Atc Draw Pit - Details of Spur Duct H 2158A: Sectional View

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Footway UPVC weathering apron See detail 'A'

Existing surface 132

130
UPVC coupling (F/F) C.l. plug
C.l. plug
45

10
Carriageway

39

20
ageway

kerb
n.for footway

UPVC weathering

100
n.for carri

apron

n.
Reinstatement in

450 m i
accordance with UPVC coupling
(F/F)
450 m i

Drg. No. H1121-H1131


900 m i

ATC
draw pit 100 Dia. UPVC pipe

20 Soft material

SECTIONAL VIEW
n.

100 Dia. UPVC pipe


50

.D. m i

20
Tee junction 88¢X (F/F
100

100 Dia. UPVC pipe 100 long ATC Key hole


n.

ATC ducts (quantity is


50

12
mi

variable) in footway (Plastic plug


Tee junction 88¢X (F/F
To suit use UPVC pipe in 100 Dia. UPVC pipe
9 2 not shown)

carriageway use G.I. spur duct Access cap


pipe H K
C.I. plug

Year of supply
TYPICAL TRENCH SECTION SECTION W - W PLAN
(For cable connecting detector loops on c/w) DETAIL 'A'

Note 1 updated and plastic plug Original


A May 16
specified signed
Note :
Former Drg. No. H2036/2 & H2036/3A - June 94
with general revision
1. See H2157 for general arrangement and notes
REF. REVISION SIGNATURE DATE

HIGHWAYS DEPARTMENT
REFERENCE DRAWING No. CAD
ATC DRAW PIT - DETAILS OF SPUR DUCT Drg. No. ATC/HK/60

SCALE H 2158A
Diagrammatic

You might also like