Job Number: Sheet: X/X

Project Name: Date: 2020/03/02

Revision: 0 By: J.Norton


VIBRATION LIMITS
DYNAMIC RESPONSE OF STRUCTURE:

Exciting Frequency, fe = 16.33 Hz

Peak Horizontal Displacement, Δh(peak) = 0.00 mm


Peak Vertical Displacement, Δv(peak) = 0.13 mm
Peak Horizontal Velocity, vh(peak) = 0.00 mm/s
Peak Vertical velocity, vv(peak) = 13.34 mm/s
Peak Horizontal Acceleration, ah(peak) 0.000 m/s2
Peak Vertical Acceleration, av(peak) 1368.597 mm/s2

HUMAN RESPONSE:
K-values calculated using the equations in the following table

EXCITING K-VALUE
FREQUENCY HORIZONTAL VERTICAL
(Hz) VIBRATIONS VIBRATIONS
1 to 2 28.ah(rms)
10.av(rms).fe0.5
2 to 4
4 to 8 56.ah(rms) / fe 20.av(rms)
8 to 80 160.av(rms) / fe
Ref. ISO 2631 - 1978 & AA_SPEC_114001

Exciting Frequency, fe = 16.33 Hz


RMS Horizontal Acceleration, ah(rms) = 0.000 m/s2
RMS Vertical Acceleration, av(rms) = 0.968 m/s2
Kh = 0.000
Kv = 9.482
K-Value = 9.482
Exposure Time = 1.0 hours

STRUCTURAL INTEGRITY:

If the peak velocity is greater than the limit of 10mm/s specified in DIN 4150-3 structural damage may occur
due to fatigue and the structural integrity must be verified through a fatigue life assessment.

Peak Horizontal Velocity, vh(peak) = 0.00 mm/s < 10mm/s - No Fatigue Assesment Required

Peak Vertical velocity, vv(peak) = 13.34 mm/s > 10mm/s - Fatigue Assesment Required

MACHINE OR EQUIPMENT SENSITIVITY:

Equipment Vibration Limits Provided = N/A mm/s