• 13.E/Rထဲက extinguisherဖတွေ
• 16.Multi- meterဘာဖတွေတိုင့်ြီးလိုရလဲ
ဲ့ ?
• 19.Centrifugal pump overhaulလို ့် ပ ြီ ြီး ဘာဖတွေစစ့် ရ လဲ။ suction လိုက့်ဘြီး ဘာဖ ကာင့်လ
ဲ့ ?ဲ
• The chemical method is basically a storage tank which collects solid material for
• The biological method treats the sewage so that it is acceptable for discharge
inshore.
• The most preferred sewage treatment in ship is biological sewage treatment i.e.,
using aerobic bacteria. So we will discuss only biological treatment plants here.
19.Centrifugal pump overhaulလို ့်ပ ြီြီး ဘာဖတွေစစ့်ရ လဲ။ suction လိုက့်ဘြီး ဘာဖ ကာငလ
ဲ့့် ?ဲ
OEW.7.04 55
It is possible for the small water or steam passages
to block with scale or dirt and the gauge will give
an incorrect reading. To check that passages are Steam Cock (A)
OEW.7.04 56
Water Gauges
Boiler gauge glass blow down
1. Close the water cock and open drain cock.
2. The boiler pressure should produce a strong jet of
steam from the drain.
3. Steam cock is now closed and water cock opened.
4. A jet of water should now pass through the drain.
5. The absence of a flow through the drain will indicate
that the passage to the open cock is blocked.
6. Then close drain cock and open water cock, water level
rise up.
7. Finally open steam cock.
-incenerator ြီးြီ ဖလာင့်ဘာactionယ လဲ
• In case of ER fire when CO2 flooding is required, this valve is opened before
evacuating ER
bunker tank ဖတွေ ROB တွေက့်ခင
ို ြီး့် ။ sounding ကဖန MT ဖ ာင့်ြီးတာလိုချင့်
-Boiler mounting, air vent cock က ဘာအတွေက့်လဲ။
Air Cock
These are fitted to the upper parts of
the boiler as required to release air
from drums and headers, either when
filling the boiler, or raising steam.
OEW.7.04 102
-FWG ဖရထွေက့်ဖကာင့်ြီးဖအာင့်ဘာလို ့်ရ လဲ။
GE overhaul, liner ာ ဘာတိုငြီး့် လဲဖ ြီး။
A cylinder liner is calibrated by measuring the internal
diameter using a micrometer gauge. It is routinely carried out
during a unit overhaul when the running gear has been
removed. So that the measurements can be directly compared
to previous readings and a wear rate calculated, the position
of the measurements is standardised by using a gauging point
template, which in practice is a piece of flat bar hung over the
side of the liner. The bar has holes drilled in it at the
appropriate gauging points. The diameter is measured both in
the fore and aft and athwartships direction.
Liner Calibration
Liner calibration is taken at every unit overhaul to know the
wear down of liner. For slow speed engine, maximum wear
down is 0.8 to 1 % of original bore diameter.
First clean liner thoroughly. Liner calibration is taken by using
inside micrometer with extension bar which has been calibrated
against a master gauge.
The measurements can be directly compared to previous
readings and a wear rate calculated, the position of the
measurements is standardised by using a gauging point
template, which in practice is a piece of flat bar hung over the
side of the liner. The bar has holes drilled in it at the
appropriate gauging points. The diameter is measured both in
the fore and aft and athwartships direction.
LINER CALIBRATION
• -Main switch board safety device, prefrential trip ာ time dealy က ဘာအတွေက့်လဲ။
• -list and heel။ rolling က list လာြီး heel လာြီး
• -Marpol annex ဘယ့်ဖလာက့်ရလဲ annex 6 ကဘာလဲ Sox ကို ဘာဖတွေန ဲ ဖလ
ဲ့ ာခ
ဲ့ ျလဲ။ % ါဖ ြီး ါတယ့်
• -Solas chapter ဘယ့်ဖလာက့်ရလဲ။
• Chapter 2.2 ဖရာက့်ဖတာ ဲ့ အဲဒါဖတွေအရ ER ာ fire fighting အတွေက့် fix installation အဖနနဲ ဘာဖတွေ
ဲ့ ရလဲ။
• -IR ဘာအတွေက့်တိုငြီး့် ။ Megga Tester နဲ AC
ဲ့ motor DC motor တိုငြီး့်
• -Battery တစ့်လိုြီးကို ဘာဖတွေ ကညဲ့့် ာ လဲ
• -12 volt battery 200ampere ရတယ့် အဲနစ့်လိုြီးကို series ဆက့်ရင့် Current ဘယ့်ဖလာက့်လဲ Voltage
ဘယ့်ဖလာက့်ထွေက့် လဲ
• -Strake ဆတ
ို ာဘာလဲ ဘယ့်လို strake ဖတွေရလဲ။
• - First start arrangement
• -work permit ဖတွေ ဘယ့်နစ့် ျ ြီးရ
• -circuit fault ဘာဖတွေရ ဘယ့်လိုတိုငြီး့် ြီြီး သ လဲ။
-Shaft earthing device ကဘာအတွေက့်ထာြီး။ ဘာဖတွေ ါလဲ။
ဖကာင့်ြီး ဖကာင့်ြီး ဘာ ကညဲ့ရ
့် င့် သ လဲ။
• A turning propeller is electrically insulated from the hull by the lubricating oil
• Electrical potential is generated between the shaft and the hull. As a result the
• Electrical potential can cause currents in the bearings resulting in pitting of the
bearing surfaces.
• Problems can be avoided if the shaft is earthed with a propeller shaft slip ring.
Gravity disc
Disc in the bowl hood for positioning the
interface between the disc stack and the outer
edge of the top disc. This disc is only used in
purifier mode.
Interface: Boundary layer between the heavy
phase (water) and the light phase (oil) in a
separator bowl.
In the purification mode, the position of the
interface (X) can be adjusted by replacing the
gravity disc (K) for one of a larger or smaller
size.
A gravity disc of a larger size will move the
interface towards the bowl periphery, whereas a
disc of a smaller size will place it closer to the
bowl centre.
The correct gravity disc is selected from a
nomogram,
Example [1]
• Specific gravity of treated oil
0.925 at15℃
• Treating temperature 70℃
• Feed rate 3000 L/h
• Selection method
1. From an intersection between
falling curve ① of specific
gravity of 0.925 and the vertical
line of 70℃, draw horizontal line
②to reach the vertical line of
100℃.
2. Connect between the right end of
line ②and the point of 3000 L/h
on the treating capacity scale
using straight line ③.
3. Read within which section of
gravity disc Inside diameter
scale the intersection made by
line ③falls.
4. For this [Example 1] select a
gravity disc having an Inside
diameter of φ79.
Specific gravity of treated oil
0.944 at50℃
Treating temperature 98℃
Feed rate 1250 L/h
Selection method
1.From an intersection between
rising curve ④ of specific gravity
of 0.944 and the vertical line of
50℃(being converted to a
specific gravity at 15℃), draw
curve ⑤along the falling curve to
reach the vertical line of 98℃,
then draw a horizontal line to
reach the vertical line of 100℃.
2. Connect between the right end of
the horizontal line and the point of
1250 L/h on the treating capacity
scale using straight line ⑥.
3. Read within which section of gravity disc Inside diameter scale the intersection made
by line ⑥falls. For this [Example 2] select a gravity disc having an Inside diameter of
φ71.5.
-Marpol annex ဘယ့်ဖလာက့်ရလဲ annex 6 ကဘာလဲ Sox ကို ဘာဖတွေန ဲ ဖလ
ဲ့ ာခ
ဲ့ ျလဲ။ % ါဖ ြီး ါတယ့်
-Solas chapter ဘယ့်ဖလာက့်ရလဲ။
Chapter 2.2 ဖရာက့်ဖတာ ဲ့ အဲဒါဖတွေအရ ER ာ fire fighting အတွေက့် fix installation အဖနနဲ ဘာဖတွေ
ဲ့ ရလဲ။
-IR ဘာအတွေက့်တိုငြီး့် ။ Megga Tester နဲ AC
ဲ့ motor DC motor တိုငြီး့်
-Battery တစ့်လိုြီးကို ဘာဖတွေ ကညဲ့ ့် ာ လဲ
-12 volt battery 200ampere ရတယ့် အဲနစ့်လိုြီးကို series ဆက့်ရင့် Current ဘယ့်ဖလာက့်လဲ Voltage
ဘယ့်ဖလာက့်ထက
ွေ ့် လဲ
-Strake ဆိုတာဘာလဲ ဘယ့်လို strake ဖတွေရလဲ။
-Main switch board safety device, prefrential trip ာ time dealy က ဘာအတွေက့်လဲ။
-list and heel။ rolling က list လာြီး heel လာြီး
- First start arrangement
-work permit ဖတွေ ဘယ့်နစ့် ျ ြီးရ
-circuit fault ဘာဖတွေရ ဘယ့်လိုတိုငြီး့် ြီြီး သ လဲ။
-Marpol annex ဘယ့်ဖလာက့်ရလဲ annex 6 ကဘာလဲ Sox ကို ဘာဖတွေန ဲ ဖလ
ဲ့ ာခ
ဲ့ ျလဲ။ % ါဖ ြီး ါတယ့်
MARPOL (73/78)
sulphur content
SOLASကဘာလဲCONVENTIONလာြီးLAWလာြီး
Solas chapter ဘယ့်ဖလာက့်ရလဲ။
Chapter 2.2 ဖရာက့်ဖတာ ဲ့ အဲဒါဖတွေအရ ER ာ fire fighting အတွေက့် fix installation အဖနနဲ ဘာဖတွေ
ဲ့ ရလဲ။
•A short-circuit is an abnormal low-resistance connection between two nodes of an electrical circuit that are meant to
be at different voltages.
•Damage form short circuits can be reduced or prevented by employing fuses, circuit breakers, or other overload
protection, which disconnect the power in reaction to excessive current.
i. Shut the air starting valve, fuel oil inlet & outlet valves and isolate the system.
j. Let lube oil priming pump run for half hour after then stop it.