Incinerator Starting Procedure
Incinerator Starting Procedure
-First open valve 705VOT from Do service tank & Valve 006 VOT MGO in and
007VOT waste oil in and air valve 006vag
A) Check that power lamp is lit.
• Cooling fan start and cooling fan running lamp lights up.
• After pre-purge , perform ignition; once ignited, incineration lamp lights up.
E) Before incinerating waste oil, preheat furnace by running waste oil burner on M.D.O . for 10 to
15 minutes.
F) Make sure that waste oil tank is sufficiently heated (90 to 100 C), open outlet valve of waste oil
tank.
H) Turn handle on three way valve located at the top of waste oil pump to be horizontal to flow to
I) Adjust flow control valve (ball valve) located at burner inlet according to incineration conditions.