Professional Documents
Culture Documents
Military Satadard 105E
Military Satadard 105E
1
Inspection Types
Normal Inspection
Used at start of inspection activity
Tightened Inspection
Instituted when vendor’s recent quality history has
deteriorated
Acceptance requirements for lots are more stringent
Reduced Inspection
Instituted when vendor’s recent quality history has
been exceptionally good
Sample size is usually smaller than under normal
inspection
2
Switching Rules
AND conditions
- Production Steady Start
- 10 consecutive lots accepted
- Approved by responsible authority 2 out of 5 consecutive lots rejected
OR conditions
- Lot rejected
5 consecutive
- Irregular production
lots accepted
- Lot meets neither accept nor
reject criteria
10 consecutive lots remain
- Other conditions warrant return
on tightened inspection
to normal inspection
Discontinue Inspection
Procedure for MIL STD 105E
• Choose AQL
• Choose the inspection level
• Determine the lot size
• Find the appropriate sample code size letter from
table A-1.
• Determine the appropriate type of sampling plan to
use.
• Enter appropriate table to find the type of plan to be
used.
• Determine the corresponding normal and reduced
inspection plans to be used when required.
4
Example
• Suppose product comes from vendor in lots of size 2000
units. The acceptable quality level is 0.65%. Determine the
MIL STD 105E acceptance-sampling system.
Lot Size
= 2000
5
AQL
Plan K
6
AQL
Plan K
7
AQL
Plan K
Sample 50 units
Ac = 1, accept if defects ≤ 1.
Re = 3, reject entire lot if defects ≥ 3.