H 2155 B
H 2155 B
H 2155 B
> >
A
for cover
40 m m
50mm Ext. Dia. 6 SWG G.I.
telephone mounting tube
Z
Mi
n.1
:60 f
allt
o drai
n
75
>100 50 Ext Dia. 6 SWG G.I.
outlet to mounting tube
2 Nos. 100 mm Int. Dia. UPVC
<150
A
telephone cable & surveilance
duct (See Note 3)
SECTION ELEVATION 5
5
SECTION A
- A
5
Bridge with
X
Y
X 300 400
Y 250 350
25 620 25
5
670
Z 300 200
PLAN
100 Inscription details see H2151 100
JUNCTION BOX 40x15 opening 5
5
5
(Plastic plug not shown)
Notes :
1. All dimensions are in millimetres.
2. Longitudinal location of emergency telephones
to be determined by CE/TCS.
10
-
3. Changes in details subject to approval by
TCS X
CE/TCS & DEMS.
X
40
mould after initial set of the concrete.