General
Installation of the magnetic holder Mounting the VT-SWA-1-1X swivel angle sensor
1. Installation direction of pumps with clockwise direction 5. "Paste" the seal ring of the assembly kit into the groove
of rotation: using some grease.
locating pin of magnetic holder points towards the 6. Tighten mounting screws M6 x 35 with washers using a
subplate of the pump (away from the drive motor). The torque of 9 Nm.
bore for the locating pin is marked by a colored point.
2. Place the magnetic holder in the bushing in the housing 2
of the A10 pump intended for this purpose. A special 30
º
tool (plastic installation sleeve, material no.
R900846331) is required to insert and tighten the
countersunk screw! If this installation sleeve is not
available, a suitable non-magnetic material tool must be
used to insert the mounting screw and to enable the
Ø12 +0,05
12,8 –0,1
Check "zero" swivel angle (while system is on) Check "100 %" swivel angle (while system is on)
1. Close all directional valves 1. Swivel angle command value greater than 10.5 V and/or
2. Set a swivel angle command value >5 V and/or >50 % 105 %, pressure command value approx. 100 bar. (With
3. Set a pressure command value of 20 bar (if this is SYDFED valve command value >50 % via the valve direct
technically impossible, set 0 V) control)
2. Let the full volume flow via the actuator, e.g. activate
Notice:
hydraulic motor or set pressure relief valve to
If an external pilot oil supply is used, the pressure
approx. 20 bar; this causes a deliberate error message
command value must be > 2 bar.
by the pilot valve (control deviation too high)
4. Switch on hydraulics and let pump warm up 3. Verify whether the actual swivel angle value (αactual) is
(approx. 5 min.) 10.05 V ±0.01 V and/or +100.5 % ±0.1 %. (With analog
5. Verify whether the actual swivel angle value (αactual) is electronics at the central connector of the pilot valve,
0 V ±0.01 V and/or 0 % ±0.1 %. (With analog electronics pin 6, violet; with digital electronics via WIN-PED and/or
at the central connector of the pilot valve, pin 6, violet; IndraWorks)
with digital electronics via WIN-PED and/or IndraWorks) Analog systems:
Analog systems: In case of variation, use potentiometer (2) to calibrate;
In case of variations, use potentiometer (1) to calibrate; the potentiometer is marked with "G" (= Gain) on the
the potentiometer is marked with "O" (=Offset) on the swivel angle sensor
swivel angle sensor Digital systems:
Digital systems: Start swivel angle - factor calibration via the WIN-PED
Start swivel angle - zero point / swivel angle - offset software or IndraWorks.
calibration via the WIN-PED software or IndraWorks.
3
2 1
Lage der Potentiometer
4 bei Sensoren des Typs
G VT-SWA-1-1X/DFEE
1 2
Notes
Bosch Rexroth AG © This document, as well as the data, specifications and other information set
Hydraulics forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Zum Eisengießer 1 reproduced or given to third parties without consentits consent.
of Bosch Rexroth AG.
97816 Lohr am Main, Germany The data specified only
aboveserve
only to
serve
describe
to describe
the product.
the product.
No statements
No statements
concern-
Phone +49 (0) 93 52 / 18-0 concerning
ing a certaina condition
certain condition
or suitability
or suitability
for a certain
for a application
certain application
can be derived
can be
documentation@boschrexroth.de derived
from ourfrom
information.
our information.
The information
The information
given doesgiven
notdoes
release
not the
release
userthe
from
user
the
www.boschrexroth.de from the obligation
obligation of own judgment
of own judgment
and verification.
and verification. It must be remembered
that
Please
ournote
products
that our
areproducts
subject toarea subject
natural process
to a natural
of wear
process
and of
aging.
wear and
aging.