PEAK BELL

300
±.12
5.3
Ø5.35
(136) PSI
APPROX BELL LENGTH PERMEATE PORT
(135) 1/2" NPT FEMALE
.8 Ø4.30 ±.10 Ø4.005±.005
(20) 1.3
(109) (102)
REF (33)
BODY DIA

2.4
(61)
REF
PERMEATE PERMEATE

XXXXXXX 3.50±.03
(89)

SERIAL NUMBER
CL 1.8 CL
(46) 6.0
(152)
CL

FEED CONCENTRATE FEED CONC/PORT


SUPPORT RECOMMENDED SPAN SUPPORT SUPPORT 1" IPS PIPE, GROOVED END
POINT BETWEEN SUPPORTS POINT POINT

3.0 ±.06
(76) CL PORT CL PORT
REF VIEW AT CENTER SUPPORT
CENTER VESSEL ON 2 OR 3 SUPPORTS
AT SPAN(S) "S" : 3 SUPPORTS REQUIRED
FOR LENGTHS -4 AND OVER

DWG PART NO. OF PORTS PORT LOCATION VESSEL QTY.


QTY DESCRIPTION MATERIAL
REF NUMBER

SHELL
Filament Wound Epoxy/Glass composites -
Approx
1 1 99278 SHELL Head locking grooves integrally wound in Dash L P S
place. Weight
2 A/R REF. PAGE 2 F/C Port SA-351 CF8M . Length IN(MM) IN(MM) IN(MM)
LB(KG)
3 A/R 47135 F/C Port Seal Ethylene Propylene - Square Cut
48.00 42.00 25X1 13
4 A/R 45251 F/C Port Retainer 18-8 Stainless Steel -1
HEAD (1219) (1067) (635) (6)
5 2 96827 End Plug Engineering Thermoplastic.
88.00 82.00 56X1 19
6 2 45317 Head Seal Ethylene Propylene - O - Ring -2
HEAD INTERLOCK (2235) (2083) (1422) (9)
7 2 45260 Retainer Ring SA-479 SS316
128.00 122.00 80X1 27
VESSEL SUPPORT -3
(3251) (3099) (2032) (12)
8 2+ 45058 Saddle Engineering Thermoplastic.

9 2+ 47459 Strap Assy. 304 Stainless Steel-PVC Cushion. 168.00 162.00 64X2 34
-4
10 4++
97821 Strap Screw. 5/16-18 UNC X 1.5" L, 18-8 Stainless Steel (4267) (4115) (1626) (16)
ELEMENT INTERFACE WARNING 208.00 202.00 78X2 40
11 2 A/R Adapter Engineering Thermoplastic. INTERNAL PORT PRESSURE -5
NOT TO EXCEED 125 PSI (5283) (5131) (1981) (18)
12 2 45296 Adapter seal Ethylene Propylene - O - Ring
13 A/R A/R PWT seal Ethylene Propylene - O - Ring 248.00 242.00 92X2 45
-6
+
3 each & ++
6 nos. furnished with length code 4,5 & 6. (6299) (6147) (2337) (20)
GENERAL NOTES: THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN, ARE THE CONFIDENTIAL AND PROPRIETARY INFORMATION OF
1. DIMENSIONS IN INCHES (MM APPROX) PENTAIR INDIA PVT. LTD. PENTAIR INDIA PVT. LTD. IS THE SOLE OWNER OF THE INFORMATION AND PROCESSES DEFINED HEREIN.
2. NOT TO BE USED FOR CONSTRUCTION UNLESS CERTIFIED THIS DOCUMENT, AND THE INFORMATION CONTAINED, MAY NOT BE DISCLOSED, REPRODUCED, DUPLICATED, USED, SOLD, VERNA, GOA
PUBLISHED, COMMUNICATED OR OTHERWISE DISTRIBUTED, IN WHOLE OR IN PART, FOR ANY PURPOSE WITHOUT THE EXPRESS
3. SHELL EXTERIOR COATED WITH WHITE RAL 9003, HIGH GLOSS POLYURETHANE PAINT.
WRITTEN CONSENT OF PENTAIR INDIA PVT. LTD. THIS DOCUMENT AND ANY COPIES, IN ALL APPLICABLE FORMATS, SHALL BE
INDIA
RETURNED TO PENTAIR INDIA PVT. LTD. UPON REQUEST.

ALL INDICATED PENTAIR TRADEMARKS AND LOGOS ARE PROPERTY OF PENTAIR.THIRD PARTY REGISTERED AND UNREGISTERED
TRADEMARKS AND LOGOS ARE PROPERTY OF THEIR RESPECTIVE OWNERS.BECAUSE WE ARE CONTINUOSLY IMPROVING OUR
PRODUCTS AND SERVICES, PENTAIR RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. PENTAIR IS AN
EQUAL OPPORTUNITY EMPLOYER.
RATING: PRECAUTIONS: ORDERING:

DESIGN PRESSURE……………………………300 PSI DO…read, understand and follow all instructions; Using the chart below, please check the features Please note that we require your membrane
(2.07 Mpa) failure to take every precaution will void you require and fax them with your purchase brand and model number when ordering. If
MAX. OPERATING TEMP……...………………..120°F warranty and may result in vessel failure order to our customer service department for this information is not initially available,
(49°C) DO…mount the shell on horizontal members at span expedited processing. you may provide it at a later date by
MIN. OPERATING TEMP……...…………………..20°F “S” using complaint vessel supports furnished; For optional materials and/or features not listed checking the appropriate box below.
(-7°C) tighten hold down straps just snug below, please consult factory for pricing and
FACTORY TEST PRESSURE…..……………450 PSIG DO…align and center side ports with the manifold availability.
(3.10 MPa) header. Correct, causes of misalignment in a row
BURST PRESSURE……..………………….….1800 PSI of vessels connected to the same header VESSEL LENGTH CODE – please check one
(12.41 MPa) DO…use flexible type IPS grooved-end pipe
couplings, at side ports; allow full, 0.125 inch CODELINE MODEL 40S30 Non Coded  -1  -2  -3  -4  -5  -6
INTENDED USE: gap between port and piping, and position piping
MEMBRANE BRAND AND MODEL – please check one and fill in information
to maximize flexibility of connection
The Model 40S30 Fiberglass RO/UF Pressure Vessel is
DO…provide flexibility in, and support for piping
designed for continuous, long term use as housing for  Please supply adapters for the following membrane brand and specific model
manifolds so that vessel can grow in length
reverse osmosis and ultrafiltration elements in typical Brand_________________________Model_______________________
under pressure without undue restraint; provide
industrial water treatment systems at pressures up to 300
additional flexible joints in large pipes leading to
psi. Any make of four-inch nominal diameter spiral-  Membrane brand and model information is not available, but will be supplied to Pentair on or
manifold header
wound element is easily accommodated. The appropriate before the following date _____/________/_______
DO…provide overpressure protection for vessel set
interfacing hardware for the element specified is
at not more than 105% of design pressure
furnished with the vessel. CERTIFICATION – please check required
DO…inspect end closures regularly; replace
components that have deteriorated and correct
The Model 40S30 is designed in accordance with the  CE Marked (Not applicable for -1 length vessel).
causes of corrosion
engineering standards of the Boiler and Pressure Vessel
Code of the American Society of Mechanical Engineers  Standard, Certified by Pentair, not code stamped.
DO NOT…work on any component until first
(ASME Code) Section X Edition 2021 and all metallic
verifying that pressure is relieved from vessel
parts are designed as per Section VIII Division I Edition EXTERIOR FINISH
DO NOT… make rigid piping connections to ports
2021.  Standard – White high-gloss RAL 9003 polyurethane coating over sanded surface.
or clamp vessel in any way that resists growth of
The Model 40S30 must be installed, operated and fiberglass shell under pressure; DIA = 0.01 in.
FEED PORT CONFIGURATION
maintained in accordance with the listed precautions and (0.25mm) and L = 0.140 in. (3.5mm) for a  Standard – 1’’ IPS Grooved End
good industrial practice to assure safe operation over a length code –6 vessel  Optional – Multi-Ports, Port clocking.
long service life. DO NOT… hang piping manifolds from ports or use
vessel in any way to support other components. Serial number Opposite
The high performance reinforced plastic shell must be DO NOT… operate vessel at pressures and End End PERMEATE PORT CONFIGURATION
allowed to expand under pressure; undue restraint at temperatures in excess of its rating   Standard – ½’’ NPT Female (Standard per drawing)
support points or piping connections can cause leaks to DO NOT… operate vessel without permeate ports   Optional - ½’’ BSPT/JISPT Female
develop in the shell. This side ported vessel requires internally connected with a complete set of
special precautions in mounting and connection to piping elements and interconnecting hardware. Please fill out your feed port configuration in the space below.
so that the vessel will not be subjected to excessive stress DO NOT… operate vessel with permeate pressure in List port location first followed by port size for each choice.
due to bending moments acting at the side openings in the excess of 125 psi at 120°F (0.86 MPa @ 49°C)
fiberglass shell. DO NOT… overtighten the connection to the Serial number end 
permeate port (hand-tighten plus one-quarter Opposite end 
The end closures, incorporating close-fitting, interlocking turn, check for leaks)
metal components, must be kept dry and free of DO NOT… tolerate leaks or allow end closures to
corrosion; deterioration can lead to catastrophic be routinely wetted in any way
DO NOT… pressurize vessel until double-checking PART
mechanical failure of the heads. PORT SIZE CODE
to verify that the retaining ring is completely NO.
inside the groove A ¾’’ NPT FEMALE 50894
Pentair will assist the purchaser in determining the B ¾’’ BSPT/JISPT FEMALE 50895
suitability of this standard vessel for their specific DO NOT… operate outside the pH range 3-11
C 1’’ GROOVED END 45175
operating conditions. The final determination however,
including evaluation of the standard material of For complete information on proper use of the vessel
CAUTION: Please refer to 40S series USER’S GUIDE - 96897 CODELINE BODY LABELS ARE PLACED AT 90°
construction for compatibility with the specific corrosive
EYE PROTECTION SHOULD BE WORN WHEN
environment, shall be the responsibility of the purchaser. REMOVING OR INSTALLING RETAINING RINGS. ON SERIAL NUMBER END AND AT 270° ON
Alternate materials with enhanced corrosion resistance KEEP FINGERS CLEAR FROM RETAINING RING
THE OPPOSITE SIDE END
are available on special order. WHILE INSTALLING LAST OF TWO TURNS. RING NOTE
MAY SNAP INTO POSITION POSSIBLY PINCHING Spiral Retaining Ring Removal Tool (50303)
FINGERS. Recommended to open and close vessel.
Specifications are subject to change without notice.

THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN, ARE THE CONFIDENTIAL AND PROPRIETARY INFORMATION OF
PENTAIR WATER INDIA PVT. LTD. PENTAIR WATER INDIA PVT. LTD. IS THE SOLE OWNER OF THE INFORMATION AND PROCESSES
DEFINED HEREIN. THIS DOCUMENT, AND THE INFORMATION CONTAINED, MAY NOT BE DISCLOSED, REPRODUCED, DUPLICATED, VERNA, GOA
USED, SOLD, PUBLISHED, COMMUNICATED OR OTHERWISE DISTRIBUTED, IN WHOLE OR IN PART, FOR ANY PURPOSE WITHOUT THE
EXPRESS WRITTEN CONSENT OF PENTAIR WATER INDIA PVT. LTD. THIS DOCUMENT AND ANY COPIES, IN ALL APPLICABLE
INDIA
FORMATS, SHALL BE RETURNED TO PENTAIR WATER INDIA PVT. LTD. UPON REQUEST.
DRAWN BY: RA DRAWING DESCRIPTION: DRAWING N0.: REV.:
ALL INDICATED PENTAIR TRADEMARKS AND LOGOS ARE PROPERTY OF PENTAIR.THIRD PARTY REGISTERED AND UNREGISTERED DATE: 15/09/21 MODEL - 40S30 NC MEMBRANE HOUSING 99312 N
TRADEMARKS AND LOGOS ARE PROPERTY OF THEIR RESPECTIVE OWNERS.BECAUSE WE ARE CONTINUOSLY IMPROVING OUR CHECKED BY: KPS CUSTOMER NAME: VESSEL MODEL:
PRODUCTS AND SERVICES, PENTAIR RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. PENTAIR IS AN - 40S30 (NC)
DATE: 15/09/21
EQUAL OPPORTUNITY EMPLOYER.
APPROVED BY: FF PROJECT NAME: TOTAL QTY:
DATE: 15/09/21 - -
ECN NO. : 5881 CUSTOMER P.O.#: SIZE: SCALE: PAGE NO.:
C 2021 Pentair Water India Pvt. Ltd. DATE: 16/12/21 - A3 NONE 02 OF 02