﻛﻠﻲ ﻧﻴﺮوﮔﺎه‬

‫ﺑﻌﻼوه ﻣﺤﺪودﻳﺖ ﻫﺎي زﻳﺮ ﺑﺮ ﺗﻮﻟﻴﺪ اﻧﺮژي ﺗﺎﺛﻴﺮ ﺧﻮاﻫﺪ ﮔﺬاﺷﺖ‪:‬‬

‫‪Pt<PPC‬‬

‫‪Qmin<Qt<Qmax‬‬

‫‪Hmin<Ht<Hmax‬‬

‫که در آنھا‬

‫‪ :PPC‬ﻇﺮﻓﻴﺖ ﻧﺼﺐ ﻧﻴﺮوﮔﺎه ﺑﻪ ﻛﻴﻠﻮ وات‬

‫‪ :Qmin‬ﺣﺪاﻗﻞ دﺑﻲ ﻣﺠﺎز ورودي ﺑﻪ ﺗﻮرﺑﻴﻦ)‪(CMS‬‬

‫‪ :Qmax‬ﺣﺪاﻛﺜﺮ دﺑﻲ ﻣﺠﺎز ورودي ﺑﻪ ﺗﻮرﺑﻴﻦ)‪(CMS‬‬

‫‪ :Hmin‬ﺣﺪاﻗﻞ ﻫﺪ ﻣﺠﺎز ورودي روي ﺗﻮرﺑﻴﻦ)ﻣﺘﺮ(‬

‫‪١٣‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ :Hmax‬ﺣﺪاﻛﺜﺮ ﻫﺪ ﻣﺠﺎز روي ﺗﻮرﺑﻴﻦ)ﻣﺘﺮ(‬

‫ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻧﻮع ﺗﻮرﺑﻴﻦ ﻧﻴﺮوﮔﺎه ﻧﺴﺒﺖ دﺑﻲ ﺣﺪاﻗﻞ ﺑﻪ دﺑﻲ ﻏﺎﻟﺐ)‪ (Rated Discharge‬ﺗﻮرﺑﻴﻦ ‪ 0/5‬و ﻫﻤﭽﻨﻴﻦ ﻧﺴﺒﺖ‬
‫ﻫﺪ ﺣﺪاﻗﻞ و ﺣﺪاﻛﺜﺮ ﺑﻪ ﻫﺪ ﻏﺎﻟﺐ ﺑﻪ ﺗﺮﺗﻴﺐ ‪ 0/65‬و‪ 1/25‬ﻣﻲ ﺑﺎﺷﻨﺪ‪ .‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻇﺮﻓﻴﺖ اﻧﺘﻘﺎل ﺧﻂ و ﻣﺤﺪودﻳﺖ ﻫﺎي‬
‫ﺗﻮﻟﻴﺪ اﻧﺮژي ﻣﺎﻧﻨﺪ رﻗﻮم ﺣﺪاﻗﻞ ﺑﻬﺮه ﺑﺮداري و ﻳﺎ دﺑﻲ ﺣﺪاﻗﻞ ﻣﻴﺰان ﺗﻮﻟﻴﺪ اﻧﺮژي ﻧﻴﺮوﮔﺎه ﻫﺎي ﻗﻄﻌﻪ ﺳﻮم و ﭼﻬﺎرم‬
‫ﻣﺤﺎﺳﺒﻪ ﺷﺪه اﺳﺖ‪ .‬ﺑﺮ اﻳﻦ اﺳﺎس ﻣﺪل ﺷﺒﻴﻪ ﺳﺎزي ﻧﻴﺮوﮔﺎه ﻫﺎ ﺗﻬﻴﻪ و ﭘﺲ ازﻛﺎﻟﻴﺒﺮاﺳﻴﻮن ﻣﺪل ﻣﻮرد اﺳﺘﻔﺎده ﻗﺮار ﮔﺮﻓﺘﻪ‬
‫اﺳﺖ‪.‬‬

‫در ﺷﺒﻴﻪ ﺳﺎزي ﺑﺎ اﺳﺘﻔﺎده از ﺑﺮﻧﺎﻣﻪ ﻧﻮﻳﺴﻲ در ﻣﺤﻴﻂ ‪ MARCO‬ﻧﺮم اﻓﺰار ‪ EXCEL‬ﺑﺎزاي ﺳﻨﺎرﻳﻮﻫﺎي ﺗﻌﺮﻳﻒ ﺷﺪه‬
‫رواﺑﻂ ﺣﺎﻛﻢ ﻣﺤﺎﺳﺒﻪ ﻇﺮﻓﻴﺖ و اﻧﺮزي ﺗﻌﺮﻳﻒ ﺷﺪه اﺳﺖ‪ .‬ﺑﺪﻳﻨﺼﻮرت ﻛﻪ در ﻫﺮ ﮔﺰﻳﻨﻪ اﻧﺘﺨﺎب دﺑﻲ در ﻣﺤﺪودﻳﺖ ﻫﺎي‬
‫ﻣﺮﺑﻮط ﺑﻪ دﺑﻲ و ارﺗﻔﺎع در ﺷﺮاﻳﻂ ﺑﻬﺮه ﺑﺮداري دﻳﺪه ﻣﻲ ﺷﻮد‪ .‬ﻧﺘﺎﻳﺞ آن در ﺟﺪاول)‪ (2‬ﺗﺎ )‪ (25‬اراﻳﻪ ﺷﺪه اﺳﺖ‪.‬‬

‫‪١۴‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪ -(٢‬خالصه نتايج محاسبات انرژی بازای دبی ‪ ٠/۵‬متر مکعب بر ثانيه – توربين فرانسيس دو واحدی‬

‫ﻫﺪ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻛﺜﺮ‬ ‫ﺗﻌﺪاد‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫واﺣﺪ‬ ‫‪Q=0.5cms‬‬

‫‪0.5‬‬ ‫‪215.51‬‬ ‫‪231.88‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪0.6‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪١۵‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(٣‬خالصه نتايج محاسبات انرژی بازای دبی ‪ ٠/۵‬متر مکعب بر ثانيه –توربين فرانسيس ‪ ٣‬واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬
‫‪Q=0.5cms‬‬
‫‪16.6666666‬‬
‫‪0.5‬‬ ‫‪215.51‬‬ ‫‪231.88‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪0.6‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫جدول)‪-(۴‬خالصه نتايج محاسبات انرژی بازای دبی ‪ ٠/۵‬متر مکعب بر ثانيه – توربين پلتن دو واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬ ‫‪Q=0.5cms‬‬

‫‪0.5‬‬ ‫‪215.51‬‬ ‫‪231.88‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪0.6‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪١۶‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(۵‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٠/۵‬متر مکعب بر ثانيه –توربين پلتن ‪ ٣‬واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬
‫‪Q=0.5cms‬‬
‫‪16.6666666‬‬
‫‪0.5‬‬ ‫‪215.51‬‬ ‫‪231.88‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪0.6‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫جدول)‪-(۶‬خالصه نتايج محاسبات انرژی بازای دبی ‪ ١‬متر مکعب بر ثانيه –توربين فرانسيس دو واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬ ‫‪Q=1cms‬‬

‫‪1‬‬ ‫‪222.52‬‬ ‫‪202.04‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬ ‫ﻗﻄﻌﻪ‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬ ‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪1.1‬‬ ‫‪0.5‬‬ ‫‪0.6‬‬ ‫‪3.6‬‬ ‫‪1.74‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪1.7‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪١٧‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(٧‬خالصه نتايج محاسبات انرژی بازای دبی ‪ ١‬متر مکعب بر ثانيه –توربين فرانسيس سه واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬
‫‪Q=1cms‬‬
‫‪16.6666666‬‬
‫‪1‬‬ ‫‪222.52‬‬ ‫‪202.04‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪1.1‬‬ ‫‪0.5‬‬ ‫‪0.6‬‬ ‫‪3.6‬‬ ‫‪1.74‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪1.7‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫جدول)‪-(٨‬خالصه نتايج محاسبات انرژی بازای دبی ‪ ١‬متر مکعب بر ثانيه –توربين پلتن دو واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬ ‫‪Q=1cms‬‬

‫‪1‬‬ ‫‪222.52‬‬ ‫‪202.04‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪1.1‬‬ ‫‪0.5‬‬ ‫‪0.6‬‬ ‫‪3.6‬‬ ‫‪1.74‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪1.7‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪١٨‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(٩‬خالصه نتايج محاسبات انرژی بازای دبی ‪ ١‬متر مکعب بر ثانيه –توربين پلتن سه واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬
‫‪Q=1cms‬‬
‫‪16.6666666‬‬
‫‪1‬‬ ‫‪222.52‬‬ ‫‪202.04‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪1.1‬‬ ‫‪0.5‬‬ ‫‪0.6‬‬ ‫‪3.6‬‬ ‫‪1.74‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪1.7‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫جدول)‪-(١٠‬خالصه نتايج محاسبات انرژی بازای دبی‪ ١/۵‬متر مکعب بر ثانيه –توربين فرانسيس سه واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬
‫‪Q=1.5cms‬‬
‫‪16.6666666‬‬
‫‪1.5‬‬ ‫‪206.92‬‬ ‫‪202.04‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪1.1‬‬ ‫‪0.5‬‬ ‫‪0.6‬‬ ‫‪3.6‬‬ ‫‪1.74‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪1.6‬‬ ‫‪0.8‬‬ ‫‪0.8‬‬ ‫‪5.3‬‬ ‫‪2.60‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪3.4‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪١٩‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(١١‬خالصه نتايج محاسبات انرژی بازای دبی‪ ١/۵‬متر مکعب بر ثانيه –توربين فرانسيس دو واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬ ‫‪Q=1.5cms‬‬

‫‪1.5‬‬ ‫‪206.92‬‬ ‫‪202.04‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪1.1‬‬ ‫‪0.5‬‬ ‫‪0.6‬‬ ‫‪3.6‬‬ ‫‪1.74‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪1.6‬‬ ‫‪0.8‬‬ ‫‪0.8‬‬ ‫‪5.3‬‬ ‫‪2.60‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪3.4‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫جدول)‪-(١٢‬خالصه نتايج محاسبات انرژی بازای دبی‪ ١/۵‬متر مکعب بر ثانيه –توربين پلتن سه واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬ ‫ﺗﻌﺪاد‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫واﺣﺪ‬
‫‪Q=1.5cms‬‬
‫‪16.6666666‬‬
‫‪1.5‬‬ ‫‪206.92‬‬ ‫‪202.04‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬ ‫ردﻳ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬ ‫ﻗﻄﻌﻪ‬ ‫ف‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬ ‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪1.1‬‬ ‫‪0.5‬‬ ‫‪0.6‬‬ ‫‪3.6‬‬ ‫‪1.74‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪1.6‬‬ ‫‪0.8‬‬ ‫‪0.8‬‬ ‫‪5.3‬‬ ‫‪2.60‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪3.4‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪٢٠‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(١٣‬خالصه نتايج محاسبات انرژی بازای دبی‪ ١/۵‬متر مکعب بر ثانيه –توربين پلتن دو واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬ ‫‪Q=1.5cms‬‬

‫‪1.5‬‬ ‫‪206.92‬‬ ‫‪202.04‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.6‬‬ ‫‪0.3‬‬ ‫‪0.3‬‬ ‫‪1.9‬‬ ‫‪1.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪1.1‬‬ ‫‪0.5‬‬ ‫‪0.6‬‬ ‫‪3.6‬‬ ‫‪1.74‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪1.6‬‬ ‫‪0.8‬‬ ‫‪0.8‬‬ ‫‪5.3‬‬ ‫‪2.60‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪3.4‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫جدول)‪-(١۴‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٢‬متر مکعب بر ثانيه –توربين فرانسيس سه واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬
‫‪Q=2cms‬‬
‫‪16.6666666‬‬
‫‪2‬‬ ‫‪185.08‬‬ ‫‪148.18‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.3‬‬ ‫‪0.0‬‬ ‫‪0.3‬‬ ‫‪0.9‬‬ ‫‪0.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.6‬‬ ‫‪0.0‬‬ ‫‪0.6‬‬ ‫‪1.9‬‬ ‫‪0.00‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.8‬‬ ‫‪0.0‬‬ ‫‪0.8‬‬ ‫‪2.7‬‬ ‫‪0.00‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪41.2‬‬ ‫‪18.3‬‬ ‫‪22.9‬‬ ‫‪5.7‬‬ ‫‪2.55‬‬ ‫‪3.18‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪43.0‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪٢١‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(١۵‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٢‬متر مکعب بر ثانيه –توربين فرانسيس دو واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬ ‫‪Q=2cms‬‬

‫‪2‬‬ ‫‪185.08‬‬ ‫‪148.18‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.3‬‬ ‫‪0.0‬‬ ‫‪0.3‬‬ ‫‪0.9‬‬ ‫‪0.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.6‬‬ ‫‪0.0‬‬ ‫‪0.6‬‬ ‫‪1.9‬‬ ‫‪0.00‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.8‬‬ ‫‪0.0‬‬ ‫‪0.8‬‬ ‫‪2.7‬‬ ‫‪0.00‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪41.2‬‬ ‫‪18.3‬‬ ‫‪22.9‬‬ ‫‪5.7‬‬ ‫‪2.55‬‬ ‫‪3.18‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪43.0‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫جدول)‪-(١۶‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٢‬متر مکعب بر ثانيه –توربين پلتن سه واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬
‫‪Q=2cms‬‬
‫‪16.6666666‬‬
‫‪2‬‬ ‫‪185.08‬‬ ‫‪148.18‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬ ‫ﻗﻄﻌﻪ‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬ ‫ﭼﻬﺎرم‬

‫‪0.3‬‬ ‫‪0.0‬‬ ‫‪0.3‬‬ ‫‪0.9‬‬ ‫‪0.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.6‬‬ ‫‪0.0‬‬ ‫‪0.6‬‬ ‫‪1.9‬‬ ‫‪0.00‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.8‬‬ ‫‪0.0‬‬ ‫‪0.8‬‬ ‫‪2.7‬‬ ‫‪0.00‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪41.2‬‬ ‫‪18.3‬‬ ‫‪22.9‬‬ ‫‪5.7‬‬ ‫‪2.55‬‬ ‫‪3.18‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪43.0‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪٢٢‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(١٧‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٢‬متر مکعب بر ثانيه –توربين پلتن دو واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬ ‫‪Q=2cms‬‬

‫‪2‬‬ ‫‪185.08‬‬ ‫‪148.18‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬ ‫ﻗﻄﻌﻪ‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬ ‫ﭼﻬﺎرم‬

‫‪0.3‬‬ ‫‪0.0‬‬ ‫‪0.3‬‬ ‫‪0.9‬‬ ‫‪0.00‬‬ ‫‪0.93‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.6‬‬ ‫‪0.0‬‬ ‫‪0.6‬‬ ‫‪1.9‬‬ ‫‪0.00‬‬ ‫‪1.91‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.8‬‬ ‫‪0.0‬‬ ‫‪0.8‬‬ ‫‪2.7‬‬ ‫‪0.00‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪41.2‬‬ ‫‪18.3‬‬ ‫‪22.9‬‬ ‫‪5.7‬‬ ‫‪2.55‬‬ ‫‪3.18‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪43.0‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫جدول)‪-(١٨‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٢/۵‬متر مکعب بر ثانيه –توربين فرانسيس سه واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬
‫‪Q=2.5cms‬‬
‫‪16.6666666‬‬
‫‪2.5‬‬ ‫‪156.99‬‬ ‫‪107.78‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.8‬‬ ‫‪0.0‬‬ ‫‪0.8‬‬ ‫‪2.7‬‬ ‫‪0.00‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪22.9‬‬ ‫‪0.0‬‬ ‫‪22.9‬‬ ‫‪3.2‬‬ ‫‪0.00‬‬ ‫‪3.18‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪1.8‬‬ ‫‪0.7‬‬ ‫‪1.1‬‬ ‫‪5.7‬‬ ‫‪2.32‬‬ ‫‪3.37‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪25.5‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪٢٣‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(١٩‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٢/۵‬متر مکعب بر ثانيه –توربين فرانسيس دو واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬ ‫‪Q=2.5cms‬‬

‫‪2.5‬‬ ‫‪156.99‬‬ ‫‪107.78‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.8‬‬ ‫‪0.0‬‬ ‫‪0.8‬‬ ‫‪2.7‬‬ ‫‪0.00‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪22.9‬‬ ‫‪0.0‬‬ ‫‪22.9‬‬ ‫‪3.2‬‬ ‫‪0.00‬‬ ‫‪3.18‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪1.8‬‬ ‫‪0.7‬‬ ‫‪1.1‬‬ ‫‪5.7‬‬ ‫‪2.32‬‬ ‫‪3.37‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪25.5‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫جدول)‪-(٢٠‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٢/۵‬متر مکعب بر ثانيه –توربين پلتن سه واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬
‫‪Q=2.5cms‬‬
‫‪16.6666666‬‬
‫‪2.5‬‬ ‫‪156.99‬‬ ‫‪107.78‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.8‬‬ ‫‪0.0‬‬ ‫‪0.8‬‬ ‫‪2.7‬‬ ‫‪0.00‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪22.9‬‬ ‫‪0.0‬‬ ‫‪22.9‬‬ ‫‪3.2‬‬ ‫‪0.00‬‬ ‫‪3.18‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪1.8‬‬ ‫‪0.7‬‬ ‫‪1.1‬‬ ‫‪5.7‬‬ ‫‪2.32‬‬ ‫‪3.37‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪25.5‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪٢۴‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(٢١‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٢/۵‬متر مکعب بر ثانيه –توربين پلتن دو واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬ ‫‪Q=2.5cms‬‬

‫‪2.5‬‬ ‫‪156.99‬‬ ‫‪107.78‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.8‬‬ ‫‪0.0‬‬ ‫‪0.8‬‬ ‫‪2.7‬‬ ‫‪0.00‬‬ ‫‪2.67‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪22.9‬‬ ‫‪0.0‬‬ ‫‪22.9‬‬ ‫‪3.2‬‬ ‫‪0.00‬‬ ‫‪3.18‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪1.8‬‬ ‫‪0.7‬‬ ‫‪1.1‬‬ ‫‪5.7‬‬ ‫‪2.32‬‬ ‫‪3.37‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪25.5‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫جدول)‪-(٢٢‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٣‬متر مکعب بر ثانيه –توربين فرانسيس سه واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬
‫‪Q=3cms‬‬
‫‪16.6666666‬‬
‫‪3‬‬ ‫‪112.67‬‬ ‫‪58.40‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪1.4‬‬ ‫‪0.5‬‬ ‫‪0.9‬‬ ‫‪4.4‬‬ ‫‪1.51‬‬ ‫‪2.91‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪1.4‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪٢۵‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(٢٣‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٣‬متر مکعب بر ثانيه –توربين فرانسيس دو واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬ ‫‪Q=3cms‬‬

‫‪3‬‬ ‫‪112.67‬‬ ‫‪58.40‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﻓﺮاﻧﺴﻴﺲ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪1.4‬‬ ‫‪0.5‬‬ ‫‪0.9‬‬ ‫‪4.4‬‬ ‫‪1.51‬‬ ‫‪2.91‬‬ ‫‪58.40‬‬ ‫‪112.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪1.4‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫جدول)‪-(٢۴‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٣‬متر مکعب بر ثانيه –توربين پلتن سه واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬
‫‪Q=3cms‬‬
‫‪16.6666666‬‬
‫‪3‬‬ ‫‪122.67‬‬ ‫‪58.40‬‬ ‫‪110‬‬ ‫‪7‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪3‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪1.1‬‬ ‫‪0.0‬‬ ‫‪1.1‬‬ ‫‪3.4‬‬ ‫‪0.00‬‬ ‫‪3.37‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪1.5‬‬ ‫‪0.5‬‬ ‫‪1.0‬‬ ‫‪4.7‬‬ ‫‪1.51‬‬ ‫‪3.16‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪2.5‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪٢۶‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫جدول)‪-(٢۵‬خالصه نتايج محاسبات انرژی بازای دبی‪ ٣‬متر مکعب بر ثانيه –توربين پلتن دو واحدی‬

‫ﻫﺪ‬ ‫ﺿﺮﻳﺐ‬
‫ﻫﺪ ﻃﺮاﺣﻲ‬
‫‪Qd‬‬ ‫ﻃﺮاﺣﻲ‪m)4‬‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ دﺑﻲ‬ ‫ﺿﺮﻳﺐ ﺣﺪاﻗﻞ‬ ‫ﺣﺪاﻛﺜﺮ‬
‫‪(m)3‬‬ ‫ﮔﺰﻳﻨﻪ دوم‪ -‬دو واﺣﺪي‬
‫(‬ ‫ﺣﺪاﻛﺜﺮ)‪(%‬‬ ‫ﺣﺪاﻗﻞ)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ارﺗﻔﺎع)‪(%‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬ ‫‪Q=3cms‬‬

‫‪3‬‬ ‫‪122.67‬‬ ‫‪58.40‬‬ ‫‪110‬‬ ‫‪25‬‬ ‫‪65‬‬ ‫‪135‬‬ ‫‪2‬‬

‫ﻧﻮع ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ‬

‫ﺟﻤﻊ‬ ‫اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬ ‫ﻇﺮﻓﻴﺖ)‪(MW‬‬ ‫ﻫﺪ)‪(M‬‬


‫ﺟﻤﻊ ﻛﻞ‬
‫اﻧﺮژي)‪GWH‬‬ ‫دﺑﻲ)‪(CMS‬‬ ‫ردﻳﻒ‬
‫ﻗﻄﻌﻪ‬ ‫ﺗﻮان)‪(MW‬‬
‫(‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬
‫ﭼﻬﺎرم‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪231.88‬‬ ‫‪215.51‬‬ ‫‪0.5‬‬ ‫‪1‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪222.52‬‬ ‫‪1‬‬ ‫‪2‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪202.04‬‬ ‫‪206.92‬‬ ‫‪1.5‬‬ ‫‪3‬‬

‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.0‬‬ ‫‪0.00‬‬ ‫‪0.00‬‬ ‫‪148.18‬‬ ‫‪185.08‬‬ ‫‪2‬‬ ‫‪4‬‬

‫‪1.1‬‬ ‫‪0.0‬‬ ‫‪1.1‬‬ ‫‪3.4‬‬ ‫‪0.00‬‬ ‫‪3.37‬‬ ‫‪107.78‬‬ ‫‪156.99‬‬ ‫‪2.5‬‬ ‫‪5‬‬

‫‪1.5‬‬ ‫‪0.5‬‬ ‫‪1.0‬‬ ‫‪4.7‬‬ ‫‪1.51‬‬ ‫‪3.16‬‬ ‫‪58.40‬‬ ‫‪122.67‬‬ ‫‪3‬‬ ‫‪6‬‬

‫‪2.5‬‬ ‫ﺟﻤﻊ ﻛﻞ اﻧﺮژي ﺗﻮﻟﻴﺪي)‪(GWH‬‬

‫‪٢٧‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -7‬ﻣﻘﺎﻳﺴﻪ ﻧﺘﺎﻳﺞ‬
‫ﻣﻄﺎﺑﻖ ﺑﺎ ﻧﺘﺎﻳﺞ ﺟﺪول)‪ (26‬ﮔﺰﻳﻨﻪ ﭘﻠﺘﻦ ﺑﺎ دﺑﻲ ﻃﺮاﺣﻲ ‪ 2‬ﻣﺘﺮ ﻣﻜﻌﺐ ﺑﺮ ﺛﺎﻧﻴﻪ ﺑﺎﻻ ﺗﺮﻳﻦ ﻣﻴﺰان ﺗﻮﻟﻴﺪ اﻧﺮژي را ﻧﺸﺎن ﻣﻴﺪﻫﺪ‪ .‬از‬

‫اﻳﻨﺮو ﻣﺒﻨﺎي ﻃﺮاﺣﻲ ﺗﺠﻬﻴﺰات ﻫﻴﺪرو ﻣﻜﺎﻧﻴﻚ ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻦ ﺑﺎ دﺑﻲ ﻃﺮاﺣﻲ ‪ 2‬ﻣﺘﺮ ﻣﻜﻌﺐ ﺑﺮ ﺛﺎﻧﻴﻪ ﺑﺎ ارﺗﻔﺎع ﺧﺎﻟﺺ ‪ 185/08‬ﺑﺮاي‬

‫ﻗﻄﻌﻪ ﺳﻮم و ‪ 162/54‬در ﻗﻄﻌﻪ ﭼﻬﺎرم اﻧﺘﺨﺎب ﺷﺪه اﺳﺖ‪.‬‬

‫ﺟﺪول)‪ -(26‬ﺧﻼﺻﻪ ﻧﺘﺎﻳﺞ ﻣﻘﺎﻳﺴﻪ ﺑﻴﻦ ﺳﻨﺎرﻳﻮ ﻫﺎي ﺗﻮﻟﻴﺪ‬

‫ﻓﺮاﻧﺴﻴﺲ‬ ‫ﭘﻠﺘﻦ‬
‫‪Qd‬‬
‫دو واﺣﺪي‬ ‫ﺳﻪ واﺣﺪي‬ ‫دو واﺣﺪي‬ ‫ﺳﻪ واﺣﺪي‬

‫‪0.5‬‬ ‫‪0.6‬‬ ‫‪0.6‬‬ ‫‪0.6‬‬ ‫‪0.6‬‬


‫‪1‬‬ ‫‪1.7‬‬ ‫‪1.7‬‬ ‫‪1.7‬‬ ‫‪1.7‬‬
‫‪1.5‬‬ ‫‪3.4‬‬ ‫‪3.4‬‬ ‫‪3.4‬‬ ‫‪3.4‬‬
‫‪2‬‬ ‫‪43.0‬‬ ‫‪43.0‬‬ ‫‪43.0‬‬ ‫‪43.0‬‬
‫‪2.5‬‬ ‫‪25.5‬‬ ‫‪25.5‬‬ ‫‪25.5‬‬ ‫‪25.5‬‬
‫‪3‬‬ ‫‪1.4‬‬ ‫‪1.4‬‬ ‫‪2.5‬‬ ‫‪2.5‬‬

‫‪٢٨‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪-8‬ﺗﺠﻬﻴﺰات ﻧﻴﺮوﮔﺎه‬
‫‪-1-8‬ﻣﺒﺎﻧﻲ ﻃﺮاﺣﻲ‬

‫ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ وﺟﻮد ﭘﺘﺎﻧﺴﻴﻞ ﻗﺎﺑﻞ ﺗﻮﺟﻪ در ﻣﺴﻴﺮ ﺧﻂ اﻧﺘﻘﺎل ‪،‬ﮔﺰﻳﻨﻪ ﻫﺎي ﻣﺘﻔﺎوﺗﻲ ﺑﺮاي ﭘﺮوژه ﻧﻴﺮوﮔﺎﻫﻬﺎي ﺧﻂ اﻧﺘﻘﺎل ﺳﺪ ﺻﻔﺎ رود‬

‫ﻣﻄﺮح و ﺑﺮرﺳﻲ ﺷﺪه اﻧﺪ‪ ،‬ﻛﻪ ﻣﻄﺎﺑﻖ ﺑﺮرﺳﻲ ﺑﺨﺶ ﻫﻴﺪروﻟﻴﻚ ﮔﺰﻳﻨﻪ ﻫﺎي ﺑﺮﺗﺮ ﺟﻬﺖ ﻗﻄﻌﻪ ﺳﻮم و ﭼﻬﺎرم اﻧﺘﺨﺎب ﺷﺪه ‪ ،‬و ﺑﺮ اﻳﻦ‬

‫اﺳﺎس دﺑﻲ ﻃﺮاﺣﻲ ﺗﻌﻴﻴﻦ ﮔﺮدﻳﺪه اﺳﺖ ‪ .‬در ﮔﺰارش ذﻳﻞ ﻣﺸﺮوح ﻣﻄﺎﻟﻌﺎت اﻧﺠﺎم ﮔﺮﻓﺘﻪ ﻣﺮﺑﻮط ﺑﻪ ﮔﺰﻳﻨﻪ ﺑﺮﺗﺮ ﻣﻲ ﺑﺎﺷﺪ‪:‬‬

‫دﺑﻲ ﻃﺮاﺣﻲ ﻣﺮﺑﻮط ﺑﻪ ﻗﻄﻌﺎت ﺳﻮم و ﭼﻬﺎرم ‪ 2 :‬ﻣﺘﺮ ﻣﻜﻌﺐ ﺑﺮ ﺛﺎﻧﻴﻪ‬

‫ﮔﺰﻳﻨﻪ ﺑﺮﺗﺮﻗﻄﻌﻪ ﺳﻮم ‪ ،‬ﻧﻴﺮوﮔﺎه رو زﻣﻴﻨﻲ ﺑﺎ ﻇﺮﻓﻴﺖ ‪ 3212‬ﻛﻴﻠﻮ وات‬

‫ﮔﺰﻳﻨﻪ ﺑﺮﺗﺮﻗﻄﻌﻪ ﭼﻬﺎرم ‪ ،‬ﻧﻴﺮوﮔﺎه رو زﻣﻴﻨﻲ ﺑﺎ ﻇﺮﻓﻴﺖ ‪ 2840‬ﻛﻴﻠﻮ وات‬

‫‪ -2-8‬ﻛﻠﻴﺎت ﻃﺮح‬
‫ﻫﻤﺎﻧﮕﻮﻧﻪ ﻛﻪ در اداﻣﻪ ﺑﻪ آن ﭘﺮداﺧﺖ ﻣﻲ ﺷﻮد ﺑﺮاي ﻫﺮ ﻧﻴﺮوﮔﺎه دو واﺣﺪ ﺗﻮرﺑﻴﻦ – ژﻧﺮاﺗﻮر در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﺪه اﺳﺖ‪ .‬ﺑﺮاي‬

‫دﺳﺘﻴﺎﺑﻲ ﺑﻪ ﺣﺪاﻛﺜﺮ اﻧﺮژي و ﻛﺎرﻛﺮد در ﺷﺮاﻳﻂ ﻣﺠﺎز ﺑﻬﺮه ﺑﺮداري ‪،‬ﺗﻮرﺑﻴﻦ ﻫﺎ ﻗﺎدر ﺧﻮاﻫﻨﺪ ﺑﻮد ﺑﻄﻮر ﻣﺪاوم در ﻣﻴﺰان ﮔﺸﻮدﮔﻲ‬

‫ﺣﺪاﻗﻞ و ﺣﺪاﻛﺜﺮ ﻧﺎزﻟﻬﺎ ﺑﺪون ﻫﻴﭽﮕﻮﻧﻪ ﻧﻮﺳﺎﻧﺎت‪ ،‬ارﺗﻌﺎﺷﺎت ﻣﻀﺮ ﻳﺎ ﺻﺪاي ﺧﺎرج از اﺳﺘﺎﻧﺪارد ‪ ،‬ﻣﻮرد ﺑﻬﺮه ﺑﺮداري ﻗﺮار ﮔﻴﺮﻧﺪ‪.‬‬

‫ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺑﺮرﺳﻲ ﻫﺎي ﺻﻮرت ﮔﺮﻓﺘﻪ‪ ،‬رﻗﻮم ﻧﺮﻣﺎل)ﺣﺪاﻗﻞ( )‪2360(m.a.s.l‬ﺑﺮاي اﺑﺘﺪاي ﻗﻄﻌﻪ ﺳﻮم و رﻗﻮم ارﺗﻔﺎﻋﻲ آب در‬

‫ورودي ﻣﺨﺰن ‪ 5000‬ﻣﺘﺮ ﻣﻜﻌﺒﻲ واﻗﻊ در اﻧﺘﻬﺎي ﻗﻄﻌﻪ ﺳﻮم و ﻫﻤﭽﻨﻴﻦ ﻛﺪ ارﺗﻔﺎﻋﻲ ‪ ( m.a.s.l)1915‬در اﻧﺘﻬﺎي ﻗﻄﻌﻪ ﭼﻬﺎرم‬

‫‪ ،‬ﻣﻄﺎﺑﻖ ﺑﺎ ﻃﻮل ﻗﻄﻌﻪ ﺳﻮم ﺑﻪ ﻣﻘﺪار ‪ 16525‬ﻣﺘﺮ و ﻃﻮل ﻗﻌﻪ ﭼﻬﺎرم ﺑﻪ ﻣﻘﺪار ‪ 23773‬ﻣﺘﺮ‪ ،‬و ﻫﻤﭽﻨﻴﻦ ﺑﺎﺗﻮﺟﻪ ﺑﻪ دﺑﻲ ﻃﺮاﺣﻲ ‪2‬‬

‫ﻣﺘﺮ ﻣﻜﻌﺒﻲ ‪ ،‬ارﺗﻔﺎع ﺧﺎﻟﺺ در دﺳﺘﺮس ﻗﻄﻌﻪ ﺳﻮم ‪ 185.08‬ﻣﺘﺮ و ﻗﻄﻌﻪ ﭼﻬﺎرم ‪ 162.54‬ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫‪٢٩‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫ﺟﺪول )‪ -(27‬ﺧﻼﺻﻪ ﻧﺘﺎﻳﺞ ﺑﻬﺮه ﺑﺮداري‬

‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻧﺎم ﻗﻄﻌﻪ‬

‫‪2135‬‬ ‫‪2370‬‬ ‫رﻗﻮم اﺑﺘﺪاي ﻗﻄﻌﻪ‪masl‬‬

‫‪1915‬‬ ‫‪2135‬‬ ‫رﻗﻮم اﻧﺘﻬﺎي ﻗﻄﻌﻪ‪masl‬‬

‫‪23773‬‬ ‫‪16525‬‬ ‫ﻃﻮل ﻣﺴﻴﺮ ‪m‬‬

‫‪1219‬‬ ‫‪1219‬‬ ‫ﻗﻄﺮ ﻧﺎﻣﻲ ‪mm‬‬

‫ﻓﻮﻻدي‬ ‫ﻓﻮﻻدي‬ ‫ﺟﻨﺲ‬

‫‪2840‬‬ ‫‪3212‬‬ ‫ﻇﺮﻓﻴﺖ ﻧﺼﺐ ﻧﻴﺮوﮔﺎه ‪KW‬‬

‫‪57‬‬ ‫‪39‬‬ ‫اﻓﺖ ﻫﺪ ‪m‬‬

‫‪2‬‬ ‫‪2‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬

‫‪162.54‬‬ ‫‪185.08‬‬ ‫ﻫﺪ ﻃﺮاﺣﻲ )ﺧﺎﻟﺺ( ‪m‬‬

‫‪162‬‬ ‫‪185‬‬ ‫ﻫﺪ ﺣﺪاﻗﻞ ‪m‬‬

‫‪162.54‬‬ ‫‪185.08‬‬ ‫ﻫﺪ ﺣﺪاﻛﺜﺮ‬

‫‪1‬‬ ‫‪1‬‬ ‫دﺑﻲ ﻃﺮاﺣﻲ ﻫﺮ واﺣﺪ‪m3/s‬‬

‫‪٣٠‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -2-8‬ﺗﻌﺪاد و ﻇﺮﻓﻴﺖ واﺣﺪﻫﺎ‬

‫ﭘﺲ از ﺗﻀﻤﻴـﻦ ﻛﻞ ﻇﺮﻓﻴﺖ ﻳﻚ ﻧﻴـﺮوﮔﺎه ﻻزم اﺳﺖ ﻣﺸﺨﺺ ﺷﻮد ﻛﻪ از ﭼﻪ ﺗﻌﺪاد واﺣﺪ و ﺑﺎ ﭼﻪ ﻇﺮﻓﻴﺖ ﻫﺎﻳﻲ ﺑﺎﻳﺴﺘﻲ اﺳﺘﻔﺎده‬

‫ﮔﺮدد‪ .‬ﻋﻮاﻣﻞ اﺻﻠﻲ ﻛﻪ ﺑﺮ اﻳﻦ اﻧﺘﺨﺎب ﺗﺎﺛﻴﺮ دارﻧﺪ‪ ،‬ﻋﺒﺎرﺗﻨﺪ از ﻫﺰﻳﻨﻪ ﻫﺎي اوﻟﻴﻪ‪ ،‬ﻫﺰﻳﻨﻪ ﻫﺎي ﺑﻬﺮه ﺑﺮداري و ‪. ...‬‬

‫ﻣﻌﻤﻮﻻً ﺑﺮاي ﻳﻚ ﻇﺮﻓﻴﺖ ﻛﻞ ﻣﻔﺮوض‪ ،‬ﺑﺎ ﻛﺎﻫﺶ ﺗﻌﺪاد واﺣﺪﻫﺎ‪ ،‬ﻫﺰﻳﻨﻪ ﻫﺎي ﻧﺼﺐ و راه اﻧﺪازي در ﻫﺮ ﻛﻴﻠﻮ وات ﻛﺎﻫﺶ ﻣﻲ ﻳﺎﺑﺪ‪.‬‬

‫ﺑﻪ ﻫﻤﻴﻦ ﺟﻬﺖ اﺳﺖ ﻛﻪ در ﺣﺎل ﺣﺎﺿﺮ ﺗﻤﺎﻳﻞ ﺑﻪ اﺳﺘﻔﺎده از از واﺣﺪﻫﺎي ﻛﻤﺘﺮ‪ ،‬اﻣﺎ ﭘﺮ ﻇﺮﻓﻴﺖ در ﻧﻴﺮوﮔﺎﻫﻬﺎي ﺑﺮﻗﺎﺑﻲ ﻣﺸﺎﻫﺪه ﻣﻲ‬

‫ﮔﺮدد‪ .‬ﺑﺎ اﻧﺘﺨﺎب ﻳﻚ واﺣﺪ در ﺻﻮرت ﺑﺮوز ﻫﺮ ﮔﻮﻧﻪ ﻣﺸﻜﻠﻲ در ﺗﻮرﺑﻴﻦ ژﻧﺮاﺗﻮر‪ ،‬ﻧﻴﺮوﮔﺎه ﻛﺎﻣﻼً ﻣﺘﻮﻗﻒ ﺧﻮاﻫﺪ ﺷﺪ و ﻫﻤﭽﻨﻴﻦ اﺑﻌﺎد‬

‫ﺗﻮرﺑﻴﻦ ژﻧﺮاﺗﻮر ﺑﺰرگ ﺷﺪه و از ﻧﻈﺮ ﺣﻤﻞ و ﻧﻘﻞ ﺗﺠﻬِﻴﺰات ﺑﻪ ﺳﺎﻳﺖ‪ ،‬ﻣﺸﻜﻼﺗﻲ را در ﺑﺮﺧﻮاﻫﺪ داﺷﺖ‪ .‬از ﺳﻮي دﻳﮕﺮ در ﺻﻮرت‬

‫اﻧﺘﺨﺎب ﺳﻪ واﺣﺪ‪ ،‬ﻗﺎﺑﻠﻴﺖ اﻃﻤﻴﻨﺎن ﺳﻴﺴﺘﻢ ﺑﻴﺸﺘﺮ ﺧﻮاﻫﺪ ﺷﺪ وﻟﻲ اﺑﻌﺎد ﻧﻴﺮوﮔﺎه ﺑﺰرﮔﺘﺮ ﺷﺪه و ﻫﺰﻳﻨﻪ ﻫﺎي ﺳﺎﺧﺘﻤﺎﻧﻲ و ﺗﺠﻬﻴﺰاﺗﻲ‬

‫ﺑﻴﺸﺘﺮي را در ﺑﺮ ﺧﻮاﻫﺪ داﺷﺖ‪.‬‬

‫در ﻳﻚ ﻧﻴﺮوﮔﺎه‪ ،‬ﺗﺮﺟﻴﺤﺎً واﺣﺪﻫﺎ ﺑﺎﻳﺴﺘﻲ ﻇﺮﻓﻴﺖ ﻣﺸﺎﺑﻬﻲ داﺷﺘﻪ ﺑﺎﺷﻨﺪ‪.‬ﺟﻬﺖ ﺑﻬﺮه ﺑﺮداري ﻣﻨﺎﺳﺐ ازﻃﺮﺣﻬﺎي ﺑﺮﻗﺎﺑﻲ ﺣﺪاﻗﻞ‬

‫ﺗﻌﺪاد واﺣﺪﻫﺎي ﻧﻴﺮوﮔﺎه ﺑﺎﻳﺴﺘﻲ ‪ 2‬واﺣﺪ ﺑﺎﺷﺪ ﺗﺎ در ﺻﻮرت ﺗﻌﻤﻴﺮات دوره اي و ﻳﺎ ﺗﻌﻮﻳﺾ ﻗﻄﻌﺎت ﺣﺪاﻗﻞ ﻳﻚ واﺣﺪ ﻧﻴﺮوﮔﺎه و ﻳﺎ ‪50‬‬

‫درﺻﺪ ﻇﺮﻓﻴﺖ ﻧﻴﺮوﮔﺎه ﻗﺎﺑﻠﻴﺖ ﺗﻮﻟﻴﺪ اﻧﺮژي و اﺗﺼﺎل ﺑﻪ ﺷﺒﻜﻪ ﺑﺮق را داﺷﺘﻪ ﺑﺎﺷﺪ‪ .‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺗﻮﺿﻴﺤﺎت ﻓﻮق ﺣﺪاﻗﻞ ﺗﻌﺪاد واﺣﺪ‬

‫ﻫﺎي در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﺪه در ﻫﺮ ﻧﻴﺮوﮔﺎه ‪ 2‬واﺣﺪ ﻣﻲ ﺑﺎﺷﺪ ‪.‬‬

‫‪ -3-8‬اﻧﺘﺨﺎب ﻧﻮع ﺗﻮرﺑﻴﻦ ‪ ،‬ﺳﺮﻋﺖ ﻣﺨﺼﻮص و دور ﻃﺮاﺣﻲ ﺗﻮرﺑﻴﻦ‬

‫از ﺷﻜﻞ زﻳﺮ ﺟﻬﺖ اﻧﺘﺨﺎب ﻧﻮع ﺗﻮرﺑﻴﻦ اﺳﺘﻔﺎده ﺷﺪه اﺳﺖ ‪ .‬در اﻳﻦ ﺷﻜﻞ ﻣﻲ ﺗﻮان ﻧﻮع ﺗﻮرﺑﻴﻦ را ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ دﺑﻲ و ارﺗﻔﺎع آب‬

‫ﺗﻌﻴﻴﻦ ﻧﻤﻮد‪ .‬ﺷﻜﻞ)‪(4‬‬

‫در اﻳﻦ ﻃﺮح‪ ،‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺷﻜﻞ )‪ (4‬و ﺷﺮاﻳﻂ و دادهﻫﺎي ﻃﺮاﺣﻲ ﻛﻪ ﺧﻼﺻﻪ ﻧﺘﺎﻳﺞ آن در ﺟﺪاول ذﻳﻞ اراﺋﻪ ﺷﺪه اﺳﺖ و ﻫﻤﭽﻨﻴﻦ ﺑﺎ‬

‫ﺑﻪﻛﺎرﮔﻴﺮي از ﺗﺠﺎرب ﻗﺒﻠﻲ در زﻣﻴﻨﻪ ﻃﺮاﺣﻲ ﻧﻴﺮوﮔﺎﻫﻬﺎي آﺑﻲ ‪ ،‬ﺗﻮرﺑﻴﻦﻫﺎي ﻧﻴﺮوﮔﺎه از ﻧﻮع ﭘﻠﺘﻮن اﻓﻘﻲ ﭘﻴﺸﻨﻬﺎد ﻣﻲﮔﺮدد‪.‬‬

‫‪٣١‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫ﺷﻜﻞ) ‪- (4‬اﻧﺘﺨﺎب ﻧﻮع ﺗﻮرﺑﻴﻦ ﺑﺮاﺳﺎس دﺑﻲ و ارﺗﻔﺎع‬

‫‪٣٢‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫ﺳﺮﻋﺖ ﻣﺨﺼﻮص ﺗﻮرﺑﻴﻦ از ﭘﺎراﻣﺘﺮﻫﺎي ﻣﻬﻢ در ﺑﺮرﺳﻲ و ﻃﺮاﺣﻲ ﺗﻮرﺑﻴﻦ ﻫﺎي آﺑﻲ ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫ﺗﻌﺮﻳﻒ ﻛﻪ در اﻳﻨﺠﺎ ﺑﻴﺎن ﻣﻲ ﮔﺮدد ﻋﺒﺎرت اﺳﺖ از‪:‬‬

‫‪1‬‬
‫) ‪n( Pd‬‬ ‫‪2‬‬
‫‪nS ‬‬ ‫‪5‬‬
‫) ‪( hd‬‬ ‫‪4‬‬

‫ﻛﻪ در اﻳﻦ راﺑﻄﻪ‪:‬‬

‫‪ :ns‬ﺳﺮﻋﺖ ﻣﺨﺼﻮص‬

‫‪ :n‬ﺳﺮﻋﺖ ﭼﺮﺧﺶ )‪(r pm‬‬

‫‪ :Pd‬ﺗﻮان ﺗﻮرﺑﻴﻦ در دﺑﻲ ﻛﺎﻣﻞ و ارﺗﻔﺎع ﻃﺮاﺣﻲ )‪(kw‬‬

‫‪ :hd‬ارﺗﻔﺎع ﻃﺮاﺣﻲ )‪(m‬‬

‫راﺑﻄﻪ ﻓﻮق در ‪ USBR20‬ﺑﺎزﺑﻴﻨﻲ ‪1976‬ﺗﻮﺻﻴﻪ ﺷﺪه اﺳﺖ‪ .‬و ﺟﻬﺖ ﻣﺤﺎﺳﺒﻪ ﺳﺮﻋﺖ ﻣﺨﺼﻮص از آن اﺳﺘﻔﺎده ﺷﺪه و ﺑﺮ ﻣﺒﻨﺎي‬

‫آن ﻣﻨﺤﻨﻲ ﻫﺎ و رواﺑﻂ ﻃﺮاﺣﻲ اراﺋﻪ ﻣﻲ ﮔﺮدد‪.‬‬

‫ﺳﺮﻋﺖ ﻣﺨﺼﻮص ﻳﻚ ﺗﻮرﺑﻴﻦ‪ ،‬ﻣﻌﺎدل ﺳﺮﻋﺘﻲ اﺳﺖ ﺑﺮﺣﺴﺐ دور در دﻗﻴﻘﻪ ﺑﺮاي ﺗﻮرﺑﻴﻦ‪ ،‬ﺑﻄﻮرﻳﻜﻪ اﮔﺮ اﻳﻦ ﺗﻮرﺑﻴﻦ‪ ،‬ﻣﺸﺎﺑﻬﺎً از ﻧﻈﺮ‬

‫اﺑﻌﺎدي ﻛﻮﭼﻚ ﺷﻮد‪ ،‬ﺗﻮان ﻳﻚ ﻛﻴﻠﻮوات را ﺗﻮﺳﻂ ﻳﻚ ﻣﺘﺮ ارﺗﻔﺎع در ﺣﺎﻟﺖ دﺑﻲ ﻛﺎﻣﻞ اﻳﺠﺎد ﻧﻤﺎﻳﺪ‪ .‬ﺳﺮﻋﺘﻬﺎي ﻣﺨﺼﻮص ﭘﺎﻳﻴﻦ ﺑﺎ‬

‫ارﺗﻔﺎﻋﻬﺎي ﺑﺎﻻ و ﺳﺮﻋﺘﻬﺎي ﻣﺨﺼﻮص ﺑﺎﻻ ﺑﺎ ارﺗﻔﺎﻋﻬﺎي ﭘﺎﻳﻴﻦ ﻣﻨﺎﺳﺐ ﻣﻲ ﺑﺎﺷﻨﺪ‪ .‬ﺑﻌﻼوه ﻣﺤﺪوده وﺳﻴﻌﻲ از ﺳﺮﻋﺘﻬﺎي ﻣﺨﺼﻮص‬

‫وﺟﻮد دارﻧﺪ ﻛﻪ ﺑﺮاي ﻳﻚ ارﺗﻔﺎع ﺗﻌﻴﻴﻦ ﺷﺪه ﻣﻨﺎﺳﺐ ﻣﻲﺑﺎﺷﻨﺪ‪.‬‬

‫اﻧﺘﺨﺎب ﺳﺮﻋﺖ ﻣﺨﺼﻮص ﺑﺎﻻ ﺑﺮاي ﻳﻚ ارﺗﻔﺎع ﻣﺸﺨﺺ‪ ،‬ﺗﻮرﺑﻴﻦ ژﻧﺮاﺗﻮر ﻛﻮﭼﻜﺘﺮ و ﺻﺮﻓﻪ ﺟﻮﻳﻲ در ﻫﺰﻳﻨﻪ ﻫﺎي اﻗﺘﺼﺎدي را‬

‫ﻧﺘﻴﺠﻪ ﺧﻮاﻫﺪ داد‪ .‬در ﻋﻴﻦ ﺣﺎل‪ ،‬در اﻳﻦ ﺻﻮرت ﺗﻮرﺑﻴﻦ ﺑﺎﻳﺴﺘﻲ در ﺗﺮاز ﭘﺎﻳﻴﻦ ﺗﺮي ﻗﺮار ﮔﻴﺮد ﻛﻪ ﺑﺎﻋﺚ ﻣﺼﺮف ﻫﺰﻳﻨﻪ ﻫﺎي ﺻﺮﻓﻪ‬

‫ﺟﻮﻳﻲ ﺷﺪه ﻣﻲ ﺷﻮد‪ .‬ﻫﻤﭽﻨﻴﻦ ﺑﺎزده ﭘﺎﻳﻴﻦ ﺗﺮي ﻗﺎﺑﻞ اﻧﺘﻈﺎر ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫‪٣٣‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫ﺷﻜﻞ )‪ (5‬ﻣﻨﺤﻨﻲ ﻫﺎي ﻣﺨﺘﻠﻒ ﺑﺮاي ﻣﺤﺎﺳﺒﻪ ‪ns‬‬

‫ﺳﺮﻋﺖ ﭼﺮﺧﺸﻲ ﻳﺎ ﺳﺮﻋﺖ ﻃﺮاﺣﻲ ‪ n‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻣﻼﺣﻈﺎت زﻳﺮ اﻧﺘﺨﺎب ﺧﻮاﻫﺪ ﺷﺪ‪:‬‬

‫اﻟﻒ – ﻣﻌﻤﻮﻻً ژﻧﺮاﺗﻮرﻫﺎﻳﻲ ﺑﺎ ﺗﻌﺪاد ﻗﻄﺒﻬﺎي ﻣﻀﺮب ﭼﻬﺎر ﺗﺮﺟﻴﺢ داده ﻣﻲ ﺷﻮد‪ ،‬وﻟﻲ ﺑﻌﻀﻲ از ژﻧﺮاﺗﻮرﻫﺎي اﺳﺘﺎﻧﺪارد ﺑﺎ ﺗﻌﺪاد‬

‫ﻗﻄﺒﻬﺎي ﻣﻀﺮب دو ﻧﻴﺰ ﻗﺎﺑﻞ دﺳﺘﺮﺳﻲ ﻣﻲ ﺑﺎﺷﻨﺪ‪.‬‬

‫ب‪ -‬اﮔﺮ ﺗﻐﻴﻴﺮات در ارﺗﻔﺎع‪ ،‬ﻛﻤﺘﺮ از ‪ %10‬ارﺗﻔﺎع ﻃﺮاﺣﻲ ﻣﻮرد اﻧﺘﻈﺎر ﺑﺎﺷﺪ‪ .‬ﻧﺰدﻳﻜﺘﺮﻳﻦ ﺳﺮﻋﺖ ﭼﺮﺧﺸﻲ ﺑﺰرﮔﺘﺮ اﻧﺘﺨﺎب ﺧﻮاﻫﺪ ﺷﺪ و‬

‫در ﺗﻐﻴﻴﺮات ارﺗﻔﺎع ﺑﻴﺸﺘﺮ از ‪ %10‬ارﺗﻔﺎع ﻃﺮاﺣﻲ‪ ،‬ﻧﺰدﻳﻜﺘﺮﻳﻦ ﺳﺮﻋﺖ ﭼﺮﺧﺶ ﻛﻮﭼﻜﺘﺮ ﭘﻴﺸﻨﻬﺎد ﻣﻲ ﺷﻮد‪.‬‬

‫در ﻧﻴﺮوﮔﺎه ﻗﻄﻌﻪ ﺳﻮم و ﭼﻬﺎرم ﺑﺎ اﺳﺘﻔﺎده از ﻣﺤﺎﺳﺒﺎت ﻛﻼﺳﻴﻚ ‪ ،‬ﺗﻮرﺑﻴﻦ در ﻫﺮ واﺣﺪ ﺑﺎ دو ﺟﺖ آب ﺑﻪ ﺗﺮﺗﻴﺐ ﺑﺎ دور ‪600 r pm‬‬
‫و ‪ 500 r pm‬اﻧﺘﺨﺎب ﻣﻲ ﮔﺮدد ‪.‬‬

‫‪٣۴‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -4-8‬ﻣﺸﺨﺼﺎت ﻣﻜﺎﻧﻴﻜﻲ ﻧﻴﺮوﮔﺎﻫﻬﺎي ﻗﻄﻌﺎت ﺳﻮم و ﭼﻬﺎرم‬

‫ﻫﻤﺎﻧﻄﻮري ﻛﻪ در ﺷﻜﻞ )‪ (4‬ﻣﻼﺣﻈﻪ ﻣﻲ ﮔﺮدد‪ ،‬ﺗﻮرﺑﻴﻨﻬﺎي اﻳﻦ ﭘﺮوژه از ﻧﻮع ﭘﻠﺘﻮن اﻓﻘﻲ )‪(Horizontal pelton‬‬

‫ﻣﻲ ﺑﺎﺷﻨﺪ‪ .‬ﺑﺎ در ﻧﻈﺮ ﮔﺮﻓﺘﻦ ﻣﻄﺎﻟﺒﻲ ﻛﻪ ﺑﻪ آﻧﻬﺎ اﺷﺎره ﺷﺪ و ﺑﺮ اﺳﺎس ﻃﺮاﺣﻲ اوﻟﻴﻪ ﻧﻴﺮوﮔﺎه ﻛﻪ ﺑﻪ ﻛﻤﻚ ﻣﺮاﺟﻊ ‪ ،‬اﺳﺘﺎﻧﺪاردﻫﺎي‬

‫ﻣﻌﺘﺒﺮ و ﻧﺮم اﻓﺰار اﻧﺠﺎم ﭘﺬﻳﺮﻓﺘﻪ اﺳﺖ‪ ،‬ﻣﺸﺨﺼﺎت ﻓﻨﻲ ﺗﻮرﺑﻴﻦ ﻧﻴﺮوﮔﺎﻫﻬﺎي ﺧﻂ اﻧﺘﻘﺎل در ﺟﺪول)‪ (28‬اراﺋﻪ ﮔﺮدﻳﺪه اﺳﺖ‪ .‬اﻳﻦ ﻧﺘﺎﻳﺞ‬

‫ﺑﺎ ﻓﺮض راﻧﺪﻣﺎن ﻧﺎﻣﻲ ‪ %89.4‬ﺑﺮاي ﺗﻮرﺑﻴﻦ ﺑﻪ دﺳﺖ آﻣﺪهاﺳﺖ‪.‬‬

‫ﺟﺪول)‪ - (28‬ﻣﺸﺨﺼﺎت ﻣﻜﺎﻧﻴﻜﻲ ﺗﻮرﺑﻴﻦ‬


‫ﻗﻄﻌﻪ ﭼﻬﺎرم‬ ‫ﻗﻄﻌﻪ ﺳﻮم‬ ‫ﻣﺸﺨﺼﺎت‬

‫‪2135‬‬ ‫‪2370‬‬ ‫رﻗﻮم ﻧﺮﻣﺎل‪m.a.s.l‬‬

‫ﭘﻠﺘﻮن ﺑﺎ ﻣﺤﻮر اﻓﻘﻲ‬ ‫ﭘﻠﺘﻮن ﺑﺎ ﻣﺤﻮر اﻓﻘﻲ‬ ‫ﻣﺪل‬

‫‪2‬‬ ‫‪2‬‬ ‫ﺗﻌﺪاد واﺣﺪ‬

‫‪148/15‬‬ ‫‪185.08‬‬ ‫ﻫﺪ ﻃﺮاﺣﻲ‬

‫‪1‬‬ ‫‪1‬‬ ‫دﺑﻲ ﻃﺮاﺣﻲ ﻫﺮ واﺣﺪ ‪s/3m‬‬

‫‪1419‬‬ ‫‪1606‬‬ ‫ﺗﻮان ﻃﺮاﺣﻲ ﺗﻮرﺑﻴﻦ در ﻫﺮ واﺣﺪ ‪KW‬‬

‫‪89.4‬‬ ‫‪89‬‬ ‫راﻧﺪﻣﺎن ﻧﺎﻣﻲ ﺗﻮرﺑﻴﻦ‬

‫‪500‬‬ ‫‪600‬‬ ‫دور ﺗﻮرﺑﻴﻦ ‪RPM‬‬

‫‪19.5‬‬ ‫‪21.2‬‬ ‫ﺳﺮﻋﺖ ﻣﺨﺼﻮص ﺗﻮرﺑﻴﻦ در ﺗﻮان ﻧﺎﻣﻲ ﺑﻪ ازاي ﻫﺮ ﺟﺖ ‪m-kw‬‬

‫‪27.5‬‬ ‫‪29.9‬‬ ‫ﺳﺮﻋﺖ ﻣﺨﺼﻮص ﻛﻠﻲ ﺗﻮرﺑﻴﻦ در ﺗﻮان ﻧﺎﻣﻲ ‪m-kw‬‬

‫‪12‬‬ ‫‪10‬‬ ‫ﺗﻌﺪاد ﻗﻄﺒﻬﺎي ژﻧﺮاﺗﻮر‬

‫‪1915‬‬ ‫‪2135‬‬ ‫ﺗﺮاز ﻣﺤﻮر ﺗﻮرﺑﻴﻨﻬﺎ‪m.a.s.l‬‬

‫‪870‬‬ ‫‪1044‬‬ ‫ﺣﺪاﻛﺜﺮ ﺳﺮﻋﺖ ﻓﺮار ‪RPM‬‬

‫‪1.028‬‬ ‫‪909‬‬ ‫ﻗﻄﺮ ﮔﺎم راﻧﺮ‬

‫‪1196‬‬ ‫‪871‬‬ ‫وزن ﺗﻘﺮﻳﺒﻲ راﻧﺮ ‪Kg‬‬

‫‪62‬‬ ‫‪62‬‬ ‫ﺿﺮﻳﺐ ﻛﺎرﻛﺮد ﺣﺪاﻗﻞ ﺗﻮرﺑﻴﻦ ﺑﺮاي دو ﺟﺖ )ﻧﺴﺒﺖ دﺑﻲ ﺣﺪاﻗﻞ ﺑﻪ دﺑﻲ راﻧﺪﻣﺎن ﺑﻬﻴﻨﻪ( ‪%‬‬

‫‪16‬‬ ‫‪16‬‬ ‫ﺿﺮﻳﺐ ﻛﺎرﻛﺮد ﺣﺪاﻗﻞ ﺗﻮرﺑﻴﻦ ﺑﺮاي ﻳﻚ ﺟﺖ )ﻧﺴﺒﺖ دﺑﻲ ﺣﺪاﻗﻞ ﺑﻪ دﺑﻲ راﻧﺪﻣﺎن ﺑﻬﻴﻨﻪ( ‪%‬‬

‫‪140‬‬ ‫‪140‬‬ ‫ﺿﺮﻳﺐ ﻛﺎرﻛﺮد ﺣﺪاﻛﺜﺮ ﺗﻮرﺑﻴﻦ ﺑﺮاي دو ﺟﺖ )ﻧﺴﺒﺖ دﺑﻲ ﺣﺪاﻛﺜﺮ ﺑﻪ دﺑﻲ راﻧﺪﻣﺎن ﺑﻬﻴﻨﻪ( ‪%‬‬

‫‪121‬‬ ‫‪121‬‬ ‫ﺿﺮﻳﺐ ﻛﺎرﻛﺮد ﺣﺪاﻛﺜﺮ ﺗﻮرﺑﻴﻦ ﺑﺮاي ﻳﻚ ﺟﺖ )ﻧﺴﺒﺖ دﺑﻲ ﺣﺪاﻛﺜﺮ ﺑﻪ دﺑﻲ راﻧﺪﻣﺎن ﺑﻬﻴﻨﻪ( ‪%‬‬

‫‪1117‬‬ ‫‪1117‬‬ ‫ﻗﻄﺮ ﭘﻨﺴﺘﺎك‪mm‬‬

‫‪23773‬‬ ‫‪16525‬‬ ‫ﻃﻮل ﭘﻨﺴﺘﺎك‪m‬‬

‫‪11‬‬ ‫‪11‬‬ ‫ﺿﺨﺎﻣﺖ ﭘﻨﺴﺘﺎك ‪mm‬‬

‫‪٣۵‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫در اﻳﻦ ﺟﺪول‪ ،‬ﻧﺘﺎﻳﺞ ﻛﻠﻲ ﻃﺮح اوﻟﻴﻪ ﻧﻴﺮوﮔﺎه اراﺋﻪ ﮔﺮدﻳﺪه اﺳﺖ‪ .‬ﻧﺘﺎﻳﺞ ﻛﺎﻣﻞﺗﺮ در ﻣﻮرد اﺑﻌﺎد و ﻣﺸﺨﺼﺎت اﺟﺰاي اﺻﻠﻲ ﺗﻮرﺑﻴﻦ در‬

‫ﭘﻴﻮﺳﺖ اﻟﻒ وب در ﻧﻘﺸﻪ ﺷﻤﺎﺗﻴﻚ ﻣﺮﺑﻮﻃﻪ آورده ﺷﺪه اﺳﺖ‪ .‬در اداﻣﻪ ‪ ،‬ﺑﺮاﺳﺎس دادهﻫﺎي ﺑﻪدﺳﺖ آﻣﺪه و ﺑﻪ اﺧﺘﺼﺎر‪ ،‬ﻣﺸﺨﺼﺎت‬

‫ﻣﻮرد ﻧﻴﺎز ﺗﻮرﺑﻴﻦ و دﻳﮕﺮ ﺗﺠﻬﻴﺰات ﻣﻜﺎﻧﻴﻜﻲ ﻧﻴﺮوﮔﺎه ﺗﺸﺮﻳﺢ ﺧﻮاﻫﺪ ﺷﺪ‪.‬‬

‫‪-9‬ﺗﺠﻬﻴﺰات اﺻﻠﻲ ﻣﻜﺎﻧﻴﻜﻲ‬

‫‪-1-9‬ﺗﺠﻬﻴﺰات ﺗﻮرﺑﻴﻦ‬

‫ﺗﻮرﺑﻴﻦ ﭘﻠﺘﻮن)‪ (pelton‬از اﺟﺰاء ﻣﺨﺘﻠﻔﻲ ﺗﺸﻜﻴﻞ ﺷﺪه اﺳﺖ ﻛﻪ ﻫﺮﻳﻚ وﻇﻴﻔﻪ ﺧﺎﺻﻲ را ﺑﺮﻋﻬﺪه دارﻧﺪ‪ .‬در اﻳﻦ ﻗﺴﻤﺖ ﺑﻪ‬

‫ﻣﻌﺮﻓﻲ ﻣﻬﻤﺘﺮﻳﻦ اﺟﺰاء ﺗﻮرﺑﻴﻦ ﭘﺮداﺧﺘﻪ ﺧﻮاﻫﺪ ﺷﺪ‪.‬‬

‫‪ -1-1-9‬ﻣﺤﻔﻈﻪ ﺗﻮرﺑﻴﻦ )‪:(Turbine Housing‬‬

‫ﻳﻜﻲ از اﻳﻦ اﺟﺰاء ﻣﺤﻔﻈﻪ ﺗﻮرﺑﻴﻦ)‪ (Turbine Housing‬ﻣﻲﺑﺎﺷﺪ ﻛﻪ وﻇﻴﻔﻪ ﺟﻤﻊآوري آب ﺧﺮوﺟﻲ از راﻧﺮ را ﺑﺮﻋﻬﺪه دارد‪.‬‬

‫ﺷﻜﻞ و اﻧﺪازه ﻣﺤﻔﻈﻪ ﺗﻮرﺑﻴﻦ)‪ (Turbine Housing‬ﺑﺎﻳﺴﺘﻲ ﺑﺎ ﻃﺮح ﻛﻠﻲ ﻧﻴﺮوﮔﺎه آﺑﻲ ﻫﻤﺨﻮاﻧﻲ داﺷﺘﻪ ﺑﺎﺷﺪ‪ .‬ﺟﻨﺲ ﻣﺤﻔﻈﻪ‬

‫ﺗﻮرﺑﻴﻦ از ورقﻫﺎي ﻓﻮﻻدي اﻧﺘﺨﺎب ﺷﺪه و ﺑﻪ ﮔﻮﻧﻪاي ﺑﺎﺷﺪ ﻛﻪ ﺗﻮاﻧﺎﺋﻲ ﺗﺤﻤﻞ ﺗﻨﺶﻫﺎي ﻧﺎﺷﻲ از ﺑﻴﺸﺘﺮﻳﻦ ﻓﺸﺎر اﺳﺘﺎﺗﻴﻜﻲ و‬

‫دﻳﻨﺎﻣﻴﻜﻲ را داﺷﺘﻪ ﺑﺎﺷﺪ وﭼﻨﺪ ﺗﻜﻪ ﺳﺎﺧﺘﻪ و ﻃﺮاﺣﻲ ﮔﺮدد ﺗﺎ ﻧﺼﺐ و ﺗﻌﻤﻴﺮات آن آﺳﺎن ﺑﺎﺷﺪ‪.‬‬

‫‪ -2-2-9‬راﻧﺮ )‪:(RUNNER‬‬

‫از دﻳﮕﺮ اﺟﺰاء ﻣﻬﻢ ﺗﻮرﺑﻴﻦ‪ ،‬راﻧﺮ )‪ (Runner‬ﻣﻲﺑﺎﺷﺪ ﻛﻪ وﻇﻴﻔﻪ ﺗﺒﺪﻳﻞ اﻧﺮژي ﻫﻴﺪروﻟﻴﻜﻲ آب ﺑﻪ اﻧﺮژي ﻣﻜﺎﻧﻴﻜﻲ را ﺑﺮ ﻋﻬﺪه‬

‫دارد‪ .‬از اﻳﻦ رو ﺑﻪ دﻟﻴﻞ ﻛﺎرﻛﺮد راﻧﺮ ‪ ،‬ﻃﺮاﺣﻲ و اﻧﺘﺨﺎب ﺟﻨﺲ آن از اﻫﻤﻴﺖ ﺑﺎﻻﺋﻲ ﺑﺮﺧﻮردار ﻣﻲﺑﺎﺷﺪ‪ .‬ﺑﺎ ﺑﺮرﺳﻲﻫﺎي ﺑﻪﻋﻤﻞ آﻣﺪه‬

‫ﺑﺮروي ﻧﻴﺮوﮔﺎﻫﻬﺎي آﺑﻲ ﺳﺎﺧﺘﻪ ﺷﺪه و ﻳﺎ در ﺣﺎل ﺳﺎﺧﺖ ﻣﺸﺎﻫﺪه ﻣﻲﮔﺮددﻛﻪ ﻓﻮﻻد زﻧﮓ ﻧﺰن )‪(Stainless Steel‬‬

‫ﻣﻨﺎﺳﺐﺗﺮﻳﻦ و ﭘﺮﻛﺎر ﺑﺮدﺗﺮﻳﻦ ﻣﺎده ﺟﻬﺖ ﺳﺎﺧﺖ راﻧﺮ و ﺟﺎم ﻫﺎ )‪ (Bucket‬ﻣﻲﺑﺎﺷﺪ‪ .‬ﻫﻤﭽﻨﻴﻦ ﺑﻪدﻟﻴﻞ ﻛﺎرﻛﺮد وﻳﮋه راﻧﺮ و ﺗﺄﺛﻴﺮ‬

‫ﻋﻮاﻣﻞ ﮔﻮﻧﺎﮔﻮن ﺑﺮ روي ﺟﺎم ﻫﺎي )‪ (Bucket‬آن ﻫﻤﺎﻧﻨﺪ ﭘﺪﻳﺪه ﺧﻮردﮔﻲ‪ ،‬ﺳﺎﻳﺶ و ﻧﻴﺰ ﺑﺎ درﻧﻈﺮ ﮔﺮﻓﺘﻦ ﻋﻮاﻣﻞ ﻣﺆﺛﺮ در ﺳﺎﺧﺖ‪،‬‬

‫ﺟﻨﺲ دﻗﻴﻖ ﻓﻮﻻد زﻧﮓ ﻧﺰن ﻗﺎﺑﻞ ﺗﻌﻴﻴﻦ ﺧﻮاﻫﺪ ﺑﻮد‪ .‬در ﭘﻴﻮﺳﺖ ﻫﺎي اﻟﻒ و ب اﻃﻼﻋﺎﺗﻲ از راﻧﺮ اﻧﺘﺨﺎﺑﻲ آورده ﺷﺪه اﺳﺖ‪.‬راﻧﺮﻫﺎ ﺑﻪ‬

‫‪٣۶‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫ﺻﻮرت رﻳﺨﺘﻪ ﮔﺮي و ﺟﻮﺷﻜﺎري ﻣﻲ ﺑﺎﺷﻨﺪ‪ .‬و اﺗﺼﺎل راﻧﺮ ﺑﻪ ﻣﺤﻮر ﺗﻮرﺑﻴﻦ ﺗﻮﺳﻂ ﭘﻴﭻ ﻫﺎﻳﻲ اﻣﻜﺎن ﭘﺬﻳﺮ ﻣﻴﮕﺮدد‪ .‬ﺟﺎم ﻫﺎي راﻧﺮ‬

‫ﺑﺎﻳﺪ ﻣﺎﺷﻴﻦ ﻛﺎري و ﭘﺮداﺧﺖ ﺷﻮﻧﺪ ﺗﺎ ﺳﻄﺤﻲ ﺻﺎف داﺷﺘﻪ ﺑﺎﺷﻨﺪ‪ .‬در ﻃﻲ ﻋﻤﻠﻴﺎت ﺳﺎﺧﺖ‪،‬ﺷﺎﺑﻠﻮن ﺟﺎم ﻫﺎ ﺑﺎﻳﺪ در دﺳﺘﺮس ﺑﺎﺷﺪ ﺗﺎ‬

‫ﻛﻨﺘﺮل ﺷﻜﻞ و ﭘﺮوﻓﻴﻞ ﺟﺎم ﻫﺎ اﻣﻜﺎن ﭘﺬﻳﺮ ﺑﺎﺷﺪ‪.‬ﻣﺠﻤﻮﻋﻪ راﻧﺮ ﺑﺎﻳﺪ از ﻧﻈﺮ اﺳﺘﺎﺗﻴﻜﻲ ﺑﺎﻻﻧﺲ ﺑﺎﺷﺪ و در ﺻﻮرت ﻗﺎﺑﻞ اﺟﺮا ﺑﻮدن‪،‬‬

‫ﺷﺎﻓﺖ راﻧﺮ در ﻛﺎرﺧﺎﻧﻪ ﺳﺎزﻧﺪه ﺑﺮ روي راﻧﺮ ﻣﻮﻧﺘﺎژ ﺷﻮد‪ .‬ﺑﺎﻻﻧﺲ اﺳﺘﺎﺗﻴﻜﻲ ﻣﺠﻤﻮﻋﻪ ﺷﺎﻓﺖ و راﻧﺮ از رده ‪ G6.3‬و ﻣﻄﺎﺑﻖ اﺳﺘﺎﻧﺪارد‬

‫‪ Iso 1940‬ﺑﺎﻳﺪ اﻧﺠﺎم ﺷﻮد‪.‬‬

‫‪ -3-2-9‬ﭘﺎﺷﻨﺪه )‪:(Injector‬‬

‫ﺑﺮاي ﻫﺮ ﺗﻮرﺑﻴﻦ ﺑﺎﻳﺪ ﺳﻪ اﻗﺸﺎﻧﻚ ﺗﻬﻴﻪ ﺷﻮد‪.‬ﭘﺎﺷﻨﺪه ﻫﺎ ﺑﺎﻳﺪ ﻃﻮري ﻃﺮاﺣﻲ ﺷﻮﻧﺪ ﻛﻪ ﺗﺎ ﺣﺪ اﻣﻜﺎن ﺟﺖ آب ﻳﻜﻨﻮاﺧﺘﻲ را ﺗﻮﻟﻴﺪ‬

‫ﻧﻤﺎﻳﻨﺪ‪.‬ﭘﺎﺷﻨﺪه ﻫﺎ ﺑﺎﻳﺪ ﻣﺠﻬﺰ ﺑﻪ ﻧﺎزل ﻫﺎﻳﻲ ﺑﺎﺷﻨﺪ ﻛﻪ ﺳﺮوﻣﻮﺗﻮرﻫﺎي ﻫﻴﺪروﻟﻴﻜﻲ آن دو ﺟﻬﺘﻪ ﺑﺎﺷﺪ‪ .‬ﭘﺎﺷﻨﺪه ﻫﺎ ﺑﺎﻳﺪ ﻃﻮري ﻃﺮاﺣﻲ‬

‫ﺷﻮﻧﺪ ﻛﻪ ﻗﺎﺑﻞ ﺗﻌﻮﻳﺾ ﺑﺎﺷﻨﺪ‪.‬ﭘﺎﺷﻨﺪه ﻫﺎ ﺑﺎﻳﺪ ﻣﺠﻬﺰ ﺑﻪ ﻳﻚ ﻣﻮﻗﻌﻴﺖ ﺳﻨﺞ ﺑﺮاي ﻧﻤﺎﻳﺶ ﻣﻮﻗﻌﻴﺖ ﻧﺎزل ﻫﺎ ﺑﺎﺷﺪ‪ .‬ﻧﻮك ﻧﺎزل ﻫﺎ و ﺣﻠﻘﻪ‬

‫ﻧﺸﻴﻤﻨﮕﺎه ﻧﺎزل ﻫﺎ از ﺟﻨﺲ ﻓﻮﻻد زﻧﮓ ﻧﺰن ﺑﺎ ‪ %13‬ﻛﺮوم و ‪ %4‬ﻧﻴﻜﻞ ﺑﺎﺷﺪ‪.‬‬

‫‪ -4-2-9‬اﻧﺤﺮاف دﻫﻨﺪه )‪:(Deflector‬‬

‫اﻧﺤﺮاف دﻫﻨﺪه ﺑﺎﻳﺪ از ﺟﻨﺲ ﻓﻮﻻد زﻧﮓ ﻧﺰن ﺑﺎ ‪ %13‬ﻛﺮوم و ‪ %4‬ﻧﻴﻜﻞ ﺑﺎﺷﺪ‪.‬ﻳﻚ ﺳﺮوﻣﻮﺗﻮر ﻛﻪ ﺑﺎ روﻏﻦ ﮔﺎورﻧﺮ ﻛﺎر ﻣﻲ ﻛﻨﺪ ﺑﺎﻳﺪ‬

‫اﻧﺤﺮاف دﻫﻨﺪه ﻫﺎ را ﻛﻨﺘﺮل ﻧﻤﺎﻳﺪ‪.‬ﻳﻚ ﻣﻜﺎﻧﻴﺴﻢ ﻛﻨﺘﺮﻟﻲ ﺑﺮاي ﻗﺮارﮔﻴﺮي ﺻﺤﻴﺢ اﻧﺤﺮاف دﻫﻨﺪه در ﻣﻮﻗﻌﻴﺘﺶ و ﺣﺮﻛﺖ ﻧﺎزل ﺑﺎﻳﺪ‬

‫ﺗﻬﻴﻪ ﺷﻮد ﺗﺎ در ﻣﻮﻗﻊ ﺗﻐﻴﻴﺮ ﺑﺎر ﻋﻜﺲ اﻟﻌﻤﻞ ﻣﻨﺎﺳﺐ را ﺑﺮوز دﻫﺪ‪.‬در ﻃﻲ ﺑﻬﺮه ﺑﺮداري ﻋﺎدي‪،‬ﻧﺎزل ﻫﺎ ﺟﺮﻳﺎن آب را ﻛﻨﺘﺮل ﻧﻤﺎﻳﺪ ﺗﺎ‬

‫آب ﻛﺎﻓﻲ ﺑﻪ راﻧﺮ ﺑﺮﺧﻮرد ﻛﻨﺪ‪.‬اﻧﺤﺮاف دﻫﻨﺪه ﻫﺎ ﺗﻨﻬﺎ زﻣﺎﻧﻲ وارد ﺟﺖ آب ﻣﻲ ﺷﻮﻧﺪ ﻛﻪ ﻧﺮخ ﻛﺎﻫﺶ ﺑﺎر ﺑﻴﺸﺘﺮ از ﻣﻘﺪاري اﺳﺖ ﻛﻪ‬

‫ﺑﺘﻮان ﺑﺎر را ﺑﺎ ﻧﺎزل ﻫﺎ ﻛﻨﺘﺮل ﻛﺮد‪.‬اﻧﺤﺮاف دﻫﻨﺪه ﻫﺎ ﺑﺎﻳﺪ ﻃﻮري ﻃﺮاﺣﻲ ﺷﻮﻧﺪ ﻛﻪ در ﺻﻮرت وﻗﻮع ﻫﺮ ﻧﻮع اﻳﺮادي در ﻓﺸﺎر روﻏﻦ‬

‫ﮔﺎورﻧﺮ‪،‬ﺑﺘﻮاﻧﺪ ﻋﻜﺲ اﻟﻌﻤﻞ ﻣﻨﺎﺳﺐ ﻧﺸﺎن داده و ﺟﺖ آب را ﻛﺎﻣﻼ ﻣﻨﺤﺮف ﻧﻤﺎﻳﺪ‪ .‬اﻧﺤﺮاف دﻫﻨﺪه ﻫﺎ ﺑﺎﻳﺪ ﻗﺎدر ﺑﺎﺷﻨﺪ ﺑﻪ ﺳﺮﻋﺖ ﺟﺖ‬

‫آب را اﻧﺤﺮاف دﻫﻨﺪ ﺗﺎ در ﻃﻲ ﻓﺮآﻳﻨﺪ رد ﺑﺎر )‪ ( Load rejection‬اﻓﺰاﻳﺶ ﺳﺮﻋﺖ در ﻣﺤﺪوده ﻣﺠﺎز ﺑﺎﺷﺪ‪.‬اﻧﺤﺮاف دﻫﻨﺪه ﻫﺎ‬

‫ﺑﺎﻳﺪ ﻃﻮري ﺳﺎﺧﺘﻪ ﺷﻮد ﺗﺎ ﺑﻪ ﺻﻮرت ﻣﻄﻤﺌﻨﻲ در ﺑﺮاﺑﺮ ﺣﺪاﻛﺜﺮ ﺗﺨﻠﻴﻪ ﻣﺪاوم ﻫﺮ ﻧﺎزل ﻣﻘﺎوﻣﺖ ﻧﻤﺎﻳﺪ‪.‬‬

‫‪٣٧‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -5-2-9‬ﺟﻤﻊ ﻛﻨﻨﺪه )‪:(Collector‬‬

‫ﺟﻤﻊ ﻛﻨﻨﺪه ﭼﻨﺪ ﺷﺎﺧﻪ ﺑﻮده و ﺷﺎﻣﻞ ﻟﻮﻟﻪ ﻫﺎي ﺗﻮزﻳﻊ اﺳﺖ ﻛﻪ ﭘﺎﺷﻨﺪه ﻫﺎ را ﺑﻪ ﻗﻄﻌﻪ ﻗﺎﺑﻞ دﻣﻮﻧﺘﺎژ ﺷﻴﺮ ﻛﺮوي و ﺷﻴﺮ ﻛﺮوي)ﺷﻴﺮ‬

‫اﺻﻠﻲ ورودي(ﻣﺘﺼﻞ ﻣﻲ ﻛﻨﺪ‪.‬ﻃﺮاﺣﻲ ﺟﻤﻊ ﻛﻨﻨﺪه ﺑﺎﻳﺪ ﺑﻪ ﮔﻮﻧﻪ اي ﺑﺎﺷﺪ ﻛﻪ ﺗﻠﻔﺎت ﻫﻴﺪروﻟﻴﻜﻲ را ﺑﻪ ﺣﺪاﻗﻞ ﺑﺮﺳﺎﻧﺪ‪.‬‬

‫‪ -6-2-9‬ﻳﺎﺗﺎﻗﺎن ﺗﻮرﺑﻴﻦ)‪:(Turbine Guide Bearing‬‬

‫ﻳﺎﺗﺎﻗﺎن ﻫﺎدي ﺗﻮرﺑﻴﻦ ﺟﻬﺖ ﺳﺎﭘﻮرت ﻣﺤﻮر اﺻﻠﻲ ﺗﻮرﺑﻴﻦ ﺣﻴﻦ ﭼﺮﺧﺶ و ﺗﺤﻤﻞ ﻧﻴﺮوﻫﺎي ﺷﻌﺎﻋﻲ ﺑﻜﺎر ﻣﻲ رود‪.‬ﻳﺎﺗﺎﻗﺎن ﻫﺎدي‬

‫ﺑﺼﻮرت ﻗﻄﺎﻋﻲ ﺑﻮده و ﻗﻄﺎﻋﻬﺎ ﺗﻮﺳﻂ ﺑﺎﺑﻴﺖ ﭘﻮﺷﻴﺪه ﻣﻲ ﺷﻮﻧﺪ‪.‬ﺟﻨﺲ ﭘﻮﺳﺘﻪ ﻳﺎﺗﺎﻗﺎن از ﭼﺪن ﻳﺎ ﻓﻮﻻد ﻣﻲ ﺑﺎﺷﺪ‪.‬ﻳﺎﺗﺎﻗﺎن ﻫﺎي ﻫﺎدي‬

‫ﻋﻤﻮﻣﺎ ﭼﻨﺪ ﺗﻜﻪ ﻣﻲ ﺑﺎﺷﻨﺪ ﺗﺎ اﻣﻜﺎن ﻣﻮﻧﺘﺎژ و دﻣﻮﻧﺘﺎژ راﺣﺖ ﺳﻴﺴﺘﻢ ﻓﺮاﻫﻢ ﺷﻮد‪ .‬ﺑﻪ ﻣﻨﻈﻮر ﺧﻨﻚ ﻛﺎري روﻏﻦ از ﻛﻮﻟﺮﻫﺎي آب و‬

‫روﻏﻦ اﺳﺘﻔﺎده ﻣﻲ ﺷﻮد‪.‬ﺳﻴﺴﺘﻢ ﭼﺮﺧﺶ روﻏﻦ در ﻳﺎﺗﺎﻗﺎن ﺗﻮرﺑﻴﻦ ﺑﻪ ﺻﻮرت اﺟﺒﺎري اﺳﺖ‪.‬‬

‫‪ -7-2-9‬ﻣﺤﻮر )‪:(Turbine Shaft‬‬

‫ﻣﺤﻮر ﺗﻮرﺑﻴﻦ ﺑﻪ ﺻﻮرت رﻳﺨﺘﮕﻲ ﻳﻜﭙﺎرﭼﻪ و ﺑﻪ ﺻﻮرت ﻓﻮرج ﺷﺪه ﻣﻲ ﺑﺎﺷﺪ و از ﻓﻮﻻد ﻛﻢ آﻟﻴﺎژ ﺳﺎﺧﺘﻪ ﻣﻲ ﺷﻮد‪ .‬ﻃﺮاﺣﻲ آن ﺑﺎﻳﺪ‬

‫ﺑﻪ ﺻﻮرﺗﻲ ﺑﺎﺷﺪ ﺗﺎ در ﺑﺮاﺑﺮ ﺑﻴﺸﺘﺮﻳﻦ ﻛﻮﭘﻞ ﭘﻴﭽﺸﻲ در ﺑﺎر ﻣﺎﻛﺰﻳﻤﻢ و ﻧﻴﺰ در ﺳﺮﻋﺖ ﻓﺮار‪،‬ﻣﻘﺎوﻣﺖ داﺷﺘﻪ ﺑﺎﺷﺪ‪.‬ﻣﺤﻮر ﺗﻮرﺑﻴﻦ ﺗﻮﺳﻂ‬

‫ﻳﻚ ﻛﻮﭘﻠﻴﻨﮓ ﭘﻴﭻ و ﻣﻬﺮه اي ﻣﺴﺘﻘﻴﻤﺎ ﺑﻪ ﻣﺤﻮر ژﻧﺮاﺗﻮر ﻣﺘﺼﻞ ﻣﻲ ﺷﻮد‪.‬‬

‫‪ -8-2-9‬آب ﺑﻨﺪ ﻣﺤﻮر ﺗﻮرﺑﻴﻦ )‪:(Turbine Shaft Seal‬‬

‫آب ﺑﻨﺪ از ﻧﺸﺖ آب ﻋﺒﻮري ﺗﻮرﺑﻴﻦ از ﻛﻨﺎر ﻣﺤﻮر )ﺷﺎﻓﺖ ( ﺟﻠﻮﮔﻴﺮي ﻣﻲ ﻛﻨﺪ‪.‬آب ﺑﻨﺪ از ﻧﻮع ﺷﻌﺎﻋﻲ ﻳﺎ ﻣﺤﻮري ﺑﺮ روي ﻳﻚ‬

‫ﭘﻮﺳﺘﻪ ﻓﻮﻻد زﻧﮓ ﻧﺰن ﺑﺎﻳﺪ ﺗﻬﻴﻪ ﺷﻮد‪.‬ﺿﻤﻨﺎ ﻳﻚ ﺳﻴﺴﺘﻢ ﺗﺨﻠﻴﻪ آب ﺑﺮاي ﺑﺮﮔﺸﺖ آﺑﻬﺎي ﻧﺸﺘﻲ ﺑﻪ ﭘﻴﺖ ﻧﻴﺰ ﺑﺎﻳﺪ ﺗﻬﻴﻪ ﺷﻮد‪.‬‬

‫ﻫﻤﭽﻨﻴﻦ ﺑﺮاﺳﺎس ﻧﻴﺮوﻫﺎي اﺳﺘﺎﺗﻴﻜﻲ و دﻳﻨﺎﻣﻴﻜﻲ ﺑﻪ وﺟﻮد آﻣﺪه در ﺗﺠﻬﻴﺰات ﻣﻜﺎﻧﻴﻜﻲ ﺗﻮرﺑﻴﻦ و ﻧﺤﻮه اﻧﺘﻘﺎل آﻧﻬﺎ ﺑﻪ ﻓﻮﻧﺪاﺳﻴﻮن‬

‫ﻧﻴﺮوﮔﺎه‪ ،‬ﺑﺮرﺳﻲ ﻣﺴﺎﺋﻞ ﺧﺴﺘﮕﻲ و ﻣﻜﺎﻧﻴﻚ ﺷﻜﺴﺖ در ﻃﺮاﺣﻲ اﺟﺰاء ﻗﺴﻤﺖﻫﺎي ﻣﻬﻢ ﺗﻮرﺑﻴﻦ‪ ،‬ﺑﺮرﺳﻲ ﭘﺪﻳﺪهﻫﺎي ارﺗﻌﺎﺷﺎت و…‬

‫از ﻣﻮاردي ﻫﺴﺘﻨﺪ ﻛﻪ ﺑﺎﻳﺴﺘﻲ ﺗﻮﺟﻪ وﻳﮋه ﺑﻪ آﻧﻬﺎ داﺷﺖ ﻛﻪ ﺗﺎ در ﻣﺮاﺣﻞ ﺑﻌﺪي ﻛﺎر‪ ،‬ﺑﻪ ﻃﻮر ﺟﺰﺋﻲﺗﺮ ﺑﻪ اﻳﻦ ﻣﻮارد ﭘﺮداﺧﺘﻪ ﺷﻮد‪.‬‬

‫‪٣٨‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -9-2-9‬ﮔﺎورﻧﺮ)‪(Governor‬‬
‫ﻳﻜﻲ از ﻣﻬﻤﺘﺮﻳﻦ اﺟﺰاء اﺻﻠﻲ ﻧﻴﺮوﮔﺎﻫﻬﺎي آﺑﻲ‪ ،‬ﮔﺎورﻧﺮ)‪ (Governor‬ﻣﻲﺑﺎﺷﺪ‪.‬وﻇﻴﻔﻪ ﮔﺎورﻧﺮ‪،‬ﺗﻨﻈﻴﻢ درﻳﭽﻪ ﻫﺎي ﺗﻮرﺑﻴﻦ ﺑﻪ‬

‫ﻣﻨﻈﻮر ﻛﻨﺘﺮل ﺳﺮﻋﺖ در ﺣﺎﻟﺖ ﺑﻲ ﺑﺎري )ﺑﺎ ﻫﺪف ﺳﻨﻜﺮون ﺷﺪن واﺣﺪ ﺑﺎ ﺷﺒﻜﻪ( و ﻛﻨﺘﺮل ﺗﻮان)در وﺿﻌﻴﺖ اﺗﺼﺎل ﺑﻪ ﺷﺒﻜﻪ( ﻣﻲ‬

‫ﺑﺎﺷﺪ‪.‬ﻫﻤﭽﻨﻴﻦ ﮔﺎورﻧﺮ وﻇﻴﻔﻪ ﺑﺴﺘﻦ ﺳﺮﻳﻊ درﻳﭽﻪ ﻫﺎ در زﻣﺎن ﻗﻄﻊ ﺑﺎر‪،‬ﺑﻪ ﻣﻨﻈﻮر ﺟﻠﻮﮔﻴﺮي از ﭼﺮﺧﺶ ﺗﻮرﺑﻴﻦ ﺗﺎ دور ﻓﺮار را ﺑﻌﻬﺪه‬

‫دارد‪.‬ﻛﻨﺘﺮﻟﺮ از ﻧﻮع ‪ PID‬ﺑﻮده ﺗﺎ ﻗﺎﺑﻠﻴﺖ ﭘﺎﺳﺦ ﺳﺮﻳﻊ ﺑﻪ ﺗﻐﻴﻴﺮات ﺑﺎر ‪ ،‬ﺳﺮﻋﺖ و ﭘﺎﻳﺪاري ﻻزم را داﺷﺘﻪ ﺑﺎﺷﺪ‪ .‬ﺳﺮﻋﺖ واﺣﺪ ﺗﻮﺳﻂ‬

‫ﺳﺮﻋﺖ ﺳﻨﺞ دﻳﺠﻴﺘﺎل اﻧﺪازه ﮔﻴﺮي ﻣﻲ ﺷﻮد‪.‬‬

‫ﮔﺎورﻧﺮ)‪ (Governor‬ﺑﺎﻳﺴﺘﻲ ﺑﺎ ﺳﻴﺴﺘﻢﻫﺎ و ﺗﺠﻬﻴﺰات ﻣﺨﺘﻠﻔﻲ ﻫﻤﺎﻧﻨﺪ ﺗﺠﻬﻴﺰات ﻛﻨﺘﺮﻟﻲ‪ ،‬ﭘﻤﭗﻫﺎي روﻏﻦ‪ ،‬ﺳﻴﺴﺘﻢ ﺗﺤﺮﻳﻚ‪،‬‬

‫ﺗﺮﻣﺰ ژﻧﺮاﺗﻮر و … ﻫﻤﺎﻫﻨﮓ ﺷﻮد‪ .‬ﻧﻮع ﮔﺎورﻧﺮ اﻧﺘﺨﺎﺑﻲ ﺑﺮاي ﻫﺮ واﺣﺪ ﻧﻴﺮوﮔﺎه ﺑﻪﺻﻮرت اﻟﻜﺘﺮو ﻫﻴﺪروﻟﻴﻜﻲ دﻳﺠﻴﺘﺎﻟﻲ ﭘﻴﺸﻨﻬﺎد ﻣﻲ‬

‫ﮔﺮدد‪ .‬ﻫﺮ واﺣﺪ ﻧﻴﺮوﮔﺎه ﺑﺎﻳﺪ ﺗﻮﺳﻂ ﻳﻚ ﮔﺎورﻧﺮ ﻣﺠﺰا ﻛﻨﺘﺮل و ﻫﺪاﻳﺖ ﺷﻮد‪ .‬ﺟﻬﺖ ﺗﺎﻣﻴﻦ ﻓﺸﺎر روﻏﻦ ﺳﺮوﻣﻮﺗﻮرﻫﺎ‪،‬ﻳﻚ ﺳﻴﺴﺘﻢ‬

‫ﻫﻴﺪروﻟﻴﻚ ﺑﺮاي ﻫﺮ واﺣﺪ ﺑﻪ ﺻﻮرت ﺟﺪاﮔﺎﻧﻪ ﺗﻬﻴﻪ ﻣﻲ ﺷﻮد ﻛﻪ ﺷﺎﻣﻞ ﻣﻮارد ذﻳﻞ ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫‪ -‬ﻳﻚ ﻣﺨﺰن روﻏﻦ ﺑﺪون ﻓﺸﺎر ﻓﻮﻻدي ﺑﺎ ﺻﻔﺤﺎت ﺟﻮﺷﻜﺎري ﺷﺪه ﻫﻤﺮاه ﺑﺎ ﻛﻠﻴﻪ اﺗﺼﺎﻻت و ﺗﺠﻬﻴﺰات ﻻزم‬

‫ﻣﺎﻧﻨﺪ‪:‬ﻓﻴﻠﺘﺮﻫﺎي روﻏﻦ‪،‬ﻧﻤﺎﻳﺸﮕﺮﻫﺎي ﺳﻄﺢ روﻏﻦ‪،‬ﻟﻮﻟﻪ وﻧﺖ‪،‬ﺗﺮﻣﻮﻣﺘﺮ و ﺳﻴﺴﺘﻢ ﮔﺮﻣﻜﻦ روﻏﻦ‬

‫‪ -‬دو ﻋﺪد اﻟﻜﺘﺮوﭘﻤﭗ ﻓﺸﺎر ﺑﺎﻻ ﺑﺎ ﺷﺎﻓﺖ ﻗﺎﻳﻢ‪،‬ﻛﻪ ﺑﺮ روي ﺗﺎﻧﻚ روﻏﻦ ﻧﺼﺐ ﻣﻲ ﺷﻮﻧﺪ‪.‬ﻫﺮ ﭘﻤﭗ ﺑﻪ ﺗﻨﻬﺎﻳﻲ ﻗﺎﺑﻠﻴﺖ ﺗﺎﻣﻴﻦ‬

‫‪ %100‬ﺣﺠﻢ روﻏﻦ ﻣﻮرد ﻧﻴﺎز را دارد‪.‬ﺗﺠﻬﻴﺰات ﻣﻮرد ﻧﻴﺎز ﻫﺮ ﭘﻤﭗ ﻧﻈﻴﺮ ﻛﻮﭘﻠﻴﻨﮓ ﻗﺎﺑﻞ اﻧﻌﻄﺎف‪،‬ﺷﻴﺮﻫﺎي اﻃﻤﻴﻨﺎن‬

‫‪،‬ﻳﻜﻄﺮﻓﻪ و ‪ ...‬ﺧﻮاﻫﻤﺪ ﺷﺪ‪.‬‬

‫‪ -‬ﺷﻴﺮﻫﺎي ﭼﻨﺪ راﻫﻪ و ﻟﻮﻟﻪ ﻫﺎي ﻓﻮﻻدي روﻏﻦ ﺑﺎ ﺗﺠﻬﻴﺰات و ﺳﺎﭘﻮرﺗﻬﺎي ﻻزم‬

‫‪ -‬ﻳﻚ ﻣﺨﺰن ﺗﺤﺖ ﻓﺸﺎر ﻧﻴﺘﺮوﻦ‪-‬روﻏﻦ‪،‬ﻫﻤﺮاه ﺑﺎ ﻧﻤﺎﻳﺸﮕﺮ ﺳﻄﺢ روﻏﻦ‪،‬ﻧﻤﺎﻳﺸﮕﺮ ﻓﺸﺎر‪،‬ﺷﻴﺮ اﻃﻤﻴﻨﺎن و ﺷﻴﺮ ﻫﻮاي ﻓﺸﺮده و‬

‫ﺳﺎﻳﺮ ﺗﺠﻬﻴﺰات ﻣﻮرد ﻧﻴﺎز ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫ﺑﻪ دﻟﻴﻞ اﺳﺘﻔﺎده از ﻛﭙﺴﻮل ﻫﺎي ﮔﺎز ﻧﻴﺘﺮوﻦ‪ ،‬ﺑﺠﺎي ﻫﻮاي ﻓﺸﺮده‪ ،‬ﺳﻴﺴﺘﻢ ﻫﻮاي ﻓﺸﺮده ﺑﺎ ﻓﺸﺎر ﺑﺎﻻ )ﻛﻤﭙﺮﺳﻮرﻫﺎي ﻓﺸﺎر ﺑﺎﻻ‪،‬‬

‫ﺗﺎﻧﻚ ﻫﻮا و ‪ ( ...‬از ﺗﺠﻬﻴﺰات ﻛﻤﻜﻲ ﻧﻴﺮوﮔﺎه ﺣﺬف ﺧﻮاﻫﺪ ﺷﺪ‪.‬‬

‫ﻣﺸﺨﺼﻪ ﻫﺎي ﺗﻨﻈﻴﻢ ﻳﻚ واﺣﺪ اﺳﺎﺳﺎً ﺗﺎﺑﻌﻲ از اﺛﺮ ﭼﺮخ ﻃﻴﺎر و اﻳﻨﺮﺳﻲ ﺳﺘﻮن آب ﻣﻴﺒﺎﺷﺪ‪ .‬ﭼﺮخ ﻃﻴﺎر ﻋﺎﻣﻞ ﭘﺎﻳﺪار ﻛﻨﻨﺪه ﺗﻨﻈﻴﻢ‬

‫ﺳﺮﻋﺖ اﺳﺖ در ﺣﺎﻟﻲ ﻛﻪ اﺛﺮ ﺳﺘﻮن آب ﺑﺎﻋﺚ ﻧﺎﭘﺎﻳﺪاري آن ﻣﻲ ﺷﻮد‪.‬‬

‫‪٣٩‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -10-2-9‬ﺷﻴﺮ ورودي ﺗﻮرﺑﻴﻦ )‪(Main inlet valve‬‬


‫ﺑﺮاي ﺣﻔﺎﻇﺖ از ﺗﻮرﺑﻴﻦ و اﺟﺰاي واﺑﺴﺘﻪ آن و ﺑﺮاي ﻗﻄﻊ ﺟﺮﻳﺎن آب ورودي ﺑﻪ ﺗﻮرﺑﻴﻦ در ﻣﻮاﻗﻊ ﺿﺮوري ﻛﻪ اﻧﺤﺮاف دﻫﻨﺪه ﻫﺎ و‬
‫ﻧﺎزل ﻫﺎ ﺑﻪ ﻫﺮ دﻟﻴﻞ ﻛﺎر ﻧﻨﻤﺎﻳﻨﺪ و ﻫﻤﭽﻨﻴﻦ ﺑﺮاي اﻧﺠﺎم ﺗﻌﻤﻴﺮات و ﺗﺨﻠﻴﻪ آب ﻣﺤﻔﻈﻪ ﺗﻮرﺑﻴﻦ‪ ،‬ﻧﻴﺎز ﺑﻪ ﻳﻚ ﺷﻴﺮ ﻗﻄﻊ و وﺻﻞ ﺟﺮﻳﺎن‬
‫ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻫﺪ ﻃﺮاﺣﻲ و ﻫﻤﭽﻨﻴﻦ ﺑﺮرﺳﻲ ﻃﺮحﻫﺎي اﺟﺮا ﺷﺪه ﭘﻴﺸﻴﻦ‪ ،‬ﺷﻴﺮ ﻛﺮوي )‪ (Spherical valve‬ﮔﺰﻳﻨﻪ‬
‫ﻣﻨﺎﺳﺒﻲ ﺑﺮاي اﻳﻦ ﻃﺮح ﻣﻲﺑﺎﺷﺪ‪ .‬ﻗﻄﺮ ﺷﻴﺮ ﻛﺮوي ﺣﺪود ‪ 500‬ﻣﻴﻠﻲ ﻣﺘﺮ ﻣﻲ ﺑﺎﺷﺪ‪.‬ﺑﺎز ﺷﺪن و ﺑﺴﺘﻪ ﺷﺪن ﺷﻴﺮ ﺗﻮﺳﻂ ﺳﺮوﻣﻮﺗﻮر دو‬
‫ﺟﻬﺘﻪ اﻧﺠﺎم ﺧﻮاﻫﺪ ﺷﺪ‪.‬ﺷﻴﺮ ﻛﺮوي ﻣﺠﻬﺰ ﺑﻪ ﻳﻚ ﺳﻴﺴﺘﻢ ﻛﻨﺎرﮔﺬر )‪ (By Pass‬ﻣﻲ ﺑﺎﺷﺪ ﻛﻪ وﻇﻴﻔﻪ آن ﻣﺘﻌﺎدل ﺳﺎزي ﻓﺸﺎر در‬
‫دو ﻃﺮف ﺷﻴﺮ ﻣﻲ ﺑﺎﺷﺪ ﺗﺎ ﺑﻌﺪ از ﻳﻜﺴﺎن ﺷﺪن ﻓﺸﺎر‪،‬ﺷﻴﺮ ﺑﺎز ﺷﻮد‪.‬اﻟﺒﺘﻪ ﺷﻴﺮ ﺑﺎﻳﺪ ﺑﺮاي ﺷﺮاﻳﻄﻲ ﻃﺮاﺣﻲ ﺷﻮد ﺗﺎ در زﻣﺎن ﺑﺮﻗﺮاري‬
‫ﺟﺮﻳﺎن ﻛﺎﻣﻞ از ﺗﻮرﺑﻴﻦ‪،‬ﻗﺎﺑﻠﻴﺖ ﺑﺴﺘﻪ ﺷﺪن را داﺷﺘﻪ ﺑﺎﺷﺪ‪ .‬ﺷﻴﺮ ﺑﺎي ﭘﺲ از ﻧﻮع ﺳﻮزﻧﻲ ﺑﻮده و ﻣﺤﺮك آن ﻫﻴﺪروﻟﻴﻜﻲ ﻣﻲ ﺑﺎﺷﺪ‪.‬‬
‫ﺑﺎﻻدﺳﺖ و ﭘﺎﻳﻴﻦ دﺳﺖ ﺷﻴﺮ ﺑﺎي ﭘﺲ ﺑﺎﻳﺪ ﻣﺠﻬﺰ ﺑﻪ ﺷﻴﺮﻫﺎي اﻳﺰوﻟﻪ ﻛﻨﻨﺪه ﺑﺎﺷﺪ‪.‬‬

‫ﺷﻴﺮ ﺑﺮاي ﻓﺸﺎر ﻃﺮاﺣﻲ ﻣﻌﺎدل ﻫﺪ ﻧﻴﺮوﮔﺎه ﺑﻌﻼوه ﻫﺪ ﻧﺎﺷﻲ از ﺿﺮﺑﻪ ﻗﻮچ )‪ (Water Hammer‬ﻃﺮاﺣﻲ ﻣﻲ ﺷﻮد و زﻣﺎن‬
‫ﺑﺴﺘﻪ ﺷﺪن آن ﺑﺮ اﺳﺎس ﻣﺤﺪود ﻛﺮدن ﻓﺸﺎر ﺗﺎ ﻓﺸﺎر ﻃﺮاﺣﻲ)ﻓﺸﺎر ﻣﺎﻛﺰﻳﻤﻢ‪+‬ﻓﺸﺎر ﻧﺎﺷﻲ از ﺿﺮﺑﻪ ﻗﻮچ( ﺗﻌﻴﻴﻦ ﻣﻲ ﮔﺮدد‪.‬‬

‫ﭘﺎراﻣﺘﺮﻫﺎي ﻛﻠﻴﺪي ﺷﻴﺮ ورودي ﻋﺒﺎرﺗﻨﺪ از‪:‬‬

‫‪Diameter =0.5m‬‬ ‫ﻗﻄﺮ ﺷﻴﺮ‬


‫‪Design Pressure =24bar‬‬ ‫ﻓﺸﺎر ﻃﺮاﺣﻲ ﻧﻴﺮوﮔﺎه ﻗﻄﻌﻪ ﺳﻮم‬
‫ﻓﺸﺎر ﻃﺮاﺣﻲ ﻧﻴﺮوﮔﺎه ﻗﻄﻌﻪ ﭼﻬﺎرم‬
‫‪Design Pressure=20‬‬
‫ﻓﺸﺎر ﺗﺴﺖ ﺷﻴﺮ ﻛﺮوي ﻧﻴﺮوﮔﺎه ﻗﻄﻌﻪ ﺳﻮم‬
‫‪Test Pressure =36 bar‬‬
‫‪Test Pressure =30 bar‬‬ ‫ﻓﺸﺎر ﺗﺴﺖ ﺷﻴﺮ ﻛﺮوي ﻧﻴﺮوﮔﺎه ﻗﻄﻌﻪ ﭼﻬﺎرم‬
‫‪Design Discharge = 1 m3/sec‬‬ ‫دﺑﻲ ﻃﺮاﺣﻲ‬
‫) ‪Closing time (from 0 to 120 sec.‬‬ ‫زﻣﺎن ﺑﺴﺘﻪ ﺷﺪن‬
‫‪adj ust abl e‬‬
‫‪Opening time (from 0 to 120 sec.‬‬ ‫زﻣﺎن ﺑﺎز ﺷﺪن‬
‫)‪adjustable‬‬
‫‪Bypass valve diameter = 60 mm‬‬ ‫ﻗﻄﺮ ﺷﻴﺮ ﺑﺎي ﭘﺎس‬
‫‪Bypass valve type = needle valve‬‬ ‫ﻧﻮع ﺷﻴﺮ ﺑﺎي ﭘﺎس‬

‫‪ -10‬ﺗﺠﻬﻴﺰات ﻛﻤﻜﻲ ﻣﻜﺎﻧﻴﻜﻲ ﻧﻴﺮوﮔﺎه‬


‫ﻋﻼوه ﺑﺮ ﺗﺠﻬﻴﺰات اﺻﻠﻲ ﻧﻴﺮوﮔﺎه ﻫﻤﺎﻧﻨﺪ‪ :‬ﺗﻮرﺑﻴﻦ‪ ،‬ﮔﺎورﻧﺮ و…‪ ،‬ﺳﻴﺴﺘﻢﻫﺎي ﻛﻤﻜﻲ دﻳﮕﺮي در ﻧﻴﺮوﮔﺎه ﻣﻮرد ﻧﻴﺎز ﻣﻲﺑﺎﺷﻨﺪ ﻛﻪ در‬
‫ﻃﺮاﺣﻲ ﻛﻠﻲ ﻳﻚ ﻧﻴﺮوﮔﺎه آﺑﻲ ﺑﺎﻳﺪ ﻣﻮرد ﺑﺮرﺳﻲ دﻗﻴﻖ ﻗﺮار ﮔﻴﺮﻧﺪ‪ .‬در اداﻣﻪ ﻣﻬﻤﺘﺮﻳﻦ اﻳﻦ ﺳﻴﺴﺘﻢﻫﺎ ﻣﻌﺮﻓﻲ و ﺗﺸﺮﻳﺢ ﺧﻮاﻫﺪ ﺷﺪ‪.‬‬

‫‪۴٠‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -1-10‬ﺳﻴﺴﺘﻢ آب ﺧﻨﻚ ﻛﻨﻨﺪه )‪(cooling water system‬‬


‫اﻳﻦ ﺳﻴﺴﺘﻢ آب ﻣﺼﺮﻓﻲ ﻗﺴﻤﺖ ﻫﺎي ﻣﺨﺘﻠﻒ ﻧﻴﺮوﮔﺎه را در ﻣﻮارد زﻳﺮ ﻓﺮاﻫﻢ ﻣﻲﻧﻤﺎﻳﺪ‪.‬‬

‫‪ -1‬ﻛﻮﻟﺮﻫﺎي ﻳﺎﺗﺎﻗﺎنﻫﺎي ژﻧﺮاﺗﻮر ‪(Generator combined & upper(Lower) Guide bearing‬‬


‫)‪cooler‬‬

‫‪-2‬ﻛﻮﻟﺮﻫﺎي ﻫﻮا‪-‬آب ژﻧﺮاﺗﻮر)‪(Generator air-water cooler‬‬

‫‪-3‬ﻛﻮﻟﺮﻫﺎي ﻳﺎﺗﺎﻗﺎن ﺗﻮرﺑﻴﻦ)‪(Turbine guide bearing‬‬

‫‪ -4‬ﻛﻮﻟﺮﻫﺎي روﻏﻦ ﮔﺎورﻧﺮﻫﺎ)‪(Governor oil cooler‬‬

‫آب ﻣﻮرد ﻧﻴﺎز ﺑﺮاي ﻛﻮﻟﺮﻫﺎي روﻏﻦ ﻳﺎﺗﺎﻗﺎنﻫﺎي ﺗﻮرﺑﻴﻦ و ژﻧﺮاﺗﻮ ‪،‬ﻛﻮﻟﺮﻫﺎي روﻏﻦ ﮔﺎورﻧﺮﻫﺎ ‪ ،‬ﻛﻮﻟﺮﻫﺎي ﻫﻮا‪-‬آب ژﻧﺮاﺗﻮر ﺗﻮﺳﻂ‬
‫ﺳﻴﺴﺘﻢ آب ﺧﻨﻚ ﻛﻨﻨﺪه ﺗﺎﻣﻴﻦ ﻣﻲ ﮔﺮدد‪ .‬در ﻫﻤﺔ اﻳﻦ ﺳﻴﺴﺘﻢﻫﺎ‪ ،‬ﻣﻴﺰان ﻧﻴﺎزﻣﻨﺪﻳﻬﺎ و ﺗﺠﻬﻴﺰات ﻣﺼﺮف ﻛﻨﻨﺪه ﺗﻮﺳﻂ ﺳﺎزﻧﺪﮔﺎن‬
‫ﺗﻮرﺑﻴﻦ و ژﻧﺮاﺗﻮر ﺗﻌﻴﻴﻦ ﻣﻲﮔﺮدﻧﺪ‪.‬‬

‫در اﻳﻦ ﭘﺮوﮋه ﺑﻌﻠﺖ ﻇﺮﻓﻴﺖ ﭘﺎﻳﻴﻦ‪ ،‬ﺑﺮاي ﺗﺎﻣﻴﻦ آب ﺳﻴﺴﺘﻢ ﺧﻨﻚ ﻛﻨﻨﺪه ‪،‬ﻳﻚ اﻧﺸﻌﺎب از ﺑﺎﻻ دﺳﺖ ﺷﻴﺮ ﭘﺮواﻧﻪاي ﮔﺮﻓﺘﻪ ﺷﺪه و ﺑﺎ‬
‫اﻓﺖ ﻓﺸﺎر در ﺷﻴﺮ ﻓﺸﺎر ﺷﻜﻦ‪ ،‬آب ﻣﺼﺮﻓﻲ ﻣﻮرد ﻧﻴﺎز ﺗﺠﻬﻴﺰات را ﺗﺎﻣﻴﻦ ﻣﻲ ﻧﻤﺎﻳﻨﺪ‬

‫‪ -2-10‬ﺳﻴﺴﺘﻢ ﺗﺨﻠﻴﻪ و زه ﻛﺸﻲ )‪(Dewatering and drainage system‬‬


‫اﻳﻦ ﺳﻴﺴﺘﻢ ﺑﺮاي ﺗﺨﻠﻴﻪ آب ﺗﻮرﺑﻴﻨﻬﺎ و آﺑﺮاﻫﻪ ﻫﺎ ﺑﻪ ﻣﻨﻈﻮر ﺑﺎزرﺳﻲ‪ ،‬ﻧﮕﻬﺪاري و ﻫﻤﭽﻨﻴﻦ ﺟﻤﻊ آوري و دﻓﻊ ﻧﺸﺘﻲﻫﺎ و ﻓﺎﺿﻼب‬
‫ﻧﻴﺮوﮔﺎه ﺑﻪ ﺟﺰ ﻓﺎﺿﻼب ﻫﺎي ﺑﻬﺪاﺷﺘﻲ ﺑﻪ ﻛﺎر ﻣﻲ رود‪ .‬در اﻳﻦ ﺳﻴﺴﺘﻢ آب ﻫﺎي ﻧﺸﺘﻲ و ﻫﻤﭽﻨﻴﻦ آب ﺗﻮرﺑﻴﻦ ﻫﺎ و ﻟﻮﻟﻪ آﺑﺮﺳﺎن ﺑﻪ‬
‫داﺧﻞ ﻳﻚ ﭼﺎﻫﻚ ﻛﻪ در ﭘﺎﻳﻴﻦ ﺗﺮﻳﻦ ﻗﺴﻤﺖ ﻧﻴﺮوﮔﺎه ﻗﺮاردارد‪ ،‬ﺗﺨﻠﻴﻪ ﻣﻲ ﺷﻮﻧﺪ و ﺗﻮﺳﻂ ﭘﻤﭙﻬﺎﻳﻲ ﻛﻪ در ﭼﺎﻫﻚ ﻧﺼﺐ ﺷﺪه اﻧﺪ‬
‫ﺑﻪ ﭘﺎﻳﻴﻦ دﺳﺖ ﻟﻮﻟﻪ ﻫﺎي ﻣﻜﺶ )‪ (Draft tube‬ﺗﺨﻠﻴﻪ ﻣﻲ ﮔﺮدﻧﺪ‪ .‬ﻛﻠﻴﺔ ﺗﺠﻬﻴﺰات ﻣﺮﺑﻮط ﺑﻪ ﺗﺨﻠﻴﻪ آب ﻧﻴﺮوﮔﺎه در ﺳﺮاﺳﺮ‬
‫ﻣﺴﻴﺮﻫﺎي واﺑﺴﺘﻪ ﺑﺎﻳﺴﺘﻲ ﻃﻮري اﻧﺘﺨﺎب ﮔﺮدﻧﺪ ﺗﺎ در آﻳﻨﺪه ﻫﻴﭽﮕﻮﻧﻪ ﻣﺸﻜﻞ ﺑﻬﺮه ﺑﺮداري در اﻳﻦ زﻣﻴﻨﻪ رخ ﻧﺪﻫﺪ‪ .‬ﭘﻤﭗﻫﺎي‬
‫ﺗﺨﻠﻴﺔ آب از ﻣﺨﺰن ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻣﻘﺪار آب و زﻣﺎن ﻣﻮرد ﻧﻴﺎز ﺑﺮاي ﺗﺨﻠﻴﻪ و ﻫﺪ ﻻزم اﻧﺘﺨﺎب مي ﮔﺮدﻧﺪ‪ .‬ﻣﻌﻤﻮﻻً ﺗﺮﻛﻴﺒﻲ از ﭼﻨﺪ‬
‫ﭘﻤﭗ ﺑﻪ ﻛﺎر ﻣﻲ رود‪ .‬ﺧﺎﻣﻮش و روﺷﻦ ﺷﺪن ﭘﻤﭗ ﻫﺎ ﺑﻪ ﻃﻮر اﺗﻮﻣﺎﺗﻴﻚ ﺑﺎ ﻛﻨﺘﺮل ﺳﻮﺋﻴﭽﻬﺎي ﺗﺮاز ﺳﻨﺞ آب)‪(Level swi t ch‬‬
‫در ﻣﺨﺰن اﻧﺠﺎم ﻣﻲﮔﻴﺮﻧﺪ‪ .‬اﻳﻦ ﭘﻤﭗﻫﺎ ﺑﺎﻳﺴﺘﻲ ﺑﺘﻮاﻧﻨﺪ ﺑﻪ ﻃﻮر ﭘﻴﻮﺳﺘﻪ و ﻣﺘﻨﺎوب ﻛﺎر ﻧﻤﻮده و در ﻣﺴﻴﺮ ﺧﺮوﺟﻲ آﻧﻬﺎ از ﺷﻴﺮﻫﺎي‬
‫ﻳﻚ ﻃﺮﻓﻪ‪،‬ﻓﺸﺎر ﺳﻨﺞ اﺳﺘﻔﺎده ﮔﺮدد‪.‬‬

‫‪۴١‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫‪ -3-10‬ﺳﻴﺴﺘﻢ ﻫﺎي ﻫﻮاي ﻓﺸﺮده )‪(Compressed air systems‬‬


‫ﺳﻴﺴﺘﻢﻫﺎي ﻫﻮاي ﻓﺸﺮده در ﻧﻴﺮوﮔﺎﻫﻬﺎ ﺑﺮاي ﺑﻬﺮه ﺑﺮداري و ﻛﻤﻚ ﺑﻪ ﻧﮕﻬـﺪاري و ﺗﻌﻤﻴـﺮات ﺑﻪ ﻛﺎر ﻣﻲ روﻧﺪ‪ .‬در اﻳﻦ ﻧﻴﺮوﮔﺎه‬
‫ﺳﻴﺴﺘﻢ ﻫﻮاي ﺳﺮوﻳﺲ و ﻫﻮاي ﺗﺮﻣﺰ ژﻧﺮاﺗﻮر ﻣﻮرد ﻧﻴﺎز ﻣﻲ ﺑﺎﺷﻨﺪ‪ .‬ﻗﺎﺑﻠﻴﺖ اﻋﺘﻤﺎد‪ ،‬ﻛﺎرﻛﺮد آﺳﺎن و اﻳﻤﻨﻲ از اﺻﻮل اوﻟﻴﻪ ﻃﺮاﺣﻲ‬
‫اﻳﻦ ﺳﻴﺴﺘﻢﻫﺎ ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫‪ -4-10‬ﺳﻴﺴﺘﻢ ﻫﻮاي ﺳﺮوﻳﺲ‬


‫ﺳﻴﺴﺘﻢ ﻫﻮاي ﺳﺮوﻳﺲ‪ ،‬ﻫﻮاي ﻣﻮرد ﻧﻴﺎز ﺑﺮاي ﺗﻌﻤﻴﺮات‪ ،‬و ﺳﻴﺴﺘﻢ ﻫﻮاي ﺗﺮﻣﺰ و ﻫﻤﭽﻨﻴﻦ ﻫﻮاي ﻻزم ﺑﺮاي‬
‫‪ maintenance seal‬را ﺗﺎﻣﻴﻦ ﻣﻲﻧﻤﺎﻳﺪ‪ .‬ﺑﻴﺸﺘﺮ ﻛﺎر ﺑﺮد اﻳﻦ ﺳﻴﺴﺘﻢ ﺑﺮاي ﺗﺎﻣﻴﻦ ﻫﻮا در ﺷﺮاﻳﻂ ﺗﻌﻤﻴﺮات ﻣﻲ ﺑﺎﺷﺪ ﻛﻪ ﻫﻮاي‬
‫ﻣﻮرد ﻧﻴﺎز ﺑﺮاي ﺳﻨﺪ ﺑﻼﺳﺖ‪ ،‬رﻧﮓ زﻧﻲ‪ ،‬ﺗﻤﻴﺰﻛﺎري و … را ﺗﺎﻣﻴﻦ ﻣﻲ ﻧﻤﺎﻳﺪ‪ .‬در ﺷﺮاﻳﻂ ﺑﻬﺮه ﺑﺮداري ﻧﻴﺮوﮔﺎه اﻳﻦ ﺳﻴﺴﺘﻢ ﺑﺎﻳﺴﺘﻲ‬
‫ﻫﻮاي ﻻزم ﺷﺎرژ ﻣﺨﺰن ﻫﻮاي ﺳﻴﺴﺘﻢ ﺗﺮﻣﺰ را ﺗﺎﻣﻴﻦ ﻧﻤﺎﻳﺪ‪.‬ﻣﻌﻤﻮﻻً ﻓﺸﺎر ﻫﻮاي ﺳﺮوﻳﺲ در ﺣﺪود ‪ 8‬ﺑﺎر ﻣﻲﺑﺎﺷﺪ‪.‬ﻛﻤﭙﺮﺳﻮرﻫﺎ ﺑﺎﻳﺴﺘﻲ‬
‫ﺑﺮاي ﻛﺎر در ﺷﺮاﻳﻂ ﺳﺨﺖ اﻧﺘﺨﺎب ﺷﻮﻧﺪ‪ .‬اﻳﻦ ﻛﻤﭙﺮﺳﻮرﻫﺎ ﺑﻬﺘﺮ اﺳﺖ ﻛﺎرﻛﺮد ﭘﻴﻮﺳﺘﻪاي داﺷﺘﻪ ﺑﺎﺷﻨﺪ‪.‬‬

‫‪ -5-10‬ﺳﻴﺴﺘﻢ ﻫﻮاي ﺗﺮﻣﺰ‬

‫ﺳﻴﺴﺘﻢ ﻫﻮاي ﺗﺮﻣﺰ ﺷﺎﻣﻞ ﻳﻚ ﻣﺨﺰن ﺗﺤﺖ ﻓﺸﺎر و ﺗﻮزﻳﻊﻛﻨﻨﺪه ﻣﺮﺑﻮﻃﻪ ﺑﺮاي ﺗﺎﻣﻴﻦ ﻫﻮاي ﻣﻮرد ﻧﻴﺎز ﺗﺮﻣﺰ ژﻧﺮاﺗﻮر ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﻫﻮاي‬

‫اﻳﻦ ﺳﻴﺴﺘﻢ ﺗﻮﺳﻂ ﺳﻴﺴﺘﻢ ﻫﻮاي ﺳﺮوﻳﺲ ﺗﺎﻣﻴﻦ و ذﺧﻴﺮه ﺷﺪه و ﺳﭙﺲ ﺑﻪ ﺗﺮﻣﺰ ژﻧﺮاﺗﻮر ﺗﻘﺴﻴﻢ ﻣﻲﮔﺮدد‪ .‬در اﻳﻦ ﺳﻴﺴﺘﻢ ﻫﻮا ﺑﺎﻳﺪ‬

‫ﺑﺮاي ﺗﻮﻗﻒ ﻫﺮ دو واﺣﺪ ﺗﻮرﺑﻴﻦ ژﻧﺮاﺗﻮر ﺑﺪون اﻓﺰودن ﻫﻮا ﺑﻪ ﺳﻴﺴﺘﻢ و ﺑﺪون ﻛﺎﻫﺶ ﻓﺸﺎر ﻣﺠﺎز آن ﺗﺎﻣﻴﻦ ﺷﻮد‪.‬‬

‫‪ -6-10‬ﺳﻴﺴﺘﻢ روﻏﻦ‬

‫ﺳﻴﺴﺘﻢ روﻏﻦ ﺑﺮاي ﺗﺄﻣﻴﻦ روﻏﻦ ﮔﺎورﻧﺮ‪ ،‬ﺷﻴﺮ ورودي و روﻏﻦﻛﺎري ﻳﺎﺗﺎﻗﺎنﻫﺎ )‪ (governor–lube oil‬ﻣﻲﺑﺎﺷﺪ ﻛﻪ‬

‫ﺑﺮاي روﻏﻦﻛﺎري ﺗﺠﻬﻴﺰات واﺣﺪ و ﮔﺎورﻧﺮ‪ ،‬ﺷﻴﺮ ورودي ﭘﻴﺶﺑﻴﻨﻲ ﺷﺪه اﺳﺖ‪ .‬در اﻳﻦ ﻧﻴﺮوﮔﺎه ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻛﻮﭼﻚ ﺑﻮدن‬

‫ﻧﻴﺎزي ﺑﻪ اﺳﺘﻔﺎده از ﻟﻮﻟﻪ ﻛﺸﻲ روﻏﻦ ﻧﺒﻮده و ﻣﻲ ﺗﻮان ﺑﺸﻜﻪ ﻫﺎي روﻏﻦ را ﺑﻪ ﺻﻮرت دﺳﺘﻲ ﺑﻪ ﻛﻨﺎر ﺗﺠﻬﻴﺰات ﻣﻮرد‬

‫ﻧﻈﺮ ﻣﻨﺘﻘﻞ و از ﻃﺮﻳﻖ ﭘﻤﭗ ﻗﺎﺑﻞ ﺣﻤﻞ و ﻧﻘﻞ)‪ (portable‬روﻏﻦ را ﺑﻪ ﺗﺠﻬﻴﺰات رﺳﺎﻧﻴﺪ‪.‬‬

‫‪ --7-10‬ﺟﺮﺛﻘﻴﻞ ﻧﻴﺮوﮔﺎه‬

‫ﺑﺮاي ﻧﺼﺐ و ﭘﻴﺎده ﻛﺮدن ﺗﻮرﺑﻴﻦ ژﻧﺮاﺗﻮر و ﺗﺠﻬﻴﺰات ﻛﻤﻜﻲ ﻧﻴﺮوﮔﺎه‪ ،‬ﻳﻚ ﺟﺮﺛﻘﻴﻞ ﺳﻘﻔﻲ ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﺪه اﺳﺖ‪ .‬ﻇﺮﻓﻴﺖ ﺟﺮﺛﻘﻴﻞ‬

‫ﺑﺮ اﺳﺎس ﺳﻨﮕﻴﻦ ﺗﺮﻳﻦ ﻗﻄﻌﻪ ﻧﻴﺮوﮔﺎه ﻛﻪ ژﻧﺮاﺗﻮر اﺳﺖ‪ ،‬ﺑﺮاي ﻧﻴﺮوﮔﺎه ﻗﻄﻌﻪ ﺳﻮم ﺣﺪوداً ‪ 12‬ﺗﻦ و ﺑﺮاي ﻧﻴﺮوﮔﺎه ﻗﻄﻌﻪ ﭼﻬﺎرم ﺣﺪوداً‬

‫‪ 10‬ﺗﻦ ﭘﻴﺶ ﺑﻴﻨﻲ ﻣﻲ ﮔﺮدد‪ .‬ﻻزم ﺑﻪ ﺗﻮﺿﻴﺢ اﺳﺖ ﻛﻪ ﻣﺸﺨﺼﺎت ﺟﺮﺛﻘﻴﻞ )ﻇﺮﻓﻴﺖ‪،‬دﻫﺎﻧﻪ و ﺗﺮاز ﻧﺼﺐ رﻳﻞ(‪ ،‬ﺑﻪ ﺗﻮﺟﻪ ﺑﻪ ﻧﻈﺮات‬

‫ﻧﻬﺎﻳﻲ ﺳﺎزﻧﺪه ژﻧﺮاﺗﻮر ﺗﺪﻗﻴﻖ ﺧﻮاﻫﺪ ﺷﺪ‪.‬‬

‫‪۴٢‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫ﺑﻪ ﺟﻬﺖ ﭘﻮﺷﺶ ﻛﻞ ﺳﺎﻟﻦ ﺗﻮﺳﻂ ﺟﺮﺛﻘﻴﻞ‪ ،‬ﻛﻞ ﺳﺎﻟﻦ رﻳﻞ ﮔﺬاري ﺷﺪه و در اﻧﺘﻬﺎي ﻣﺴﻴﺮ ﺣﺮﻛﺖ ﺟﺮﺛﻘﻴﻞ ﻧﻴﺰ ﺿﺮﺑﻪ ﮔﻴﺮ ﺗﻌﺒﻴﻪ ﻣﻲ‬

‫ﺷﻮد‪.‬اﻳﻦ ﺟﺮﺛﻘﻴﻞ ﺗﻤﺎﻣﻲ ﺳﻄﺢ ﻧﻴﺮوﮔﺎه را ﭘﻮﺷﺶ ﻣﻲ دﻫﺪ‪ .‬ﺳﺎزه اﺻﻠﻲ ﺟﺮﺛﻘﻴﻞ از دو ﺗﻴﺮ اﺻﻠﻲ ﺗﺸﻜﻴﻞ ﺷﺪه ﻛﻪ ﺑﺎ ﻣﻘﻄﻊ ﻣﺮﺑﻊ و ﻳﺎ‬

‫‪ I‬ﺷﻜﻞ ﻣﻲ ﺑﺎﺷﻨﺪ ﻛﻪ ﺑﺎورق ﻓﻮﻻدي ﺳﺎﺧﺘﻪ ﻣﻲ ﺷﻮﻧﺪ ‪.‬ﺳﻴﺴﺘﻢ ﺑﺎﻻﺑﺮ اﺻﻠﻲ ﺟﺮﺛﻘﻴﻞ ﺑﺮ روي ﻳﻚ ﻛﺎﻟﺴﻜﻪ ﻛﻪ در ﻃﻮل ﺗﻴﺮ اﺻﻠﻲ‬

‫ﺟﺮﺛﻘﻴﻞ ﺣﺮﻛﺖ ﻣﻲ ﻧﻤﺎﻳﺪ‪ ،‬ﻧﺼﺐ ﻣﻲ ﺷﻮد ‪.‬ﻛﺎﻟﺴﻜﻪ ﺗﻮﺳﻂ ﺳﺎزه ﻫﺎي ﺳﺎﺧﺘﻤﺎﻧﻲ و ﻳﺎ ﺗﻴﺮ ورق ﺳﺎﺧﺘﻪ ﻣﻲ ﺷﻮد و ﻗﺎدر ﺑﻪ ﺗﺤﻤﻞ‬

‫درام و ﺑﻘﻴﻪ ﺗﺠﻬﻴﺰات ﻣﻜﺎﻧﻴﻜﻲ ﺑﺎﻻﺑﺮ ﺧﻮاﻫﺪ ﺑﻮد ‪.‬روي ﺗﻴﺮ اﺻﻠﻲ‪ ،‬رﻳﻞ ﺟﻬﺖ ﻫﺪاﻳﺖ ﻛﺎﻟﺴﻜﻪ ﺟﻮش ﻣﻲ ﺷﻮد ‪.‬ﻛﺎﻟﺴﻜﻪ ﺟﺮﺛﻘﻴﻞ‬

‫ﺗﻮﺳﻂ ﻳﻚ ﻳﺎ دو ﻣﻮﺗﻮر ﮔﻴﺮﺑﻜﺲ ﺑﻪ ﺣﺮﻛﺖ در ﻣﻲ آﻳﺪ ‪.‬راﻫﺮو و ﻧﺮدﺑﺎﻧﻬﺎي ﻓﻠﺰي ﻣﻨﺎﺳﺐ در ﺟﺮﺛﻘﻴﻞ ﺗﻌﺒﻴﻪ ﻣﻲ ﺷﻮد ﺗﺎ اﻣﻜﺎن‬

‫ﺑﺎزرﺳﻲ و ﺗﻌﻤﻴﺮات ﺗﻤﺎم ﻗﺴﻤﺘﻬﺎي ﺟﺮﺛﻘﻴﻞ ﻓﺮاﻫﻢ ﺷﻮد‪ .‬درام ﺟﺮﺛﻘﻴﻞ ﺑﻪ ﻧﺤﻮي ﻃﺮاﺣﻲ ﻣﻲ ﺷﻮد ﻛﻪ رﻳﺴﻤﺎن ﻛﺎﻓﻲ ﺑﺮاي‬

‫ﺣﺮﻛﺖ ﻗﻼب ﺗﺎ ﭘﺎﺋﻴﻦ ﺗﺮﻳﻦ ﻧﻘﻄﻪ ﻣﻮرد ﻧﻴﺎز را ﺑﻪ دور ﺧﻮد ﭘﻴﭽﻴﺪه ﺑﺎﺷﺪ و در اﻧﺘﻬﺎي ﻣﺴﻴﺮ ﻧﻴﺰ ﻫﻨﻮز دو ردﻳﻒ رﻳﺴﻤﺎن ﺑﺎﻗﻲ‬

‫ﺑﻤﺎﻧﺪ ‪.‬ﺷﻴﺎرﻫﺎي درام ﺑﺸﻜﻞ ﭼﭗ ﮔﺮد ﻳﺎ راﺳﺖ ﮔﺮد ﺑﺎ ﻋﻤﻖ ﻣﻨﺎﺳﺐ ﺑﺮ روي درام ﻣﺎﺷﻴﻨﻜﺎري ﻣﻲ ﺷﻮﻧﺪ ‪.‬رﻳﺴﻤﺎن ﺟﺮﺛﻘﻴﻞ‬

‫ﻣﻄﺎﺑﻖ اﺳﺘﺎﻧﺪارد ‪ DIN 21251‬ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫ﻗﻼب ﺑﺎﻻﺑﺮ اﺻﻠﻲ ﺟﺮﺛﻘﻴﻞ از ﻧﻮع دوﺑﻞ ﺑﺸﻜﻞ ﻓﻮرج ﺷﺪه ﺑﺎ ﻗﺎﺑﻠﻴﺖ ‪ 360‬دوران ﺣﻮل ﺧﻮد ﻣﻲ ﺑﺎﺷﺪ ‪.‬ﻗﻼب ﺑﺎﻻﺑﺮ ﻛﻤﻜﻲ ﺑﺸﻜﻞ‬

‫ﺳﺎده و ﻓﻮرج ﺷﺪه ﺧﻮاﻫﺪ ﺑﻮد ‪.‬ﺗﺮﻣﺰ اﺻﻠﻲ ﺟﺮﺛﻘﻴﻞ از ﻧﻮع اﻟﻜﺘﺮوﻣﻜﺎﻧﻴﻜﻲ ﺑﺎ ﻗﺪرت ﺣﺪاﻗﻞ ‪ % 100‬ﺗﺮك ﻧﺎﻣﻲ ﻣﻮﺗﻮر اﺳﺖ و ﻗﺎدر‬

‫ﺑﻪ ﻧﮕﻬﺪاري ﺑﺎر در ﺗﻤﺎم ﺣﺎﻻت و ﻫﺮ ﻧﻘﻄﻪ و ﺑﻬﻨﮕﺎم و ﺑﺎﻻ ﻳﺎ ﭘﺎﺋﻴﻦ رﻓﺘﻦ ﺑﺎر ﻣﻲ ﺑﺎﺷﺪ ‪.‬ﺗﺮﻣﺰ در ﺻﻮرت ﻗﻄﻊ ﺑﺮق ﺑﻄﻮر ﺧﻮدﻛﺎر‬

‫ﻗﻔﻞ ﻣﻲ ﺷﻮد ‪.‬ﺗﺮﻣﺰﻫﺎي ﺣﺮﻛﺘﻲ ﺟﺮﺛﻘﻴﻞ ﻧﻴﺰ از ﻧﻮع اﻟﻜﺘﺮوﻣﻜﺎﻧﻴﻜﻲ ﺑﺎ ﺗﻮان ﺗﻮﻗﻒ ﺟﺮﺛﻘﻴﻞ و ﺑﺎر ﺣﺪاﻛﺜﺮ‪ ،‬ﺑﺪون ﻟﻐﺰش در‬

‫ﭼﺮﺧﻬﺎﺳﺖ‪.‬‬
‫ﺟﺮﺛﻘﻴﻞ ﻣﺠﻬﺰ ﺑﻪ ﺳﻮﺋﻴﭽﻬﺎي ﺣﺪي ﺑﺮاي ﺣﺮﻛﺖ ﺟﺮﺛﻘﻴﻞ و ﺣﺮﻛﺖ ﺑﺎﻻﺑﺮ ﻣﻲ ﺑﺎﺷﺪ ‪.‬ﺳﻮﺋﻴﭽﻬﺎي ﺣﺪي ﺑﺮاي ﺣﺮﻛﺖ ﺟﺮﺛﻘﻴﻞ‪،‬‬

‫ﻣﺤﺪوده ﺣﺮﻛﺖ ﺟﺮﺛﻘﻴﻞ در دو اﻧﺘﻬﺎي رﻳﻞ را ﻣﺸﺨﺺ ﻣﻲ ﻧﻤﺎﻳﺪ ‪.‬ﺳﻮﺋﻴﭻ ﺣﺮﻛﺘﻲ ﺑﺎﻻﺑﺮ ﻛﻪ ﻣﺴﺘﻘﻴﻤﺎ " از ﺳﻴﺴﺘﻢ ﺑﺎﻻﺑﺮ ﺗﺤﺮﻳﻚ‬

‫ﻣﻲ ﺷﻮد ﺣﺮﻛﺖ ﺣﺪي ﻗﻼب را در ﭘﺎﺋﻴﻦ ﺗﺮﻳﻦ ﻧﻘﻄﻪ و ﺑﺎﻻﺗﺮﻳﻦ ﻧﻘﻄﻪ ﺑﻪ ﻧﺤﻮي ﻣﺤﺪود ﻣﻲ ﻛﻨﺪ ﻛﻪ در ﭘﺎﺋﻴﻦ ﺗﺮﻳﻦ ﻧﻘﻄﻪ ﻗﻼب‪،‬‬

‫ﺣﺪاﻗﻞ دو ﺣﻠﻘﻪ رﻳﺴﻤﺎن در درام ﺑﺎﻗﻴﻤﺎﻧﺪه و در ﺑﺎﻻﺗﺮﻳﻦ ﻧﻘﻄﻪ ﻗﻼب ﺣﺪاﻗﻞ دو ﺷﻴﺎر ﺧﺎﻟﻲ در درام ﻣﻮﺟﻮد ﻣﻲ ﺑﺎﺷﺪ ‪.‬ﻳﻚ‬

‫ﺳﻮﺋﻴﭻ ﺣﺪي دﻳﮕﺮ در ﻣﺴﻴﺮ ﺣﺮﻛﺖ ﻗﻼب ﺑﻪ ﻧﺤﻮي ﻗﺮار ﻣﻲ ﮔﻴﺮد ﻛﻪ از ﺑﺮﺧﻮرد آن ﺑﻪ ﻛﺎﻟﺴﻜﻪ ﺟﻠﻮﮔﻴﺮي ﻣﻲ ﻧﻤﺎﻳﺪ‪.‬‬

‫‪۴٣‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫ﭘﻴﻮﺳﺖ اﻟﻒ‪ :‬اﺑﻌﺎد و ﻣﺸﺨﺼﺎت اﺟﺰاي اﺻﻠﻲ ﺗﻮرﺑﻴﻦ‬


‫ﻧﻴﺮوﮔﺎه ﻗﻄﻌﻪ ﺳﻮم‬

‫‪۴۴‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(۶‬اطالعات توان و جدول راندمان توربين‬

‫‪۴۵‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪-(٧‬جدول مشخصات و ابعاد توربين‬

‫‪۴۶‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(٨‬نمای کلی توربين و اجزای مربوطه‬

‫‪۴٧‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(٩‬نمای کلی توربين و اجزای مربوطه‬

‫‪۴٨‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(١٠‬نحوه استقرار توربين ‪-‬ژنراتور‬

‫‪۴٩‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(١١‬اجزای نازل توربين‬

‫‪۵٠‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(١٢‬منحنی عملکرد توربين)ھيل چارت(‬

‫‪۵١‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫ﭘﻴﻮﺳﺖ ب‪ :‬اﺑﻌﺎد و ﻣﺸﺨﺼﺎت اﺟﺰاي اﺻﻠﻲ ﺗﻮرﺑﻴﻦ‬


‫ﻧﻴﺮوﮔﺎه ﻗﻄﻌﻪ ﭼﻬﺎرم‬

‫‪۵٢‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(١٣‬اطالعات توان و جدول راندمان توربين‬

‫‪۵٣‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(١۴‬جدول مشخصات و ابعاد توربين‬

‫‪۵۴‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(١۵‬نمای کلی توربين و اجزای مربوطه‬

‫‪۵۵‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(١۶‬نمای کلی توربين و اجزای مربوطه‬

‫‪۵۶‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(١٧‬نحوه استقرار توربين ‪-‬ژنراتور‬

‫‪۵٧‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(١٨‬اجزای نازل توربين‬

‫‪۵٨‬‬
‫ﻃﺮح اﻣﻜﺎن ﺳﻨﺠﻲ اﺣﺪاث ﻧﻴﺮوﮔﺎه ﺑﺮﻗﺎﺑﻲ ﻛﻮﭼﻚ ﺧﻂ اﻧﺘﻘﺎل آب از ﺳﺪ ﺻﻔﺎرود ﺑﻪ ﺷﻬﺮ ﻛﺮﻣﺎن‬

‫شکل)‪ -(١٩‬منحنی عملکرد توربين)ھيل چارت(‬

‫‪۵٩‬‬