APPROVAL COLUMN

A B 13 C D E
5488 5113 5000 5000 5000
1275
4Y20-02 4Y20-02
03

03 4Y20-02 4Y20-02
27Y8-70-200 c/c links 26Y8-70-200 c/c links 25Y8-70-200 c/c links 25Y8-70-200 c/c links 25Y8-70-200 c/c links

BEAM 1 (225x450) 2 NOS THUS

E' F G I G I
4750 5000 5000 5000
4Y20-03 3Y16-01
02 03

02 4Y20-03 03 3Y20-04
24Y8-70-200 c/c links 25Y8-70-200 c/c links 25Y8-70-200 c/c links 25Y8-70-200 c/c links

BEAM 2 (225x450) 2 NOS THUS BEAM 3 (225x450) 6 NOS THUS

A A' 13 13' G H I
4675 5925 3825 2500 2500
1175 1525 1525 975
2Y16-01 3Y20-09 2Y16-01 3Y20-09 2Y16-01 2Y16-12
2Y20-09 2Y20-09
04 07

04 2Y20-10
3Y20-10 2Y16-12 07
23Y8-70-200 c/c links 30Y8-70-200 c/c links 19Y8-70-200 c/c links 13Y8-70-200 c/c links 13Y8-70-200 c/c links 1.EACH STAGE OF CONSTRUCTION OF THESE
WORKS MUST BE APPROVED BY THE ENGINEER
BEAM 4 (225x600) 2 NOS THUS BEAM 7 (225x450) 2 NOS THUS BEFORE ANOTHER STAGE IS STARTED.

2.ALL DIMENSIONS ARE IN MM EXCEPT


OTHERWISE STATED.

3.ALL STRUCTURAL CONCRETE MUST BE 1: 2: 4


A B 13 MIX WITH MAX.
5488 5113 ACHIEVING Fcu=25N/MMSQ AT 28 DAYS.
1275 1275
3Y16-01 3Y20-09 3Y16-01 4.ALL AGGREGATE FOR THE WORK SHALL BE
2Y20-09 CLEAN AND FREE FROM DUST,SILT OR CLAY.
05
5.WATER FOR THE WORK SHALL BE CLEAN
DRINKABLE WATER.

05 2Y20-10 6.REINFORCEMENT STEEL SHALL BE EITHER


3Y20-10 Y=HIGH TENSILE RIBBED STEEL
27Y8-70-200 c/c links 26Y8-70-200 c/c links
Fy=410N/MMSQ MIN.
OR
BEAM 5 (225x600) 2 NOS THUS R=ROUND MILD STEEL Fy=250N/MMSQ

7.CEMENT OF DIFFERENT BRAND SHALL NOT


BE MIX TOGETHER IN THE SAME BATCH.

8. B= BOTTOM, T=TOP.
DWG TITLE:
PRIME CONSULTANT:
CLIENT: PROJECT: LOCATION:
GALLRY FLOOR BEAM DETAIL
HORTUS berth Ltd DRAWN BY: DATE: DWG NO

OFF AKIN ADESOLA STREET, MORGAN CHYDE


JUNE, 2024.
3a Chike Egwuonwu Crescent Trans-Ekulu Enugu.
DESIGNED BY:

IKOYI FALOMO,ETI-OSA LGA, LONGY


JOB NO:
018
LAGOS STATE.
CHECKED BY:

ENGR R.T
22- 0057