Fieldstone finish on balcony walls. Fieldstone finish on balcony walls.

PARAPET WALL
North Elevation
IC IC 200mm thick by 500mm high machine cut
Plaster finish below window level. Stacked stone finish below window level.
11.090 external wall on 1:3 cement/sand
IC 0.150 0.200 IC Plaster finish on parts of walls. Plaster finish on parts of walls.
pv mortar,horizontal pointed square
0.200 4.000 0.200 1.000 0.950 1.000 0.200 2.990 0.200 SP
Running bond blocks on walls. joints,bitunminous feld and 25mm hoop
Running bond blocks on walls.
IC 1.350 2.850 0.200 1.500 2.000 1.600 1.590 iron for walls less 100mm thick.
IC Approved tyrolene finish under external
step
window cills.

S-05

1.000
step
BACK FIRST FLOOR SLAB

step
PORCH
pv
(non-slip ceramic tiles f.f)
150mm thick rc slab
4

15
pv

with BRC A142 to


0.200

0.200
SEdetails
pv pv pv

14
pv pv pv
500mm wide by 1800mm 16
high wall mounted
wardrobe COMMON
13 IC
IC IC pv WALLS

5.078
pv
17
BATH 12
200mm thick machine cut external wall on
(non-slip ceramic tiles
3.300

18 f.f)
11
STORE pv LOBBY
pv 1:3 cement/sand mortar,horizontal pointed
19
(non-slip ceramic tiles
10 f.f) (ceramic tiles f.f)
DOWN
BED ROOM 01 (ceramic tiles f.f)
pv
9
square joints,bitunminous feld and 25mm

18G x 0.284
19R x 0.158
0.200
IC
4.000 0.200
8
STAIR WELL hoop iron for walls less 100mm thick.

5.800
7

Approved tyrolene finish under external


500mm wide by pv
KITCHEN
6.801

6 1800mm high
(non-slip ceramic tiles f.f)

LOBBY
wall mounted
window cills.
(ceramic tiles f.f)
5 wardrobe
pv
pv
4
pv Steel casement windows to NOTES
2.300 0.200

pv pv pv pv pv

RG
IC

East Elevation
3

2pv
pv pv pv schedule and detail.

OFFICE 0.200
1
4.190 0.200 LOBBY
pv
UP COMMON
pv (ceramic tiles f.f)
pv GROUND FLOOR SLAB 1. This drawing is protected under the copyright

2.122
BATH
West Elevation

(hardwood parquet f.f)

12.800
(non-slip ceramic tiles

150mm thick rc slab Act. & cannot be used or reproduced


f.f)

S-04 S-04 in part or in whole without authors consent.


with BRC A142 to
11.800

pv pv

pv service hatch SEdetails 2. All dimensions to be checked on site. Written


3 pv
dimension rules over scaled dimension.
0.200

0.200
empyt door opening

FOUNDATION NOTES:
S-05

350mm wide by Any discrepancy in dimensions to be reported

1.500
1800mm high wall
mounted shelves pv 25mm cement screed on to Architect before any work commences.
150mm thick rc foor slab on
1.500

3. All construction works to comply with the


consolidated hardcore filling
pv
arch top door opening

3.900

3.900
latest K.B.S. standard codes of practice.
East Elevation 1:100 North Elevation 1:100 fumigated with anti-termite treatment
DINING ROOM
on solid rock bottom to SE details
(ceramic tiles f.f)
0.800

SUNKEN LOUNGE 4. P.V. denotes permanent ventilation & must


5.400
5.400

2.700
(hardwood parquet f.f)
be provided above all doors & windows except
5.200 pv
S-05 Building Section 1:100 doors to WC's.

0.200
350mm wide by 1800mm high
Fieldstone finish on balcony walls. Fieldstone finish on balcony walls.
pv
wall mounted shelves
5. All walls less 200mm thick to be reinforced
Plaster finish below window level. Plaster finish below window level. with hoop iron at every course.
2
2.700

Plaster finish on parts of walls. Plaster finish on parts of walls. 6. D.P.C. denotes one layer of bituminous felt and
0.200 5.490 0.200 1.500
1.200
pv pv
VERRANDAH should be provided under all external walls.
Running bond blocks on walls.
step

(non-slip ceramic tiles f.f)


Running bond blocks on walls.
7. Water meter to be 300mm above ground level.
1
pv
0.200

0.200

step step

8. All r.c works to Structural Engineer's details. Depth


of foundation to be determined on site,but should
2.310 1.445 7.335 not be less than 900mm.
0.200 5.490 0.200 5.000 0.200
11.090 9. Provide two rows of (600x600x50)mm precast
conc. paving slabs around the building unless
pv pv pv pv
A B C D otherwise stated.
pv
South Elevation 10. Heavy duty 1000 gauge polythene sheeting and
anti-termite treatment to be provided on
under ground floor slab.
0. Ground Floor 1:100
North Elevation 11. Plinth level to be minimum 300mm from
proposed parking level or existing ground level.

pv 12. All surface beds to be casted on well


compacted & well consolidated filling.
pv pv pv
13. Depth of foundation trenches to be minimum
11.090 900mm below reduced ground level.
11.090
S-05

14. All service pipes to be minimum 450mm below


0.200

11.090 reduced ground level.

4 15. All inspection chambers(I.C.) within building,


drive-way & parking areas to be heavy duty,double
0.200

1.300

50mm wide by 1800mm


seal air tight covers while drains in the same areas
2.000

high wall mounted MASTER BATH


wardrobe (non-slip ceramic tiles to be PVC pipes encased in 150mm concrete
surround.
South Elevation 1:100
f.f)

West Elevation 1:100 2. Roof Plan


0.200

pv

PARAPET WALL
4.500

0.200 4.000 0.200


4.650
4.300

16. All dimensions are in millimeters (mm) unless


200mm thick by 500mm high machine cut otherwise stated.
2.000

50mm wide by 1800mm


1.500

BED ROOM 04 WALK-IN


high wall mounted
otherwise stated.
external wall on 1:3 cement/sand To Oloitokitok To Enkariak
wardrobe
(ceramic tiles f.f)
CLOSET
(non-slip ceramic tiles
f.f)
mortar,horizontal pointed square 12m Road Consultant:
joints,bitunminous feld and 25mm hoop
Town Rongena
1,700

iron for walls less 100mm thick.


0.200

East Elevation
0.200

pv
BUILDING HEIGHT
Approved tyrolene finish under external
2.400

window cills.
AXIS ARCHITECTS
0.200

1,300
West Elevation

1.200

1.500

FIRST FLOOR SLAB


pv
WC
S-04 pv
(non-slip ceramic tiles
f.f)
S-04 BUILD AND DESIGN
11.800

11.800

150mm thick rc slab ENAKARIAK RONGENA


0.150

Located at Copy Square Printers and Stationers at


LINTEL LEVEL
3
with BRC A142 to BOREHOLE WATER PROJECT Ntawuoh Plaza,Oloitokitok town.
BEAM LEVEL SEdetails
1.150

contact consultant:0702274994 or 0796670486


500
S-05

pv
SH
CORRIDOR

(non-slip ceramic tiles


6.200

6.200

f.f) pv
1.800

MASTER pv pv WALLS

6m Road
MASTER
2.850

BED ROOM 200mm thick machine cut external wall on


2,500

pv
(ceramic tiles f.f) BED ROOM WC
0.200

(ceramic tiles f.f)


pv pv
(non-slip ceramic tiles

1:3 cement/sand mortar,horizontal pointed


f.f)

0.200 5.000
7,450

square joints,bitunminous feld and 25mm


hoop iron for walls less 100mm thick.
1.500

3.790 0.200
1st FLOOR LEVEL
NGUMAMAS PLACE
Approved tyrolene finish under external
1st BEAM LEVEL window cills.
350mm wide by
1.500
4.400

1800mm high wall service hatch


0.200

500

mounted shelves
Steel casement windows to
BED ROOM 03 schedule and detail.
(ceramic tiles f.f)

2
pv
2,500

OFFICE
2.350

pv
0.200

LOBBY
pv (ceramic tiles f.f)
pv (hardwood parquet f.f)
GROUND FLOOR SLAB
1.300
1.550

pv BALCONY
(ceramic tiles f.f)
KITCHEN
(non-slip ceramic tiles f.f) 150mm thick rc slab
with BRC A142 to
Job Title:
GROUND LEVEL SEdetails
1
0.200

GROUND LEVEL
150

FOUNDATION NOTES: PROPOSED RESIDENTIAL


25mm cement screed on MASSIONATE.
11.090
150mm thick rc foor slab on
2,850

RG

0.200 3.790 0.200 1.500 0.200 5.000 0.200 consolidated hardcore filling Proposed Site
11.090 fumigated with anti-termite treatment 5948 CLIENT:PAUL OMONDI OYUECH
A B C D on solid rock bottom to SE details
South Elevation I.D NO:.14473384
L.R NO:LOITOKITOK/ENKARIAK
1. Story 1:100 S-04 Building Section 1:100 SITE PLAN NOT TO SCALE. RONGENA/5948
P.O BOX:......-00209
450X 600mm MANHOLE
COVER AND FRAME
450X 600mm MANHOLE
COVER AND FRAME 450X 600mm MANHOLE 8mm MAIN BAR AT NUMBER OLOITOKITOK,KENYA.
CAPACITY
350 120

GL GL
150 1,200 150 GL GL GL
COVER AND FRAME 300mm C/C
GL OF DIMENSIONS IN MILLIMETRES (mm).
200 5,200 200 Client signature ......................
120
12mm MAIN BARS AT 300mm CENTRES
E 450X 600mm
MANHOLE WITH C .I.
INLET
MANHOLE OUTLET 150mm THICK TYPE LITRES PERSONS A B C D E F1 F2
FROM SEPTIC 12mm BARS AT 150mm C1 4 INLET PIPE 10mm MAIN BAR C1 4 OUTLET PIPE MANHOLE
LIGHT DUTY COVER 150mm THICK BLOCK WORK Drawing title
100

450
250

500 250
WATER LEVEL TANK OUTLET CENTRES BOTH WAYS IL
A 3000 UP TO 10 800 1000 1000 3000 800 1500 1400
150

STONE WORK WALL


TWL TO SOAK PIT /SUBSOIL Ground
150

B IRRIGATION {50} 5344& 45.


8mm MAIN BAR AT B 6000 11-20 800 1400 1200 3600 1400 1500 1400 plan,Elevations,Sections
150 450150

550

200mm C/C 450X 600mm 1500C/C


150

200mm THICK 100mm th. CONCRETE


B
6000

MANHOLE
G G CONCRETE 1:3:6 800 1400 1200 FOUNDATION MIX 1:3:6
C 9000 21-30 800 1400 1200 3600 1800 1500 1400 , Roof plan
Varries

COVER STONE WORK


E

WALL 200mm THICK. 200mm THICK.


1,400

F1

F2

800 1400 1200 D 12000 31-40 800 1600 1400 4000 2000 1500 1300
STONE WORK STONE WORK WALL scale:
12mm MAIN BARS SOAK PIT AS 'H' DEPTH OF SOAK PIT WALL 100
12mm WATER PROOF
AT 200mm CENTRES SPECIFIED
CEMENT -SAND
AS SPECIFIED 12mm WATER PROOF CEMENT -
SAND RENDERING
12mm WATER PROOF
CEMENT -SAND RENDERING E 15000 41-50 800 1600 1400 4000 2400 1500 1200 1:100
Gravel Fill
PLASTER
OR DIRECTED
150 600 200 F 21000 70-80 1200 2400 1600 4800 2400 2000 1800 Drawn by date:
150
D BY DRAWING {6
M }.

SOAK PIT - PLAN SECTION B-B. Eric Asava OCT 2023


150

150mm THICK 400 80-90 1400 2600 1800 5200 2600 2200 2000
H
BASE SLAB . 400 150 mm CONCRETE BASE SLAB 1:2:4 - 3/4 GRADED G 24000
SEPTIC PLAN Designed by Sign:
SECTION H-H. SECTION G-G. SEPTIC TANK SCHEDULE Eric Asava ......................