Connection and activation


Connection and activation
MostCare connection
Up

MostCareUp is based on the analysis of the arterial blood pressure waveform.


The signal is provided to the monitor following 4 different configurations: • Analog connection
MostCareUp directly connected to the analog output of the bedside monitor via an input
/ output analog cable. By using this type of cable, there is no contact with the transducer
nor with the patient.

• Stand alone connection


MostCare Up directly linked to the transducer via a direct cable.

IN 1

Example of standard monitor

ABP

• MostCareUp transducer
A simplified transducer placed between the standard blood pressure transducer (any
brand) already in use and the patient arterial tubing, while the electrical extension is
connected to MostCare Up with a direct transducer cable (03MUEDW).

• Y-shaped connection
MostCareUp and the bedside standard monitor connected to the
transducer via a Y cable.

DS-PMS01

Exhisting
ABP
ABP blood pressure
transducer line
ABP

Example of standard monitor In order to choose the right cable for each configuration, please check the
tables in the next pages and identify the right code.
Note: For both the Direct-to-Transducer Cable and the Y-Cable, the choice of the cable depends
on the type (brand & model) of transducer in use, while for the analog connection, the choice of the
analog cable depends wholly on the brand and model of the bedside standard monitor.

2 3
Connection and activation
Direct to Transducer Cables (stand alone connection)
& Y-Cables (Y-shaped connection)

Direct Cable Code Y Cable Code Cable Picture Compatibility with Transducer Transducer's Picture Transducer's Connector

03MUYBBR
• B.BRAUN Transducer
03MUBBR
• PHILIPS Transducer
03MUYBBR1

• BD Transducer
03MUBD 03MUYBD • Argon / MeritMedical (DTXPlus® )
Transducer

• Transducer BIOSENSOR (Biotrans)


03MUBIO 03MUYBIO • Transducer UTAH MEDICAL (650-
211)

03MUDPT 03MUYDPT • CODAN PVB (BDPT) Transducer

03MUEDW 03MUYEDW • EDWARDS (TruWave) Transducer

03MUMED Not Available • MEDEX (Logical) Transducer

• MEDEX (Transtar, MX981-15)


Transducer
03MUMED2 03MUYMED2 • ICU MEDICAL (Transpac)
Transducer
• ABBOTT/HOSPIRA Transducer

4 5
Connection and activation
Input / Output Analog Cables (Analog Connection) MostCare activation Up

Flexibility of use
Endless-On Demand
Cable Code Cable Picture Cable's Connector Compatibility with Monitor

MostCareUp guarantees the maximum


flexibility and cost efficiency thanks to
MUHEMO018 the various ways in which it can be used.

• HP Philips Monitor (IBP red The On Demand version of the monitor


module needed) can be activated for a single use or for
periods of time to meet specific
application needs.
The Endless version allows an unlimited
• Dräger-Siemens Monitor use of the system without additional cost.
MUHEMO024 (i.e. Dräger Infinity Kappa)
(i.e. Siemens SC7000)

• 7 pin: Compatible with


1 use 24 hours
MUHEMO031 Datex-Ohmeda Monitor
(i.e. Dash 3000, 4000, 5000)

10 uses 30 days

50 uses 365 days


MUHEMO033 • GE –Patient Data Module
(PDM)
(i.e. Carescape-B850 or Solar 8000
monitor)

• Nihon Kohden
MUHEMO034
Monitor
Cards

04MCU1D02 MostCareUp card – 24 hours (1 day)

04MCU1M02 MostCareUp card – 30 days (1 month)

04MCU1Y02 MostCareUp card – 365 days (1 year)


• Fukuda Denshi Monitor
MUHEMO035 04MCU01U02 MostCareUp card – 1 use
(i.e. Dynascope DS-7300)
04MCU10U02 MostCareUp card – 10 uses

04MCU50U02 MostCareUp card – 50 uses

6 7
Connection and activation
Arterial Procedure Pack for
MostCareUp Activation

Vygon provides complete arterial procedure packs - Fast: Reduced preparation time
VYSET
to support the practitioners on the hemodynamic - Complete: A single pack for both catheter Content
Code
management of critically ill patients. insertion and activation of advanced hemodynamic
monitoring with Mostcare Up On Demand monitor.
1 patient activation (72h) for MostcareUp On Demand
hemodynamic monitoring

Sterile procedure pack including a leadercath polyethylene Seldinger arterial catheter

V02770139
Grip-LokTM catheter Polyethylene Arterial Outer Wrap 10 x Non-woven swabs,
fixation device leadercath PE 20G x 8cm 75x90 cm 4 ply, 7,5x7,5cm

TegadermTM Dressing Arterial peelable drape 50x100cm 5 ml LS syringe


10X12cm fenestrated 5,5x7,5cm

All the content listed above for V02770139 +


V02770202
A simplified blood pressure transducer for MostcareUp

8 9
CRITICAL CARE
9/2021 - DCMOST18478E

For further information, please contact: questions@vygon.com


The specifications shown in this leaflet are for information only
and are not, under any circumstances, of a contractual nature.

Vygon – 5, rue Adeline • 95440 ECOUEN • FRANCE