Station Design

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

Design For All Stations

Project Name : Unassigned


Client Name : Unassigned
Engineer Name : Unassigned
Design File : D:\WORKS\Alexa\Staad\tank-WaterTank-1.rcdx
Analysis File : D:\WORKS\Alexa\Staad\tank.std
Analysis Last Modified : 4/16/2023 12:24:27 AM

L/C Analysis
Load Definition
No No
1.2 (LOAD 1: DL) +1.2 (LOAD 3: SL-MAT) +1.2 (LOAD 2: FL) +1.2
1 100
(LOAD 4: FL-MAT)
2 101 1.2 (LOAD 1: DL) +1.2 (LOAD 3: SL-MAT)

Input Data ( Section Cut Settings for Forces )

Vertical Reinforcement
Preferred Section Length : 1 m
Preferred Section Interval : 1 m

Horizontal Reinforcement
Preferred Section Length : 1 m
Preferred Section Interval : 1 m

Wall : W1(U)
Analysis Reference (Surface Number) : W4
Length x Height x Thickness : 2000 x 1800 x 300 mm
Concrete : C21/26 N/sqmm
Reinforcement : Fy420 N/sqmm
Clear Cover : 40 mm

Zone & Curtailment Settings


Zoning Curtailment
Vertical Reinforcement Yes No
Horizontal Reinforcement Yes No
Shear Reinforcement Yes No

Vertical Reinforcement
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Vertical Face- 1
Bending Moment Design Envelope
(kNm)
Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 0.17 0

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 300 300
Locn- 2 0.9 300 300
Locn- 1 0 472 300

Ast Provided (sqmm)


Station→
Stn- 1 Stn- 2
Location↓
Zone - 1
Locn- 3 1.8 754 754
Locn- 2 0.9 754 754
Locn- 1 0 754 754

Ast Provided
Zone - 1
Rebar T12 @ 150
Zone Length
2000
(mm)

Vertical Face- 2
Bending Moment Design Envelope (kNm)
Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 -0.61 -0.45
Locn- 2 0.9 -1.7 -1.57
Locn- 1 0 -0.04 -0.03

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 472 472
Locn- 2 0.9 472 472
Locn- 1 0 472 472

Ast Provided (sqmm)


Station→
Stn- 1 Stn- 2
Location↓
Zone - 1
Locn- 3 1.8 754 754
Locn- 2 0.9 754 754
Locn- 1 0 754 754
Ast Provided
Zone - 1
Rebar T12 @ 150
Zone Length
2000
(mm)

Horizontal Reinforcement
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Horizontal Face- 1
Bending Moment Design Envelope
(kNm)
Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 1.28 0 0.17
Stn- 1 0.45 2.03 0 0.21

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 453.6 270 453.6
Stn- 1 0.45 453.6 270 453.6

Ast Provided (sqmm)


Location→
Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 678.6 678.6 678.6
Zone -1
Stn- 1 678.6 678.6 678.6

Ast Provided
Rebar Zone Length
(mm)
Zone - 1 T12 @ 150 1800

Horizontal Face- 2
Bending Moment Design Envelope (kNm)
Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 0 -2.13 0
Stn- 1 0.45 0 -2.32 -0.87

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Locn- 1 Locn- 2 Locn- 3
Location→
Station↓
0 1 2
Stn- 2 1.35 270 453.6 270
Stn- 1 0.45 270 453.6 453.6

Ast Provided (sqmm)


Location→
Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 678.6 678.6 678.6
Zone -1
Stn- 1 678.6 678.6 678.6

Ast Provided
Rebar Zone Length
(mm)
Zone - 1 T12 @ 150 1800

Shear
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Shear Force Design Envelope (kN)


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 1.37 1.68
Locn- 2 0.9 2.63 2.24
Locn- 1 0 1.45 2.95

Asv Required (sqmm)


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 0 0

Asv Provided (sqmm)


Station→
Stn- 1 Stn- 2
Location↓
Zone - 1
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 0 0

Asv Provided
Zone - 1
Rebar -
Zone Length (mm) 2000

Note : Shear forces are shown with absolute value.

Wall : W2(U)
Analysis Reference (Surface Number) : W1
Length x Height x Thickness : 2000 x 1800 x 300 mm
Concrete : C21/26 N/sqmm
Reinforcement : Fy420 N/sqmm
Clear Cover : 40 mm

Zone & Curtailment Settings


Zoning Curtailment
Vertical Reinforcement Yes No
Horizontal Reinforcement Yes No
Shear Reinforcement Yes No

Vertical Reinforcement
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Vertical Face- 1
Bending Moment Design Envelope
(kNm)
Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 0 0

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 300 300
Locn- 2 0.9 300 300
Locn- 1 0 300 300

Ast Provided (sqmm)


Station→
Stn- 1 Stn- 2
Location↓
Zone - 1
Locn- 3 1.8 754 754
Locn- 2 0.9 754 754
Locn- 1 0 754 754

Ast Provided
Zone - 1
Rebar T12 @ 150
Zone Length
2000
(mm)

Vertical Face- 2
Bending Moment Design Envelope (kNm)
Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 -0.91 -0.89
Locn- 2 0.9 -2.38 -2.39
Locn- 1 0 -0.45 -0.45

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 472 472
Locn- 2 0.9 472 472
Locn- 1 0 472 472

Ast Provided (sqmm)


Station→
Stn- 1 Stn- 2
Location↓
Zone - 1
Locn- 3 1.8 754 754
Locn- 2 0.9 754 754
Locn- 1 0 754 754

Ast Provided
Zone - 1
Rebar T12 @ 150
Zone Length
2000
(mm)

Horizontal Reinforcement
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Horizontal Face- 1
Bending Moment Design Envelope
(kNm)
Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 1.96 0 0.68
Stn- 1 0.45 2.1 0 0.35
Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))
Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 453.6 270 453.6
Stn- 1 0.45 453.6 270 453.6

Ast Provided (sqmm)


Location→
Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 678.6 678.6 678.6
Zone -1
Stn- 1 678.6 678.6 678.6

Ast Provided
Rebar Zone Length
(mm)
Zone - 1 T12 @ 150 1800

Horizontal Face- 2
Bending Moment Design Envelope (kNm)
Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 0 -2.57 0
Stn- 1 0.45 0 -3.44 -0.11

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 270 453.6 270
Stn- 1 0.45 270 453.6 453.6

Ast Provided (sqmm)


Location→
Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 678.6 678.6 678.6
Zone -1
Stn- 1 678.6 678.6 678.6

Ast Provided
Rebar Zone Length
(mm)
Zone - 1 T12 @ 150 1800

Shear
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Shear Force Design Envelope (kN)


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 2.19 2.4
Locn- 2 0.9 3.9 3.95
Locn- 1 0 1.96 1.96

Asv Required (sqmm)


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 0 0

Asv Provided (sqmm)


Station→
Stn- 1 Stn- 2
Location↓
Zone - 1
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 0 0

Asv Provided
Zone - 1
Rebar -
Zone Length (mm) 2000

Note : Shear forces are shown with absolute value.

Wall : W3(U)
Analysis Reference (Surface Number) : W3
Length x Height x Thickness : 2000 x 1800 x 300 mm
Concrete : C21/26 N/sqmm
Reinforcement : Fy420 N/sqmm
Clear Cover : 40 mm

Zone & Curtailment Settings


Zoning Curtailment
Vertical Reinforcement Yes No
Horizontal Reinforcement Yes No
Shear Reinforcement Yes No

Vertical Reinforcement
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Vertical Face- 1
Bending Moment Design Envelope
(kNm)
Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 1.32 1.25
Locn- 2 0.9 1.7 3.08
Locn- 1 0 0.03 0

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 472 472
Locn- 2 0.9 472 472
Locn- 1 0 472 300

Ast Provided (sqmm)


Station→
Stn- 1 Stn- 2
Location↓
Zone - 1
Locn- 3 1.8 754 754
Locn- 2 0.9 754 754
Locn- 1 0 754 754

Ast Provided
Zone - 1
Rebar T12 @ 150
Zone Length
2000
(mm)

Vertical Face- 2
Bending Moment Design Envelope (kNm)
Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 -2.17 -1.48

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 300 300
Locn- 2 0.9 300 300
Locn- 1 0 472 472
Ast Provided (sqmm)
Station→
Stn- 1 Stn- 2
Location↓
Zone - 1
Locn- 3 1.8 754 754
Locn- 2 0.9 754 754
Locn- 1 0 754 754

Ast Provided
Zone - 1
Rebar T12 @ 150
Zone Length
2000
(mm)

Horizontal Reinforcement
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Horizontal Face- 1
Bending Moment Design Envelope
(kNm)
Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 0 1.77 0
Stn- 1 0.45 0.32 2.29 0

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 270 453.6 270
Stn- 1 0.45 453.6 453.6 270

Ast Provided (sqmm)


Location→
Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 678.6 678.6 678.6
Zone -1
Stn- 1 678.6 678.6 678.6

Ast Provided
Rebar Zone Length
(mm)
Zone - 1 T12 @ 150 1800

Horizontal Face- 2
Bending Moment Design Envelope (kNm)
Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 -0.13 0 -1.97
Stn- 1 0.45 -0.27 0 -1.26

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 453.6 270 453.6
Stn- 1 0.45 453.6 270 453.6

Ast Provided (sqmm)


Location→
Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 678.6 678.6 678.6
Zone -1
Stn- 1 678.6 678.6 678.6

Ast Provided
Rebar Zone Length
(mm)
Zone - 1 T12 @ 150 1800

Shear
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Shear Force Design Envelope (kN)


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 1.03 1.02
Locn- 2 0.9 5.25 8.84
Locn- 1 0 14.24 9.4

Asv Required (sqmm)


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 0 0

Asv Provided (sqmm)


Station→
Stn- 1 Stn- 2
Location↓
Zone - 1
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 0 0

Asv Provided
Zone - 1
Rebar -
Zone Length (mm) 2000

Note : Shear forces are shown with absolute value.

Wall : W4(U)
Analysis Reference (Surface Number) : W2
Length x Height x Thickness : 2000 x 1800 x 300 mm
Concrete : C21/26 N/sqmm
Reinforcement : Fy420 N/sqmm
Clear Cover : 40 mm

Zone & Curtailment Settings


Zoning Curtailment
Vertical Reinforcement Yes No
Horizontal Reinforcement Yes No
Shear Reinforcement Yes No

Vertical Reinforcement
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Vertical Face- 1
Bending Moment Design Envelope
(kNm)
Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 1.64 1.25
Locn- 2 0.9 1.71 3.09
Locn- 1 0 0.02 0

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 472 472
Locn- 2 0.9 472 472
Locn- 1 0 472 300

Ast Provided (sqmm)

Station→ Stn- 1 Stn- 2


Location↓
Zone - 1
Locn- 3 1.8 754 754
Locn- 2 0.9 754 754
Locn- 1 0 754 754

Ast Provided
Zone - 1
Rebar T12 @ 150
Zone Length
2000
(mm)

Vertical Face- 2
Bending Moment Design Envelope (kNm)
Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 -2.18 -1.49

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 300 300
Locn- 2 0.9 300 300
Locn- 1 0 472 472

Ast Provided (sqmm)


Station→
Stn- 1 Stn- 2
Location↓
Zone - 1
Locn- 3 1.8 754 754
Locn- 2 0.9 754 754
Locn- 1 0 754 754

Ast Provided
Zone - 1
Rebar T12 @ 150
Zone Length
2000
(mm)

Horizontal Reinforcement
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Horizontal Face- 1
Bending Moment Design Envelope
(kNm)
Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 0 1.82 0
Stn- 1 0.45 0.26 2.31 0

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 270 453.6 270
Stn- 1 0.45 453.6 453.6 270

Ast Provided (sqmm)


Location→
Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 678.6 678.6 678.6
Zone -1
Stn- 1 678.6 678.6 678.6

Ast Provided
Rebar Zone Length
(mm)
Zone - 1 T12 @ 150 1800

Horizontal Face- 2
Bending Moment Design Envelope (kNm)
Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 -0.14 0 -1.99
Stn- 1 0.45 -0.3 0 -1.24

Ast Required (Maximum of Shrinkage and Flexural Bending Moment (sqmm))


Location→ Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 1.35 453.6 270 453.6
Stn- 1 0.45 453.6 270 453.6

Ast Provided (sqmm)


Location→
Locn- 1 Locn- 2 Locn- 3
Station↓
0 1 2
Stn- 2 678.6 678.6 678.6
Zone -1
Stn- 1 678.6 678.6 678.6

Ast Provided
Rebar Zone Length
(mm)
Zone - 1 T12 @ 150 1800

Shear
Design Stations : 2 Nos
Design Locations : 3 Nos
Section Length : 1000 mm
Section Interval : 900 mm

Shear Force Design Envelope (kN)


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 1.59 0.88
Locn- 2 0.9 5.4 8.86
Locn- 1 0 14.25 9.44

Asv Required (sqmm)


Station→ Stn- 1 Stn- 2
Location↓
0.5 1.5
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 0 0

Asv Provided (sqmm)


Station→
Stn- 1 Stn- 2
Location↓
Zone - 1
Locn- 3 1.8 0 0
Locn- 2 0.9 0 0
Locn- 1 0 0 0

Asv Provided
Zone - 1
Rebar -
Zone Length (mm) 2000

Note : Shear forces are shown with absolute value.

You might also like