Ultrasound System Specifications

The premium performance of the full


functional Portable A6 provides a fast and
easy diagnosis by:
• Ultra-premium contrast and resolution
imaging benefited from the first RF platform
of the world
• All ranges of features, functions and
probes
• Ease of use and ergonomic design
• Fully independent, triplex multiple mode
System Overview operation for easy in Doppler procedures
• Multi-processors allow simultaneous
Architecture mode changes and support for advanced
• The revolutionary RF platform, The First In system functionality
The World, allows for more accurate • World-class design to be thinner and
information. This platform transfers all RF lighter
data for computing without any information • First in class to introduce capacity touch
loss. It has a much better advantage in detail panel in portable ultrasound system to
imaging than current advanced platforms. simplify workflow and customized
• Thanks to the RF platform, it allows the workflow possibility
development of many RF-based processing • Less 50 sec boot up time for easy mobile
algorithms, which have ultra-premium ability
contrast and resolution imaging
• This unique platform is capable of Applications
processing multiple data streams • Abdomen
simultaneously • Obstetric
• Directional-enhanced information • Gynecology
compiling for more tissue detail and • Cardiology
reduction of angle-generated artifacts • Urology
• Next generation adaptive image processing • Vascular
for noise and artifact reduction that • Small Parts
improves tissue presentation and edge • Pediatrics
definition
Imaging features • Inversion mode(optional)*
• 2D grayscale imaging • Magic cut(optional)*
• Harmonic imaging both in tissue harmonic • Multiline-Free view (optional)*
and pulse inversion harmonic technologies • Tomographic display (MCUT) (optional)*
• VFusion, directional-enhanced • Volume Contrast Imaging(VCI)
information compounding • Niche view
• VSpeckle , specialized and adaptive • Three leads ECG function(optional) *
imaging processing to remove speckle noise • Tissue Doppler (TD) mode(optional)*
artifacts and enhance tissue edge for clarity • Multi-angle
and accuracy
• VTissue, the advanced adaptive image (optional)*
processing to compensate for sound and
speed variation in different tissue
• Auto imaging optimization Standard features
• Easy Comparative Function to compare • Up to 25Mhz high frequency in system
previous exam platform.
• M Mode imaging • RF platform and RF data processing
• Color Doppler imaging • Up to 1500 seconds cine storage
• Power Doppler imaging • 120GB SSD quick boot up and storage
• Pulse wave Doppler imaging • Patient information database
• Duplex 2D/PW Doppler • Image archive on hard drive
• Triplex 2D/Color/PW Doppler • Quick store to USB memory stick
• High PRF pulsed wave Doppler • Quick store to hard drive
• Continuous wave Doppler • Report package
• Zoom • Quick print to B/W and color thermal video
• FULL screen imaging to enlarge imaging printer
size • Network storage and printing
• Dual real time imaging without • Full measurement and analysis package
compromising imaging size • Real time auto wave Doppler track and
• PView for panoramic imaging (optional)* calculations
• TView for trapezoidal imaging
• 3D/4D imaging
• Vascular calculations Keyboard
• Cardiac calculations
• OB calculations and tables • Ergonomic hard keys for general
• Gynecological calculations ultrasound operations
• Urological calculations • 8 TGC slides, functionality at any depth
• Renal calculations • Backlight keys
• Volume calculations
• Wireless networking for easy data sharing, Image display screen
storage and printing*(optional)
• 15.6 inch high resolution IPS, LED
• Up-to-date connectivity and data
technology, pixel resolution
management solutions, wireless , LAN,
• Big angel tilting capability
integrated database*(optional)
• Capability to send data to mobile by mail
Peripherals
and blue tooth*(optional)
• Total mobile medical solution for remote • B&W thermal video printer: Sony UP-
data transfer and diagnostic D897MD (optional)
• DICOM compatibility*(optional) • Color thermal video printer: Sony UP-
• 2USB ports D25MD (optional)
• 8 TGC slides • Memory stick (optional)
• Average 4 multiple adjustable frequency
in every probe and mode Dimensions and Weight
• Up to 512 line density • Length: 412mm
• Width: 390mm
Ergonomics • Depth: 85mm
• Unique human oriented design for • Weight: without accessories approx. 6.8kg
comfort and convenience
• 15.6-inch high resolution flat panel Electrical Power
display with nearly infinite positioning • Voltage: 100-240V AC
adjustments • Frequency: 50/60Hz
• Easy to carry by integrated handle • Power: Max.170VA
• Three probe ports
• Easy detachable probe holder
• Cart support with lifing range up to
150mm *(optional)
• USB DVDRW *(optional)
Transducers A3-6D broadband curved array volume
probe
Transducer Technology
• Field of view: 75 degree
• Xcen technology for wideband frequency • Convex radius: 40mm
• Application: abdomen, ob/gyn, urology
Transducer types • Frequency range: 1.8 – 6.3MHz
• Convex array • Pulsed wave Doppler, color Doppler, power
• Linear array Doppler, harmonic, 3D/4D grayscale and 3D
• Phase array color modes
• 4D probe • Multi-imaging frequency setting in 2D,
• Endocavity probe Harmonic, color Doppler and Wave Doppler
modes

Transducer selection A4-12L broadband linear array


• Electronic switching of transducers
• User customizable imaging presets for • Fine pitch, high resolution
each transducer and application • Applications: vascular, small parts, msk,
• Automatic dynamic receiving focus in all nerve
transducers • Aperture size: 38.4mm
• Multiple adjustable transmit focal zone, • Frequency range: 4.0 -12.1MHz
up to 8 focal zoom • Pulsed wave Doppler, color Doppler, power
Doppler, harmonic
A2-5C Broadband Curved Array • Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
• Field of view: 59 degree modes
• Convex radius: 60mm
• Application: abdomen, ob/gyn, urology,
pediatric A4-9E broadband micro convex endocavity
• Frequency range: 1.6 -5.3MHz array
• Pulsed wave Doppler, color Doppler,
power Doppler, harmonic • Field of view: 150 degree
•Multi-imaging frequency setting in 2D, • Convex radius: 10mm
Harmonic, color Doppler and Wave Doppler • Application: ob/gyn, urology
modes • Frequency range: 3.3-11MHz
•Reusable biopsy guide available • Pulsed wave Doppler, color Doppler, power
Doppler, harmonic
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
• Reusable biopsy guide available
A1-4P phased array
• Application: cardiac, abdomen,
• Aperture size: 17.92mm
• Field of view: 90 degree
• Frequency range: 1.09-4.18Mhz
• Pulsed wave Doppler, continuous wave
Doppler, color Doppler, power Doppler,
harmonic
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
• Selectable image angles, probe
Imaging modes
dependent
• Gain: 0-100%
2D Imaging
• Dynamic range: 30-280 db
• Pre-defined ATGC (adaptive temporal gain • VSharpen to enhance edge contrast
compensation) curves optimized for • Smooth to improve spatial resolution
consistently excellent imaging
• B/M acoustic output: 0-100% Harmonic Imaging
• Depth: able to adjust from 1 to 36cm
• Supports both tissue harmonic and phase
• Select between 1 to 8 transmit focal zones
inversion imaging (transducer and
• Reverse function: on/off
frequency dependence)
• VFusion function
• Second harmonic processing to reduce
• VSpeckle function
artifacts and improve image clarity
• Harmonic imaging both tissue harmonic
• Maximize detail resolution and enhance
and phase inversion
contrast
• Cineloop image review
• Available on all imaging transducers
• Selectable 2D line density
• Extends high performance imaging
• Dual imaging with independent cineloop
capabilities to all patient body types
• 256(8 bit) gray level
• Up to 8 focus zone adjustable
M mode
• Multiple color maps with chroma imaging
• FULL screen imaging to larger image size • Selectable sweeping rates
• Multi frequency: probe dependent • Time marks: 0.025 – 0.5 second
• Gray filter: 7 steps • Selectable display format prospective or
• Persistence: 8steps retrospective (1/3-2/3, 1/2-1/2, 2/3-1/3,
side by side 1/2-1/2, side by side 1/3-2/3,
full screen)
• Chroma colorization with multiple color
maps
• Cineloop review for retrospective analysis
of M-mode data
• 256 gray levels

Color Doppler mode


• Available on all imaging transducers
• Automatically adapts transmit and receive
bandwidth processing based on the color
box position
• Cineloop review with full playback control • PW acoustic output: 0-100%
• Steering on linear array transducers • Selectable low frequency signal filtering
• Selectable in baseline, line density, flash with adjustable wall filter settings
reduction, persistence, maps, frequency, PRF, • Selectable grayscale curve for optimal
wall filter, packet size, color level, sensitivity, display
focus position, acoustic power, and smooth • Selectable chroma colorization maps
• Color gain • Selectable display format prospective or
• Region of interest retrospective (1/3-2/3, 1/2-1/2, 2/3-1/3,
• Baseline invert side by side 1/2-1/2, side by side 1/3-2/3,
• Simultaneous mode during PW mode full screen)
• Smoothing • Auto function to optimize spectral
• Wall filter Doppler displ.
• Zoom • Digitally enhanced stereo output
• 256 gray levels
Power Doppler mode • Post-processing in frozen mode includes
• High sensitive mode for small vessel map, baseline, invert and chroma
visualization • Simultaneous or duplex mode of
• Available on all transducers operation
• Cineloop review • Simultaneous 2D, color Doppler, pulsed
• Multiple color maps Doppler
• Individual controls for gain • High PRF capability in all modes including
• Selectable baseline, line density, flash duplex and triplex
reduction, persistence, maps, frequency, PRF,
wall filter, packet size, color level, sensitivity, Continuous Wave Doppler (CWD)
focus position, acoustic power, and smooth • Cardiac sector array transducer only
• Adjustable region of interest • Maximum velocity range: 19m/sec

Pulsed Wave (PW) Doppler • Available on linear transducers


• Ultra high resolution spectral FFT rate
• Angle correction with automatic velocity Tissue Doppler Imaging (TD) *
scale adjustment
• Normal, invert display around horizontal • Present wall motion spectrum by using
zero line Doppler principle
• Selectable gray filter, dynamic range, • Provide wall motion direction and velocity
frequency, PRF, wall filter, baseline, angel information
correct, sample volume • Available on all sector transducer
• Selectable sweep speeds: 8 steps for cardiac imaging
• Maximum velocity range: 12m/s • Gain
Advanced Imaging controls Full zoom, cineloop review and image
rotation capabilities
VFusion • User can measure distance and area
• Available on all transducers and for 2D, • Measurement can be made on individual
3D/4D frames during cineloop review
• Up to 5 levels of directional imaging
fusion to enrich information 3D/4D
• Operate in conjunction with VSpeckle,
harmonic imaging • 3D/4D rotation
• Grayscale imaging controls
VSpeckle • Selectable rendering approaches
• Unique high quality rendering algorithm
• Available on all transducers and for 2D, • Selectable gray maps
3D/4D • Multi slide cutting
• Virtually eliminate speckle noise artifact • Cineloop 3D
and dynamically enhances tissue margins • Review volume
• Selectable multiple levels of speckle noise
reduction and smoothing Magic Cut*(optional)
• Operates in conjunction with VFusion and
harmonic imaging • Ability to edit images, make possible to
cut away structure obstructing the view in
VTissue the ROI
• Speical imaging processing to adapt to the • Several cutting methods available
speed of the ultrasound variation in
different tissue
• Improved conspicuity of lesions, such as Free View(optional)
stone and tendon
• Provide any plane view to visualize the
Tview internal tissue information
• Improve the contrast resolution to
• Expand view of scanning facilitate the detection of diffuse lesions in
• Available on linear transducers organs

Pview*

• Real time extended field of view


composite imaging
• Ability to back up and realign the image
during acquisition
Inversion mode*(optional)
• This render mode is used to display
anechoic structures such as vessels
• It invert the gray values of the rendered
image, such as black image information
become white and vice versa

Multi-angle M mode *
•Sample on moving tissue from multi-angle
• Present wall motion spectrum based on
tissue moving
System Feature • TIB: thermal index bone
• Probe orientation marker: coincide with a
Display modes probe orientation marking on the probe
• Simultaneous capability • Gray/color bar
• 2D/PW/CW • Measurement result window
• 2D/CF or PDI • Probe type
• 2D/M • Application name
• Dual, 2D/2D • Image depth
• Dual, 2D/2D+CF or PDI • Imaging parameters by mode
• Dual, duplex and triplex • 2D/M mode: acoustic power output,
• Duplex and Triplex mode gain, frequency, frame rate, dynamic range
• Quad display in 3D/4D application • Color mode: color acoustic power
• 9 slice images display in 3D/4D output, color gain, color flow frequency, PRF,
application wall filter
• Time line display • PW/CW mode: Doppler acoustic
• Independent dual 2D/PW or CW power output, Doppler gain, Doppler
• Timed based sweep update mode frequency, PRF, wall filter, sample depth
• Focus zone marker
Display annotation • Body pattern
• PW and CW scale markers: time/speed
• Institution/hospital name
• M scale markers: time/depth, time
• Date: 2 types selectable, YY/MM/DD,
• System measurement display
MM/DD/YY
• System message display
• Time: 2 types selectable, 24hours and 12
• Biopsy guide line
hours
• Heart rate
• Operator identification
• Patient name, first, last
Cineloop
• Patient identification: 30 characters
• Gestational age from LMP/EDC/GA/BBT • Acquisition, storage in memory and display
• VINNO image symbol: Ginkgo leaf of up to 1500 seconds long of 2D, color and
• Power output index PW/CW images for review
• MI: mechanical index
• TIS: thermal index soft tissue Compare
• TIC: thermal index cranial (Bone) • Compare live imaging with stored imaging.
Quick save feature Connectivity
• The system provides quick save function • Standard connectivity features
through USB stick, internal/external HDD • Local print to on-board or off-board
during or after exam video printers through USB port
• Configurable saving file format, VRD • Page report print
(VINNO Raw Data), DICOM,JPEG,BMP,PNG • Image export to removable media
and AVI (external HDD, USB stick)
• Network linkage
Physio • Image export to network storage
• One 3-lead ECG input*(optional) servers
• Gain, sweep rate and display position • DICOM export and retrieve *(optional)
controls • Mobile data transfer solution by
• Automatic heart rate calculation and • Blue tooth*(optional)
display • Email*(optional)
• Fault condition display • Hot point connection
• DICOM workstation for remote diagnostic
Archive solution *(optional)
• DICOM,JPEG,BMP,PNG, AVI
• Patient data input which include patient • VRD and DICOM images stored in disc
ID, name, nationality, birth date, sex, exam can be recalLCD on the VINNO system
physician, quality check, exam operator • JPEG,BMP,PNG and AVI images can be
• Physical data such as weight, height played on
• Patient exam management normal computers
• Patient exam images storage and • On-board patient exam storage
management • Direct digital storage of static image or
• Import VRD format data into the system cineloop images to internal hard disk
from outside media, such as USB stick, drives
external HDD • Fully integrated user interface
• Export patient data into outside medias
Probes/application
Report
• Selectable multiple applications
• Automatically pull patient data into the • Edit exist application preset
report • Edit user defined preset
• Automatically load measurement • Rename preset
worksheet into the report • Return to factory preset
• Pull related exams’ images into the report • Quick save user defined parameters in
• Write comments in the report related application
• Print report through network or local
printer
Safety Conformance Measurement and Analysis
• Regulatory Notice: Generic Measurement in 2D mode
This device is tested to meet all applicable
requirements in relevant. According to • Depth
93/42 EEC, it is class IIa medical device. • Distance
• Conformity to Standards: • Perimeter
• IEC 60601-1 : 2012 Medical electrical • Length and width method
equipment - Part 1: General • Ellipse method
requirements for basic safety and • Polygon method
essential performance • Spline method
• IEC 60601-1-2:2007 Electromagnetic • Tracing method
compatibility - Requirements and tests • Area
• IEC 60601-1-6:2010 Usability • Length and width method
• IEC 60601-2-37:2007 Medical electrical • Ellipse method
equipment - Particular requirements for • Polygon method
the safety of ultrasonic medical • Spline method
diagnostic and monitoring equipment • Tracing method
• IEC 61157:2007 Declaration of • Volume
acoustic output parameters • Single line method
• ISO 10993-1:2009 Biological evaluation • Dual line method
of medical devices • Triple line method
• IEC 62304:2006 Medical device • Single ellipse method
software –Software life cycle processes • Single ellipse and single line method
• IEC 62366:2007 Medical devices - • Angle
Application of usability engineering to • Stenosis
medical devices • Diameter method
• Council Directive 93/42/EEC on Medical • Square meter method
Device • A and B ratio
• WEEE according to 2012/19/EU • Diameter ratio
• RoHS according to 2011/65/EU • Square meter ratio

Generic Measurement in CFM mode


• CFV
• point
• profile
Generic Measurement in M mode • Time mean speed in each stroke
• Depth volume
• Distance • Cardiac output
• Time • Heart rate
• Slope
• Heart rate Abdominal Measurement
• Stenosis • General abdomen
• A and B ratio • Difficult abdomen
• Diameter ratio • Kidney
• Time ratio • Renal vessel
• Velocity ratio • Abdominal trauma

Generic Measurement in PW mode Small Part Measurement


• Speed (include PV (Peak Velocity)) • Thyroid
• Time (include AT (Accelerate Time)) • Breast
• Acceleration • Testis
• PS (Peak Speed in systole period) • Musculoskeletal
• ED (The speed in the end of diastole • Upper and lower extremity joint
period) • Nerve block
• MD (Minimum speed in diastole period)
• TAMAX (maximum speed in time average) Vessel Measurement
• TAMEAN (mean speed in time average) • Carotid artery
• TAMIN (minmum speed in time average) • Upper artery
• PI (Pulsatility Index) • Upper vein
• RI (Resistance Index) • Lower artery
• PS and ED ratio • Lower vein
• ED and PS ratio • Vessel puncture
• A and B ratio (A/B ratio) • Transcranial Doppler
• Speed ratio
• Time ratio Gynecology Measurement
• Acceleration ratio
• FLOWVOL (Flow Volume) • Uterus and Pelvis
• MaxPG ( maximum pressure gradient) • Follicle
• MeanPG (Mean pressure gradient)
• SV ( Stroke Volume)
• Each volume diameter cardiac
Urology Measurement Auto Follicle(2D)(optional) *
• Bladder • Just click on the area of follicle in B mode,
• Prostate the area of this follicle will be reported
• Renal automatically
• Kidney and ureter • Report the area of different follicle in the
• Pelvic Floor dysfunction volume data automatically

Pediatric Measurement Auto NT (Nuchal Translucency )


measurement*
• Neonatal Head
• Neonatal Abdomen • Automatically detect Nuchal Translucency
• Pediatric Abdomen in interest box
• Pediatric Hip • Automatically report thickness result of NT
• FAST
Auto IMT (Intima-Media Thickness)
Obstetrics Measurement measurement*
• OB Early
• OB Mid • Automatically detect intima media
• OB Late thickness in interest box
• Fetal Heart • Automatically report the result of IMT
• Available in linear probe
Cardiac Measurement
• General Smart 3D Calculation
• LV
• MV Displays sequential slices of 3D anatomy to
• Ao facilitate more precise volume analysis of
• AV irregularly-shaped structure
• LA
• RV
• TV
• PV
• RA
• System

You might also like