E Series

E Series DX 3 Phase Uninterruptible Power System


Advanced Power Protection for Today’s Computing Environments

The Eaton® E Series DX is a three-phase, double conver-


sion uninterruptible power supply (UPS) available in 20,
30, 40, 60 and 80kVA output power ratings. Its design fits
perfectly to any environment where uninterrupted power is
required to secure critical equipment’s continuous opera-
tion. The E Series DX UPS provides a perfect solution for
power protection, and solves power quality problems such
as surges, spikes, voltage fluctuations, harmonic distortion
and frequency fluctuations.
With DX, each phase is independently double converted
and regulated. In addition a PFC (Power Factor Corrected)
controller is used for real time control and data process-
ing, ensuring high availability at all times. Further reliabil-
ity is accomplished by introducing an intelligent charge
mode which significantly prolongs service life of batteries.
On-line double-conversion topology
This topology guarantees a consistently high level of
power quality. Whatever the supply disturbances, the out-
put waveform is regenerated via the AC to DC, then DC
to AC conversion process. The battery is used only as a
backup source.
Excellent Input Performance
With a wide input voltage range the E Series DX is able
to operate in harsh electrical environments, providing
enhanced availability by utilising intelligent IGBT-based
high-frequency technology to achieve greater than a .99
Product Snapshot input power factor. Harmonic current distortion is less than
five percent.
Power Rating: 20/30/40/60/80kVA
High Efficiency
Configuration: Tower The E Series DX can achieve up to 98% efficiency in high
Voltage: 400/230V efficiency mode, reducing electrical costs and total cost of
Frequency: 50/60 Hz (auto-sensing) ownership.
Technology : High-frequency double conversion online
Output overload performance
Providing further peace of mind in harsh electrical envi-
Features: ronments, the E Series DX provides enhanced overload
• On-line double conversion topology assures maximum protection. In fact, the E Series DX can operate for ten min-
reliability utes at a 110% to 125% overload and one minute at a 150%
• High Frequency technology allows a compact design overload with short circuit protection.
that delivers perfect sine wave output.
Automatic bypass
• Intuitive front-panel LCD user interface for consistent
In case of an overload or UPS fault, the DX UPS automati-
status indication
cally transfers the load to utility AC power.
• 0.8 Power Factor output
• Internal battery option for short run times on 20-40kVA Integral Maintenance Bypass
models An in-built maintenance bypass switch enables mainte-
• Tested for generator compatibility nance whilst load is powered
• Automatic bypass for fault-tolerance N+X redundancy
• Optional SNMP communications More capacity and availability can be achieved by parallel
• WINPOWER software monitors power conditions connection of UPS modules for N+1 redundancy or capacity.
Technical specifications
Input Operation environment
380/400/415 Vac (L-L) Temperature 0°C to 40°C
Nominal Voltage
220/230/240 Vac (L-N)
Humidity 20% to 90%
Frequency 40-65 Hz (self-adaptive to 50 Hz and 60 Hz)
Efficiency
Wiring 3-Phase + N + PE
Line mode 92%
THD i <5%
HE (high efficiency) 98%
Power factor >0.99
Display
Dual-line input Supported
Chinese/English UPS status and operation
Battery
instructions. Input voltage, output voltage, current,
Type Maintenance free VRLA batteries LCD
frequency, charger voltage and current, fault and
Up to 15 min with internal batteries on warning display
20-40kVA, LED UPS operation status
Backup time more with external batteries
360 V (30x12 V, 180 cells), 20kVA internal battery Warning equipment
model Buzzer alarm and light double LED
(lead-acid) 384 V (32x12 V, 192 cells), all other models Communication interface
Output RS-232, AS/400, RS485, service, EPO, compensate
Voltage 380/400/415 Vac (L-L) 220/230/240 Vac (L-N) interface for battery temperature, intelligent slot
Frequency 50/60 Hz
Phase Three-phase four wire + ground
Power factor 0.8
Overload capability 125% 10 min, 150% 1 min

Description kVA/kW Model Description Part Number Net weight (kg) Dimensions
(WxDxH mm)
Standard models using external 20/16 Eaton E Series DX 20 kVA EDX20K4E 82 420 x 643 x 956
battery solution
30/24 Eaton E Series DX 30 kVA EDX30K4E 135 470 x 710 x 1150
40/32 Eaton E Series DX 40 kVA EDX40K4E 140 470 x 710 x 1150
60/48 Eaton E Series DX 60 kVA EDX60K4 282 600 x 800 x 1900
80/64 Eaton E Series DX 80 kVA EDX80K4 306 600 x 800 x 1900
Standard models with space 20/16 Eaton E Series DX 20 kVA B EDX20K4EB 120 420 x 710 x 1245
for internal batteries
30/24 Eaton E Series DX 30 kVA B EDX30K4EB 195 470 x 710 x 1753
40/32 Eaton E Series DX 40 kVA B EDX40K4EB 195 470 x 710 x 1753
Standard models with internal 20/16 Eaton E Series DX 20 kVA BI EDX20K4EBI 272 420 x 710 x 1245
batteries installed
30/40 Eaton E Series DX 30 kVA BI EDX30K4EBI 515 470 x 710 x 1753
40/32 Eaton E Series DX 40 kVA BI EDX40K4EBI 515 470 x 710 x 1753

Runtime for 20-40kVA UPS with internal batteries p.f. 0.8 (typical IT server/computer load)

Battery Qty 20 30 40 kVA


9 Ah 12 V 2 x 30 8 – – min
9 Ah 12 V 3 x 32 – 9 – min
9 Ah 12 V 4 x 32 – 13 8 min
* Runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
In the interests of continuous product improvement all specifications are subject to change without notice.

SINGAPORE INDONESIA VIETNAM


Tel : +65 6825 1684 Tel : +62 21 2949 9000 Hanoi
Fax : +65 6825 1689 Fax : +62 21 2949 9001 Tel : +84 4 3936 5303
EatonSEA@eaton.com Fax : +84 4 3936 5307
MALAYSIA
Tel : +603 7804 3618 Ho Chi Minh
Fax : +603 7803 6193 Tel : +84 8 6255 6737
Fax : +84 8 6255 6801 Eaton is a trade name, trademark and/or
THAILAND service mark of Eaton Corporation or its
Tel : +66 2575 0530 subsidiaries and affiliates.
Fax : +66 2575 1579
® 2008 Eaton Corporation
All Rights Reserved
Printed in Singapore
September 2012

You might also like