8800H01502_ATV Process Quick Reference Guide
8800H01502_ATV Process Quick Reference Guide
8800H01502_ATV Process Quick Reference Guide
01/2015
NOTE: Keys 1, 8 and 9 can be used to control the drive, if control via the
Graphic Display Terminal is activated. To activate the keys on the
Graphic Display Terminal, you first need to set (Config Ref Freq 1) Fr1 to
(Ref. Frequency via Rmt. Term) LCC.
Page 1/4
Altivar Process 600 Quick Reference Guide 8800H01502
01/2015
Page 2/4
Altivar Process 600 Quick Reference Guide 8800H01502
01/2015
Page 3/4
8800H01502
Altivar Process 600 Quick Reference Guide 01/2015
Main Menu 5.6 Pump Monitoring 5.8 Generic Functions 5.11 Error/Warning Handling
5.1 Motor Parameters Pumpcycle Monitoring Speed Limits Auto Fault Reset
5.2 Define System Units Anti-Jam Monit Ramp
Fault Reset
5.3 Sensors Assignment Dry Run Monit Ramp Switching
Catch on the Fly
5.4 Command and Reference Pump Thermal Monit Stop Configuration
5.5 Pump Functions Inlet Pressure Monit Error Detection Disable
Auto DC Injection
5.6 Pump Monitoring Outlet Pressure Monit External Error
Ref. Operations
5.7 Fan High Flow Monitoring
Preset Speeds Output Phase Loss
5.8 Generic Functions
+/- Speed Input Phase Loss
5.9 Generic Monitoring 5.7 Fan
5.10 Input/Output Jump Frequency 4-20 mA Loss
PID Controller
5.11 Error/Warning Handling Jump Frequency PID Controller Fallback Speed
5.12 Maintenance Auto Fault Reset Threshold Reached
Fieldbus Monitoring
Catch on Fly Mains Contractor Comm.
5.1 Motor Parameters Embedded Modbus T.
Reverse Disable
Dual Rating Communication Modul.
Torque Limitation
Motor Control Type Undervoltage handling
Parameters Switching
Motor Data
Stop on Prolonged Spd Warning Groups Config
Motor Thermal Monitori
Motor Control
5.9 Generic Monitoring 5.12 Mainenance
Switching Frequency
Process Underload Diagnostics
5.2 Define System Units Drive warranty mgmt
Process Overload
P Sensor Unit Customer events
Stall Monitoring
Flow Rate Unit Fan magmt
Temperature Unit Pump Thermal Moni. Time counter reset
Currency Unit List
5.10 Input/Output
5.3 Sensors Assignment I/O Assignment (Assgmt) DI/DQ AI/AQ Relay
InletPres Assign. DI1 Assignment DI1 Configuration AI1 Configuration R1 Configuration
OutletPres Assign. DI2 Assignment DI2 Configuration AI2 Configuration R2 Configuration
Inst. Flow Assign. DI3 Assignment DI3 Configuration AI3 Configuration R3 Configuration
DI4 Assignment DI4 Configuration AQ1 Configuration
5.4 Command and
Reference DI5 Assignment DI5 Configuration AQ2 Configuration
Config Ref Freq 1 DI6 Assignment DI6 Configuration Virtual AI1
Ref. 1B Channel Pulse Input DI5 Assign Configuration Pulse
DI5
Ref. 1B Switching
Pulse Input DI6 Assign Configuration Pulse
Reverse Disable
DI6
Control Mode
AI1 Assignment Virtual AI1
Freq. Switch Assign AI2 Assignment
Config. Ref Freq. 2 AI3 Assignment
Copy Ch1-Ch2 AIV1 Assignment
Forced Local Freq.
Forced Local Assign PID Controller
Reverse Assign Feedback (Feed) Reference Frequency Settings Input/Output (IO)
2/3-wire control (Ref)
2-wire type Type of Control Intern PID Ref PID Prop Gain I/O Assignment
Stop Key Enable PID Feedback Config Ref Freq 1 PID Intgl. Gain DI/DQ
HMI cmd. Min PID Feedback Min PID Process PID Derivative Gain AI/AQ
Max PID Feedback Max PID Process PID Ramp Relay
5.5 Pump Functions
PID Feedback AutoManual assign. PID Inversion Ref. Freq Template
PID controller Min fbk Warning PID Preset References PID Min Output
Pump characteristics Max bbk Warning PID Max Output
Flow estimation
PID Error Warning
Pump start stop
PID Integral OFF
Priming pump ctrl
PID Acceleration Time
Flow limitation
PID Start Ref Freq