Solar PVSitesurvey V20 EPCChoice II

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Solar PV Site Survey V2.

0
Assessor name:

Signature:

Customer ID: Date:

Customer Details (installation address)


Title Property type
How many storeys is the
New build dwelling?
property?
Name Mid terrace

Address End terrace 1 2 3 4+ Yes

Semi bung No

Postcode Det bung Approx. Year property was built?

Home Tel Semi house

Mobile Tel Det house

Det Property

Flat *

* Flat, how many floors in building?

* What floor is the flat situated on?

Over shading Factor <20% 20-60% 60-80% >80%

LARGE CONCRETE TILE: e.g. SMALL SMALL CLAY/


SLATE: Natural or LARGE OLD HOLLOW CLAY
Roof Type Double Roman, Square Profile, Bold CONCRETE TILE PEG
fibre cement PANTILE
Roll, Pantile, Stonewold (150mm2) TILE(150mm2)

Tile Dimensions: If measurements can be taken from ground level Height (mm) Width (mm) Depth (mm)

Is the roof surface flat? Y/N If not, estimate how much undulation? Slight(<50mm) / Moderate(500mm-150mm) / High(>150mm)

Potential shading issues to proposed roof:

Scope of Works/Site Specifics


Site specific issues and additional access requirements.
Type of Scaffold Proposed Typical Scaffold Tower Scaffold Easy Deck

Obstructions: Conservatory Decking Large Bay Other (Specify)

Access Requirements: Good Access Narrow Access Lack of Parking Other (Specify)

Scaffold Location: Front Rear Left Hand Side Right Hand Side

Ground Condition Solid Soft Even Uneven Other (Specify)

Additional
Information:

Inverter Location (Area required of approx 1m2):- Loft Garage External Other (Specify)

Type of surface is the inverter going to be place on? Brick/Stone Block Frame Mounted Other (Specify)

Additional
Information:

DC Cable Run

Internal External DC Cable Length m

AC Cable Run

Internal External AC Cable Length m

Solar PV Installation Works Y/N Photo

Mpan Number: (this can be found on the latest utility bill)

Space on consumer unit for an extra way (This must be a spare slot with a blanking plate or a confirmed spare fuse) Yes No

Is earth bonding clearly visible by the consumer unit and on mains gas/water - Please Answer Y (Yes) or N (No) or N/V (Not Visible) E G W

Is there space within the roof space for the inverter (wall or board mounted) NO CHIMNEY MOUNT Yes No

Does client require alternative location for inverter if so supply images and dimensions of space (1m2) Yes No

Does the Inverter need to be placed on a frame? Yes No

Flat Roof/A frame mount required Yes No

Is the proposed installation attached to the property where consumer unit is located (i.e. not a detached garage) Yes No

Page 1
Internal Roof Structure Details
Visible Issues in Roof Structure, Wet/Rotten rafters, Broken rafters, Alteration work etc:

Draw sketch cross section of roof here

The below Template has been given to help assist you. In some cases it may not represent the cross section of this particular property in this instance
produce you own Cross Section on Page 4. Please ensure if the cross section is showing a Typical Cut Roof, That you also show measurements 'D' & 'E'
on the diagram. If a Dormer is present add this to the diagram with the measurement shown.
What is the roof construction? Actual Roof Pitch ⁰ (Internal) Timber Dimensions
Traditional Cut Roof (Purlin Roof) PV Roof 1 PV Roof 2 PV Roof 3 Size of Rafter: Width mm Depth mm

Prefabricated Truss (Trussed Rafter) Rafter Spacing, (distance between rafters): mm

Other (Please specify) Size of Purlin: Width mm Depth mm

Maximum Distance between Purlin supports: (If Applicable) mm

(Internal) Distance from Ridge


to Purlin (D)
(If applicable)
(Internal) Total
Length of Rafter: M
(A)

(Internal) Joist to
M
Ridge (C) (Internal) Distance From Purlin
to Wall Plate: (E)
(If Applicable)
M
M

(Internal) Total Span of roof:


(B)

Notes

Page 2
Roof Layout - Measurements Must be External measurement
Using the template below indicate the roof dimensions of the proposed roof (Birdseye View Diagram), Measurements of any roof obstructions must be
noted on the diagram as these may effect the proposed layout. Indicate the proposed layout of the panels on the diagram, Showing the panels in either
Portrait or Landscape layout indicating the amount that will fit on the usable roof space. (Ensure there is a 500mm gap to the edge of the roof on all sides)
If Panel size is not provided consider each individual panel to measure 1014mm x 1662mm (This dimension takes into account the space between each
panels) If more than 1 PV roof duplicate this page.
The below has been given to help assist you. In some cases it may not represent the actual roof. In this case use page 4 to produce your own.
PV Panel Chimney Velux Window Area affected by Shading Soil Vent Pipe Roof Tile Vent

(External) Length of available roof


space at Ridge: (B)

(External) Eaves to ridge (External) Eaves to ridge


Left hand side (D) Right hand side (D)

M M

(External) Length of available roof


space at Eaves: (A)

M Individual Panel size

Length: mm

Width: mm

(External) Height of Roof:


(G)

M PV
(External) Height of the
ridge from the ground:
(F)
(External) Height of
M gutter from ground: (H)

Proposed Roof Layout Orientation

(External)Span of
roof: (E)

No. Of panels

Actual Degrees 0 of Property


What style of Roof is it? (Tick all that apply)
Which PV roof is the above diagram for?
Gable Hip Double Hip Flat Mansard

Other (Please specify) PV Roof 1 PV Roof 2 PV Roof 3



Photograph Check List
Main House Front Existing Consumer Unit Close up of Tile/Slate Type
Main house Back Electric Meter position Aerial View via Google or Bing
Proposed Roof Electric Meter equipment Cheque Payment (if applicable)
Internal Roof Structure Main Equipment Bonding Any Other Issues
Inverter Location Scaffolding Site
Property Access Points Loft Access
Page 3
Additional Information
PV Panel Chimney Velux Window Area affected by Shading Soil Vent Pipe Roof Tile Vent

Page 4