NAMEP L ATE MARKIN G

Name and address of manufacturer Equipment name Serial number

EJB 5A S/N: 2017-00001


Supermec Pte Ltd
17 Tuas Ave 20 - Singapore 638828 IMQ 11 ATEX 031X Certificate Number
CE marking + Notified Body Tel +65 6861 9522 Fax +65 6861 0184
www.supermec.com
IECEx IMQ 14.0010X Additional certificate
Ex db IIB+H2 T5 Gb IP Protection Degree

0051
II 2GD IP66 Ta -20 +60 °C
ATEX marking Ex tb IIIC T100°C Db
Ambient Temperature
V max voltage
Hz rated frequency W max dissipated
Electrical parameters
V max current number terminals max wire size (mm2)
IEC/CENELEC marking Other information by used Standards
Made in SINGAPORE Use Screws Quality A2-70

E X P LO S I O N P R O O F E L E C T R I C A L E Q U I P M E N T M A R K I N G S
ATEX Gas Dust
` II 2 G D Ex db IIC T2 Gb Ex tb IIIC T250°C Db
` Ex-Proof Characteristic Marking Ex Prefix Ex Marking Ex Prefix Ex Marking

II Equipment Group db Protection Type tb Protection Type

2 Equipment Category II C Explosion Group III C Explosion Group

G Gas - Vapour - Mist T2 Temperature Class T 250°C Max Surface Temperature

D Dust Gb EPL - Equipment Protection Level Db EPL - Equipment Protection Level

T YP E OF P ROTEC TI ON
CODE Protection Method Zone Standard Protection Concept
OXYGEN EXP LOSION GROUP - - - IEC - EN 60079-0 General Requirements
da 0 -1 - 2 IEC - EN 60079-1 Contain the explosion - Prevent the flame propagation
Explosion Hazardous Typical
Group Mixture Component db Flameproof 1-2

I Mining Methane dc 2

IIA Propane eb 1-2 IEC - EN 60079-7 No arcs, sparks or hot surfaces


Increased Safety
IIB GAS Ethylene ec 2
EXPLOSION MIST
IIB + H2 VAPOR Hydrogen ia 0-1-2
Intrinsic Safety Limit the energy of the spark and the surface temperature
IIC Acetylene ib 1-2 IEC - EN 60079-11

IIIA Combustible Flyings ic 2

IIIB DUST Non-conductive Dust ic Intrinsically Safe Systems 1-2 IEC - EN 60079-25 Limit the energy of the spark and the surface temperature
FLAMMABLE IIIC Conductive Dust ic Intrinsically / N.S. Fieldbus Systems 1-2 IEC - EN 60079-27 Limit the energy of the spark and the surface temperature
SUBSTANCE IGNITION ma 0-1-2
SOURCE Encapsulation IEC - EN 60079-18 Exclusion of Explosive Atmosphere
mb 1-2
mc 2
nA Non Sparking 2 No arcs, sparks or hot surfaces
nC Enclosed Break 2 IEC - EN 60079-15 Prevent the flame propagation
nL Energy Limited
nR Restricted Breathing 2 Protection by enclosure
o Oil Filled 1-2 IEC - EN 60079-6 Exclusion of Explosive Atmosphere

E Q U IPM E N T G ROU P & C AT E G O RY


px, py 1-2
TEMP ER ATURE
Pressurized IEC - EN 60079-2 Exclusion of Explosive Atmosphere
pz 2
Equipment Hazardous Temperature Max. Surface q Powder Filled 1-2 IEC - EN 60079-5 Prevent the flame propagation
Explosive Atmosphere Presence Zone
Group Category mixture Class Temp. ia 20 - 21 - 22
I M1 T1 450°C
METHANE ib Intrinsic Safety 21 - 22 IEC - EN 61241-11 Limit the surface temperature
-- Mining T2 300°C
I M2 COAL DUST ic 22
T3 200°C
II 1G Continually - for long periods - frequently 0 ma 20 - 21 - 22 IEC - EN 60079-18 Exclusion of Ex-atmosphere
GAS T4 135°C
II 2G Occasionally under normal operations 1 T5 100°C mb Encapsulation 21 - 22 IEC - EN 60079-18 Exclusion of Ex-atmosphere
MIST
VAPOR Not expected during normal operations T6 85°C mc 22 IEC - EN 60079-18 Exclusion of Ex-atmosphere
II 3G 2
If it does occur only rarely and for a short period
pD Pressurized 21 - 22 IEC - EN 61241-4 Exclusion of Ex-atmosphere
II 1D Continually - for long periods - frequently 20
ta 20 - 21 - 22
II 2D Occasionally under normal operations 21
DUST tb Enclosed 21 - 22 IEC - EN 60079-31 Keep the combustible dust out and avoid hot surfaces
Not expected during normal operations
II 3D 22
If it does occur only rarely and for a short period tc 22

IP PROT E C T I O N DE GR E E - E N 6 0 5 2 9 A R EA C L A SSI F I C ATI ON


Protection against Solids Code Code Protection against Liquids EN 60529 NEMA 250
no protection 0 0 no protection IP 20 1
Comparison Table IP - NEMA

objects > 50 mm 1 1 vertical 90° dripping water IP 53 5


objects > 12 mm 2 2 70° to 90° dripping water IP 54 12 - 12K
objects > 2.5 mm 3 3 sprayed water up to 60° from vertical IP 54 3R - 13
objects > 1 mm 4 4 splashed water from any direction IP 55 3 - 3S
jets of water from any angle
dust protected 5 5 IP 56 4 - 4X
hose Ø 6.3 mm

dust tight 6 6
heavy jets of water from any angle
IP 67 6 ZONE 0
hose Ø 12.5 mm
ZONE 1
7 immersion to depth of 100 cm IP 68 6P
8 submersion to a specified depth over 100 cm ZONE 2

N ote: Com pa r iso n Ta b le va lu e s a re purel y indicat ive a nd dep ends by different evaluat i o n c r iter i a.

E Q U I PME NT PROT E C T I ON LE VEL


EPL Code
Definition Equipment Category
Gas Dust Mining
Ga Da Ma Very High Protection - safe after two consecutive malfunctions M1 - M2 - 1GD - 2GD - 3GD
Gb Db Mb High Protection - safe after one malfunction M2 - 2GD - 3GD
Gc Dc - Normal Protection - safe under normal operating conditions 3GD