Trigger Cable Connection - Quick Guide

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Quick Guide

ZEISS Trigger Cable Connection


ZEISS Trigger Cable Connection

Original Manual

Carl Zeiss Microscopy GmbH


Carl-Zeiss-Promenade 10
07745 Jena
Germany
microscopy@zeiss.com
www.zeiss.com/microscopy

Carl Zeiss Microscopy GmbH


Carl-Zeiss-Promenade 10
07745 Jena
Germany

Document Name: ZEISS Trigger Cable Connection Quick Guide


Revision: 1
Language: en-US
Effective from: 03/2021

© 2021 This document or any part of it must not be translated, reproduced, or transmitted in any form or by any means, elec-
tronic or mechanical, including photocopying, recording, or by any information or retrieval system. Violations will be prose-
cuted. The use of general descriptive names, registered names, trademarks, etc. in this document does not imply, even in the
absence of a specific statement, that such names are exempt from the relevant protective laws and regulations and therefore
free for general use. Software programs will fully remain the property of ZEISS. No program, documentation, or subsequent up-
grade thereof may be disclosed to any third party, unless prior written consent of ZEISS has been procured to do so, nor may be
copied or otherwise duplicated, even for the customer's internal needs, apart from a single back-up copy for safety purposes.
ZEISS reserves the right to make modifications to this document without notice.
​ Content​ ZEISS

Content
1 Introduction .................................................................................. 4

2 Description Pattern ....................................................................... 5

3 Andor iXon3 .................................................................................. 7

4 Axiocam ........................................................................................ 8

5 ORCA-Flash/Fusion ........................................................................ 9

6 pco.edge ....................................................................................... 10

7 Prime BSI/95B................................................................................ 11

Quick Guide ZEISS Trigger Cable Connection | en-US | Rev.1 3


1 Introduction​ ZEISS

1 Introduction
Welcome Welcome to the quick guide for trigger cable connection.
This guide shows you how to connect the trigger cables to the camera and the SVB (signal distri-
bution box) in order to control the camera via external trigger.
Apart from the introduction and description pattern, each chapter represents one or more camera
models and its/their connections to the SVB.

Content
Chapter Content
Description Pattern Provides information on the description pattern of the sub-
sequent chapters.

Camera Includes the name of the camera and a visual representation


of the connection.
The chapters are arranged in alphabetical order.

Quick Guide ZEISS Trigger Cable Connection | en-US | Rev.1 4


2 Description Pattern​ ZEISS

2 Description Pattern
Each chapter describes the connections between one or more camera models and the SVB by fol-
lowing these patterns:

§ The right side represents the SVB and its ports (i.e. example 1).

Signal Distribution Box = SVB

Trigger OUT

Trigger IN 1

Trigger IN 2

Fig. 1: Example 1
§ The left side represents one camera and its specific ports (i.e. example 2).

Camera Name SVB

Port 1
Trigger OUT

Port 2
Trigger IN 1
Port 3

Trigger IN 2
Port 4

Fig. 2: Example 2

Quick Guide ZEISS Trigger Cable Connection | en-US | Rev.1 5


2 Description Pattern​ ZEISS

§ If the camera needs a breakout cable, the left side represents the breakout cable and its indi-
vidual cables (i.e. example 3).

Camera Name SVB

Cable 1
Trigger OUT
Cable 2

Cable 3

Cable 4 Trigger IN 1
Cable 5

Trigger IN 2

Fig. 3: Example 3

Quick Guide ZEISS Trigger Cable Connection | en-US | Rev.1 6


3 Andor iXon3​ ZEISS

3 Andor iXon3
The following description is applicable for Andor iXon3 885 / 887 / 888 cameras.

Andor iXon3 SVB

Ext Trig
Trigger OUT

Arm
Trigger IN 1
Shutter

Trigger IN 2
Fire

Fig. 4: Andor iXon3

Quick Guide ZEISS Trigger Cable Connection | en-US | Rev.1 7


4 Axiocam​ ZEISS

4 Axiocam
The following description is applicable for these Axiocam cameras:

§ Axiocam 503 color/mono


§ Axiocam 506 color/mono
§ Axiocam 512 color/mono
§ Axiocam 702 mono
§ Axiocam 705 color/mono/pol
§ Axiocam 712 color/mono

Axiocam SVB

TRIGGER
Trigger OUT
GPO 0

GPO 1

GPO 2 Trigger IN 1
GPOPWR
AUXPWR
Trigger IN 2

Fig. 5: Axiocam

Quick Guide ZEISS Trigger Cable Connection | en-US | Rev.1 8


5 ORCA-Flash/Fusion​ ZEISS

5 ORCA-Flash/Fusion
The following description is applicable for ORCA-Flash4.0 and ORCA-Fusion cameras.

ORCA-Flash/Fusion SVB

EXT. TRIG
Trigger OUT

TIMING 1
Trigger IN 1
TIMING 2

Trigger IN 2
TIMING 3

Fig. 6: ORCA Flash/Fusion

Quick Guide ZEISS Trigger Cable Connection | en-US | Rev.1 9


6 pco.edge​ ZEISS

6 pco.edge
The following description is applicable for pco.edge cameras.

pco.edge SVB

{
1
Trigger OUT
in
2
Trigger IN 1

{
3
out
Trigger IN 2
4

Fig. 7: PCO edge

Quick Guide ZEISS Trigger Cable Connection | en-US | Rev.1 10


7 Prime BSI/95B​ ZEISS

7 Prime BSI/95B
The following description is applicable for Prime BSI/95B cameras.

Prime BSI/95B SVB

Trigger In
Trigger Ready Out Trigger OUT
Read Out
Expose Out 1
Expose Out 2 Trigger IN 1
Expose Out 3
Expose Out 4

Trigger IN 2

Fig. 8: Prime BSI/95B

Quick Guide ZEISS Trigger Cable Connection | en-US | Rev.1 11


Quick Guide ZEISS Trigger Cable Connection | en-US | Rev.1
Modifications reserved.

Carl Zeiss Microscopy GmbH phone: +49 3641 64 3161


Carl-Zeiss-Promenade 10 fax: +49 3641 64 3439
07745 Jena info.microscopy@zeiss.com
Germany www.zeiss.com/microscopy