100mm min
flashing based roofing underlay (underlay to Selected type cladding as per plans
150mm
JSC Vertical Shiplap FIRST FLOOR
to the shingle weathering strip Roof framing members I.E. Rafters /
Provide continuous Weatherboard
(May vary depending on Trusses as per plans
support to flashing Internal wall lining
upstand shingle profile)
Building wrap As per JSC Vertical
For aesthetic purposes, shingle
Provide solid nogging E2/AS1 Table 23 Shiplap
to be fixed over apron flashing
between trusses / rafters with 'Holdfast Blackjack' roof Weatherboard
CCA Treated
to allow for fixing of cement as per manufacturers JSC-H-20x45 H3.2 timber APRON FLASHING DETAIL
substrate and shingles specs cavity batten, Horizontal 4
'GAF' Asphalt shingles fixed to Scale- 1:5
Rafters / Trusses @ 480mm Max centers
substrate with stainless steel or Base board to finish 50mm
as per plans HDG clouts and 'Holdfast min below floor joist
Skirting board
Blackjack' Roof Cement 75mm annular grooved
rose head, silicone
bronze or stainless steel
D226+ roofing underlay over
PBS Cavity Closer with Vent CANTILEVER DETAIL- VERTICAL &
15mm Ecoply plywood
Note: Box vent or other approved
substrate slots HORIZONTAL WEATHERBOARD
cavity vent may be used.
3
10-15° Mitre Scale - 1:5
Soffit GROUND FLOOR
Packing cut to suit 1.
APRON FLASHING DETAIL 1 - TIMBER WEATHERBOARD Jenkin A-lign bevelback
®
35mm
35mm above roof surface
25
50
Garage FFL
APRON FLASHING DETAIL 2 -
2
TIMBER WEATHERBOARD Scale- 1:10
Concrete Floor Slab
NOTE :
* All details should read in conjunction with manufacturer's specification, installation manual & Branz Appraisal 5 GARAGE DOOR ENTRY DETAIL 6 APRON FLASHING - DETAIL
* Read in conjunction with Building Code E2/AS1 for code compliance requirement. Scale 1 : 10 Scale NTS " @ 2018 Copyright EMACS Group"
TITLE : PROJECT : DRAWN BY : SCALE : REVISION : REVISION DATE : DESCRIPTION :
EMACS GROUP S.B
Engineering Architecture PROPOSED DWELLINGS AT As Above@A3
P O Box 67-026 CONSTRUCTION DETAILS-1 CHECKED BY : DATE :
Mt. Eden, Auckland
Fax : 09-6307126 CLIENT :
84 WHITNEY STREET, R. R. 23.09.2021
Planning Surveying Phone : 09-6307125 RKD DEVELOPMENT LIMITED BLOCKHOUSE BAY DP : LOT :
Email : emacs@emacsltd.co.nz
LOT 1-3 DP 49665 40 PROJECT NO : EMCS202204 SHEET NO : D 01
20mm min
Jenkin A-lign ®
Jenkin A-lign bevelback
®
Jenkin A-lign bevelback
®
10mm
lining Internal lining Wall underlay turned into
Wall plate to overhang slab edge framing reveals and taped jamb flashing. Allow to
DPC
by 6mm minimum (optional) at corners return flashing to suit
10mm min
5mm gap to weatherboard weatherboard depth
Jenkin A-lign bevelback base
®
Continuous vertical
board 20mm H3.1 jamb optional
Quickflash Code 06 cavity closer packer to end of sill tray Jenkin A-lign pre-cut
® Alternate Option
Air seal over 36 x 18mm scriber extending
backing rod JSC Vertical Shiplap
Base board to finish 50mm min to underside of head facing Building wrap As per
Weatherboard
below floor level (and 175mm (window head) E2/AS1 Table 23
7.5mm
20mm min
CCA Treated JSC-H-20x45
15mm
10mm
Architrave or
floor slab 10mm min flange cover to SC-V-20x45 H3.2 timber centers
slimline detail
225mm from slab surface to weatherboard cavity batten, Vertical @ 18mm Scriber sealed to
10
BASE OF WALL - WEATHERBOARD Packing and window 480mm Max centers
10mm min
natural ground (150mm to paving) Line of head flashing Weatherboard
1 Scale 1 : 5 support brackets as extending to outer edge Continuous air seal to
Aluminium joinery profile, Sealant
required of jamb facings perimeter of opening
flange to provide 10mm Compressible foam tape seal
Packing and min cover to 150mm long sill tray Building Wrap and
Front edge of window head Line of head flashing above
window support weatherboard extending under jamb flexible flashing tape
brackets as required over building wrap P/C aluminium joinery
packer to trimming studs
Packing cut to suit indicative profile
Architrave or
slimline detail WINDOW JAMB DETAIL - WEATHERBOARD DOOR & WINDOW JAMB DETAIL -VERTICAL WEATHERBOARD
4 Wall underlay turned into framing 6
Scale 1 : 5 reveal, flexible flashing tape at
Scale -1:5
7.5 - 10mm Jenkin A-lign pre-cut 36
®
corners
x 18mm scriber
Jenkin A-lign cavity batten
®
Wall underlay flap lapped over
Air seal over Wall underlay turned into flashing
backing rod framing reveals, flexible 50mm min cladding cover
Jenkin A-lign ® flashing tape to sill to flashing upstand(75mm) Jenkin A-lign bevelback
®
.
10mm min cover form stop end
when appropriate, ensure
cavity construction is not Head flashing by joinery manufacturer
P/C aluminium joinery 7.5mm
compromised
10mmmm
indicative profile with 15° slope and 20mm stop-end to JSC Vertical Shiplap
5mm
Architrave or
min
min
Continuous air seal to extend 20mm min beyond outer edge Building wrap Weatherboard
perimeter of opening grooved liner As per E2/AS1 Table 23
75mm annular grooved of jamb, facing or scriber CCA Treated JSC-H-20x45
to flashing
Sill support bar rose head, silicone Temporary packers if Aluminium joinery profile H3.2 timber cavity batten,
Flashing tape over head
10mm
10mm
Gib board Scale 1 : 5 15° drip edge to
centers stainless steel
Building wrap claddingContinuous air seal to
JSC Vertical Shiplap Proprietary prefolded
As per E2/AS1
10mm
Weatherboard perimeter of opening head flashing with 15° fall
Table 23
Building Wrap and flexible Line of Jamb scriber
WINDOW SILL DETAIL -VERTICAL WEATHERBOARD flashing tape over building wrap
3 P/C aluminium joinery
Scale -1:5 Stop end at head flashing indicative profile
NOTE : Head flashing turned up to
* All details should read in conjunction with manufacturer's specification, installation manual & Branz Appraisal form stop end
* Read in conjunction with Building Code E2/AS1 for code compliance requirement. Head " @ 2018 Copyright EMACS Group"
TITLE : PROJECT : DRAWN BY : SCALE : REVISION : REVISION DATE : DESCRIPTION :
EMACS GROUP S.B
Engineering Architecture PROPOSED DWELLINGS AT As Above@A3
P O Box 67-026 CONSTRUCTION DETAILS-2 CHECKED BY : DATE :
Mt. Eden, Auckland
Fax : 09-6307126 CLIENT :
84 WHITNEY STREET, R. R. 23.09.2021
Planning Surveying Phone : 09-6307125 RKD DEVELOPMENT LIMITED BLOCKHOUSE BAY DP : LOT :
Email : emacs@emacsltd.co.nz
LOT 1-3 DP 49665 40 PROJECT NO : EMCS202204 SHEET NO : D 02
Vertical Shiplap weatherboard
Weatherboard
Stud Horizontal castellated
Flashing tape Jenkin A-lign bevelback
®
cavity batten at 480 max Scriber cut to suit
Building underlay
Cavity batten weatherboard Building wrap centres
Jenkin A-lign cavity batten
®
As per E2/AS1 Table 23
Cavity closer Flashing to give 50mm
75mm min flashing upstand min cladding cover ref Packing to suit
Alu. head flashing Cavity batten E2/AS1 Table 7 for 12mm gap between claddings
Building wrap extra high wind zones
A-lign 90 x 18mm grooved facing
®
75mm annular grooved rose head, Continuous air seal Jenkin A-lign bevelback
®
Cavity batten
75mm annular grooved rose head, Flexible flashing closure with 15mm drip edge
Bevelback weatherboard silicone bronze or stainless steel to weatherboard
tape in corners
SCARF JOINTING DETAIL - Scriber Internal wall lining
JSC Vertical Shiplap Weatherboard 7.5mm gap Al Head flashing with stopends;
2 VERTICAL WEATHERBOARD 15 º fall; 35mm min. lap to
Building wrap air seal
Scale -1:5 weatherboard & 10mm lap to
HINGED DOOR JAMB- WEATHERBOARD As per E2/AS1 Table 23
6 Lintel L8 door jamb
Packing and window Scale 1 : 5 SOFFIT DETAIL -VERTICAL WEATHERBOARD
support brackets as 9 Timber garage door liner
required Scale -1:5
GARAGE DOOR HEAD DETAIL -
Continuous air seal 10
Line of interior finished WEATHERBOARD Scale- 1:5 D226+ roofing underlay over
Sill support bar 15mm plywood substrate
floor level 'GAF' Asphalt shingle roofing
Concrete slab floor Unpaved Continuous bead of 'Holdfast
ground laid in strict accordance with
bottom of exterior Blackjack'
20mm set down manufacturers specifications
cladding roof cement on flashing, starter
at garage door course
and concealed part of shingle
3 HINGED DOOR SILL DETAIL - WEATHERBOARD
for all wind zones
Scale 1 : 5 ramp down GAF 'Starter course' over drip
Water resistant 'Air Seal'
to perimeter of trim cavity edge flashing
Metal kickout drip edge flashing
PF rod Paved driveway with 76mm return, downturn
Flexible flashing tape cover to comply with NZBC E2
in corners 25mm min. clearance requirements, 50mm low and
Wall underlay between bottom of cladding medium wind zones & 70mm to
dressed into opening and driveway at garage high and very high wind zones
door opening with 10mm kickout
Jenkin A-lign bevelback
®
.
weatherboards with Scribers GARAGE RAMP DETAIL Shingle to overhang flashing by
7
Cavity Batten . to suit profile Scale- NTS 10mm
20mm min. extension Line of head flashing above Soffit lining as per plans Barge board as per plans
NOTE :
to head flashing 10mm min. cover * All details should read in conjunction with manufacturer's specification, installation
GARAGE DOOR JAMB DETAIL - manual & Branz Appraisal BARGE FLASHING DETAIL
4 * Read in conjunction with Building Code E2/AS1 for code compliance requirement. 11
WEATHERBOARD Scale- 1:5 Scale 1 : 10 " @ 2018 Copyright EMACS Group"
TITLE : PROJECT : DRAWN BY : SCALE : REVISION : REVISION DATE : DESCRIPTION :
EMACS GROUP S.B
Engineering Architecture P O Box 67-026 CONSTRUCTION DETAILS-3 PROPOSED DWELLINGS AT As Above@A3
CHECKED BY : DATE :
Mt. Eden, Auckland
Fax : 09-6307126 CLIENT :
84 WHITNEY STREET, R. R. 23.09.2021
Planning Surveying Phone : 09-6307125 RKD DEVELOPMENT LIMITED BLOCKHOUSE BAY DP : LOT :
Email : emacs@emacsltd.co.nz
LOT 1-3 DP 49665 40 PROJECT NO : EMCS202204 SHEET NO : D 03
Ridge shingle fixed over ventilation
Leave min 30mm ventilation
capping with 'Holdfast Blackjack' roof
cement as per manufacturers specs gap in substrate to apex of
ridge
GAF Cobra ventilation
Provide solid nogging
sytem on ridge. Fix with
between trusses / rafters Lay shingles across Valley
clouts to substrate
60mm down from apex to from smaller roof to larger
allow for fixing of substrate D226+ roofing underlay laid
and shingles over 15mm construction
D226+ roofing underlay over plywood substrate
GAF asphalt shingles fixed
to substrate with stainless plywood substrate
steel or HDG clouts Trim shingles to form clean
15mm Ecoply plywood lines
substrate or similer, F11 or
better Stainless steel or HDG
Fascia board with clouts to fix GAF shingles to
gutter as per plans roof in accordance with
manufacturers specifications
Center line
Air flow
of valley
Overlapping shingles to be
no closer than 50mm to
centre line of valley
Timber rafters / trusses
RIDGE DETAIL - SHINGLES TILES VALLEY DETAIL- SHINGLES TILES
1 3
Scale 1 : 10 D-226+ roofing underlay over Scale- 1:10
15mm plywood substrate to be
laid so as to extend over drip
edge toward gutter Plywood to terminate between truss end and outside
face of fascia, Plywood should not extend past outside
face of fascia. H3 plywood gutter strip not required. Drip D-226+ roofing underlay
edge flashing to hang into gutter over 15mm plywood Plywood to terminate
substrate to be laid so as to between truss end and
Shingles to have min 5mm overhang to gutter extend over drip edge outside face of fascia,
Air flow
Drip edge flashing with min 90mm return and toward gutter Plywood should not extend
20mm face with 10mm kick out
10mm
10mm
'GAF' shingles roofing laid in strict
accordance with manufacturers Selected gutter
D226+ roofing underlay specifications End shingle to be turned over flashing
76mm MIN
over 15mm Ecoply plywood with min 10mm overhnag and fixed
substrate with Roofing cement
Metal kickout drip edge flashing with 76mm
15mm untreated
return, downturn cover to comply with NZBC Selected fascia board
plywood substrate
E2 requirements, 50mm low and medium
Rafters / Trusses as wind zones & 70mm to high and very high Jenkin A-lign 42x18mm eaves mould with
per plans VARIES wind zones with 10mm kickout weathergroove -fit tight to soffit lining Note: 10mm gap between
Barge board substrate and fascia to allow
Timber stud framing Selected soffit lining Jenkin A-lign weatherboard for ventilation
Selected cladding as per plans 90mm Timber framing
NOTE : BARGE DETAIL - SHINGLES ROOFING 10mm GIB board
* All details should read in conjunction with 4 Thermakraft Building wrap
manufacturer's specification, installation manual & Branz Appraisal Scale 1 : 10 EAVE DETAIL - SHINGLES ROOFING & WEATHERBOARD
* Read in conjunction with Building Code E2/AS1 for code compliance requirement.
5
Scale 1 : 5 " @ 2018 Copyright EMACS Group"
TITLE : PROJECT : DRAWN BY : SCALE : REVISION : REVISION DATE : DESCRIPTION :
EMACS GROUP S.B
Engineering Architecture P O Box 67-026 CONSTRUCTION DETAILS-4 PROPOSED DWELLINGS AT As Above@A3
CHECKED BY : DATE :
Mt. Eden, Auckland
Fax : 09-6307126 CLIENT :
84 WHITNEY STREET, R. R. 23.09.2021
Planning Surveying Phone : 09-6307125 RKD DEVELOPMENT LIMITED BLOCKHOUSE BAY DP : LOT :
Email : emacs@emacsltd.co.nz
LOT 1-3 DP 49665 40 PROJECT NO : EMCS202204 SHEET NO : D 04
Timber fillet backing Optional soaker (dashed) or
to suit, fixed over sealant to
Thermakraft underlay Jenkin A-lign weatherboard backflashing to mitre with tight
mitred corner Thermakraft building wrap
Jenkin A-lign cavity batten continuous around corner
Flange to protect
Jenkin A-lign tilting fillet sealant from exposure Jenkin A-lign bevelback
®
10mm
placement and sizing Flashing to be fixed under rose head, silicone bronze 75mm annular grooved rose head,
the asphalt shingles. Fold or stainless steel silicone bronze or stainless steel DPC
top edge to form min Raft floor slab.
Lead, aluminium or Minimum 65x65mm corner Base board to finish 50mm
10mm anti-capillary hem JSC Vertical Shiplap
stainless steel EPDM flashing hem edge folds min below floor level
flashing around pipe Weatherboard Min. 150mm to paved ground
Continuous bead of 'Holdfast compatibility to comply with
penetration 50mm min.
Blackjack' roof cement on NZBC E2/AS1 and 225mm to unsealed ground
.
flashing
JSC J42 external from edge
and concealed half of shingle 4.0gx100mm stainless steel FGL (paved)
timber corner moulding
or silicone bronze Rose
Fold edges of the boot flashing 10mm Head annular groove fixing
Flashing to be laid so back onto itself to create a
as to discharge water secondary water barrier
5 EXTERNAL CORNER DETAIL - VERTICAL WEATHERBOARD
over lower shingles
cavity batten at 480 max centres flashing hem edge folds Horizontal @ 480mm Max
A-lign pre-cut 36 x 18mm scriber
®
compatibility to comply with centers
Scriber cut to suit
NZBC E2/AS1 Building wrap
Jenkin A-lign bb weatherboard JSC Vertical Shiplap As per E2/AS1 Table 23
Weatherboard Wall underlay continuous
Quickflash code 40
back flashing 65mm 6 INTERNAL CORNER DETAIL - VERTICAL WEATHERBOARD around corner
min. cladding cover Scale
NOTE 1
: :5
Vertical Shiplap weatherboard
* All details should read in conjunction with manufacturer's specification, installation
INTERNAL CORNER DETAIL - VERTICAL & HORIZONTAL WEATHERBOARD manual & Branz Appraisal EXTERNAL CORNER DETAIL - VERTICAL & HORIZONTAL WEATHERBOARD
3 9
Scale 1 : 5 * Read in conjunction with Building Code E2/AS1 for code compliance requirement. Scale 1 : 5 " @ 2018 Copyright EMACS Group"
TITLE : PROJECT : DRAWN BY : SCALE : REVISION : REVISION DATE : DESCRIPTION :
EMACS GROUP S.B
Engineering Architecture P O Box 67-026 CONSTRUCTION DETAILS-5 PROPOSED DWELLINGS AT As Above@A3
CHECKED BY : DATE :
Mt. Eden, Auckland
Fax : 09-6307126 CLIENT :
84 WHITNEY STREET, R. R. 23.09.2021
Planning Surveying Phone : 09-6307125 RKD DEVELOPMENT LIMITED BLOCKHOUSE BAY DP : LOT :
Email : emacs@emacsltd.co.nz
LOT 1-3 DP 49665 40 PROJECT NO : EMCS202204 SHEET NO : D 05
UPPER FLOOR
JSC Vertical Shiplap FIRST FLOOR
Tread (280) Weatherboard
Ply wood sub floor Internal wall lining
Jenkin A-lign® 240x45 Floor Joist
Building wrap As per JSC Vertical
bevelback E2/AS1 Table 23 Shiplap
weatherboard CCA Treated
Weatherboard
JSC-H-20x45 H3.2 timber
H1.2 SG 8 cavity batten, Horizontal
240x45 Floor joist Blocking
@ 480mm Max centers
Rise (181)
Hanger Soffit
Skirting board Base board to finish 50mm
Stair stringers 75mm annular grooved min below floor joist
Base board to finish
50mm min below floor Soffit lining Selected scotia mould rose head, silicone
bronze or stainless steel Selected scotia mould
joist
PBS Cavity Closer with Vent
2 TYPICAL STAIRCASE DETAIL- TOP slots
CCA Treated JSC-H-20x45 H3.2 Scale 1 : 10 10-15° Mitre
CCA Treated JSC-H-20x45 H3.2
timber cavity batten, Horizontal @ LOWER FLOOR
timber cavity batten, Horizontal @ GROUND FLOOR
480mm Max centers
75mm annular grooved rose head, 480mm Max centers
75mm annular grooved rose head,
silicone bronze or stainless steel
silicone bronze or stainless steel
JSC Vertical Shiplap Weatherboard
JSC Vertical Shiplap Weatherboard
Building wrap
Building wrap
As per E2/AS1 Table 23
As per E2/AS1 Table 23
1 CANTILEVER DETAIL - VERTICAL WB (Below)
HORIZONTAL WB (Above) Scale 1 : 5 7 CANTILEVER DETAIL - VERTICAL WEATHERBOARD
Scale 1 : 5
50 50
max.190mm
Riser height
Stainless steel plate 4 TYPICAL STAIRCASE DETAIL- BOTTOM
Scale 1 : 10
Face of wall Tread Projection
max. 100mm
JSC Vertical Shiplap
HANDRAIL DETAIL Weatherboard Pitch 37° max. 15mm min., 25mm max.
gap
3 Building wrap As per
Scale 1 : 5 E2/AS1 Table 23
.
Support Pipe with a nog under 180 PFC designed by engineer
Gib board StrongTie TA Staircase Angle -
& a screw fixed strap over CCA Treated JSC-H-20x45 316 Stainless Steel: TA9SS
Flashing tape over head
to flashing
Interior wall lining H3.2 timber cavity batten,
As per E2/AS1 Table 23 flashing with PBS Butyl tape
Horizontal @ 480mm Max
PBS Cavity Closer with centers
CCA Treated Vent 240x45 SG8 H3.2 treated
75mm annular grooved rose timber stringer
10mm
20mm min
CCA Treated JSC-H-20x45
Gib board E2/AS1 Table 23 Weatherboard
Jenkin A-lign bb weatherboard H3.2 timber cavity batten,
CCA Treated Gib board CCA Treated JSC-H-20x45
Horizontal @ 480mm Max
10
480mm Max centers
10mm min
Turn up flashing tape Weatherboard PBS Cavity Closer with
100mm at trimmer studs Continuous air seal to Sealant Vent 75mm annular grooved rose
perimeter of opening head, silicone bronze or
10mm
Compressible foam tape seal slots positioned to give 15°
PF rod Building Wrap and drip edge to cladding stainless steel
Line of head flashing above Continuous air seal to
Water resistant 'Air Seal' flexible flashing tape Proprietary prefolded
P/C aluminium joinery perimeter of opening
10mm
Timber Liner over building wrap head flashing with 15° fall
to perimeter of trim cavity indicative profile
Optional Building Wrap and flexible Line of Jamb scriber
flashing tape over building wrap
Min. 100mm to paved
ground and 150mm to
4 SLIDING DOOR JAMB DETAIL- VERTICAL WEATHERBOARD Stop end at head flashing indicative profile
Scale 1 : 5 Head flashing turned up to
WANZ Support Flat packers
form stop end
Bar to support unit
GL 5 SLIDING DOOR HEAD DETAIL- VERTICAL WEATHERBOARD
Scale 1 : 5
Suitable Sill
Membrane
2 SLIDING DOOR SILL DETAIL
Scale 1 : 5 UPPER FLOOR
Jenkin A-lign ®
bevelback
Jenkin A-lign bevelback weatherboard,
®
weatherboard
Tilting fillet where
50mm cladding cover to head flashing
required for support H1.2 SG 8
upstand, 15mm drip edge to cavity closure
75mm min. flashing upstand Quickflash 06 cavity closure 240x45 Floor joist
lintel, refer to Base board to finish 50mm
Optional Jenkin A-lign ®
PF rod
bottom edge
Soffit lining
Head flashing by joinery 5mm min
manufacturer with 15° Water resistant 'Air Seal'
slope and 20mm stop-end to perimeter of trim cavity
to extend 20mm min Packing cut to suit
Temporary packer LOWER FLOOR
beyond outer edge of jamb,
facing or scriber to support unit during installation
Jenkin A-lign bevelback
®
Jenkin A-lign ®
Timber framing
5-10mm Acrylic liner over Step Wise flashing- Grey
unsealed GIB is back flashing, red Building Paper
Aqualined saddle flashing next and 2 below
Cavity battens
green on top Internal Corner flashing in
Silicone sealant green above red saddle
Proprietary shower tray flashing to cover corners
installed to Saddle flashing in red below
manufacturer's GIB Aqualined internal corner flashing in
recommendations GIB Aqualined
green and over back flashing
Silicone sealant in.
in grey to cover the junction 30m
mm .
Silicone sealant
Silicone sealant GIBd GoldlinefL Trim
upstand
.
Quickflash Code 06 cavity
3 Barge board closure
Barge board
Thermakraft underlay Jenkin A-lign tilting fillet
®
Depth of
2 15mm drip edge
.
Exterior cladding- Timber
Weatherboard 10mm min.
cavity batten .
.
Air seal all around
m 50m
30m . mi m
n n.
mi
110mm upstand
1 Vent external cover
apron flashing over the SADDLE FLASHING
.
min.1000mm high
in.
Roof Anchor Balustrade system - Residential typical fixing)
green back flashing to cover
Barge Tile
timber frame framing
above saddle 53mm wide lumberlok
flashings 12mm thick
Corner flashing in green Eave sofit toughened glass - multibrace stainless steel
above grey flashing and Barge board lining residential straps to Top and Bottom of
below barge tile joists. 6x45x3.3mm annular
SADDLE FLASHING DETAIL AT BARGE grooved nails to each end of
1 straps, Top and Bottom
Scale- 1:10 Downpipe 20mm Particle board
50mm
flooring
T Junction
Holes half the Hidden Fix disc shown.
diameter of the Floor Joist
downpipe
Double
boundary Nails, 20 off -
M10 SS Treaded Rod 90x3.4mm Ø
with 2/50mmØ x 0.8 joist
through joists
fibre washer, Nylon
bush, M10 x30 Grub
50mm
screw , front and rear Important Notes :
600mm min spacer disc * A Design engineer must ensure
Notes:
the structure can support the
1. Hole positions to avoid joints in roofing.
10mm GIB appropriate loads
2. Hole positions to discharge into pans of tile.
* All fixings must be stainless steel
3. When downpipe is located in a corner, spreaderis to be "L" shaped.
4. 600mm min spreader discharge pipe length.
5. For rectangular (or other profile) downpipes use the same design
principle as shown. Timber wall framing
6. Underlay must be installed below spreader from under apron to gutter
line across at least 300mm from edge of spreader to the next GLASS BALUSTRADE DETAIL
truss/rafter. 5
Scale- 1:5
7. Block ends of pipes.
DOWN PIPE SPREADER DETAIL NOTE :
TYPICAL SUMP DETAIL 4 * All details should read in conjunction with manufacturer's specification, installation manual & Branz Appraisal
3 Scale- 1:10 * Read in conjunction with Building Code E2/AS1 for code compliance requirement. " @ 2018 Copyright EMACS Group"
TITLE : PROJECT : DRAWN BY : SCALE : REVISION : REVISION DATE : DESCRIPTION :
EMACS GROUP S.B
Engineering Architecture PROPOSED DWELLINGS AT As Above@A3
P O Box 67-026 CONSTRUCTION DETAILS- 11 CHECKED BY : DATE :
Mt. Eden, Auckland
Fax : 09-6307126 CLIENT :
84 WHITNEY STREET, R. R. 23.09.2021
Planning Surveying Phone : 09-6307125 RKD DEVELOPMENT LIMITED BLOCKHOUSE BAY DP : LOT :
Email : emacs@emacsltd.co.nz
LOT 1-3 DP 49665 40 PROJECT NO : EMCS202204 SHEET NO : D 11
Wall corner
110mm upstand
Corner back flashing Fa 150mm min. cover,
below cladding ll
dresses into pan
50mm min
.
hem to 3 edges Tapered stopend to
upstand divert apron flashing
.
water into gutter
Saddle Flashing
Barge board
m Corner Saddle Flashing
detail B 0m
15 at corner of wall and barge board
Depth of
.
(Looked
to continue below apron flashing
from other
on the roof
Side)
Barge Board
CORNER SADDLE Barge tile/flashing to turn to
FLASHING DETAIL finish over roofing
Gerald Metal Tiles
Roofing
Saddle flashing Internal corner
over barge tile to flashing between
barge tile
cover junction barge board and
between timber timber frame GUTTER WALL JUNCTION DETAIL -
frame and barge 1
SHINGLES ROOFING Scale 1 : 10
Internal corner Gutter
flashing between
barge board and
timber frame below Jenkin A-lign cavity batten ® Wall underlay flap, lapped over
CORNER SADDLE the saddle flashing head flashing upstand
FLASHING DETAIL B Quickflash code 06
cavity closure with
15mm drip edge Jenkin A-lign tilting fillet where
®
50mm
Airseal over backing rod
Meter box
.
m min
50m Wall underlay
SADDLE FLASHING DETAIL AT FIRST 138 x 32mm H3.2 Premium
Radiata Griptread Decking Timber
150 max
FLOOR DECK AND WALL JUNCTION
1 12 mm gap
Scale: NTS
S.S. CPC40 on
both sides
2/M12 S.S Bolts with
50x5mm washers 50x3mm thick
EPDM washer
157
240x45mm SG8 H3.2 Floor Joist 240x45 SG8 @450c/c
6kN Strap treated Deck Joist @ M12 Stainless steel
top & bottom bolt @800cts Wall underlay
400mm crs.
Timber cavity batten
125x125 H5 Timber post Stringer
150mm (H) H3.2 6kN Sheet brace both sides each
timber packerat bolt wall stud to double boundary joist
fixing (cut to suit)
EXTERNAL DECK & TIMBER BALUSTRADE DETAIL AT
UPPER FLOOR DECK
2
Scale -1:10
NOTE :
* All details should read in conjunction with manufacturer's specification, installation manual & Branz Appraisal
* Read in conjunction with Building Code E2/AS1 for code compliance requirement. " @ 2018 Copyright EMACS Group"
TITLE : PROJECT : DRAWN BY : SCALE : REVISION : REVISION DATE : DESCRIPTION :
EMACS GROUP S.B
Engineering Architecture P O Box 67-026 CONSTRUCTION DETAILS- 13 PROPOSED DWELLINGS AT As Above@A3
CHECKED BY : DATE :
Mt. Eden, Auckland
Fax : 09-6307126 CLIENT :
84 WHITNEY STREET, R. R. 23.09.2021
Planning Surveying Phone : 09-6307125 RKD DEVELOPMENT LIMITED BLOCKHOUSE BAY DP : LOT :
Email : emacs@emacsltd.co.nz
LOT 1-3 DP 49665 40 PROJECT NO : EMCS202204 SHEET NO : D 13
Timber Rebated block
strapping Pre finished metal roofing
15-20mm brick slips glued over roof underlay
Masonry Block
directly to the surface of
Masonry block wall DPC
Polystyrene insulation
Ecofoam (not required if an interior wall)
Applied waterproof Note:
50
Prop. all 110mm dia Nova 45mm thick timber
membrane Flow Drain coil for Concretea and strapping over DPC
60mm
5mm min Aluminum angle 20mm timber retaining wall connected to Stoarmat MIRAL
x 20mm SW line via cesspit
gap sealant Plaster system to top
M12 BOLT FIXING
Leave 4-5mm gap between of wall
Backing rod GL:
aluminium and plaster and R1.0 masonry wall insulation
Jamb liner seal with approved sealant 10mm GIB lining
MIN.COVER
H3.1 pre primed &
50 mm
(Head and stiles only) painted fascia/barge
Soffit framing Note:
WINDOW HEAD DETAIL - BLOCK WALL board · Reinforcement not shown for clarity.
1 Soffit lining
Scale 1 : 5 MS sealant 6-8mm,
DPM protect waterproof conc.block
with 20mm Stoarmat MIRAL
EXPOL before installing soffit Plaster system to top TYPICAL MASONRY BLOCK WALL DETAIL
Eco foam Proprietary waterproofing StyroDrain 6
of wall Scale 1 : 10
beneath sill system to all reveals prior Concrete Masonry
to window installation 110mm dia
5mm min gap Novaflo Drain wall
.
50mm MIN.COVER
and reapply sealant on mesh coat batten
before finishing INSULATION AS Timber weatherboards
PER NZBC - H1 over 20mm drained
15-20mm brick slips glued
5° min.slope to outside
pipe or other penetration sloped cavity
directly to the surface of downward - toward the outside
Masonry block wall
Wall underlay
WINDOW JAMB DETAIL - BLOCK WALL 8/10mm sealant bead on pef rod
3 between pipe and plaster INTERNAL CORNER DETAIL
Scale 1 : 5 8
WEATHERBOARD & BRICK VENEER Scale 1 : 5
INTERIOR EXTERIOR
7 PENETRATION DETAIL
MASONRY BLOCK WALL Scale 1 : 10
NOTE :
* All details should read in conjunction with manufacturer's specification, installation manual & Branz Appraisal
* Read in conjunction with Building Code E2/AS1 for code compliance requirement. " @ 2018 Copyright EMACS Group"
TITLE : PROJECT : DRAWN BY : SCALE : REVISION : REVISION DATE : DESCRIPTION :
EMACS GROUP S.B
Engineering Architecture P O Box 67-026 CONSTRUCTION DETAILS- 14 PROPOSED DWELLINGS AT As Above@A3
CHECKED BY : DATE :
Mt. Eden, Auckland
Fax : 09-6307126 CLIENT :
84 WHITNEY STREET, R. R. 23.09.2021
Planning Surveying Phone : 09-6307125 RKD DEVELOPMENT LIMITED BLOCKHOUSE BAY DP : LOT :
Email : emacs@emacsltd.co.nz
LOT 1-3 DP 49665 40 PROJECT NO : EMCS202204 SHEET NO : D 14