Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

PBS 3 levels

Q 24 VP TK Q

P P

DN65

V161
RV221
Air Blower FI
PE
TE
221

DN40
221 221

DN40

O O
DN150
FCV221 DN150/100 V221
L22:- PIPE DN150
RC261 L06:- PIPE DN100
PE Air Flow control system
262
EJ1003
DN65
V266
DN65

N HE262 V264 From Air Tank 11 N


RC262 V1002

Air Compressor REC262


TC

V014A
1017

TC
1018

DN250

DN50
M RV111 M

V022 PE
PE
PE TE FI 1014
111

DN150
311 311 311
B0112 DN300/200 NOTE-1
To Receiver tank
Not Connected RD-1001
--
- Expansion L11:- PIPE DN150 DN200/150 V311
L31:- PIPE DN200 FCV311
Bellow NOTE-2
DN150
L L02:- PIPE DN300 ETT1001 PE
L

V023
1011

Flexible/PVC

L04:- PIPE DN125

V042
Hose( DN65)

V043

L11.2 DN150
FI

L11.1 DN150
K 411 K

DN100
DN150/80

SUPERHEATED STEAM SUPPLY SYSTEM

L03:- PIPE DN80


DN80 DN150
DN100/80 V411 FCV411

L41:- PIPE DN80

DN25
PE
041

PE
DN25

1001
J
PE Steam Flow control system J
011
TE
1001
RV011 SH101
DN20

DN100/80

DN25
FI

L01:- PIPE DN100 211


DN80/40
I V039 I
DN80
LE V015 DN100/40 V211 FCV211
SG

L21:- PIPE DN40 L05:- PIPE DN80


PCV112

Water
Exhaust
Reservoir
SG101 DN50/40 V012

V051
H DN80
DN25 H

V011
L01:- bis DN100 WP1001

SPRG DN50
SPRG DN50

CHILLER

DN65
V111
DN25

V2001
CH231
G DN40
RV2001 G

V013B

V036
Vacuum pump system
V6002

DN65
V7002
F F
VP041
DN15

PE

DN15
2002

V233
V234
HIGH PRESSURE TANK SYSTEM HE2001
L04:- PIPE DN125

DN40
V034

V032
V6001 V041
DN40

V7001

DN40
LE
WST501 LE LT
DN40

6001
7001 7001
RV6001 TE
7002 RV7001
E --
Not Connected TE E
- 6002
V501
PE
6002 PE

L13:- PIPE DN40

DN80
7002
WATER STORAGE SYSTEM
SST6001
V053

SST7001

D V056 V057 D
V151

L15:- PIPE DN40 WP151


Water cooling system
EV051 PE
6001
TW051 TW052 PE
7001
TE V232

C
6001
TE L23:- PIPE DN80 C
7001

HE231
WP051
V035

EV031
V055

L05:- PIPE DN80 V231

TW031
WP031
B L03:- PIPE DN80 B
PI-5054
V031
Uncontrolled Once Printed

SHEET TITLE:

24VPTK-PID-001/11
DIAGRAM TITLE:
NOTES: 24VPTK-PID-001
1.On ETT, Following pressure sensors are also present.PE1002 to PE1005,PE1y06,PE1y07,PE1008 to PE1013,
where y represents number 0,1,2. VVPSS FULL SCALE TEST FACILITY
2.On ETT, Following temperature sensors are also present.TE1x02 to TE1x05,TE1z06,TE1z07,TE1x08 to TE1x14, PROCESS FLOW DIAGRAM
where x represents number 0,1,2,3 & z represents number 0,1,2,3,4,5,6.
A PBS NODE: DOCUMENT TYPE: DATE OF ISSUE: DESGIN AGENCY DOCUMENT Sheet Size: A
STATUS:
24VPTK PID Sep-2023 __ A0
IO REFERENCE: EXTERNAL REFERENCE: VERSION: Sheet N°:

IDM_NUM EXTERNALREF --A 11/11


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

You might also like