PUMPS

AFFINITY LAWS

Initial N1 OR D1 510
New N2 OR D2 530

Initial Q1 Flow rate 405


Initial P1 Pressure 95.3
Initial HP1 power KW 125.1

New Q2 Flow rate 421


New P2 Pressure 102.9
New HP2 power KW2 140
N = PUMP RPM
D = PUMP IMPELLER DIAMETER

Q3 595
KW3 198
PIPE LINE PRESSURE DROP
AFFINITY LAWS

Initial Q1 Flow rate 120


New Q2 Flow rate 120

Initial D1 Pipe Dia 6 P2 182


New D2 Pipe Dia 4
P1 24
1.0

GPM
0.9 10000
3000
1000
500
0.8 300
200
100
0.7
50
30
0.6

0.5

0.4
10 GPM
5
0.3

0.2

0.1

500 1000 1500 2000 2500 3000


N Q
NS
H 3/4

EFFICIENCY AS A FUNCTION OF SPECIFIC SPEED AND CAPACITY