Professional Documents
Culture Documents
Airklenz Modular Operation Theater With Accessories
Airklenz Modular Operation Theater With Accessories
environment with superior laminar air flow system and a perfect working
environment for any surgeon with zero contamination.
We are introducing as total quality turnkey solution provider for modular
operation theatre. Having well trained with hand so experience and through
knowledge about the latest technology guideline of NABH and ISO standard in
operation theatre, we are highly capable in executing the projects to perfection
as per the guidelines and schedules.
Our Modular Operation theatre has design of continue flow of highly
filtered Bacteria – Free air is reticulated under positive pressure room field and
air contamination generated during surgery are removed from the site.
An Air Handling Unit is a device used to condition and
circulate air as part of a heating, ventilating and air-
conditioning system. An air handler is usually filters, sound
attenuators and dampers. Air handlers usually connect to
ductworks that distribute the conditioned air through the
building and return it to the AHU.
AHUs are encased assembly consisting of sections
containing a fan or fans and other necessary equipment to
perform air supply, air exhaust, filtration, heat recovery.
Our AHUs are designed for lower foot prints, higher
energy efficiency, modularity and a host of other features
like thermal braking and other custom designed features.
FEATURES:
❖Continual room air cleaning
❖Three stage filter system
❖High energy efficiency
❖Rapid, space-saving mounting
❖Modular construction and a complete system
solution
❖Durable quality components
❖Low investment, operation and maintenance costs
PLENUM BOX
Laminar airflow means that the flow of air is continuous, steady and unidirectional,
with the entire body of air in the room moving with a low uniform velocity in parallel
planes. Laminar airflow system has provide ultra clean sterile CLASS 100 clean air in an
isolated area where various kinds of critical and highly sensitive process activities are
carried out in as per ISO 14644-1 standards.
HEPA filters separator less mini-pleat HEPA in aluminium extruded frames with wire
mesh protection and made of ultra fine glass fibre media having a retention capacity of 0.3
micron at 99.97% efficiency with initial pressure drop at 12 mm WG.
ceiling panel
The ceiling panels are non-particle
shedding, load bearing and walkable.
They meet the stringent requirements
of FDA, NIH and international cGMPs.
All components come with a
performance guarantee. The modular
cleanroom components are impact
resistant, chemical and non-shedding.
We are assist you to plan, design laboratory set-up, infrastructure development and operation of
laboratory facilities. We work directly with architects, engineers to ensure completed laboratory space
delivery on time and within budget.
We also help to audit, implement laboratory quality management system (LQMS), documentation,
training and implementation of the system towards NABL accreditation of the clinical laboratory.
We assure that our service will help to improve performance, efficiently use resources, ensure
safety of personnel, within national regulations and clinical laboratory compliance requirements
IVF LAB
Air quality, particle count and sterility
are extremely important in an IVF
laboratory to ensure best clinical
outcomes. Human embryos are extremely
sensitive to the presence of any smells,
Volatile Organic Compounds (VOC),
Chemically Active Compounds (CAC).
Globally, a class 10,000 ppm in air. The
best way to achieve this is by building a
modular clean room. This is done with a
combination of PUF panels, Bioclad and
high efficiency HVAC air system that
control air temperature and particulate
matter, as well as filter harmful VOC.
We undertake complete IVF and IUI Lab Set-ups. Starting with site survey to designing and
development of your architectural design we are committed to the customer through the entire process.
Our experienced team works closely with you to understand your vision and we have solutions
for different specification and budget requirements. We approach all inquires in a scientific and
systematic method and a dedicated project manager will assist you from,
* Analysis of the available space by lab set up team * Presentation of detailed layout by the team
* Once agreed timelines are set to efficiently deliver the complete lab
PASS BOX
The casing of our pass through boxes on
the inside and outside is made of stainless
steels 304 in a ground design.
The door leaves are mounted on the
outside to fit flush with the lock carcase.
Viewing panels that are installed into the door
leaf fitting flush on the both sides and an
electronic & mechanical locking of the doors
provide visible safety.
The locking is realized by door lock seal
using surface holding magnets, switches, a
red/green display and internal wiring with a
voltage of 24 V DC. This also guarantees a
mutual locking of pass through boxes with
swing doors.
The carcase of our pass through box is
welded. The inner corners are designed with a
wide radius to provide a comfortable and
efficient cleansing.