Instruction book

11 Technical data

11.1 Readings

Important

The readings below are indicative values when operating at reference conditions. Check
the section Reference conditions. These values are no rejection limits. In case of doubt,
consult your Atlas Copco Customer Center.

For the maximum working pressure and the outlet pressure, consult the section Compressor
data.
Pressure readings

Item Reading
dp of air filter Below 0.044 bar
Intercooler pressure (loaded condition) 1.7-3 bar(e)
Intercooler pressure (unloaded condition) (-0.65)-(-0.70) bar(e)
Oil pressure (depends on climatic conditions) 1.8-3.5 bar(e)

Temperature readings for ZR compressors

Item Reading
Oil temperature Approx. 40 ˚C
Air outlet temperature Approx. 25 ˚C
Cooling water inlet temperature Below 40 ˚C
Cooling water outlet temperature Below 50 ˚C

11.2 Settings of safety valves

Item Opening
pressure
Low-pressure safety valve(s) for 7 up to 10.4 bar (101.5 up to 3.7 bar(e)
151 psi) compressors
High-pressure safety valve(s) for 10 and 10.4 bar (145 and 11 bar(e)
151 psi) compressors

APF236826 181
Instruction book

11.3 Settings for overload relay

50 Hz compressors
ZT/ZR 132 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE2
motor

Supply voltage Recommended overload setting F21


(V) (A)
400 146.1

ZT/ZR 132 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE3
motor

Supply voltage Recommended overload setting F21


(V) (A)
400 146

11.4 Reference conditions

Absolute inlet pressure 1 bar(a)


Ambient temperature 20 °C
Air inlet temperature 20 °C
Effective working pressure 9 bar(g) for 10/10.4 bar compressors
Temperature of cooling medium (water or air) inlet 20 °C
Temperature rise of cooling water of ZR Pack 15 °C
compressors
ZR / ZT 110-145
Motor shaft speed for 50 Hz fixed speed compressors 2980
(rpm)

11.5 Limitations
Minimum - maximum ambient temperature (for 0 - 40 °C
standard compressors)
Minimum - maximum temperature of air inlet (for 0 - 40 °C
standard compressors)
Maximum altitude 1000 m
Minimum temperature of cooling medium (water or 0 °C
air) inlet
Maximum temperature of cooling air inlet (for 40 °C
standard compressors)
Maximum temperature of cooling water inlet - open 40 °C
circuit

182 APF236826
Instruction book

Maximum temperature of cooling water outlet 50 °C


Maximum rise of cooling water temperature (for up to 35 °C
compressors without Energy Recovery)
Maximum pressure of cooling water inlet 10 bar(g)
Minimum - maximum oil pressure 1.2–4.5 bar(g)
Minimum - maximum oil temperature (for standard 0-70 °C
compressors)

Working pressure: Minimum- Pack


Maximum (bar(g))
10 bar - 50 Hz 4–10

Item Reading in bar(g)


Pressure drop over air filter Below 0.044
Intercooler pressure (loaded condition) 1.7-3
Intercooler pressure (unloaded condition) (-0.65)-(-0.70)
Oil pressure (depends on climatic conditions) 1.2-4.5

11.6 Compressor data


ZR compressors

Temperature Reading
Oil Approx. 40 ˚C
Outlet of low pressure stage 120-235 °C
Outlet of high pressure stage 100-235 °C
Air outlet Approx. 25 ˚C
Inlet of cooling water Below 40 ˚C
Outlet of cooling water Below 50 ˚C

Oil quantity in the lubrication system of the compressor

Compressor type l
ZR 110, ZR 132, ZR 145 29

APF236826 183