Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Steam Trap Survey Assistant

Dr. Trap® Jr.

PM15: Ultrasonic Checker & Data Analysis Software

System for a quick and comprehensive


check of steam traps. It consists of:

• Steam Trap Ultrasonic Checker PM11


• Software SurveyPro Light PM150

Features
Steam Trap Ultrasonic Checker PM11 Software SurveyPro Light PM150
can be used for measuring the vibration and temperature Programme for analyzing the data which had been mea-
of each trap installed in your factory. sured by using the steam trap checker PM11 and for de-
termining the condition of the steam trap.
1. The checker displays vibration and temperature at the
same time. Applications
Testing a steam trap Testing a valve
2. One key operation for all functions.

3. Long battery life – 40 hours or more of continuous use.


Automatical shut off of the power after 5 minutes of
idle time.

4. As additional function the checker includes a stop-


watch. Useful for monitoring the periodic characteri-
stics of vibrations.

5. The checker estimates and displays the saturated


steam pressure corresponding to the temperature
measured. Useful for testing not only steam traps, but
also steam valves and pipes.

. Compact, lightweight and easy to carry.

8 MIYAWAKI · English Edition


Steam Trap Survey Assistant
Dr. Trap® Jr.

Technical Specification PM11


Vibration Piezo-electric-ceramic acceleration sensor (10K – 40 KHZ)
Probes
Temperature Thermistor Range: 0 bis 250°C / 32 – 482°F

Displays Illuminated liquid crystal display (LCD)

Housing Heat-resistant plastic (ABS), simple waterproof design

Power supply 2 x 1.5V AA alkaline batteries (40 hours or more); 2 x 1.2V AA NiMH (32 hours or more)

Weight 230 g (incl. batteries)

Ambient working temperature 0 – 40°C (32 – 104°F)

Working Flow

1 2 3
Tag all installed steam traps Make a survey list (management log) Diagnose the traps
Put a tag on or next to each trap in your facto- The survey list contains all necessary data of Diagnose each trap on site using the checker
ry, so that it can be easily identified any time. your steam traps, like tag number, type, ma­ PM 11. Write down the vibration data mea-
nufacturer, size, operating pressure and other sured for each trap.
data and the later test results of each trap.

4 5
Complete the survey list Output the results of the analysis
Start the software SurveyPro Light and enter After entering all test results of the survey, the
the measured vibration data into the survey programme will show you an analysis summa-
list for each trap. Once the vibration value of a ry, lists of all defective steam traps, the sum to-
trap has been entered, the operating condition tal of steam loss, the related financial loss and
of the trap will be displayed immediately. The more. A history graph shows how the steam
list will also display the steam loss of each trap loss and the failure rate have changed over the
(if detected) and the related financial losses. time since the first steam trap survey.

MIYAWAKI · English Edition 69