Professional Documents
Culture Documents
REA-8681-Wind-Load Calculation - BP Design Basis
REA-8681-Wind-Load Calculation - BP Design Basis
Fup
Ld
Fh
Lf
Lc Lw
Forces Considered
Clip Geometry
Thickness t = = 16.00 mm
Lw = = 200.00 mm
Lc = = 148.00 mm
Ld = = 200.00 mm
Lf = = 15.00 mm
Since the acting stresses are less than the allowable stresses
proposed structure is OK
Since the acting stresses are less than the allowable stresses
proposed structure is OK
Conservatively both the Vertical and Horizontal forces are assumed to act
on the horizontal face of the clip.
Since the acting stresses are less than the allowable stresses
proposed structure is OK
0.611
vk 32.20422 84.93478
ch 1
cs 1.5
P 950.512952
F 241.43029 N/m
0.24143029 kN/m
0.611
vk 32.20422
ch 1
cs 1.5
P 950.512952
F 69.6725994 N/m
0.0696726 kN/m
0.611
vk 32.20422
ch 1
cs 0.5
P 316.837651
F 49.8385624 N/m
0.04983856 kN/m
On W column and stair stringer
Unit Length 1000 mm in Y direction
Breadth 254 mm
Area 254000 mm2 Unit Area
0.254 m2
0.611
vk 84.9347777
ch 1
cs 1.5
P 6611.55444
F 1679.33483 N/m
1.67933483 kN/m
Note: equal per unit length load (0.362kN/m) has been applied on all W beams on both X and Y direction as surface area is
0.611
vk 84.9347777
ch 1
cs 1.5
P 6611.55444
F 484.62694 N/m
0.48462694 kN/m
Unit Length 1000 mm On Tubular Braces in both X and Y direction
Breadth 157.3 mm
Area 157300 mm2 Unit Area
0.1573 m2
0.611
vk 84.9347777
ch 1
cs 0.5
P 2203.85148
F 346.665838 N/m
0.34666584 kN/m
d Y direction as surface area is same in both direction.