Bollard and Rail H 2139B: Scale 1: 20

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

300

A
Visibility band (See Notes 7
& 8 and details on H2179B)

120
150

120
Bollard at 3000 centers

400
25 x 25 recess
25

8 helical binding 150 galv. mild steel


tube 8 thk wall

500
or timber rail (Optional)
200
900

Applied finish or Visibility band (See Notes 7

120
exposed aggregate & 8 and details on H2179B)
precast 300
concrete bollard

A
4T10

ELEVATION Scale 1 : 20
100

f
ng as speci
Pavi ed
i 300

25 x 25 recess
100

Concrete footing
Reinforced precast
bollard with 150 hole
85

150 galv. mild steel tube min.


wall thickness 8 set into bollard
500

or
600

150 rough hewn timber rail


500

may be used as an alternative


when shown (Optional)

SECTION A - A
Scale 1 : 20

600 sq.

SECTIONAL ELEVATION Notes:


1. All dimensions are in millimetres.
2. Bollard to be precast, reinforcement as shown.
3. Finish to be exposed aggregate or applied finish
as detailed elsewhere.
4. Exposed aggregate, if specified, to be exposed by
8 helical binding brushing with stuff brush together with
application of water prior to final hardening.
5. An insitu version of this design using selected
300 Dia. concrete drainage pipes is available
from Landscape Unit, Highways Department.

Original
B Rail provision become optional Oct 16
4T10 Signed

A Visibility bands added and top - Sept 09


edge rounded
SECTIONAL PLAN Former Drg. No. H2026 with
- June 94
general revision

REF. REVISION SIGNATURE DATE

HIGHWAYS DEPARTMENT
REFERENCE DRAWING No. CAD
BOLLARD AND RAIL
SCALE
1 : 10 or H 2139B
As Shown