Professional Documents
Culture Documents
NDT Inspection Report (As Receive) .
NDT Inspection Report (As Receive) .
NDT Inspection Report (As Receive) .
Prepared Approved
NDT Inspector Engineering
Witness by :
Test Result :
Results
No. ID No. QTY Item Evaluation Remarks
Accept Reject
1 N/A 1 Lot Turbine Shaft 52 - B - 101 E - K1 - T - Found Non-Relevant √
2 N/A 1 Set Upper Casing - Found Non-Relevant √
3 N/A 2 Ea Sleeve Bearing TE & CE - Found Non-Relevant √
NDT L.III/Eng.
Comment :
ACCEPTED
Penetrating Process
The results of the Penetrant Testing Inspection Have Been found found Pitting Corosion on Deflector shaft Area
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF PT. JAPA INDOTAMA (THE COMPANY) AND SHALL NOT BE REPRODUCED, USED, TRANSFERRED OR DISCLOSED TO OTHERS, EXCEPT AS AUTHORIZED BY CONTRACT WITH THE COMPANY, WITHOUT THE WRITTEN PERMISSION
OF THE COMPANY
Upper Casing
Penetrating Process
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF PT. JAPA INDOTAMA (THE COMPANY) AND SHALL NOT BE REPRODUCED, USED, TRANSFERRED OR DISCLOSED TO OTHERS, EXCEPT AS AUTHORIZED BY CONTRACT WITH THE COMPANY, WITHOUT THE WRITTEN PERMISSION
OF THE COMPANY
Penetrating Process
The results of the Penetrant Testing Inspection Have Been found Cluster Porosity
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF PT. JAPA INDOTAMA (THE COMPANY) AND SHALL NOT BE REPRODUCED, USED, TRANSFERRED OR DISCLOSED TO OTHERS, EXCEPT AS AUTHORIZED BY CONTRACT WITH THE COMPANY, WITHOUT THE WRITTEN PERMISSION
OF THE COMPANY
:
References: Test Description:
ASTM-E1417 STD-PE-11 Particle: Check Residual Magnet Method
STD-PE-09 Magnaflux 14A Min. : 1 Gauss Continuous Residual
API 687
Others Ardrox SY-8000 Max. : 2 Gauss Technique
: Others: Magnetizer Cable Central Conductor
Test Area Type Mobil Unit Direct Current
All Visible Surfaces Fluorescent wet Yoke End Process
Others Black-ink spray Current Demagnetize
AC
: Media : 2 Gauss
DC
Kerosene Base Min. : 300
Preservative/Rust Protect
Water Base Max.: 500
Witness by :
Test Result :
Results
No. ID No. QTY Item Evaluation Remarks
Accept Reject
NDT L.III/Eng.
Comment :
ACCEPTED
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF PT. JAPA INDOTAMA (THE COMPANY) AND SHALL NOT BE REPRODUCED, USED, TRANSFERRED OR DISCLOSED TO OTHERS, EXCEPT AS AUTHORIZED BY CONTRACT WITH THE COMPANY, WITHOUT THE WRITTEN
PERMISSION OF THE COMPANY
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF PT. JAPA INDOTAMA (THE COMPANY) AND SHALL NOT BE REPRODUCED, USED, TRANSFERRED OR DISCLOSED TO OTHERS, EXCEPT AS AUTHORIZED BY CONTRACT WITH THE COMPANY, WITHOUT THE WRITTEN
PERMISSION OF THE COMPANY