Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

CEDI Performance Projection

File Name:ICA FLUOR

System Summary
Product Flow Rate 300 m³/h
Module Type VNX-Max-1
Number of Modules 14
Flow per Module 21.4 m³/h
Feedwater Conductivity @ 25°C 1.17 µS/cm
Feed water Conductivity Equivalent, including COЇ 23.97 µS/cm
Total Exchangeable Anions (TEA) 16.6 ppm as CaCOЈ
Maximum System Recovery 95 %
Product Water Resistivity ϭϮ͘ϰDёͲĐŵ
Product Water Conductivity 0.081 µS/cm
Salt Rejection 99.7 %
Pressure Drop 53.71 psid
Total Hardness(ppm as CaCOЈͿ 0
Water Analysis
Inlet Outlet Concentrate
Species
(ppm as ion) (ppb as ion) (ppm as ion)
NHЉ
K 0.002 <1.0 0.04
Na 0.247 <1.0 4.94
Mg
Ca
Sr
Ba
Fe
Cu
Al
Mn
COЈ
HCOЈ 0.472 1.594436 9.44
NOЈ 0.027 <1.0 0.54
Cl 0.086 <1.0 1.72
F
SOЉ 0.009 <1.0 0.18
B
SiOЇ 0.016 2.154 0.32
COЇ 8.16 27.56482 163.2
pH 4.94 NA
Calc pH 4.92 NA
Temp °C 32

IP-PRO v 4.5 12/03/2022


Total Feed Total Reject Total Product
315.8 m³/h
15.79 m³/h 300 m³/h

1.17 µS/cm ϭϮ͘ϰDёͲĐŵ

23.97 µS/cm FCE 0.081 µS/cm

0.016 ppm as SiOЇ

8.16 ppm as COЇ

32 °C

This projection is an estimate of performance and not a guarantee. The outputs from this program
are a guide only and are not a guarantee of performance, pressure drop, voltage or current.
Performance may vary when operating above module nominal flow rate and/or high ionic
challenge applications, or at the extremes of the permitted feed water temperature. Please
consult IONPURE sales and technical support for verification of data.

Estimated Power Requirements


AC Power Consumption 1.69 kW/module
Total AC Power Consumption 567.29 kWh/day (24/7 operation)
DC Energy Consumption 0.28 kWh/kgal
DC Energy Consumption 0.07 kWh/m³
DC Voltage 336 V
Start-up DC Current 4.7 A
* Assumes 93% efficiency of AC to DC power controller

* IONPURE recommends the use of the DC3 power supply IP-DC3PH600V-M1 (W2T827150) with IONPURE CEDI modules.

IP-PRO v 4.5 12/03/2022

You might also like